959 resultados para Bypass


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Spiripockia punctatais a new genus and species of Pomatiopsidae found in a cave from Serra Ramalho, SW Bahia, Brazil. The taxon is troglobiont (restricted to subterranean realm), and is characterized by the shell weakly elongated, fragile, translucent, normally sculptured by pustules with periostracum hair on tip of pustules; peristome highly expanded; umbilicus opened; radular rachidian with 6 apical and 3 pairs of lateral cusps; osphradium short, arched; gill filaments with rounded tip; prostate flattened, with vas deferens inserting subterminally; penis duct narrow and weakly sinuous; pallial oviduct simple anteriorly, possessing convoluted bypass connecting base of bulged portion of transition between visceral and pallial oviducts with base of seminal receptacle; spermathecal duct complete, originated from albumen gland. The description of this endemic species may raise protective environmental actions to that cave and to the Serra Ramalho Karst area.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: Estudo longitudinal, prospectivo, aleatório e encoberto para avaliar a influência do local de inserção do dreno pleural, de PVC atóxico, na função pulmonar e na dor pós-operatória dos pacientes submetidos à revascularização do miocárdio nos três primeiros dias pós-cirúrgicos e logo após a retirada do dreno. PACIENTES E MÉTODOS: Trinta e seis pacientes escalados para cirurgia eletiva de revascularização do miocárdio, com uso de circulação extracorpórea (CEC), em dois grupos: grupo SX (dreno subxifoide) e grupo IC (dreno intercostal). Feitos registros espirométricos, da gasometria arterial e da dor. RESULTADOS: Trinta e um pacientes analisados, 16 no grupo SX e 15 no grupo IC. O grupo SX apresentou valores espirométricos maiores do que o grupo IC (p < 0,05) no pós-operatório (PO), denotando menor influência do local do dreno na respiração. A PaO2 arterial no segundo PO aumentou significantemente no grupo SX quando comparada com o grupo IC (p < 0,0188). A intensidade da dor no grupo SX, antes e após a espirometria, era menor do que no grupo IC (p < 0,005). Houve aumento significativo dos valores espirométricos em ambos os grupos após a retirada do dreno pleural. CONCLUSÃO: A inserção do dreno na região subxifoide altera menos a função pulmonar, provoca menos desconforto e possibilita uma melhor recuperação dos parâmetros respiratórios.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

FUNDAMENTO: A Intervenção Coronariana Percutânea (ICP) vem aumentando na doença arterial coronariana crônica. Consequentemente, cada vez mais pacientes submetidos a Cirurgia de Revascularização Miocárdica (CRM) apresentam stent coronariano. OBJETIVO: Avaliar a influência do antecedente de stent coronariano na mortalidade hospitalar após CRM. MÉTODOS: Análise prospectiva com 1.099 pacientes consecutivos submetidos a CRM com circulação extracorpórea, entre maio/2007 e junho/2009. Pacientes sem ICP prévia (n = 938; 85,3%) foram comparados com pacientes com ICP prévia (n = 161; 14,6%), utilizando modelos de regressão logística e análise de pareamento de amostras. RESULTADOS: Ambos os grupos apresentavam semelhança em relação aos fatores de risco, exceto pela maior presença de pacientes com angina instável no grupo com ICP prévia (16,1% vs. 9,9%; p = 0,019). A mortalidade hospitalar após CRM foi maior entre os pacientes com ICP prévia (9,3% vs. 5,1%, p = 0,034), e foi semelhante à esperada em relação ao EuroSCORE e ao 2000 Bernstein-Parsonnet score. Na análise com regressão logística multivariada a ICP prévia emergiu como fator de risco independente para mortalidade hospitalar pós-operatória (odds ratio 1,94; IC 95% 1,02-3,68; p = 0,044) tão forte quanto diabetes (odds ratio 1,86; IC 95% 1,07-3,24; p = 0,028). Após o pareamento dos grupos, a mortalidade hospitalar continuou sendo maior entre os pacientes com ICP prévia, com odds ratio 3,46 ; IC 95% 1,10-10,93; p = 0,034. CONCLUSÃO: A ICP prévia em pacientes com doença coronariana multiarterial é fator de risco independente para mortalidade hospitalar após CRM. Tal fato deve ser considerado quando a ICP for indicada como alternativa inicial em pacientes com doença arterial coronariana mais avançada. (Arq Bras Cardiol. 