943 resultados para Biotechnology laboratories


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Architecture today often is praised for its tectonics, floating volumes, and sensational, gravity-defying stunts of “starchitecture.” Yet, very so often there is a building that inspires descriptions of the sublime, the experiential, and the power of light and architecture to transcend our expectations. The new Meinel Optical Sciences Research Building, designed by Phoenix-based Richärd+Bauer for the University of Arizona, Tucson, is one of these architectural rarities. Already drawing comparisons to Louis Kahn's 1965 Salk Institute for Biological Studies in La Jolla, California, the indescribable quality of light that characterizes the best of Kahn's work also resonates in Richärd+Bauer's new building. Both an expansion and renovation of the existing College of Optical Sciences facilities, the Meinel building includes teaching and research laboratories, six floors of offices, discussion areas, conference rooms, and an auditorium. The new 47,000 square-foot cast-in-place concrete structure, wrapped on three-sides in copper-alloy panels, harmonizes with the largely brick vocabulary of the campus while reflecting the ethereal quality of the wide Arizona sky. The façade, however, is merely a prelude for what awaits inside—where light and architecture seamlessly combine to create moments of pure awe.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recognized around the world as a powerful beacon for freedom, hope, and opportunity, the Statue of Liberty's light is not just metaphorical: her dramatic illumination is a perfect example of American ingenuity and engineering. Since the statue's installation in New York Harbor in 1886, lighting engineers and designers had struggled to illuminate the 150-foot copper-clad monument in a manner becoming an American icon. It took the thoughtful and creative approach of Howard Brandston-a legend in his own right-to solve this lighting challenge. In 1984, the designer was asked to give the statue a much-needed lighting makeover in preparation for its centennial. In order to avoid the shortcomings of previous attempts, he studied the monument from every angle and in all lighting conditions, discovering that it looked best in the light of dawn. Brandston determined that he would need 'one lamp to mimic the morning sun and one lamp to mimic the morning sky.' Learning that no existing lamps could simulate these conditions, Brandston partnered with General Electric to develop two new metal halide products. With only a short time for R&D, a team of engineers at GE's Nela Park laboratories assembled a 'top secret' testing room dedicated to the Statue of Liberty project. After nearly two years of work to perfect the new lamps, the 'dawn's early light' effect was finally achieved just days before the centennial celebrations were to take place in 1986. 'It was truly a labor of love,' he recalls.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The geomagnetic field is one of the most fundamental geophysical properties of the Earth and has significantly contributed to our understanding of the internal structure of the Earth and its evolution. Paleomagnetic and paleointensity data have been crucial in shaping concepts like continental drift, magnetic reversals, as well as estimating the time when the Earth's core and associated geodynamo processes begun. The work of this dissertation is based on reliable Proterozoic and Holocene geomagnetic field intensity data obtained from rocks and archeological artifacts. New archeomagnetic field intensity results are presented for Finland, Estonia, Bulgaria, Italy and Switzerland. The data were obtained using sophisticated laboratory setups as well as various reliability checks and corrections. Inter-laboratory comparisons between three laboratories (Helsinki, Sofia and Liverpool) were performed in order to check the reliability of different paleointensity methods. The new intensity results fill up considerable gaps in the master curves for each region investigated. In order to interpret the paleointensity data of the Holocene period, a novel and user-friendly database (GEOMAGIA50) was constructed. This provided a new tool to independently test the reliability of various techniques and materials used in paleointensity determinations. The results show that archeological artifacts, if well fired, are the most suitable materials. Also lavas yield reliable paleointensity results, although they appear more scattered. This study also shows that reliable estimates are obtained using the Thellier methodology (and its modifications) with reliability checks. Global paleointensity curves during Paleozoic and Proterozoic have several time gaps with few or no intensity data. To define the global intensity behavior of the Earth's magnetic field during these times new rock types (meteorite impact rocks) were investigated. Two case histories are presented. The Ilyinets (Ukraine) impact melt rocks yielded a reliable paleointensity value at 440 Ma (Silurian), whereas the results from Jänisjärvi impact melts (Russian Karelia, ca. 