999 resultados para Bimolecular fluorescence complementation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

​2-Aminopurine (​2AP) is a fluorescent isomer of ​adenine and has a fluorescence lifetime of ~11 ns in water. It is widely used in biochemical settings as a site-specific fluorescent probe of DNA and RNA structure and base-flipping and -folding. These assays assume that ​2AP is intrinsically strongly fluorescent. Here, we show this not to be the case, observing that gas-phase, jet-cooled ​2-aminopurine and ​9-methyl-2-aminopurine have very short fluorescence lifetimes (156 ps and 210 ps, respectively); they are, to all intents and purposes, non-fluorescent. We find that the lifetime of ​2-aminopurine increases dramatically when it is part of a hydrate cluster, 2AP·(H2O)n, where n = 1–3. Not only does it depend on the presence of water molecules, it also depends on the specific hydrogen-bonding site to which they attach and on the number of H2O molecules at that site. We selectively microhydrate ​2-aminopurine at its sugar-edge, cis-amino or trans-amino sites and see that its fluorescence lifetime increases by 4, 50 and 95 times (to 14.5 ns), respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM To evaluate the performance of a pen‑type laser fluorescence device (DIAGNOdent 2190; LFpen, KaVo, Germany) and bitewing radiographs (BW) for approximal caries detection in permanent and primary teeth. MATERIALS AND METHODS A total of 246 anterior approximal surfaces (102 permanent and 144 primary) were selected. Contact points were simulated using sound teeth. Two examiners assessed all approximal surfaces using LFpen and BW. The teeth were histologically assessed for the reference standard. Optimal cut‑off limits were calculated for LFpen for primary and permanent teeth. Sensitivity, specificity, accuracy and area under the receiver operating characteristic curve (Az) were calculated for D1 (enamel and dentin lesions) and D3 (dentin lesions) thresholds. The reproducibility was assessed by intraclass correlation coefficient (ICC) and Cohen's weighted kappa values. RESULTS For permanent teeth, the LFpen cut‑off were 0- 27 (sound), 28- 33 (enamel caries) and >33 (dentin caries). For primary teeth, the LFpen cut‑off were 0- 7 (sound), 8- 32 (enamelcaries) and >32 (dentin caries). The LFpen presented higher sensitivity values than BW for primary teeth (0.58 vs. 0.32 at D1 and 0.80 vs. 0.47 at D3) and permanent teeth (0.80 vs. 0.57 at D1 and 0.94 vs. 0.51 at D3). Specificity did not show a significant difference between the methods. Rank correlations with histology were 0.59 and 0.83 (LFpen) and 0.36 and 0.70 (BW) for primary and permanent teeth, respectively, considering all lesions. ICC values for LFpen were 0.71 (inter) and 0.86 (intra) for permanent teeth and 0.94 (inter) and 0.90/0.99 for primary teeth. Kappa values for BW were 0.69 (inter) and 0.68/0.90 (intra) for permanent teeth and 0.64 (inter) and 0.89/0.89 for primary teeth. CONCLUSION LFpen presented better reproducibility for primary and permanent teeth and higher accuracy in detecting caries lesions at D1 threshold than BW for permanent teeth. LFpen should be used as an adjunct method for approximal caries detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Fluorescence lifetime imaging ophthalmoscopy is a technique to measure decay times of endogenous retinal fluorophores. The purpose of this study was to investigate fluorescence lifetimes in eyes with central and branch retinal artery occlusion. METHODS Twenty-four patients with central or branch retinal artery occlusion were included in this study. The contralateral unaffected fellow eye was used as control. Measurements were performed using a fluorescence lifetime imaging ophthalmoscope based on a HRA Spectralis system. Fluorescence excitation wavelength was 473 nm, and mean lifetimes were measured in a short (498-560 nm) and in a long (560-720 nm) spectral channel. Fluorescence lifetimes in the area of retinal artery occlusion were measured and compared to corresponding areas in contralateral unaffected eyes. Additionally, findings were correlated to optical coherence tomography measurements. RESULTS Retinal lifetime images of 24 patients with retinal artery occlusion were analyzed. Mean retinal fluorescence lifetimes were prolonged by 50% in the short and 20% in the long spectral channel in ischemic retinal areas up to 3 days after retinal artery occlusion compared to the contralateral unaffected eyes. In the postacute disease stage there was no difference between the lifetimes of affected areas and unaffected fellow eyes. CONCLUSIONS Retinal artery occlusion leads to significantly longer fluorescence lifetimes of the retina in the acute phase and may serve as a useful indicator for acute ischemic retinal damage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have cloned the complete coding region of the porcine TNFSF10 gene. The porcine TNFSF10 cDNA has an ORF of 870 nucleotides and shares 85% identity with human TNFSF10, and 75% and 72% identity with rat and mouse Tnfsf10 coding sequences, respectively. The deduced porcine TNFSF10 protein consists of 289 amino acids with the calculated molecular mass of 33.5 kDa and a predicted pI of 8.15. The amino acid sequence similarities correspond to 86, 72 and 70% when compared with human, rat and mouse sequences, respectively. Northern blot analysis detected