Resumo:
The introduction of molecular criteria into the classification of diffuse gliomas has added interesting practical implications to glioma management. This has created a new clinical need for correlating imaging characteristics with glioma genotypes, also known as radiogenomics or imaging genomics. Whilst many studies have primarily focused on the use of advanced magnetic resonance imaging (MRI) techniques for radiogenomics purposes, conventional MRI sequences still remain the reference point in the study and characterization of brain tumours. Moreover, a different approach may rely on diffusion-weighted imaging (DWI) usage, which is considered a “conventional” sequence in line with recently published directions on glioma imaging. In a non-invasive way, it can provide direct insight into the microscopic physical properties of tissues. Considering that Isocitrate-Dehydrogenase gene mutations may reflect alterations in metabolism, cellularity, and angiogenesis, which may manifest characteristic features on an MRI, the identification of specific MRI biomarkers could be of great interest in managing patients with brain gliomas. My study aimed to evaluate the presence of specific MRI-derived biomarkers of IDH molecular status through conventional MRI and DWI sequences.
Resumo:
Background: Twenty-three patients (median age 23 months) who underwent Fallot`s tetralogy repair were investigated prospectively to detect a possible association between histopathologic myocardial remodeling and echocardiographic findings of systolic or diastolic ventricular dysfunction. Methods: Intraoperatively resected infundibular bands and subendocardial biopsy samples from the right ventricle (RV) and left ventricle were obtained for histopathologic evaluation. Tissue Doppler echocardiographic interrogation of the ventricles was performed before surgery and in the postoperative period. Results: Histopathologic data revealed hypertrophy of the RV cardiomyocytes and increased interstitial collagen in both ventricles. Mean values of RV isovolumic acceleration decreased significantly at the third evaluation compared with the preoperative values (P = .006). RV myocardial fibrosis greater than 8.3% was associated with a probability of altered E` of at least 0.7 (odds ratio = 2.31). Conclusion: Preoperative histologic myocardial remodeling influenced the postoperative RV function in this group of patients with late repair. Further studies are necessary to evaluate the myocardium in younger patients and to define its influence in the long-term follow-up. (J Am Soc Echocardiogr 2010;23:912-8.)
Resumo:
PURPOSE: To determine the diagnostic value of the intravascular contrast agent gadocoletic acid (B-22956) in three-dimensional, free breathing coronary magnetic resonance angiography (MRA) for stenosis detection in patients with suspected or known coronary artery disease. METHODS: Eighteen patients underwent three-dimensional, free breathing coronary MRA of the left and right coronary system before and after intravenous application of a single dose of gadocoletic acid (B-22956) using three different dose regimens (group A 0.050 mmol/kg; group B 0.075 mmol/kg; group C 0.100 mmol/kg). Precontrast scanning followed a coronary MRA standard non-contrast T2 preparation/turbo-gradient echo sequence (T2Prep); for postcontrast scanning an inversion-recovery gradient echo sequence was used (real-time navigator correction for both scans). In pre- and postcontrast scans quantitative analysis of coronary MRA data was performed to determine the number of visible side branches, vessel length and vessel sharpness of each of the three coronary arteries (LAD, LCX, RCA). The number of assessable coronary artery segments was determined to calculate sensitivity and specificity for detection of stenosis > or = 50% on a segment-to-segment basis (16-segment-model) in pre- and postcontrast scans with x-ray coronary angiography as the standard of reference. RESULTS: Dose group B (0.075 mmol/kg) was preferable with regard to improvement of MR angiographic parameters: in postcontrast scans all MR angiographic parameters increased significantly except for the number of visible side branches of the left circumflex artery. In addition, assessability of coronary artery segments significantly improved postcontrast in this dose group (67 versus 88%, p < 0.01). Diagnostic performance (sensitivity, specificity, accuracy) was 83, 77 and 78% for precontrast and 86, 95 and 94% for postcontrast scans. CONCLUSIONS: The use of gadocoletic acid (B-22956) results in an improvement of MR angiographic parameters, asssessability of coronary segments and detection of coronary stenoses > or = 50%.
