922 resultados para CYCLOTRON-RESONANCE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A procedure for the determination of three commonly encountered ecstasy type drugs has been demonstrated using proton nuclear magnetic resonance spectrometry (H-1-NMR).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relative strengths of surface interaction for individual carbon atoms in acyclic and cyclic hydrocarbons adsorbed on alumina surfaces are determined using chemically resolved 13C nuclear magnetic resonance (NMR) T1 relaxation times. The ratio of relaxation times for the adsorbed atoms T1,ads to the bulk liquid relaxation time T1,bulk provides an indication of the mobility of the atom. Hence a low T1,ads/T1,bulk ratio indicates a stronger surface interaction. The carbon atoms associated with unsaturated bonds in the molecules are seen to exhibit a larger reduction in T1 on adsorption relative to the aliphatic carbons, consistent with adsorption occurring through the carbon-carbon multiple bonds. The relaxation data are interpreted in terms of proximity of individual carbon atoms to the alumina surface and adsorption conformations are inferred. Furthermore, variations of interaction strength and molecular configuration have been explored as a function of adsorbate coverage, temperature, surface pre-treatment, and in the presence of co-adsorbates. This relaxation time analysis is appropriate for studying the behaviour of hydrocarbons adsorbed on a wide range of catalyst support and supported-metal catalyst surfaces, and offers the potential to explore such systems under realistic operating conditions when multiple chemical components are present at the surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pathways of biotransformation of 4-fluorobiphenyl (4FBP) by the ectomycorrhizal fungus Tylospora fibrilosa and several other mycorrhizal fungi were investigated by using 19F nuclear magnetic resonance (NMR) spectroscopy in combination with 14C radioisotope-detected high-performance liquid chromatography (14C- HPLC). Under the conditions used in this study T. fibrillosa and some other species degraded 4FBP. 14C-HPLC profiles indicated that there were four major biotransformation products, whereas 19F NMR showed that there were six major fluorine-containing products. We confirmed that 4-fluorobiphen-4'-ol and 4-fluorobiphen-3'-ol were two of the major products formed, but no other products were conclusively identified. There was no evidence for the expected biotransformation pathway (namely, meta cleavage of the less halogenated ring), as none of the expected products of this route were found. To the best of our knowledge, this is the first report describing intermediates formed during mycorrhizal degradation of halogenated biphenyls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increasing occurrence of puffer fish containing tetrodotoxin (TTX) in the Mediterranean could represent a major food safety risk for European consumers and threaten the fishing industry. The work presented herein describes the development of a new enzyme linked immunosorbent assay (mELISA) based on the immobilization of TTX through dithiol monolayers self-assembled on maleimide plates, which provides an ordered and oriented antigen immobilization and favors the antigen-antibody affinity interaction. The mELISA was found to have a limit of detection (LOD) of TTX of 0.23 mg/kg of puffer fish matrix. The mELISA and a surface plasmon resonance (SPR) immunosensor previously developed were employed to establish the cross-reactivity factors (CRFs) of 5,6,11-trideoxy-TTX, 5,11-deoxy-TTX, 11-nor-TTX-6-ol, and 5,6,11-trideoxy-4-anhydro-TTX, as well as to determine TTX equivalent contents in puffer fish samples. Results obtained by both immunochemical tools were correlated (R(2) = 0.977). The puffer fish samples were also analyzed using liquid chromatography-tandem mass spectrometry (LC-MS/MS), and the corresponding CRFs were applied to the individual TTX contents. Results provided by the immunochemical tools, when compared with those obtained by LC-MS/MS, showed a good degree of correlation (R(2) = 0.991 and 0.979 for mELISA and SPR, respectively). The mouse bioassay (MBA) slightly overestimated the CRF adjusted TTX content of samples when compared with the data obtained from the other techniques. The mELISA has been demonstrated to be fit for the purpose for screening samples in monitoring programs and in research activities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A system of software and hardware that combines signal processing and contact microphones using normally inaudible body sounds, including heartbeat/pulse, respiration and internal sounds from the vocal tract that can be heard internally by the performer but not externally by others, to drive resonant filters. Performance at SARC Sonic Lab, Belfast, 19 Feb 2015 in collaboration with Birgit Ulher.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Dyslipidemia has been linked to vascular complications of Type 1 diabetes (T1DM). We investigated the prospective associations of nuclear magnetic resonance-determined lipoprotein subclass profiles (NMR-LSP) and conventional lipid profiles with carotid intima-media thickness (IMT) in T1DM.

METHODS: NMR-LSP and conventional lipids were measured in a subset of Diabetes Control and Complications Trial (DCCT) participants (n = 455) at study entry ('baseline', 1983-89), and were related to carotid IMT determined by ultrasonography during the observational follow-up of the DCCT, the Epidemiology of Diabetes Interventions and Complications (EDIC) study, at EDIC Year 12 (2004-2006). Associations were defined using multiple linear regression stratified by gender, and following adjustment for HbA1c, diabetes duration, body mass index, albuminuria, DCCT randomization group, smoking status, statin use, and ultrasound devices.