TNFSF10-specific transcripts (approximately 1.7 kb) in various organs of a 10-week-old pig, suggesting ubiquitous expression. Real-time RT-PCR studies of various organs from fetal (days 73 and 98) and postnatal stages (two weeks, eight months) demonstrated developmental and tissue-specific regulation of TNFSF10 mRNA abundance. The chromosomal location of the porcine TNFSF10 gene was determined by FISH of a specific BAC clone to metaphase chromosomes. This TNFSF10 BAC clone has been assigned to SSC13q34-->q36. Additionally, the localization of the TNFSF10 gene was verified by RH mapping on the porcine IMpRH panel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although there has been a significant decrease in caries prevalence in developed countries, the slower progression of dental caries requires methods capable of detecting and quantifying lesions at an early stage. The aim of this study was to evaluate the effectiveness of fluorescence-based methods (DIAGNOdent 2095 laser fluorescence device [LF], DIAGNOdent 2190 pen [LFpen], and VistaProof fluorescence camera [FC]) in monitoring the progression of noncavitated caries-like lesions on smooth surfaces. Caries-like lesions were developed in 60 blocks of bovine enamel using a bacterial model of Streptococcus mutans and Lactobacillus acidophilus . Enamel blocks were evaluated by two independent examiners at baseline (phase I), after the first cariogenic challenge (eight days) (phase II), and after the second cariogenic challenge (a further eight days) (phase III) by two independent examiners using the LF, LFpen, and FC. Blocks were submitted to surface microhardness (SMH) and cross-sectional microhardness analyses. The intraclass correlation coefficient for intra- and interexaminer reproducibility ranged from 0.49 (FC) to 0.94 (LF/LFpen). SMH values decreased and fluorescence values increased significantly among the three phases. Higher values for sensitivity, specificity, and area under the receiver operating characteristic curve were observed for FC (phase II) and LFpen (phase III). A significant correlation was found between fluorescence values and SMH in all phases and integrated loss of surface hardness (ΔKHN) in phase III. In conclusion, fluorescence-based methods were effective in monitoring noncavitated caries-like lesions on smooth surfaces, with moderate correlation with SMH, allowing differentiation between sound and demineralized enamel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a case of laparoscopic surgical management of an iatrogenic lymphorrhea using indocyanine green (ICG). A case of a patient who developed recurrent symptomatic lymphorrhea after laparoscopic radical hysterectomy and bilateral pelvic lymphadenectomy for an early stage cervical cancer is presented. Intraoperative bipedal interdigital subcutaneous injection of ICG exactly localized the disrupted lymphatic duct on fluorescence imaging performed with a near-infrared laparoscopic fluorescent optic device, thus allowing a successful surgical repair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE (99)TC combined with blue-dye mapping is considered the best sentinel lymph node (SLN) mapping technique in cervical cancer. Indocyanine green (ICG) with near infrared fluorescence imaging has been introduced as a new methodology for SLN mapping. The aim of this study was to compare these two techniques in the laparoscopic treatment of cervical cancer. METHODS Medical records of patients undergoing laparoscopic SLN mapping for cervical cancer with either (99)Tc and patent blue dye (Group 1) or ICG (Group 2) from April 2008 until August 2012 were reviewed. Sensitivity, specificity, and overall and bilateral detection rates were calculated and compared. RESULTS Fifty-eight patients were included in the study-36 patients in Group 1 and 22 patients in Group 2. Median tumor diameter was 25 and 29 mm, and mean SLN count was 2.1 and 3.7, for Groups 1 and 2, respectively. Mean non-SLN (NSLN) count was 39 for both groups. SLNs were ninefold more likely to be affected by metastatic disease compared with NSLNs (p < 0.005). Sensitivity and specificity were both 100 %. Overall detection rates were 83 and 95.5 % (p = nonsignificant), and bilateral detection rates were 61 and 95.5 % (p < 0.005), for Groups 1 and 2, respectively. In 75 % of cases, SLNs were located along the external or internal iliac nodal basins. CONCLUSIONS ICG SLN mapping in cervical cancer provides high overall and bilateral detection rates that compare favorably with the current standard of care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Herein is presented a technique for minimally invasive sentinel node mapping. The patient had apparently early stage endometrial cancer. Sentinel node mapping was performed using a hysteroscopic injection of indocyanine green followed by laparoscopic sentinel node detection via near-infrared fluorescence. This technique ensures delineation of lymphatic drainage from the tumor area, thus achieving accurate detection of sentinel nodes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE The purpose of this study was to describe autofluorescence lifetime characteristics in Stargardt disease (STGD) using fluorescence lifetime imaging ophthalmoscopy (FLIO) and to investigate potential prognostic markers for disease activity and progression. METHODS Fluorescence lifetime data of 16 patients with STGD (mean age, 