2012; [online].ahead print, PP.0-0)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: A cirurgia de revascularização miocárdica (CRM) na fase aguda do infarto do miocárdio (IAM) está associada a aumento do risco operatório. O objetivo do estudo foi determinar fatores preditores de mortalidade intra-hospitalar nos pacientes submetidos a CRM no IAM. MÉTODOS: Durante três anos, todos os pacientes submetidos a CRM no IAM foram analisados retrospectivamente, utilizando o banco de dados institucional. Sessenta variáveis por paciente foram avaliadas: 49 variáveis pré-operatórias provenientes dos escores 2000 Bernstein-Parsonnet e EuroSCORE; 4 variáveis pré-operatórias não consideradas por esses escores (tempo entre o IAM e a CRM, valor máximo de CKMB, valor máximo de troponina e supradesnivelamento do segmento ST) e 7 variáveis intraoperatórias [uso de circulação extracorpórea (CEC), tempo de CEC, tipo de cardioplegia, endarterectomia, número de enxertos, uso da artéria torácica interna e revascularização completa]. Análise univariada e multivariada para o desfecho mortalidade intra-hospitalar foram realizadas. RESULTADOS: O tempo médio entre o IAM e a CRM foi de 3,8 ± 3 dias. A mortalidade global foi 19%. Na análise multivariada: idade > 65 anos [OR 16,5 (IC 1,8-152), P=0,013]~ CEC >108 minutos [OR 40 (IC 2,7-578), P=0,007], creatinina > 2 mg/dl [OR 35,5 (IC 1,7-740), P=0,021] e pressão pulmonar sistólica > 60 mmHg [OR 31(IC 1,6-591), P=0,022] foram preditores de mortalidade intra-hospitalar. CONCLUSÃO: Variáveis pré-operatórias clássicas como idade > 65 anos, creatinina > 2 mg/dl e pressão pulmonar sistólica > 60 mmHg foram preditoras de mortalidade intra-hospitalar nos pacientes operados de revascularização miocárdica na fase aguda do infarto.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Permanecem as controvérsias sobre a utilização de circulação extracorpórea (CEC) na cirurgia de revascularização miocárdica (CRM). O objetivo deste estudo foi avaliar o impacto do 2000 Bernstein Parsonnet (2000BP) e EuroSCORE (EU) para escolha de CEC na CRM. MÉTODOS: Foram submetidos à CRM 1.551 pacientes consecutivos. CEC foi utilizada em 1.121 (72,3%) pacientes. O desempenho do 2000BP e EU para a amostra foi avaliado mediante testes de calibração, discriminação e correlação. Para ambos os escores de risco, o aumento do valor do escore e a presença de CEC tiveram relação direta com maior chance de óbito (P<0,05). Portanto, com essas duas variáveis foi construído um modelo de regressão logística para cada escore de risco, com a finalidade de determinar em que valor do escore a presença de CEC aumenta significativamente a chance de óbito. RESULTADOS: A calibração, ao igual que a área abaixo da curva ROC para o grupo com CEC [2000BP=0,80; EU=0,78] e sem CEC [2000BP=0,81; EU=0,85] foram adequadas. A correlação de Spearman para os grupos com e sem CEC foi de 0,66 (P<0,001) e 0,62 (P<0,001), respectivamente. No 2000BP, para um valor>17,75, a presença de CEC aumentou a chance de óbito para 7,4 [IC95% (4,4-12,3), P<0,0001]. No EU, para um valor>4,5, a presença de CEC aumentou a chance de óbito para 5,4 [IC95% (3,3-9), P<0,0001]. CONCLUSÃO: Na tomada de decisões, o 2000BP>17,75 ou o EU>4,5 orientam a identificar pacientes que quando submetidos a CRM com CEC têm chance de óbito aumentada significativamente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Este estudo avaliou o desempenho hemodinâmico e as alterações miocárdicas decorrentes do emprego de dispositivos de assistência ventricular esquerda (DAVE), associado ou não à descompressão do ventrículo direito por meio de derivação cavo-pulmonar, sendo esses achados comparados ao emprego de assistência circulatória biventricular. MÉTODOS: Vinte e um suínos foram submetidos à indução de insuficiência cardíaca através de fibrilação ventricular, sendo a atividade circulatória mantida por DAVE durante 180 minutos. No grupo controle, foi apenas implantado o DAVE. No grupo derivação, além do DAVE foi