937 resultados para Coefficient of determination


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The objective of this study was to determine apparent digestibility of protein and energy of ingredients commonly present in rations fed to bullfrog tadpoles Rana catesbeiana such as corn, soybean meal, wheat meal, rice bran, poultry by-product meal, blood meal, fish meal, corn starch and soybean oil. A completely randomized design was used to test ten experimental diets with four replicates. About 30% of the reference diet was replaced by the test ingredients, except for soybean oil that was used at 10% ratio and 0.5% of chromium oxide as inert marker. The values of apparent digestibility coefficient of crude protein (ADCCP) and gross energy (ADCGE) of the protein ingredients were, respectively: fish meal, 81 and 95%; poultry byproduct meal, 82 and 87%; blood meal, 64 and 53%; and soybean meal, 93 and 90%. While for the energetic ingredients, ADCCP and ADCGE, were, respectively: wheat meal, 100 and 72%; rice bran, 57 and 24%; and corn, 84 and 92%. Soybean oil and cornstarch ADCGE values were 70 and 96%, respectively; cornstarch digestibility is highly dependent on feed processing technique. The results showed that the ing redients of plant origin, except for rice bran, had good digestibility, thus indicating that tadpoles can effectively use plant protein. In this trial, the least digestible ingredients were blood meal and rice bran, thus indicating that the use of such ingredients in bullfrog tadpole diets should be limited. © Copyright by the World Aquaculture Society 2005.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Methods based on visual estimation still is the most widely used analysis of the distances that is covered by soccer players during matches, and most description available in the literature were obtained using such an approach. Recently, systems based on computer vision techniques have appeared and the very first results are available for comparisons. The aim of the present study was to analyse the distances covered by Brazilian soccer players and compare the results to the European players', both data measured by automatic tracking system. Four regular Brazilian First Division Championship matches between different teams were filmed. Applying a previously developed automatic tracking system (DVideo, Campinas, Brazil), the results of 55 outline players participated in the whole game (n = 55) are presented. The results of mean distances covered, standard deviations (s) and coefficient of variation (cv) after 90 minutes were 10,012 m, s = 1,024 m and cv = 10.2%, respectively. The results of three-way ANOVA according to playing positions, showed that the distances covered by external defender (10642 ± 663 m), central midfielders (10476 ± 702 m) and external midfielders (10598 ± 890 m) were greater than forwards (9612 ± 772 m) and forwards covered greater distances than central defenders (9029 ± 860 m). The greater distances were covered in standing, walking, or jogging, 5537 ± 263 m, followed by moderate-speed running, 1731 ± 399 m; low speed running, 1615 ± 351 m; high-speed running, 691 ± 190 m and sprinting, 437 ± 171 m. Mean distance covered in the first half was 5,173 m (s = 394 m, cv = 7.6%) highly significant greater (p < 0.001) than the mean value 4,808 m (s = 375 m, cv = 7.8%) in the second half. A minute-by-minute analysis revealed that after eight minutes of the second half, player performance has already decreased and this reduction is maintained throughout the second half. ©Journal of Sports Science and Medicine (2007).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Incluye bibliografía

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background and aims. Disease is influenced by the nutritional status of the individual. We have assessed the relationship between nutritional status and food intake among recently hospitalised older people. Methods. A cross-sectional study was undertaken with 240 older people in a hospital that provides care for the public and private healthcare systems. Nutritional status was classified by the MNA (Mini Nutritional Assessment) into: malnourished, risk of malnutrition and without malnutrition. Food intake was estimated by the reported food intake during a typical day. The Kruskal-Wallis test was used to compare the medians and the correlation coefficient of Spearman to verify the relationship between the consumption of energy, protein and vitamin C and MNA scores. Results. 33.8% were classified as adequate regarding nutritional status; 37.1% were classified as being at risk of malnutrition and 29.1% were classified as malnourished. The malnourished individuals reported significantly less energy and nutrient intake than those at risk of malnutrition or those without malnutrition (P=0.001). Not all nutrient intake, just some (iron, cholesterol and fibre), were lower in malnourished people. Conclusions and implications for practice. Deterioration of the nutritional status of older people is accompanied by a reduction in energy and some nutrient intake. The investigation of food intake in older people could provide important information about nutritional risk. © 2010 Blackwell Publishing Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this work, is presented an alternative and non conventional technique for evaluate the water amount present in the hydrated ethanol used as automotive fuel. The standard technique used in this kind of measure is the use of densimeter. The proposal of this work is based on the measure of the linear attenuation coefficient of hydrated ethanol, using the gamma-ray attenuation technique. The water amount, in volume, can be determined knowing the linear attenuation coefficient of hydrated ethanol. Samples of hydrated ethanol, collected at fuel stations, located in Sorocaba, SP, Brazil, were analyzed and the results showed the feasibility of the technique. © 2011 American Institute of Physics.