950 resultados para Buried pipes
Resumo:
Some death scene investigations commence without knowledge of the location of the body and/or decomposition site. In these cases, it is necessary to locate the remains or the site where the body decomposed prior to movement. We hypothesized that the burial of a mammalian cadaver will result in the release of ninhydrin reactive nitrogen (NRN) into associated soil and that this reaction might have potential as a tool for the identification of clandestine graves. Juvenile rat (Rattus rattus) cadavers were buried in three contrasting soil types in Australian tropical savanna ecosystems and allowed to decompose over a period of 28 days. Soils were sequentially harvested and analyzed for NRN. Cadaver burial resulted in an approximate doubling (mean = 1.7 ± 0.1) in the concentration of soil NRN. This reaction has great potential to be used as a presumptive test for gravesoil and this use might be greatly enhanced following more detailed research.
Resumo:
A controlled laboratory experiment is described, in principle and practice, which can be used for the of determination the rate of tissue decomposition in soil. By way of example, an experiment was conducted to determine the effect of temperature (12°C, 22°C) on the aerobic decomposition of skeletal muscle tissue (Organic Texel × Suffolk lamb (Ovis aries)) in a sandy loam soil. Measurements of decomposition processes included muscle tissue mass loss, microbial CO2 respiration, and muscle tissue carbon (C) and nitrogen (N). Muscle tissue mass loss at 22°C always was greater than at 12°C (p < 0.001). Microbial respiration was greater in samples incubated at 22°C for the initial 21 days of burial (p < 0.01). All buried muscle tissue samples demonstrated changes in C and N content at the end of the experiment. A significant correlation (p < 0.001) was demonstrated between the loss of muscle tissue-derived C (C1) and microbially-respired C (Cm) demonstrating CO2 respiration may be used to predict mass loss and hence biodegradation. In this experiment Q10 (12°C - 22°C) = 2.0. This method is recommended as a useful tool in determining the effect of environmental variables on the rate of decomposition of various tissues and associated materials.
Resumo:
We present one of the first studies of the use of Distributed Temperature Sensing (DTS) along fibre-optic cables to purposely monitor spatial and temporal variations in ground surface temperature (GST) and soil temperature, and provide an estimate of the heat flux at the base of the canopy layer and in the soil. Our field site was at a groundwater-fed wet meadow in the Netherlands covered by a canopy layer (between 0-0.5 m thickness) consisting of grass and sedges. At this site, we ran a single cable across the surface in parallel 40 m sections spaced by 2 m, to create a 40×40 m monitoring field for GST. We also buried a short length (≈10 m) of cable to depth of 0.1±0.02 m to measure soil temperature. We monitored the temperature along the entire cable continuously over a two-day period and captured the diurnal course of GST, and how it was affected by rainfall and canopy structure. The diurnal GST range, as observed by the DTS system, varied between 20.94 and 35.08◦C; precipitation events acted to suppress the range of GST. The spatial distribution of GST correlated with canopy vegetation height during both day and night. Using estimates of thermal inertia, combined with a harmonic analysis of GST and soil temperature, substrate and soil-heat fluxes were determined. Our observations demonstrate how the use of DTS shows great promise in better characterising area-average substrate/soil heat flux, their spatiotemporal variability, and how this variability is affected by canopy structure. The DTS system is able to provide a much richer data set than could be obtained from point temperature sensors. Furthermore, substrate heat fluxes derived from GST measurements may be able to provide improved closure of the land surface energy balance in micrometeorological field studies. This will enhance our understanding of how hydrometeorological processes interact with near-surface heat fluxes.
Resumo:
Searching for and mapping the physical extent of unmarked graves using geophysical techniques has proven difficult in many cases. The success of individual geophysical techniques for detecting graves depends on a site-by-site basis. Significantly, detection of graves often results from measured contrasts that are linked to the background soils rather than the type of archaeological feature associated with the grave. It is evident that investigation of buried remains should be considered within a 3D space as the variation in burial environment can be extremely varied through the grave. Within this paper, we demonstrate the need for a multi-method survey strategy to investigate unmarked graves, as applied at a “planned” but unmarked pauper’s cemetery. The outcome from this case study provides new insights into the strategy that is required at such sites. Perhaps the most significant conclusion is that unmarked graves are best understood in terms of characterization rather than identification. In this paper, we argue for a methodological approach that, while following the current trends to use multiple techniques, is fundamentally dependent on a structured approach to the analysis of the data. The ramifications of this case study illustrate the necessity of an integrated strategy to provide a more holistic understanding of unmarked graves that may help aid in management of these unseen but important aspects of our heritage. It is concluded that the search for graves is still a current debate and one that will be solved by methodological rather than technique-based arguments.