realizada cirurgia de derivação cavo-pulmonar. No grupo biventricular, foi instituída assistência biventricular. Foram monitoradas as pressões intracavitárias por 3 horas de assistência e amostras do endocárdio dos dois ventrículos foram coletadas e analisadas à microscopia óptica e eletrônica. RESULTADOS: O lactato sérico foi significativamente menor no grupo biventricular (P=0,014). A diferença observada entre o fluxo do DAVE nos grupos derivação e controle (+55±14 ml/kg/min, P=0,072) não foi significativa, enquanto que o fluxo no grupo biventricular foi significativamente maior (+93±17 ml/kg/min, P=0,012) e se manteve estável durante o experimento. A pressão arterial média (PAM) se manteve constante apenas no grupo biventricular (P<0,001), que também apresentou diminuição significativa das pressões em câmaras direitas. Na análise ultraestrutural, notou-se menor presença edema miocárdico no ventrículo direito no grupo biventricular (P=0,017). CONCLUSÃO: Os resultados apresentados demonstram que o desempenho hemodinâmico da assistência ventricular esquerda associada à derivação cavo-pulmonar, neste modelo experimental, não foi superior ao observado com a assistência de ventrículo esquerdo isolada e não substituiu a assistência biventricular de maneira efetiva.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM: to assess the clinical evolution of patients hospitalized due to the first episode of Acute Coronary Syndrome (ACS) according to its clinical manifestation. METHODS: data were collected from 234 patients, hospitalized between May 2006 and July 2009 due to the first episode of an ACS, by consulting their medical records. RESULTS: 234 patients were hospitalized, 140 (59.8%) due to Acute Myocardial Infarction (AMI). In the group with AMI, 19.3% presented complications, against 12.8% in the group with Unstable Angina (UA) (p=0.19). Angioplasty levels were higher among patients with AMI than with UA (p=0.02) and coronary artery bypass graft surgery was more frequent among UA patients (p=0.03). The majority (227; 97%) survived after the coronary event. Among the seven patients who died during the hospitalization, four had AMI (2.9%) and three UA (3.2%). CONCLUSIONS: A larger number of complications were found among infarction victims and the accomplishment of coronary artery bypass graft surgery differed between the groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Estimar a prevalência da adesão ao seguimento nutricional ambulatorial pós-cirúrgico e avaliar sua associação com fatores selecionados em indivíduos submetidos à cirurgia bariátrica. MÉTODOS: Estudo de coorte retrospectiva com base na revisão de dados pós-operatórios de 241 prontuários de adultos submetidos à gastroplastia redutora com derivação em Y de Roux entre 2006 e 2008. Considerou-se aderente o indivíduo que compareceu a quatro ou mais consultas nutricionais nos 12 primeiros meses após a cirurgia. Para investigar a associação entre adesão ao seguimento nutricional e idade, sexo, estado conjugal, escolaridade, situação empregatícia, distância entre a residência e o hospital, estratégias para perda de peso no período pré-operatório, índice de massa corporal no pré-cirúrgico imediato, presença de comorbidades e duração da internação pós-operatória, foram calculadas razões de prevalência e utilizou-se regressão múltipla de Poisson. RESULTADOS: A prevalência de adesão foi de 56% (IC95%=49,7-62,3) nessa população predominantemente feminina (80,9%), com média de idade de 44,4 anos (DP=11,6) e de IMC pré-operatório de 47,2kg/m² (DP=6,2). Dos fatores estudados, somente a duração da internação pós-operatória igual ou superior a 6 dias mostrou-se significativamente associada à adesão após análise ajustada por sexo e idade (RP=1,46; IC95%=1,15-1,86). CONCLUSÃO: A prevalência de adesão encontrada foi semelhante às de estudos internacionais, mas baixa considerando-se 75% como referência. A maior adesão observada nos indivíduos com internação pós-operatória prolongada pode sugerir que o maior contato com a equipe multiprofissional aumente a percepção da necessidade de cuidados com a saúde em longo