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose. Isokinetic tests are often applied to assess muscular strength and EMG activity, however the specific ranges of motion used in testing (fully flexed or extended positions) might be constrictive and/or be painful for patients with injuries or under-going rehabilitation. The aim of this study was to examine the effects of different ranges of motion (RoM) when determining maximal EMG during isokinetic knee flexion and extension with different types of contractions and velocities. Methods. Eighteen males had EMG activity recorded on the vastus lateralis, vastus medialis, semitendinosus and biceps femoris muscles during five maximal isokinetic concentric and eccentric contractions for the knee flexors and extensors at 60° • s -1 and 180° • s -1. The root mean square of EMG was calculated at three different ranges of motion: (1) a full range of motion (90°-20° [0° = full knee extension]); (2) a range of motion of 20° (between 60°-80° and 40°-60° for knee extension and flexion, respectively) and (3) at a 10° interval around the angle where peak torque is produced. EMG measurements were statistically analyzed (ANOVA) to test for the range of motion, contraction velocity and contraction speed effects. Coefficients of variation and Pearson's correlation coefficients were also calculated among the ranges of motion. Results. Predominantly similar (p > 0.05) and well-correlated EMG results (r > 0.7, p ≤ 0.001) were found among the ranges of motion. However, a lower coefficient of variation was found for the full range of motion, while the 10° interval around peak torque at 180° • s -1 had the highest coefficient, regardless of the type of contraction. Conclusions. Shorter ranges of motion at around the peak torque angle provides a reliable indicator when recording EMG activity during maximal isokinetic parameters. It may provide a safer alternative when testing patients with injuries or undergoing rehabilitation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We evaluated the population dynamics of Acetes americanus Ortmann, 1893 focusing on sex ratio, individual growth, longevity, and the juvenile recruitment period. Samples were collected monthly from January 2006 to June 2007 in the bay of Ubatuba, Brazil. Specimen growth was identified for each gender, and the chosen cohorts were fitted in a von Bertalanffy Growth Model (VBGM); longevity was estimated by the von Bertalanffy inverse equation, considering 99% of the asymptotic length. A total of 6881 individuals (2343 males and 4538 females) were captured. On average the body size (total length) was greater in females (14.64 ± 3.34 mm) than in males (12.27 ± 1.86 mm). The mean growth curves (obtained by grouping the cohorts for each sex), provided estimates of TL∞ = 19.33 mm, k = 0.02 and t0 = -0.12 days for females and TL∞ = 15.13 mm, k = 0.03 and to = -0.07 days for males, where TL∞ is the asymptotic length, k is coefficient of growth and to is the theorical age when the size is equal to 0. Longevity was estimated at 0.61 years for females and 0.50 years for males. The sex ratio tended to favor females, which corroborates with others studies of sergestids. Our finding that males of A. americanus have higher values of k and therefore achieve a smaller size relative to females has been observed in other penaeids. We concluded that this differential growth pattern between the sexes is found across Dendrobranchiata. The life cycles of penaeids have an average duration of approximately 1-2 years, but our results corroborate other studies that estimate a shorter longevity for Acetes, as species of this genus are typically smaller in size. We found continuous recruitment with two main peaks observed during the study period, corroborating previous studies of Acetes. © The Crustacean Society, 2013. Published by Brill NV, Leiden.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This work describes an electronic system implementation with two force plates, 24 load cells with strain gages, signal conditioning circuit, interfacing circuit and data acquisition system, designed for measuring plantar force distribution in patients. The system presented linear response, low hysteresis, with determination coefficient of 0.9997, precision better than 0,84% and resolution less than 0.5 N. The Measurements are presented on a computer screen and easier visualization to specialists, mainly physicians, physiotherapists and occupational therapists. Using the system, the distribution of weight in the plantar region of 100 normal subjects and 10 hemiplegic patients was investigated. There were determined the relationship between weight distribution on the right and left forefoot, hemiplegic patients and normal patients, with the implemented system. © 2013 Springer.