700 Ma) might be biased towards high intensity values because of non-ideal magnetic mineralogy. The features of the geomagnetic field at 1.1 Ga are not well defined due to problems related to reversal asymmetries observed in Keweenawan data of the Lake Superior region. In this work new paleomagnetic, paleosecular variation and paleointensity results are reported from coeval diabases from Central Arizona and help understanding the asymmetry. The results confirm the earlier preliminary observations that the asymmetry is larger in Arizona than in Lake Superior area. Two of the mechanisms proposed to explain the asymmetry remain plausible: the plate motion and the non-dipole influence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Oxygen transfer rate and the corresponding power requirement to operate the rotor are vital for design and scale-up of surface aerators. Present study develops simulation or scale-up criterion correlating the oxygen transsimulation fer coefficient and power number along with a parameter governing theoretical power per unit volume (X, which is defined as equal to (FR1/3)-R-4/3, where F and R are impellers' Fronde and Reynolds number, respectively). Based on such scale-up criteria, design considerations are developed to save energy requirements while designing square tank surface aerators. It has been demonstrated that energy can be saved substantially if the aeration tanks are run at relatively higher input powers. It is also demonstrated that smaller sized tanks are more energy conservative and economical when compared to big sized tanks, while aerating the same volume of water, and at the same time by maintaining a constant input power in all the tanks irrespective of their size. An example illustrating how energy can be reduced while designing different sized aerators is given. The results presented have a wide application in biotechnology and bioengineering areas with a particular emphasis on the design of appropriate surface aeration systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Oxygen transfer rate and the corresponding power requirement to operate the rotor are vital for design and scale-up of surface aerators. Present study develops simulation or scale-up criterion correlating the oxygen transsimulation fer coefficient and power number along with a parameter governing theoretical power per unit volume (X, which is defined as equal to (FR1/3)-R-4/3, where F and R are impellers' Fronde and Reynolds number, respectively). Based on such scale-up criteria, design considerations are developed to save energy requirements while designing square tank surface aerators. It has been demonstrated that energy can be saved substantially if the aeration tanks are run at relatively higher input powers. It is also demonstrated that smaller sized tanks are more energy conservative and economical when compared to big sized tanks, while aerating the same volume of water, and at the same time by maintaining a constant input power in all the tanks irrespective of their size. An example illustrating how energy can be reduced while designing different sized aerators is given. The results presented have a wide application in biotechnology and bioengineering areas with a particular emphasis on the design of appropriate surface aeration systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aeration experiments were conducted in different sized baffled and unbaffled circular surface aeration tanks to study their relative performance on oxygen transfer process while aerating the same volume of water. Experiments were carried out with the objective of ascertaining the effect of baffle on oxygen transfer coefficient k. Simulation equations govern the oxygen transfer coefficient with the theoretical power per unit volume, X and actual power per unit volume, P-V. It has been found that, for any given X, circular tanks with baffle produce higher values of k than unbaffled circular tanks, but in terms of actual power consumption unbaffled tanks consume less power when compared to baffled circular tanks to achieve the same value of k. It has been found that in terms of energy consumption, epsilon, baffled tanks consume more energy than unbaffled tanks at any value of X. This suggests that the unbaffled circular tank gives a better performance as far as energy consumption is concerned and hence better economy. An example illustrating the energy conservation to aerate the same volume of water in both types of aerators is given. (c) 2007 Society of Chemical Industry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Black hole X-ray binaries, binary systems where matter from a companion star is accreted by a stellar mass black hole, thereby releasing enormous amounts of gravitational energy converted into radiation, are seen as strong X-ray sources in the sky. As a black hole can only be detected via its interaction with its surroundings, these binary systems provide important evidence for the existence of black holes. There are now at least twenty cases where the measured mass of the X-ray emitting compact object in a binary exceeds the upper limit for a