988 resultados para Breast Reconstruction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

X-ray mammography has been the gold standard for breast imaging for decades, despite the significant limitations posed by the two dimensional (2D) image acquisitions. Difficulty in diagnosing lesions close to the chest wall and axilla, high amount of structural overlap and patient discomfort due to compression are only some of these limitations. To overcome these drawbacks, three dimensional (3D) breast imaging modalities have been developed including dual modality single photon emission computed tomography (SPECT) and computed tomography (CT) systems. This thesis focuses on the development and integration of the next generation of such a device for dedicated breast imaging. The goals of this dissertation work are to: [1] understand and characterize any effects of fully 3-D trajectories on reconstructed image scatter correction, absorbed dose and Hounsifeld Unit accuracy, and [2] design, develop and implement the fully flexible, third generation hybrid SPECT-CT system capable of traversing complex 3D orbits about a pendant breast volume, without interference from the other. Such a system would overcome artifacts resulting from incompletely sampled divergent cone beam imaging schemes and allow imaging closer to the chest wall, which other systems currently under research and development elsewhere cannot achieve.

The dependence of x-ray scatter radiation on object shape, size, material composition and the CT acquisition trajectory, was investigated with a well-established beam stop array (BSA) scatter correction method. While the 2D scatter to primary ratio (SPR) was the main metric used to characterize total system scatter, a new metric called ‘normalized scatter contribution’ was developed to compare the results of scatter correction on 3D reconstructed volumes. Scatter estimation studies were undertaken with a sinusoidal saddle (±15° polar tilt) orbit and a traditional circular (AZOR) orbit. Clinical studies to acquire data for scatter correction were used to evaluate the 2D SPR on a small set of patients scanned with the AZOR orbit. Clinical SPR results showed clear dependence of scatter on breast composition and glandular tissue distribution, otherwise consistent with the overall phantom-based size and density measurements. Additionally, SPR dependence was also observed on the acquisition trajectory where 2D scatter increased with an increase in the polar tilt angle of the system.

The dose delivered by any imaging system is of primary importance from the patient’s point of view, and therefore trajectory related differences in the dose distribution in a target volume were evaluated. Monte Carlo simulations as well as physical measurements using radiochromic film were undertaken using saddle and AZOR orbits. Results illustrated that both orbits deliver comparable dose to the target volume, and only slightly differ in distribution within the volume. Simulations and measurements showed similar results, and all measured dose values were within the standard screening mammography-specific, 6 mGy dose limit, which is used as a benchmark for dose comparisons.

Hounsfield Units (HU) are used clinically in differentiating tissue types in a reconstructed CT image, and therefore the HU accuracy of a system is very important, especially when using non-traditional trajectories. Uniform phantoms filled with various uniform density fluids were used to investigate differences in HU accuracy between saddle and AZOR orbits. Results illustrate the considerably better performance of the saddle orbit, especially close to the chest and nipple region of what would clinically be a pedant breast volume. The AZOR orbit causes shading artifacts near the nipple, due to insufficient sampling, rendering a major portion of the scanned phantom unusable, whereas the saddle orbit performs exceptionally well and provides a tighter distribution of HU values in reconstructed volumes.