RESULTS: In men, significant positive associations were observed between some baseline NMR-subclasses of LDL (total IDL/LDL and large LDL) and common and/or internal carotid IMT, and between conventional total- and LDL-cholesterol and non-HDL-cholesterol and common carotid IMT, at EDIC Year 12; these persisted in adjusted analyses (p < 0.05). Large LDL particles and conventional triglycerides were positively associated with common carotid IMT changes over 12 years (p < 0.05). Inverse associations of mean HDL diameter and large HDL concentrations, and positive associations of small LDL with common and/or internal carotid IMT (all p < 0.05) were found, but did not persist in adjusted analyses. No significant associations were observed in women.

CONCLUSION: NMR-LSP-derived LDL particles, in addition to conventional lipid profiles, may help in identifying men with T1DM at highest risk for vascular disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel microwave high-resolution near-field imaging technique is proposed and experimentally evaluated in reflectometry imaging scenarios involving planar metal-dielectric structures. Two types of resonance near field probes-a small helix antenna and a loaded subwavelength slot aperture are studied in this paper. These probes enable very tight spatial field localization with the full width at half maximum around one tenth of a wavelength, λ, at λ/100-λ/10 standoff distance. Importantly, the proposed probes permit resonance electromagnetic coupling to dielectric or printed conductive patterns, which leads to the possibility of very high raw image resolution with imaged feature-to-background contrast greater than 10-dB amplitude and 50° phase. In addition, high-resolution characterization of target geometries based on the cross correlation image processing technique is proposed and assessed using experimental data. It is shown that printed elements features with subwavelength size ~λ/15 or smaller can be characterized with at least 10-dB resolution contrast.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with a third order shear deformation finite element model wich is applied on the active resonance control thin plate/shell laminated structures with integrated piezoelectric layers of patches, acting as sensors and actuators. The finite element model is a single layer tringular nonconforming plate/shell element with 24 degrees of freedom for he generalized displacements, and one electrical potential degree of freedom for each piezoelectric element layer, wich are surface bonded on the laminated. The newwork method is considered to calculate the dynamic response of the laminated sructures forced to vibrate in the first natural frequency. To achieve a mechanism of active control of the structure dynamic response, a feedback control algorithm is used, coupling the sensor and active piezoelectric layers. The model is applied to the solution of one illustrative case, and the results are presented and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To know how often occur the repetitions of MRI exams and sequences in radiology departments. Methods and Materials: A self applied-questionnaire was used as instrument and assigned to 57 radiographers who performed MRI exams to determine which were the causes that lead to the repetition. The questionnaires were interpreted and statistically analyzed through descriptive statistics and Spearman’s rho correlations. Results: At a 95% confidence interval, the major results suggest that the patient’s movement during de MRI exams is the main cause to repeat this exams (mean of 3.88 on a 5 points likert scale). However, there are causes related to the radiographer’s and the results showed that the introduction of wrong imaging parameters by the performer are a major cause too (N=26). Spearman rho correlations between radiographer’s time of experience and frequency of MRI exams repetitions were poor and not significant (r=0.141; p=0.297). The correlations between radiographer’s tiredness and frequency of MRI exams repetitions were negative, weak and not significant (r= -0.151; p=0.263). Conclusion: The patients’ movement may disrupt the examination or degrade the images with artifacts. The level of experience doesn’t influence the repetitions of MRI exams, it seems that seniors radiographers don’t have improvements in performance as it should be expected. It’s recommendable to do training courses regularly to improve the performance and systematically evaluate. Several features will need to be identified which would decrease the MRI exams repetitions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multiparametric Magnetic Resonance Imaging has been increasingly used for detection, localization and staging of prostate cancer over the last years. It combines high-resolution T2 Weighted-Imaging and at least two functional techniques, which include Dynamic Contrast–Enhanced Magnetic Resonance Imaging, Diffusion-Weighted Imaging, and Magnetic Resonance Imaging Spectroscopy. Although the combined use of a pelvic phased-array and an Endorectal Coil is considered the state-of-the-art for Magnetic Resonance Imaging evaluation of prostate cancer, Endorectal Coil is only absolute mandatory for Magnetic Resonance Imaging Spectroscopy at 1.5 T. Sensitivity and specificity levels in cancer detection and localization have been improving with functional technique implementation, compared to T2 Weighted-Imaging alone. It has been particularly useful to evaluate patients with abnormal PSA and negative biopsy. Moreover, the information added by the functional techniques may correlate to cancer aggressiveness and therefore be useful to select patients for focal radiotherapy, prostate sparing surgery, focal ablative therapy and active surveillance. However, more studies are needed to compare the functional techniques and understand the advantages and disadvantages of each one. This article reviews the basic principles of prostatic mp-Magnetic Resonance Imaging, emphasizing its role on detection, staging and active surveillance of prostate cancer.