neutron star, thus inferring the presence of a black hole. These binary systems serve as excellent laboratories not only to study the physics of accretion but also to test predictions of general relativity in strongly curved space time. An understanding of the accretion flow onto these, the most compact objects in our Universe, is therefore of great importance to physics. We are only now slowly beginning to understand the spectra and variability observed in these X-ray sources. During the last decade, a framework has developed that provides an interpretation of the spectral evolution as a function of changes in the physics and geometry of the accretion flow driven by a variable accretion rate. This doctoral thesis presents studies of two black hole binary systems, Cygnus~X-1 and GRS~1915+105, plus the possible black hole candidate Cygnus~X-3, and the results from an attempt to interpret their observed properties within this emerging framework. The main result presented in this thesis is an interpretation of the spectral variability in the enigmatic source Cygnus~X-3, including the nature and accretion geometry of its so-called hard spectral state. The results suggest that the compact object in this source, which has not been uniquely identified as a black hole on the basis of standard mass measurements, is most probably a massive, ~30 Msun, black hole, and thus the most massive black hole observed in a binary in our Galaxy so far. In addition, results concerning a possible observation of limit-cycle variability in the microquasar GRS~1915+105 are presented as well as evidence of `mini-hysteresis' in the extreme hard state of Cygnus X-1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The need for mutual recognition of accurate measurement results made by competent laboratories has been very widely accepted at the international level e.g., at the World Trade Organization. A partial solution to the problem was made by the International Committee for Weights and Measures (CIPM) in setting up the Mutual Recognition Arrangement (CIPM MRA), which was signed by National Metrology Institutes (NMI) around the world. The core idea of the CIPM MRA is to have global arrangements for the mutual acceptance of the calibration certificates of National Metrology Institutes. The CIPM MRA covers all the fields of science and technology for which NMIs have their national standards. The infrastructure for the metrology of the gaseous compounds carbon monoxide (CO), nitrogen monoxide (NO), nitrogen dioxide (NO2), sulphur dioxide (SO2) and ozone (O3) has been constructed at the national level at the Finnish Meteorological Institute (FMI). The calibration laboratory at the FMI was constructed for providing calibration services for air quality measurements and to fulfil the requirements of a metrology laboratory. The laboratory successfully participated, with good results, in the first comparison project, which was aimed at defining the state of the art in the preparation and analysis of the gas standards used by European metrology institutes and calibration laboratories in the field of air quality. To confirm the competence of the laboratory, the international external surveillance study was conducted at the laboratory. Based on the evidence, the Centre for Metrology and Accreditation (MIKES) designated the calibration laboratory at the Finnish Meteorological Institute (FMI) as a National Standard Laboratory in the field of air quality. With this designation, the MIKES-FMI Standards Laboratory became a member of CIPM MRA, and Finland was brought into the internationally-accepted forum in the field of gas metrology. The concept of ‘once measured - everywhere accepted’ is the leading theme of the CIPM MRA. The calibration service of the MIKES-FMI Standards Laboratory realizes the SI traceability system for the gas components, and is constructed to enable it to meet the requirements of the European air quality directives. In addition, all the relevant uncertainty sources that influence the measurement results have been evaluated, and the uncertainty budgets for the measurement results have been created.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis presents a novel application of x-ray Compton scattering to structural studies of molecular liquids. Systematic Compton-scattering experiments on water have been carried out with unprecedented accuracy at third-generation synchrotron-radiation laboratories. The experiments focused on temperature effects in water, the water-to-ice phase transition, quantum isotope effects, and ion hydration. The experimental data is interpreted by comparison with both model computations and ab initio molecular-dynamics simulations. Accordingly, Compton scattering is found to provide unique intra- and intermolecular structural information. This thesis thus demonstrates the complementarity of the technique to traditional real-space probes for studies on the local structure of water and, more generally, molecular liquids.