Finally, the third generation, fully-suspended SPECT-CT system was designed in and developed in our lab. A novel mechanical method using a linear motor was developed for tilting the CT system. A new x-ray source and a custom made 40 x 30 cm2 detector were integrated on to this system. The SPECT system was nested, in the center of the gantry, orthogonal to the CT source-detector pair. The SPECT system tilts on a goniometer, and the newly developed CT tilting mechanism allows ±15° maximum polar tilting of the CT system. The entire gantry is mounted on a rotation stage, allowing complex arbitrary trajectories for each system, without interference from the other, while having a common field of view. This hybrid system shows potential to be used clinically as a diagnostic tool for dedicated breast imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is concern about the potential increase of hematological toxicity in elderly patients treated with chemotherapy. Recently, primary prophylaxis with colony-stimulating factors (CSFs) was proposed for elderly patients receiving moderately toxic chemotherapy. However, evidence for the benefits of this primary prophylaxis for elderly breast cancer patients is currently lacking. We retrospectively analyzed the incidence of febrile neutropenia (FN) and neutropenic infections in elderly breast cancer patients receiving anthracycline-based chemotherapy without primary prophylaxis with colony-stimulating factors. In addition, we assessed the direct costs of hospitalization for these complications. Febrile neutropenia or neutropenic infection occurred in 13% of the 46 patients. Further studies are needed to adequately evaluate the risk of neutropenic complications (NC) in elderly patients receiving standard-dose chemotherapy for breast cancer and the potential benefits of primary prophylaxis with colony-stimulating factors. © 2004 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A distinctive subset of metastatic breast cancer (MBC) is oligometastatic disease, which is characterized by single or few detectable metastatic lesions. The existing treatment guidelines for patients with localized MBC include surgery, radiotherapy, and regional chemotherapy. The European School of Oncology-Metastatic Breast Cancer Task Force addressed the management of these patients in its first consensus recommendations published in 2007. The Task Force endorsed the possibility of a more aggressive and multidisciplinary approach for patients with oligometastatic disease, stressing also the need for clinical trials in this patient population. At the sixth European Breast Cancer Conference, held in Berlin in March 2008, the second public session on MBC guidelines addressed the controversial issue of whether MBC can be cured. In this commentary, we summarize the discussion and related recommendations regarding the available therapeutic options that are possibly associated with cure in these patients. In particular, data on local (surgery and radiotherapy) and chemotherapy options are discussed. Large retrospective series show an association between surgical removal of the primary tumor or of lung metastases and improved long-term outcome in patients with oligometastatic disease. In the absence of data from prospective randomized studies, removal of the primary tumor or isolated metastatic lesions may be an attractive therapeutic strategy in this subset of patients, offering rapid disease control and potential for survival benefit. Some improvement in outcome may also be achieved with optimization of systemic therapies, possibly in combination with optimal local treatment. © 2010. Published by Oxford University Press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