40 years; range, 22-56 years) and 15 age-matched controls were acquired using a fluorescence lifetime imaging ophthalmoscope based on a Heidelberg Engineering Spectralis system. Autofluorescence was excited with a 473-nm laser, and decay times were measured in a short (498-560 nm) and long (560-720 nm) spectral channel. Clinical features, autofluorescence lifetimes and intensity, and corresponding optical coherence tomography images were analyzed. One-year follow-up examination was performed in eight STGD patients. Acquired data were correlated with in vitro measured decay times of all-trans retinal and N-retinylidene-N-retinylethanolamine. RESULTS Patients with STGD displayed characteristic autofluorescence lifetimes within yellow flecks (446 ps) compared with 297 ps in unaffected areas. In 15% of the STGD eyes, some flecks showed very short fluorescence lifetimes (242 ps). Atrophic areas were characterized by long lifetimes (474 ps), with some remaining areas of normal to short lifetimes (322 ps) toward the macular center. CONCLUSIONS Patients with recent disease onset showed flecks with very short autofluorescence lifetimes, which is possible evidence of accumulation of retinoids deriving from the visual cycle. During the study period, many of these flecks changed to longer lifetimes, possibly due to accumulation of lipofuscin. Therefore, FLIO might serve as a useful tool for monitoring of disease progression. (ClinicalTrials.gov number, NCT01981148.).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sentinel lymph node (SLN) detection techniques have the potential to change the standard of surgical care for patients with prostate cancer. We performed a lymphatic mapping study and determined the value of fluorescence SLN detection with indocyanine green (ICG) for the detection of lymph node metastases in intermediate- and high-risk patients undergoing radical prostatectomy and extended pelvic lymph node dissection. A total of 42 patients received systematic or specific ICG injections into the prostate base, the midportion, the apex, the left lobe, or the right lobe. We found (1) that external and internal iliac regions encompass the majority of SLNs, (2) that common iliac regions contain up to 22% of all SLNs, (3) that a prostatic lobe can drain into the contralateral group of pelvic lymph nodes, and (4) that the fossa of Marcille also receives significant drainage. Among the 12 patients who received systematic ICG injections, 5 (42%) had a total of 29 lymph node metastases. Of these, 16 nodes were ICG positive, yielding 55% sensitivity. The complex drainage pattern of the prostate and the low sensitivity of ICG for the detection of lymph node metastases reported in our study highlight the difficulties related to the implementation of SNL techniques in prostate cancer. PATIENT SUMMARY There is controversy about how extensive lymph node dissection (LND) should be during prostatectomy. We investigated the lymphatic drainage of the prostate and whether sentinel node fluorescence techniques would be useful to detect node metastases. We found that the drainage pattern is complex and that the sentinel node technique is not able to replace extended pelvic LND.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Follicular lymphoma is the most common lymphoid malignancy in humans. The bcl-2 transgenic mice, which mimic the human follicular lymphoma, initially exhibit a polyclonal hyperplasia due to the overriding of apoptosis by deregulated bcl-2. After a latency period of 15 month 20% of the animals developed clonal lymphomas. Approximately, 50% of these high grade lymphomas presented chromosomal translocations involving c-myc, suggesting that deregulation of this gene is important in the complementation with bcl-2. E$\mu$-myc x bcl-2 double transgenic mice were generated to assess the ability of this two genes to complement in an in vivo system. The double transgenic mice presented a shortened latency (3-4 weeks) and higher incidence of tumor development. Quantification of the extent of programmed cell death indicated that bcl-2 can abrogate the high rate of apoptotic cell death that results from myc deregulation. Bcl-2-Ig, E$\mu$-myc, and bcl-2/E$\mu$-myc lymphomas were examined using PCR-SSCP to detect the presence of p53 mutations in exons 5-9. A high incidence of p53 mutations in E$\mu$-myc lymphomas suggested that inactivating lesions of p53 may represent an important step in the genetic complementation of c-myc in lymphomagenesis. Surprisingly, p53 mutations were quite uncommon in bcl-2 lymphomas suggesting that inactivating mutations of p53 and overexpression of bcl-2 may not cooperate in lymphoma progression. To assess this question, we generated mice that contained a deregulated bcl-2 gene and were nullizygous for p53 (p53KO). No reduction in the tumor latency was observed in the p53KO/bcl-2-Ig hybrid mice when compared with p53 KO mice. Using splenic mononuclear cells isolated from p53KO mice and bcl-2 transgenic mice we demonstrated that bcl-2 suppresses p53 mediated apoptosis in response to DNA damage initiated by $\gamma$-radiation even though p53 protein is induced normally in the bcl-2 overexpressing cells. Western analysis of the expression of p53 target proteins after $\gamma$-radiation showed a correlation between the p53-dependent induction of bax protein after radiation and the ability of p53 to mediate apoptosis. ^