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The esterification of propionic acid was investigated using three different alcohols, namely, isopropyl alcohol, isobutyl alcohol, and isoamyl alcohol. The variation of conversion with time for the synthesis of isoamyl propionate was investigated in the presence of five enzymes. Novozym 435 showed the highest activity, and this was used as the enzyme for investigating the various parameters that influence the esterification reaction. The Ping-Pong Bi-Bi model with inhibition by both acid and alcohol was used to model the experimental data and determine the kinetics of the esterification reaction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The crystal structures of four peptides incorporating 1-aminocycloheptane-1-carboxylic acid (Ac7c) are described. Boc-Aib-Ac7c-NHMe and Boc-Pro-Ac7c-Ala-OMe adopt beta-turn conformations stabilized by an intramolecular 4----1 hydrogen bond, the former folding into a type-I/III beta-turn and the latter into a type-II beta-turn. In the dipeptide esters, Boc-Aib-Ac7c-OMe and Boc-Pro-Ac7c-OMe, the Ac7c and Aib residues adopt helical conformations, while the Pro residue remains semi-extended in both the molecules of Boc-Pro-Ac7c-OMe found in the asymmetric unit. The cycloheptane ring of Ac7c residues adopts a twist-chair conformation in all the peptides studied. 1H-NMR studies in CDCl3 and (CD3)2SO and IR studies in CDCl3 suggest that Boc-Aib-Ac7c-NHMe and Boc-Pro-Ac7c-Ala-OMe maintain the beta-turn conformations in solution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transmembrane channel-forming polypeptides can function as uncouplers of mitochondrial oxidative phosphorylation. The observed effects are dependent on the phosphate ion (Pi) concentration in the medium. At low Pi (2.5 mM) the order of uncoupling efficiencies is gramicidin A much greater than alamethicin greater than tetraacetyl melittin greater than melittin. The remarkably high activity of gramicidin A suggests insertion of preformed channel dimers into the membrane. It is also suggested that lipid phase association of peptides is necessary in the other cases. At Pi = 100 mM inhibitory effects are observed for alamethicin and tetraacetyl melittin. Less pronounced inhibition is seen for melittin, while no such effect is noted for gramicidin A. The site of inhibition is shown to be complex IV, and the differences in the behavior of the peptides are rationalized in terms of channel structures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The structures of two crystal forms of Boc-Trp-Ile-Ala-Aib-Ile-Val-Aib-Leu-Aib-Pro-OMe have been determined. The triclinic form (P1, Z = 1) from DMSO/H2O crystallizes as a dihydrate (Karle, Sukumar & Balaram (1986) Proc, Natl, Acad. Sci. USA 83, 9284-9288). The monoclinic form (P2(1), Z = 2) crystallized from dioxane is anhydrous. The conformation of the peptide is essentially the same in both crystal system, but small changes in conformational angles are associated with a shift of the helix from a predominantly alpha-type to a predominantly 3(10)-type. The r.m.s. deviation of 33 atoms in the backbone and C beta positions of residues 2-8 is only 0.29 A between molecules in the two polymorphs. In both space groups, the helical molecules pack in a parallel fashion, rather than antiparallel. The only intermolecular hydrogen bonding is head-to-tail between helices. There are no lateral hydrogen bonds. In the P2(1) cell, a = 9.422(2) A, b = 36.392(11) A, c = 10.548(2) A, beta = 111.31(2) degrees and V = 3369.3 A for 2 molecules of C60H97N11O13 per cell.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the crystal, the backbone of Boc-(Aib-Val-Ala-Leu)2-Aib-OMe adopts a helical form with four alpha-type hydrogen bonds in the middle, flanked by 3(10)-type hydrogen bonds at either end. The helical molecules stack in columns with head-to-tail hydrogen bonds, either directly between NH and CO, or bridged by solvent molecules. The packing of the helices is parallel, even in space group P2(1). Cell parameters are a = 9.837(2) A, b = 15.565(3) A, c = 20.087(5) A, beta = 96.42(2) degrees, dcalc = 1.091 g/cm3 for C46H83N9O12.1.5H2O.0.67CH3OH. There appears to be some hydration of the backbone in this apolar helix.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The conformationally restricted CHO-L-Met-Xxx-L-Phe-OY (where Xxx = Aib, Ac3c, Ac5c, Ac6c, and Ac7c; Y = H, Me) tripeptides, analogs of the chemoattractant CHO-L-Met-L-Leu-L-Phe-OH, have been synthesized in solution by classical methods and fully characterized. Compounds were compared to determine the combined effect of backbone conformational preferences and side-chain bulkiness on the relation of three-dimensional structure to biological activity. Each peptide was tested for its ability to induce granule enzyme secretion from rabbit peritoneal polymorphonuclear leukocytes. In parallel, a conformational analysis on the CHO-blocked peptide and their tertbutyloxycarbonylated synthetic precursors was performed in the crystal state and in solution using X-ray diffraction, infrared absorption, and 1H nuclear magnetic resonance. The biological and conformational data are discussed in relation to the proposed model of the chemotactic peptide receptor of rabbit neutrophils.