prazo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Background The diagnosis of ventilator-associated pneumonia (VAP) is a challenge, particularly after cardiac surgery. The use of biological markers of infection has been suggested to improve the accuracy of VAP diagnosis. We aimed to evaluate the usefulness of soluble triggering receptor expressed on myeloid cells (sTREM)-1 in the diagnosis of VAP following cardiac surgery. Methods This was a prospective observational cohort study of children with congenital heart disease admitted to the pediatric intensive care unit (PICU) after surgery and who remained intubated and mechanically ventilated for at least 24 hours postoperatively. VAP was defined by the 2007 Centers for Disease Control and Prevention criteria. Blood, modified bronchoalveolar lavage (mBAL) fluid and exhaled ventilator condensate (EVC) were collected daily, starting immediately after surgery until the fifth postoperative day or until extubation for measurement of sTREM-1. Results Thirty patients were included, 16 with VAP. Demographic variables, Pediatric Risk of Mortality (PRISM) and Risk Adjustment for Congenital Heart Surgery (RACHS)-1 scores, duration of surgery and length of cardiopulmonary bypass were not significantly diferent in patients with and without VAP. However, time on mechanical ventilation and length of stay in the PICU and in the hospital were significantly longer in the VAP group. Serum and mBAL fluid sTREM-1 concentrations were similar in both groups. In the VAP group, 12 of 16 patients had sTREM-1 detected in EVC, whereas it was undetectable in all but two patients in the non-VAP group over the study period (p = 0.0013) (sensitivity 0.75, specificity 0.86, positive predictive value 0.86, negative predictive value 0.75, positive likelihood ratio (LR) 5.25, negative LR 0.29). Conclusion Measurement of sTREM-1 in EVC may be useful for the diagnosis of VAP after cardiac surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Low level laser therapy (LLLT) is used in several applications, including the reduction of inflammatory processes. It might be used to prevent the systemic inflammatory response syndrome (SIRS), which some patients develop after cardiopulmonary bypass (CPB) surgery. The objectives of this study were to investigate light distribution inside blood, in order to implement the LLLT during CPB, and, through this study, to determine the best wavelength and the best way to perform the treatment. The blood, diluted to the same conditions of CPB procedure was contained inside a cuvette and an optical fiber was used to collect the scattered light. Two wavelengths were used: 632.8 nm and 820 nm. Light distribution in blood inside CPB tubes was also evaluated. Compared to the 820 nm light, the 632.8 nm light is scattered further away from the laser beam, turning it possible that a bigger volume of blood be treated. The blood should be illuminated through the smallest diameter CPB tube, using at least four distinct points around it, in only one cross section, because the blood is kept passing through the tube all the time and the whole volume will be illuminated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivos: Avaliar a equivalência da operação gastrectomia vertical com anel (GVA), em relação à operação gastroplastia vertical com anel e derivação gástrica em Y-de-Roux (DGA), na indução de perda ponderal e modificação da composição corporal em obesas mórbidas. Verificar os impactos laboratoriais e clínicos da GVA sobre as principais doenças associadas à obesidade mórbida, e a ocorrência de complicações, em comparação à DGA. Métodos: Ensaio clínico prospectivo não-randomizado, incluindo 65 mulheres obesas mórbidas, distribuídas em dois grupos, GVA (n = 33) e DGA (n = 32). Operadas consecutivamente, pelo mesmo cirurgião, por via laparotômica. Os parâmetros avaliados foram antropométricos; composição corporal, por meio de bioimpedância elétrica; laboratoriais; efeitos sobre as doenças pré-existentes e complicações. Resultados: Ocorreu perda de peso expressiva (p = 0,0000), redução do índice de massa corporal - IMC (p = 0,0000) e cintura abdominal (p = 0,0000) em ambos grupos. O índice cintura/quadril diminuiu (p = 0,0000) após ambas intervenções. A perda do excesso de IMC foi de 86,05% ± 14,2 no grupo GVA e 85,91 ± 15,71 no grupo DGA. A variação da gordura corporal foi de -35,84% ± 8,66 no grupo GVA e de -37,64% ± 9,62 no grupo DGA. A redução dos níveis de triglicerídios (p = 0,0222) foi mais expressiva no grupo DGA. O grupo DGA atingiu os alvos terapêuticos para o colesterol-LDL com maior freqüência (p = 0,0005), que o grupo GVA. Intolerância à glicose, diabetes mellitus tipo 2, hipertensão arterial sistêmica, esteatose hepática e síndrome metabólica, foram controladas de forma semelhante entre as técnicas. Anemia foi mais prevalente no grupo DGA (p=0,0033) e a esofagite erosiva, no grupo GVA (p = 0,0032). Não houve diferença na formação de cálculos biliares entre os grupos. Conclusões: A GVA é tão efetiva quanto a DGA em induzir perda ponderal e modificação favorável da composição corporal. A GVA é menos efetiva no controle da dislipidemia, em relação à DGA. GVA acarreta anemia em menor freqüência e, esofagite erosiva de maneira mais freqüente, que a DGA. GVA não é mais segura que a DGA, mas deve ser considerada intervenção bariátrica efetiva como segunda opção.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La sedimentazione clastica di mare profondo è attualmente uno dei principali argomenti della ricerca sedimentologica sia in ambito puramente accademico che in ambito petrolifero-industriale. Gli studi recenti hanno enfatizzato l'influenza fondamentale della topografia preesistente del fondo marino sulla crescita e la morfologia sui fan di mare profondo; si è visto come, in molti systemi torbiditici, l’evoluzione dei processi deposizionali sia stata da moderatamente a fortemente controllata dall’ effetto di confinamento di scarpate tettoniche, ridge strutturali e seamounts. Scopo di questo lavoro è studiare l'effetto del confinamento alla scala di bacino sui principali sistemi torbiditici del margine orientale della Sardegna che rappresenta un margine passivo articolato di bacini di intraslope confinati verso mare da seamounts. Lo studio dei sistemi deposizionali è stato eseguito attraverso l'interpretazione di dati di batimetria multibeam ad alto dettaglio acquisiti dall’ISMAR di Bologna durante la crociera Tir99. L’ interpretazione multibeam è stata integrata con l’ analisi di profili sismici a riflessione per comprendere la morfologia l’organizzazione interna e l’evoluzione nel tempo dei principali elementi deposizionali dei sistemi torbiditici. Tre bacini di intraslope (Olbia, Baronie e il settore settentrionale del bacino Ogliastra) sono stati investigati. Il bacino di Olbia è il bacino più settentrionale del margine orientale della Sardegna ed è limitato verso mare dai seamount Etruschi e Baronie. Il principale sistema torbiditico del bacino di Olbia è costituito dal Caprera, articolato in un sistema di canyon alimentatori nella piattaforma e nella scarpata continentale e da un ampio canale con argini alla base della scarpata. Il Caprera è fiancheggiato da un ampia piattaforma continentale, e questa, fungendo da “magazzino” per il materiale piu grossolando, può spiegare la peculiare architettura sedimentaria del suo fan. L'effetto di confinamento del bacino sulla forma e sull'evoluzione del fan del Caprera è evidente soprattutto sull'asimmetria dei leve e su fenomeni di avulsione che hanno coinvolto il canale. Il bacino di intraslope di Olbia appare completamente riempito, e, nel bordo orientale, è presente il canyon di intrabacino verso il bacino sottostante. Gli effetti dell'abbassamento del livello di base sono visibili nel settore distale del sistema, dove si ha lo sviluppo di canali distributari e di valli erosive a basso rilievo, che rappresentano le porzioni "upslope" dei canyon di "bypass". Il bacino di intraslope del Baronie è il bacino centrale del margine, confinato verso mare dal seamount delle Baronie, e presenta una via di fuga laterale rappresentato dal sistema di canyon di Gonone-Orosei. Il Posada è il sistema torbiditico principale, consiste di un canyon profondamente inciso nella piattaforma