Resumo:
Virtual Pole from Magnetic Anomaly (VPMA) is a new multi-disciplinary methodology that estimates the age of a source rock from its magnetic anomaly, taken directly from available aeromagnetic data. The idea is to use those anomalies in which a strong remanent magnetic component is likely to occur. Once the total magnetization of the anomaly is computed through any of the currently available methods, the line that connects all virtual paleogeographic poles is related with the position, on a paleogeographic projection, of the appropriate age fragment of the APWT curve. We applied this procedure to five (5) well-known magnetic anomalies of the South American plate in SE Brazil, all of them associated to alkaline complexes of Mesozoic age. The apparent ages obtained from VPMA on three of the anomalies where the radiometric age of the source rock is known - Tapira, Araxa and Juquia were inside the error interval of the published ages. The VPMA apparent ages of the other two, where the age of the source rock is not known (Registro and Pariqueracu magnetic anomalies) were geologically coherent. We expect that the application of the VPMA methodology as a reconnaissance geochronological tool may contribute to geological knowledge over continental areas, especially when the source rocks of the magnetic anomalies am unknown or buried below superficial sediments. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The largest earthquake observed in the stable continental interior of the South American plate occurred in Serra do Tombador, Mato Grosso state - Brazil, on January 31,1955 with a magnitude of 6.2 m(b). Since then no other earthquake has been located near the 1955 epicentre. However, in Porto dos Gauchos, 100 km northeast of Serra do Tombador, a recurrent seismicity has been observed since 1959. Both Serra do Tombador and Porto dos Gauchos are located in the Phanerozoic Parecis basin. Two magnitude 5 earthquakes occurred in Porto dos Gauchos, in 1998 and 2005, with intensities up to VI and V, respectively. These two main shocks were followed by aftershock sequences lasting more than three years each. Local seismic stations have been deployed by the Seismological Observatory of the University of Brasilia since 1998 to study the ""Porto dos Gauchos"" seismic zone (PGSZ). A local seismic refraction survey was carried out with two explosions to help define the seismic velocity model. Both the 1998 and 2005 earthquake sequences occurred in the same WSW-ENE oriented fault zone with right-lateral strike-slip mechanisms. The epicentral zone is in the Parecis basin, near its northern border where there are buried grabens, generally trending WNW-ESE, such as the deep Mesoproterozoic Caiabis graben which lies partly beneath the Parecis basin. However, the epicentral distribution indicates that the 1998 and 2005 sequences are related to a N60 degrees E fault which probably crosses the entire Caiabis graben. The 1955 earthquake, despite the uncertainty in its epicentre, does not seem to be directly related to any buried graben either. The seismicity in the Porto dos Gauchos seismic zone, therefore, is not directly related to rifted crust. The probable direction of the maximum horizontal stress near Porto dos Gauchos is roughly E-W, consistent with other focal mechanisms further south in the Pantanal basin and Paraguay. but seems to be different from the NW-SE direction observed further north in the Amazon basin. The recurrent seismicity observed in Porto dos Gauchos, and the large 1955 earthquake nearby, make this area of the Parecis basin one of the most important seismic zones of Brazil. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Receiver functions from small local earthquakes were used to determine sediment thicknesses in Porto dos Gauchos seismic zone (PGSZ), Parecis basin, Amazonian craton, Brazil. The high velocity contrast between basement and sediments (P-wave velocities of 6.1 and 3.0 km/s, respectively) favors the generation of clear P-to-S converted phases (Ps) seen in the radial component, and also S-to-P conversions (Sp) seen in the vertical component. A reference 10 velocity model determined with shallow refraction experiment in PGSZ helped to convert Ps P time differences to basement depths at 15 stations deployed for aftershocks studies. The results of receiver function integrated with the shallow refraction reveal that the basement depths in the PGSZ increases from the basin border in the north up to about 600 m depth in the south. The basement topography, however, does not vary smoothly and a basement high with a steep topography was detected near the epicentral area. A 400 m elevation difference within 1.7 km distance suggests a possible border fault of a buried graben. This feature seems to be oriented roughly WSW-ENE and could indicate basement structures related to the seismicity of the Porto dos Gauchos Seismic Zone. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