info:eu-repo/semantics/published

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have recently demonstrated that physiological levels of androgens exert direct and potent inhibitory effects on the growth of human breast cancer ZR-75-1 cells in vivo in nude mice as well as in vitro under both basal and estrogen-stimulated conditions. The inhibitory effect of androgens has also been confirmed on the growth of dimethylbenz(a)anthracene (DMBA)-induced mammary carcinoma in the rat. Such observations are in close agreement with the clinical data showing that androgens and the androgenic compound medroxyprogesterone acetate (MPA) have beneficial effects in breast cancer in women comparable to other endocrine therapies, including tamoxifen. Although the inhibitory action of androgens on cell proliferation in estrogen-induced ZR-75-1 cells results, in part, from their suppressive effect on expression of the estrogen receptor, the androgens also exert a direct inhibitory effect independent of estrogens. Androgens cause a global slowing effect on the duration of the cell cycle. These observations support clinical data showing that androgenic compounds induce an objective remission after failure of antiestrogen therapy as well as those indicating that the antiproliferative action of androgens is additive to that of antiestrogens. We have also recently demonstrated in ZR-75-1 human breast cancer cells the antagonism between androgens and estrogens on the expression of GCDFP-15 and GCDFP-24 which are two major proteins secreted in human gross cystic disease fluid. The effects of androgens and estrogens as well as those of progestins and glucocorticoids on GCDFP-15 and GCDFP-24 mRNA levels and secretion are opposite to those induced by the same steroids on cell growth in ZR-75-1 cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper studies the possibility of distinguishing between benign and malignant masses by exploiting the morphology-dependent temporal and spectral characteristics of their microwave backscatter response in ultra-wideband breast cancer detection. The spiculated border profiles of 2-D breast masses are generated by modifying the baseline elliptical rings based upon the irregularity of their peripheries. Furthermore, the single- and multilayer lesion models are used to characterize a distinct mass region followed by a sharp transition to background, and a blurred mass border exhibiting a gradual transition to background, respectively. Subsequently, the complex natural resonances (CNRs) of the backscatter microwave signature can be derived from the late-time target response and reveal diagnostically useful information. The fractional sequence CLEAN algorithm is proposed to estimate the lesions' delay intervals and identify the late-time responses. Finally, it is shown through numerical examples that the locations of dominant CNRs are dependent on the lesion morphologies, where 2-D computational breast phantoms with single and multiple lesions are investigated. The analysis is of potential use for discrimination between benign and malignant lesions, where the former usually possesses a better-defined, more compact shape as opposed to the latter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulse design is investigated for time-reversal (TR) imaging as applied to ultrawideband (UWB) breast cancer detection. Earlier it has been shown that a suitably-designed UWB pulse may help to improve imaging performance for a single-tumor breast phantom with predetermined lesion properties. The current work considers the following more general and practical situations: presence of multiple malignancies with unknown tumor size and dielectric properties. Four pulse selection criteria are proposed with each focusing on one of the following aspects: eliminating signal clutter generated by tissue inhomogeneities, canceling mutual interference among tumors, improving image resolution, and suppressing artifacts created by sidelobe of the target response. By applying the proposed criteria, the shape parameters of UWB waveforms with desirable characteristics are identified through search of all the possible pulses. Simulation example using a numerical breast phantom, comprised of two tumors and structured clutter distribution, demonstrates the effectiveness of the proposed approach. Specifically, a tradeoff between the image resolution and signal-to-clutter contrast (SCC) is observed in terms of selection of the excitation waveforms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To examine the concentrations of zinc and omega-6 polyunsaturated fatty acids (omega-6 PUFAs) in breast milk, the impact of zinc on omega-6 PUFA metabolism, and the growth rate of infants. METHODS: Forty-one mother-term infant pairs from a rural area of northern Beijing, China, who were 1 month (n = 18, group I) and 3 months (n = 23, group II) old and exclusively breastfed, were studied. The dietary records and the concentrations of zinc and omega-6 PUFAs in the milk of lactating women and the increase in weight and length of their infants during 1 and 3 postnatal months were analysed. RESULTS: The dietary intakes of mothers in the two groups were the same, i.e. high in carbohydrate and low in fat, protein and energy. The maternal zinc intake was 7.5mg/d and thus reached only 34.6% of the current Recommended Nutrient Intake (RNI). The levels of zinc and arachidonic acid (AA, C20:4 omega-6) in the milk of group I were significantly higher than those in group II. Furthermore, significant positive correlations were found between the concentrations of zinc and AA in the breast milk and between the level of milk AA and weight gain. CONCLUSION: Zinc may be a co-factor and essential for essential fatty acids (EFA) metabolism. Thus suboptimal zinc intake may cause EFA imbalance. Further studies of Chinese rural mother-infant pairs are necessary to determine whether zinc supplementation should be recommended when lactation exceeds 3 months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) represents an established method for the detection and diagnosis of breast lesions. While mass-like enhancing lesions can be easily categorized according to the Breast Imaging Reporting and Data System (BI-RADS) MRI lexicon, a majority of diagnostically challenging lesions, the so called non-mass-like enhancing lesions, remain both qualitatively as well as quantitatively difficult to analyze. Thus, the evaluation of kinetic and/or morphological characteristics of non-masses represents a challenging task for an automated analysis and is of crucial importance for advancing current computer-aided diagnosis (CAD) systems. Compared to the well-characterized mass-enhancing lesions, non-masses have no well-defined and blurred tumor borders and a kinetic behavior that is not easily generalizable and thus discriminative for malignant and benign non-masses. To overcome these difficulties and pave the way for novel CAD systems for non-masses, we will evaluate several kinetic and morphological descriptors separately and a novel technique, the Zernike velocity moments, to capture the joint spatio-temporal behavior of these lesions, and additionally consider the impact of non-rigid motion compensation on a correct diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acknowledgements: I thank Dr. Barbour Warren, arriet Richardson and Alison James for their helpful input.