Resumo:
OBJECTIVE: Surface magnetic resonance imaging (MRI) for aortic plaque assessment is limited by the trade-off between penetration depth and signal-to-noise ratio (SNR). For imaging the deep seated aorta, a combined surface and transesophageal MRI (TEMRI) technique was developed 1) to determine the individual contribution of TEMRI and surface coils to the combined signal, 2) to measure the signal improvement of a combined surface and TEMRI over surface MRI, and 3) to assess for reproducibility of plaque dimension analysis. METHODS AND RESULTS: In 24 patients six black blood proton-density/T2-weighted fast-spin echo images were obtained using three surface and one TEMRI coil for SNR measurements. Reproducibility of plaque dimensions (combined surface and TEMRI) was measured in 10 patients. TEMRI contributed 68% of the signal in the aortic arch and descending aorta, whereas the overall signal gain using the combined technique was up to 225%. Plaque volume measurements had an intraclass correlation coefficient of as high as 0.97. CONCLUSION: Plaque volume measurements for the quantification of aortic plaque size are highly reproducible for combined surface and TEMRI. The TEMRI coil contributes considerably to the aortic MR signal. The combined surface and TEMRI approach improves aortic signal significantly as compared to surface coils alone. CONDENSED ABSTRACT: Conventional MRI aortic plaque visualization is limited by the penetration depth of MRI surface coils and may lead to suboptimal image quality with insufficient reproducibility. By combining a transesophageal MRI (TEMRI) with surface MRI coils we enhanced local and overall image SNR for improved image quality and reproducibility.
Resumo:
Due to their relatively small size and central location within the thorax, improvement in signal-to-noise (SNR) is of paramount importance for in vivo coronary vessel wall imaging. Thus, with higher field strengths, coronary vessel wall imaging is likely to benefit from the expected "near linear" proportional gain in SNR. In this study, we demonstrate the feasibility of in vivo human high field (3 T) coronary vessel wall imaging using a free-breathing black blood fast gradient echo technique with respiratory navigator gating and real-time motion correction. With the broader availability of more SNR efficient fast spin echo and spiral techniques, further improvements can be expected.
Resumo:
OBJECTIVES: The objective of this study was to evaluate associations between aortic pulse wave velocity (PWV) and aortic and carotid vessel wall thickness (VWT) using cardiovascular magnetic resonance imaging (MRI) in patients with hypertension as compared with healthy adult volunteers. MATERIALS AND METHODS: Local medical ethics approval was obtained and the participants gave informed consent. Fifteen patients with hypertension (5 men and 10 women; mean [SD] age, 49 [14] years) and 15 age- and sex-matched healthy volunteers were prospectively included and compared. All participants underwent MRI examination for measuring aortic and carotid VWT and aortic PWV with well-validated MRI techniques at 1.5- and 3-T MRI systems: PWV was assessed from velocity-encoded MRI and VWT was assessed by using dual-inversion black-blood gradient-echo imaging techniques. Paired t tests were used for testing differences between the volunteers and the patients and Pearson correlation (r) and univariable and multivariable stepwise linear regression analyses were used to test associations between aortic and carotid arterial wall thickness and stiffness. RESULTS: Mean values for aortic PWV and aortic and carotid VWT (indexed for body surface area [BSA]) were all significantly higher in patients with hypertension as compared with the healthy volunteers (ie, aortic PWV, 7.0 ± 1.4 m/s vs 5.7 ± 1.3 m/s; aortic VWT/BSA, 0.12 ± 0.03 mL/m vs 0.10 ± 0.03 mL/m; carotid VWT/BSA, 0.04 ± 0.01 mL/m vs 0.03 ± 0.01 mL/m; all P < 0.01). Aortic PWV was highly correlated with aortic VWT/BSA (r = 0.76 and P = 0.002 in the patients vs r = 0.63 and P = 0.02 in the volunteers), and in the patients, aortic PWV was moderately correlated with carotid VWT/BSA (r = 0.50; P = 0.04). In the volunteers, correlation between aortic PWV and carotid VWT/BSA was not significant (r = 0.40; P = 0.13). In addition, aortic VWT/BSA was significantly correlated with carotid VWT/BSA, in both the patients (r = 0.60; P = 0.005) and volunteers (r = 0.57; P = 0.007). CONCLUSIONS: In the patients with hypertension and the healthy volunteers, the aortic PWV is associated more strongly with aortic wall thickness than with carotid wall thickness, reflecting site-specific coupling between vascular wall thickness and function.