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Although titanium and its alloys own good mechanical properties and excellent corrosion resistance, these materials present poor tribological properties for specific applications that require wear resistance. In order to produce wear-resistant surfaces, this work is aimed at achieving improvement of wear characteristics in Ti-Si-B alloys by means of high temperature nitrogen plasma immersion ion implantation (PIII). These alloys were produced by powder metallurgy using high energy ball milling and hot pressing. Scanning electron microscopy (SEM) and X-ray diffraction identified the presence of α-titanium, Ti6Si2B, Ti5Si3, TiB and Ti3Si phases. Wear tests were carried out with a ball-on-disk tribometer to evaluate the friction coefficient and wear rate in treated and untreated samples. The worn profiles were measured by visible light microscopy and examined by SEM in order to determine the wear rates and wear mechanisms. Ti-7.5Si-22.5B alloy presented the highest wear resistance amongst the untreated alloys produced in this work. High temperature PIII was effective to reduce the wear rate and friction coefficient of all the Ti-Si-B sintered alloys. © 2013 Elsevier B.V.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In the current article, we studied the effect of yttrium [Y3+] ions' substitution on the structure and electric behavior of barium zirconate titanate (BZT) ceramics with a general formula [Ba1-x Y 2x/3](Zr0.25Ti0.75)O3 (BYZT) with [x = 0, 0.025, 0.05] which were prepared by the solid-state reaction method. X-ray diffraction patterns indicate that these ceramics have a single phase with a perovskite-type cubic structure. Rietveld refinement data confirmed [BaO 12], [ZrO6], [TiO6], [YO6] clusters in the cubic lattice. The Y3+ ions' effects on the electric conductivity behavior of BZT ceramics as a function of temperature and frequency are described, which are based on impedance spectroscopy analyses. The complex impedance plots display a double semicircle which highlights the influences of grain and grain boundary on the ceramics. Impedance analyses showed that the resistance decreased with the increasing temperature and resulted in a negative temperature coefficient of the resistance property in all compositions. Modulus plots represent a non-Debye-type dielectric relaxation which is related to the grain and grain boundary as well as temperature-dependent electric relaxation phenomenon and an enhancement in the mobility barrier by Y3+ ions. Moreover, the electric conductivity increases with the replacement of Ba 2+ by Y3+ ions may be due to the rise in oxygen vacancies. © 2013 The Minerals, Metals & Materials Society and ASM International.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The factors that have influence on the energy consumption of a small air conditioning system that are worth mentioning are the efficiencies of the compressor, evaporator and condenser, the form that the refrigerant flow is controlled, the fan model used, and climatic conditions. Within the climate issue, an interesting factor is that the relative humidity when it comes to the effect that it causes, especially in the performance of the air condenser, which generally is not considered in the projects. This study aims to evaluate the influence of humidity on the coefficient of system performance (COP), seeking to quantify their influence when it happens. The tests were performed on a testing bench, mounted at the Laboratory for Energy Efficiency (LAMOTRIZ) UNESP-Campus Guaratinguetá. In the study, the wet bulb temperature was ranged, keeping the rotation of the scroll compressor with application of a frequency inverter in its best performance. The test bench is provided with a supervisory system of data collection that is also able to control all functions of the bench. In the results, there was a significant influence, particularly when comparing high humidity conditions with low humidity, noting that only over 65% relative humidity is that significant changes are observed in the COP of the system. © 2013 Elsevier Inc.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objectives: To investigate the test-retest reliability of mechanical parameters derived from a 3-min isokinetic all-out test, performed at 60 and 100 rpm. Reliability and validity of the peak oxygen uptake derived from 3-min isokinetic all-out test were also tested. Design: 14 healthy male subjects completed an incremental ramp testing and four randomized 3-min isokinetic all-out test (two at 60 rpm and two at 100 rpm). Methods: The absolute and relative reliability of the following parameters were analyzed: peak power, mean power, end power, fatigue index, work performed above end power and peak oxygen uptake. Results: No difference was found between each two sets of data, although there were between-cadence differences for peak power, mean power, end power, and fatigue index. Higher intra-class correlation (ICC) and lower coefficient of variation (CV) were found for end power (ICC = 0.91 and 0.95; CV = 5.6 and 5.7%) and mean power (ICC = 0.97 and 0.98; CV = 2.4 and 3.1%), than for peak power (ICC = 0.81 and 0.84; CV = 8.7 and 10%) and work performed above end power (ICC = 0.79 and 0.84; CV = 7.9 and 10.6%; values reported for 60 rpm and 100 rpm, respectively). High reliability scores were also observed for peak oxygen uptake at both cadences (60 rpm, CV = 3.2%; 100 rpm, CV = 2.3%,) with no difference with the incremental ramp testing peak oxygen uptake. Conclusions: The power profile and peak oxygen uptake of a 3-min isokinetic all-out test are both highly reliable, whether the test is performed at 60 or 100 rpm. Besides, peak oxygen uptake and work performed above end power were not affected by the change in cadence while peak power, mean power, end power, and fatigue index were. © 2013.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Alimentos e Nutrição - FCFAR