e nella scarpata, e sviluppa alla base della scarpata un piccolo fa radiale. La morfologia del è il risultato dell'interazione complessa tra la geoemtria del bacino ricevente ed il comportamento dei flussi sedimentari. La forma del bacino ha costretto il sistema torbiditico a cambiare la direzione di sviluppo, da est verso sud. Processi di framanento in massa a grande scala hanno inoltre contribuito alla riorganizzazione del sistema torbiditico. Il bacino dell’Ogliastra è localizzato nel settore meridionale del margine, limitato verso mare dal seamount Quirra. Il settore settentrionale della scarpata continentale del bacino Ogliastra è caratterizzato da canyon e incisioni di carattere ibrido, con tratti deposizionali ed erosivi. L'Arbatax è il principale sistema torbiditico del bacino di Ogliastra caratterizzato da un settore meridionale dominato da un canale alimentatore e da un settore settentrionale abbandonato, caratterizzato da fenomeni di smantellamento e instabilità gravitativa. In generale i risultati dello studio evidenziano l'importanza della combinazione dei fattori di controllo esterni, e della topografia preesistente, nello sviluppo dei processi sedimentari e degli elementi deposizionali dei sistemi torbiditici. In particolare, appare evidente come lo stile deposizionale dei sistemi torbiditici in ambiente confinato diverga sostanzialmente da quello previsto dai modelli di fan sottomarini usati come strumenti predittivi nella esplorazione e sfruttamento dei giacimenti di idrocarburi.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Attualmente le tematiche legate alla produzione e all’uso dell’energia rivestono grande importanza, anche in relazione agli obiettivi in termini di riduzione delle emissioni di gas partecipanti all’effetto serra prefissati dal Protocollo di Kyoto, che impongono il contenimento dei consumi energetici. Andando a ricercare i fattori che alterano i consumi energetici dei sistemi acquedottistici, accanto a quelli legati all’efficienza degli impianti e alle condizioni delle condotte, si deve tener conto anche della presenza delle perdite idriche in rete. Infatti nel valutare il problema delle perdite idriche esclusivamente come quantitativo di acqua di elevata qualità dispersa nell’ambiente, si trascura di considerare il contenuto energetico che ad essa viene conferito mediante attività di pompaggio durante le fasi di prelievo, potabilizzazione, adduzione e distribuzione all’utenza. L’efficienza invece varia in funzione di fattori oggettivi strettamente legati alle caratteristiche del territorio da servire, ma anche in funzione delle scelte effettuate in fase di progettazione e di esercizio. Da questa premessa discendono due importanti considerazioni. Il primo aspetto consiste nel poter valutare separatamente l’influenza sul consumo energetico dell’efficienza dei pompaggi e della rete, in modo da identificare l’impatto di singoli interventi, in particolare la riduzione delle perdite idriche (Colombo & Karney, 2002, 2004; Walski, 2004; Artina et al. 2007, 2008) ed il miglioramento dello stato dell’infrastruttura acquedottistica. Alla luce degli studi già svolti, sarà approfondita l’analisi del legame tra perdite idriche e aumento del consumo energetico, valutandola su modello numerico con riferimento a un caso di studio reale, costituito da un distretto monitorato della rete acquedottistica di Mirabello (Ferrara) alimentato mediante un sistema bypass-pompaggio a giri variabili. Il secondo aspetto riguarda la necessità di individuare dei termini di paragone che consentano di formulare un giudizio nei confronti del quantitativo di energia attualmente impiegato in un sistema acquedottistico. Su tale linea saranno analizzati alcuni indicatori per esprimere i consumi energetici dei sistemi acquedottistici.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Analisi del progetto di canale di bypass al bacino artificiale sul Torrente Conca (comune di Misano Adriatico). Richiami di teoria del trasporto solido. Simulazione del comportamento idraulico in moto vario del canale di bypass attraverso il programma HEC RAS. Verifiche di trasporto solido.