GPR (Ground Penetrating Radar) results are shown for perpendicular broadside and parallel broadside antenna orientations. Performance in detection and localization of concrete tubes and steel tanks is compared as a function of acquisition configuration. The comparison is done using 100 MHz and 200 MHz center frequency antennas. All tubes and tanks are buried at the geophysical test site of IAG/USP in Sao Paulo city, Brazil. The results show that the long steel pipe with a 38-mm diameter was well detected with the perpendicular broadside configuration. The concrete tubes were better detected with the parallel broadside configuration, clearly showing hyperbolic diffraction events from all targets up to 2-m depth. Steel tanks were detected with the two configurations. However, the parallel broadside configuration was generated to a much lesser extent an apparent hyperbolic reflection corresponding to constructive interference of diffraction hyperbolas of adjacent targets placed at the same depth. Vertical concrete tubes and steel tanks were better contained with parallel broadside antennas, where the apexes of the diffraction hyperbolas better corresponded to the horizontal location of the buried target disposition. The two configurations provide details about buried targets emphasizing how GPR multi-component configurations have the potential to improve the subsurface image quality as well as to discriminate different buried targets. It is judged that they hold some applicability in geotechnical and geoscientific studies. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
A 2D steady model for the annular two-phase flow of water and steam in the steam-generating boiler pipes of a liquid metal fast breeder reactor is proposed The model is based on thin-layer lubrication theory and thin aerofoil theory. The exchange of mass between the vapour core and the liquid film due to evaporation of the liquid film is accounted for using some simple thermodynamics models, and the resultant change of phase is modelled by proposing a suitable Stefan problem Appropriate boundary conditions for the now are discussed The resulting non-lineal singular integro-differential equation for the shape of the liquid film free surface is solved both asymptotically and numerically (using some regularization techniques) Predictions for the length to the dryout point from the entry of the annular regime are made The influence of both the traction tau provided by the fast-flowing vapour core on the liquid layer and the mass transfer parameter eta on the dryout length is investigated
Resumo:
Some nuclear receptor (NR) ligands promote dissociation of radiolabeled bound hormone from the buried ligand binding cavity (LBC) more rapidly than excess unlabeled hormone itself This result was interpreted to mean that challenger ligands bind allosteric sites on the LBD to induce hormone dissociation, and recent findings indicate that ligands bind weakly to multiple sites on the LBD surface. Here we show, that a large fraction of thyroid hormone receptor (TR) ligands promote rapid dissociation (T(1/2) < 2 h) of , radiolabeled T(3) vs. T(3) (T(1/2), approximate to 5-7 h). We cannot discern relationships between this effect and ligand size, activity or affinity for TR beta. One ligand, GC-24, binds the TR LBC and (weakly) to the TR beta-LBD surface that mediates dimer/heterodimer interaction, but we cannot link this interaction to rapid T(3) dissociation. Instead, several lines of evidence suggest that the challenger ligand must interact with the buried LBC to promote rapid T(3) release. Since previous molecular dynamics simulations suggest that TR ligands leave the LBC by several routes, we propose that a subset of challenger ligands binds and stabilizes a partially unfolded intermediate state of TR that arises during T(3) release and that this effect enhances hormone dissociation. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Thyroid hormone receptors (TRs) are ligand-gated transcription factors with critical roles in development and metabolism. Although x-ray structures of TR ligand-binding domains (LBDs) with agonists are available, comparable structures without ligand (apo-TR) or with antagonists are not. It remains important to understand apo-LBD conformation and the way that it rearranges with ligands to develop better TR pharmaceuticals. In this study, we conducted hydrogen/deuterium exchange on TR LBDs with or without agonist (T(3)) or antagonist (NH(3)). Both ligands reduce deuterium incorporation into LBD amide hydrogens, implying tighter overall folding of the domain. As predicted, mass spectroscopic analysis of individual proteolytic peptides after hydrogen/deuterium exchange reveals that ligand increases the degree of solvent protection of regions close to the buried ligand-binding pocket. However, there is also extensive ligand protection of other regions, including the dimer surface at H10-H11, providing evidence for allosteric communication between the ligand-binding pocket and distant interaction surfaces. Surprisingly, C-terminal activation helix H12, which is known to alter position with ligand, remains relatively protected from solvent in all conditions suggesting that it is packed against the LBD irrespective of the presence or type of ligand. T(3), but not NH(3), increases accessibility of the upper part of H3-H5 to solvent, and we propose that TR H12 interacts with this region in apo-TR and that this interaction is blocked by T(3) but not NH(3.) We present data from site-directed mutagenesis experiments and molecular dynamics simulations that lend support to this structural model of apo-TR and its ligand-dependent conformational changes. (Molecular Endocrinology 25: 15-31, 2011)
Resumo:
The Borborema Province, in the NE of Brazil, is a rather complex piece in the Brazil-Africa puzzle as it represents the junction of the Dahomeyide/Pharusian, Central African, Aracuai and Brasilia fold belts located between the West-African/Sao Luis, Congo/Sao Francisco and Amazonas craton. The correlation between the Dahomeyides from W-Africa (Ghana, Benin, Togo, and Mali) and the Borborema Province involves the Medio Coreau and Central Ceara domains. The inferred continuation of the main oceanic suture zone exposed in the Dahomeyides of W Africa is buried beneath the Phanerozoic Parnaiba Basin in Brazil (northwest of the Medio Coreau domain) where some high density gravity anomalies may represent hidden remnants of an oceanic suture. In addition to this major suture a narrow, nearly continuous strip composed of mainly mafic pods containing relics of eclogite-facies assemblages associated with partially migmatized granulite-facies metapelitic gneisses has been found further east in the NW Borborema Province. These high pressure mafic rocks, interpreted as retrograded eclogites, are located between the Transbrasiliano Lineament and the Santa Quiteria continental arc and comprise primitive to evolved arc-related rocks with either arc- or MORB-type imprints that can indicate either deep subduction of oceanic lithosphere or roots of continental and oceanic magmatic arcs. Average peak P-T conditions under eclogite-facies metamorphism (T=770 degrees C and P = 17.3 kbar) were estimated using garnet-clinopyroxene thermometry and Jd content in clinopyroxene. Transition to granulite-facies conditions, as well as later widespread re-equilibration under amphibolite facies, were registered both in the basic and the metapelitic rocks and suggest a clockwise P-T path characterized by an increase in temperature followed by strong decompression. A phenomenon possibly related to the exhumation of a highly thickened crust associated with the suturing of the Medio Coreau and Central Ceara domains, two distinct crustal blocks separated by the Transbrasiliano Lineament. (C) 2009 International Association for Gondwana Research. Published by Elsevier B.V. All rights reserved.
Resumo:
The Granada ignimbrite, an Upper Miocene volcanic unit from the northern Puna, previously has been interpreted as an extensive ignimbrite (>2300 km(2)) associated with eruptions from the Vilama caldera (trap-door event). On the basis of new data, we revise its correlation and redefine the unit as a compound, high aspect ratio ignimbrite, erupted at approximately 9.8 Ma. Calculated volumes (similar to 100 km(3)) are only moderate in comparison with other large volume (>1000 km(3)) ignimbrites that erupted approximately 2-6 m.y. later in the region (e.g. Vilama, Panizos, Atana). Six new volcanic units are recognized from sequences previously correlated with Granada (only one sourced from the same center). Consequently, the area ascribed to the Granada ignimbrite is substantially reduced (630 km(2)), and links to the Vilama caldera are not supported. Transport directions suggest the volcanic source for the Granada ignimbrite corresponds to vents buried under younger (>= 7.9-5 Ma) volcanic rocks of the Abra Granada volcanic complex. Episodes of caldera collapse at some stage of eruption are likely, though their nature and timing cannot be defined from available data. The eruption of the Granada ignimbrite marks the onset of a phase of large volume (caldera-sourced) volcanism in the northern Puna. (C) 2007 Elsevier Ltd. All rights reserved.