Resumo:
Aims To evaluate thoracic aortic dilation in patients with Fabry disease (FD). Methods and results A cohort of 106 patients with FD (52 males; 54 females) from three European centres were studied. The diameter of the thoracic aorta was assessed at three levels (sinus of Valsalva, ascending aorta, and descending aorta) using echocardiograms and cardiovascular magnetic resonance imaging. Aortic dilation at the sinus of Valsalva was found in 32.7% of males and 5.6% of females; aneurysms were present in 9.6% of males and 1.9% of females. No aortic dilation was observed in the descending aorta. There was no correlation between aortic diameter at the sinus of Valsalva and cardiovascular risk factors. Conclusion Fabry disease should be considered as a cardiovascular disease that affects the heart and arterial vasculature, including the thoracic aorta. Thus, patients with FD should be closely monitored for the presence, and possible progression and complications of aortic dilation. Clinical Trial Registration: Protocol 101/01. Ethics committee, Faculty of Medicine, Lausanne.
Resumo:
For the development and evaluation of cardiac magnetic resonance (MR) imaging sequences and methodologies, the availability of a periodically moving phantom to model respiratory and cardiac motion would be of substantial benefit. Given the specific physical boundary conditions in an MR environment, the choice of materials and power source of such phantoms is heavily restricted. Sophisticated commercial solutions are available; however, they are often relatively costly and user-specific modifications may not easily be implemented. We therefore sought to construct a low-cost MR-compatible motion phantom that could be easily reproduced and had design flexibility. A commercially available K'NEX construction set (Hyper Space Training Tower, K'NEX Industries, Inc., Hatfield, PA) was used to construct a periodically moving phantom head. The phantom head performs a translation with a superimposed rotation, driven by a motor over a 2-m rigid rod. To synchronize the MR data acquisition with phantom motion (without introducing radiofrequency-related image artifacts), a fiberoptic control unit generates periodic trigger pulses synchronized to the phantom motion. Total material costs of the phantom are US$ < 200.00, and a total of 80 man-hours were required to design and construct the original phantom. With schematics of the present solution, the phantom reproduction may be achieved in approximately 15 man-hours. The presented MR-compatible periodically moving phantom can easily be reproduced, and user-specific modifications may be implemented. Such an approach allows a detailed investigation of motion-related phenomena in MR images.
Resumo:
rejection can lead to loss of function. Histological reading of endomyocardial biopsy remains the "gold standard" for guiding immunosuppression, despite its methodological limitations (sampling error and interobserver variability). The measurement of the T2 relaxation time has been suggested for detection of allograft rejection, on the pathophysiological basis that the T2 relaxation time prolongs with local edema resulting from acute allograft rejection. Using breath-held cardiac magnetic resonance T2 mapping at 1.5 T, Usman et al. (CircCardiovascImaging2012) detected moderate allograft rejection (grade 2R, ISHLT 2004). With modern immunosuppression grade 2R rejection has become a rare event, but the need remains for a technique that permits the discrimination of absent (grade 0R) and mild rejection (grade 1R). We therefore investigated whether an increase of magnetic field strength to 3T and the use of real-time navigator-gated respiration compensation allow for an increase in the sensitivity of T2 relaxation time detection that is necessary to achieve this discrimination. Methods: Eighteen patients received EMB (Tan et al., ArchPatholLabMed2007) and cardiac T2 mapping on the same day. Reading of T2 maps was blinded to the histological results. For final analysis, 3 cases with known 2R rejection at the time of T2 mapping were added, yielding 21 T2 mapping sessions. A respiration-navigator-gated radial gradient-recalled-echo pulse sequence (resolution 1.17 mm2, matrix 2562, trigger time 3 heartbeats, T2 preparation duration TET2 Prep = 60/30/0 ms) was applied to obtain 3 short-axis T2 maps (van Heeswijk et al., JACCCardiovascImaging2012), which were segmented according to AHA guidelines (Cerqueira et al, Circulation2001). The highest segmental T2 values were grouped according to histological rejection grade and differences were analyzed by Student's t-test, except for the non-blinded cases with 2R rejection. The degree of discrimination was determined using the Spearman's ranked correlation test. Results: The high-quality T2 maps allowed for visual differentiation of the rejection degrees (Figure 1), and the correlation of T2 mapping with the histological grade of acute cellular rejection was significant (Spearman's r = 0.56, p = 0.007). The 0R (n = 15) and 1R (n = 3) degrees demonstrated significantly different T2 values (46.9 ± 5.0 and 54.3 ± 3.0 ms, p = 0.02, Figure 2). Cases with 2R rejection showed clear T2 elevation (T2 = 60.3 ± 16.2 ms). Conclusions: This pilot study demonstrates that non-invasive free-breathing cardiac T2 mapping at 3T discriminates between no and mild cardiac allograft rejection. Confirmation of these encouraging results in a larger cohort should consider a study able to show equivalency or superiority of T2 mapping.
Resumo:
Cardiovascular disease is the leading cause of death worldwide. Within this subset, coronary artery disease (CAD) is the most prevalent. Magnetic resonance angiography (MRA) is an emerging technique that provides a safe, non-invasive way of assessing CAD progression. To generate contrast between tissues, MR images are weighted according to the magnetic properties of those tissues. In cardiac MRI, T2 contrast, which is governed by the rate of transverse signal loss, is often created through the use of a T2-Preparation module. T2-Preparation, or T2-Prep, is a magnetization preparation scheme used to improve blood/myocardium contrast in cardiac MRI. T2-Prep methods generally use a non-selective +90°, 180°, 180°, -90° train of radiofrequency (RF) pulses (or variant thereof), to tip magnetization into the transverse plane, allow it to evolve, and then to restore it to the longitudinal plane. A key feature in this process is the combination of a +90° and -90° RF pulse. By changing either one of these, a mismatch occurs between signal excitation and restoration. This feature can be exploited to provide additional spectral or spatial selectivity. In this work, both of these possibilities are explored. The first - spectral selectivity - has been examined as a method of improving fat saturation in coronary MRA. The second - spatial selectivity - has been examined as a means of reducing imaging time by decreasing the field of view, and as a method of reducing artefacts originating from the tissues surrounding the heart. Two additional applications, parallel imaging and self-navigation, are also presented. This thesis is thus composed of four sections. The first, "A Fat Signal Suppression for Coronary MRA at 3T using a Water-Selective Adiabatic T2-Preparation Technique", was originally published in the journal Magnetic Resonance in Medicine (MRM) with co-authors Ruud B. van Heeswijk and Matthias Stuber. The second, "Combined T2-Preparation and 2D Pencil Beam Inner Volume Selection", again with co-authors Ruud van Heeswijk and Matthias Stuber, was also published in the journal MRM. The third, "A cylindrical, inner volume selecting 2D-T2-Prep improves GRAPPA-accelerated image quality in MRA of the right coronary artery", written with co-authors Jerome Yerly and Matthias Stuber, has been submitted to the "Journal of Cardiovascular Magnetic Resonance", and the fourth, "Combined respiratory self-navigation and 'pencil-beam' 2D-T2 -Prep for free-breathing, whole-heart coronary MRA", with co¬authors Jerome Chaptinel, Giulia Ginami, Gabriele Bonanno, Simone Coppo, Ruud van Heeswijk, Davide Piccini, and Matthias Stuber, is undergoing internal review prior to submission to the journal MRM. -- Les maladies cardiovasculaires sont la cause principale de décès dans le monde : parmi celles-ci, les maladies coronariennes sont les plus répandues. L'angiographie par résonance magnétique (ARM) est une technique émergente qui fournit une manière sûre, non invasive d'évaluer la progression de la coronaropathie. Pour obtenir un contraste entre les tissus, les images d'IRM sont pondérées en fonction des propriétés magnétiques de ces tissus. En IRM cardiaque, le contraste en T2, qui est lié à la décroissance du signal transversal, est souvent créé grâce à l'utilisàtion d'un module de préparation T2. La préparation T2, ou T2-Prep, est un système de préparation de l'aimantation qui est utilisé pour améliorer le contraste entre le sang et le myocarde lors d'une IRM cardiaque. Les méthodes de T2-Prep utilisent généralement une série non-sélective d'impulsions de radiofréquence (RF), typiquement [+ 90°, 180°, 180°, -90°] ou une variante, qui bascule l'aimantation dans le plan transversal, lui permet d'évoluer, puis la restaure dans le plan longitudinal. Un élément clé de ce processus est la combinaison des impulsions RF de +90° et -90°. En changeant l'une ou l'autre des impulsions, un décalage se produit entre l'excitation du signal et de la restauration. Cette fonction peut être exploitée pour fournir une sélectivité spectrale ou spatiale. Dans cette thèse, les deux possibilités sont explorées. La première - la sélectivité spectrale - a été examinée comme une méthode d'améliorer la saturation de la graisse dans l'IRM coronarienne. La deuxième - la sélectivité spatiale - a été étudiée comme un moyen de réduire le temps d'imagerie en diminuant le champ de vue, et comme une méthode de réduction des artefacts provenant des tissus entourant le coeur. Deux applications supplémentaires, l'imagerie parallèle et la self-navigation, sont également présentées. Cette thèse est ainsi composée de quatre sections. La première, "A Fat Signal Suppression for Coronary MRA at 3T using a Water-Selective Adiabatic T2-Preparation Technique", a été publiée dans la revue médicale Magnetic Resonance .in Medicine (MRM) avec les co-auteurs Ruud B. van Heeswijk et Matthias Stuber. La deuxième, Combined T2-Preparation and 2D Pencil Beam Inner Volume Selection", encore une fois avec les co-auteurs Ruud van Heeswijk et Matthias Stuber, a également été publiée dans le journal MRM. La troisième, "A cylindrical, inner volume selecting 2D-T2-Prep improves GRAPPA- accelerated image quality in MRA of the right coronary artery", écrite avec les co-auteurs Jérôme Yerly et Matthias Stuber, a été présentée au "Journal of Cardiovascular Magnetic Resonance", et la quatrième, "Combined respiratory self-navigation and 'pencil-beam' 2D-T2 -Prep for free-breathing, whole-heart coronary MRA", avec les co-auteurs Jérôme Chaptinel, Giulia Ginami, Gabriele Bonanno , Simone Coppo, Ruud van Heeswijk, Davide Piccini, et Matthias Stuber, subit un examen interne avant la soumission à la revue MRM.
Resumo:
A greater understanding of the molecular basis of hibernating myocardium may assist in identifying those patients who would most benefit from revascularization. Paired heart biopsies were taken from hypocontractile and normally-contracting myocardium (identified by cardiovascular magnetic resonance) from 6 patients with chronic stable angina scheduled for bypass grafting. Gene expression profiles of hypocontractile and normally-contracting samples were compared using Affymetrix microarrays. The data for patients with confirmed hibernating myocardium were analysed separately and a different, though overlapping, set (up to 380) of genes was identified which may constitute a molecular fingerprint for hibernating myocardium. The expression of B-type natriuretic peptide (BNP) was increased in hypocontractile relative to normally-contracting myocardium. The expression of BNP correlated most closely with the expression of proenkephalin and follistatin 3, which may constitute additional heart failure markers. Our data illustrate differential gene expression in hypocontractile and/hibernating myocardium relative to normally-contracting myocardium within individual human hearts. Changes in expression of these genes, including increased relative expression of natriuretic and other factors, may constitute a molecular signature for hypocontractile and/or hibernating myocardium.