961 resultados para Bilayers oriented under magnetic field
Resumo:
Magnetic microsphere comprises a magnetically responsive metal or metal oxide core surrounded by a polymer shell with active groups. Nowadays, methods of directly coating polymer, monomer polymerazation, impregnation, extrusion and biological synthesis are generally used to prepare magnetic particles. This kind of superparamagnetic microspheres can be attached to chemical, biochemical and biological substances by their active groups, then applying a magnetic field to separate from the media. Preparation and utilization of magnetic microspheres in immunoassay, nucleic acid hybrization assay, gene sequencing, cell isolation, enzyme immoblization, receptor isolation and other Gelds are reviewed with 44 references in this paper. Also, the further development is outlooked.
Resumo:
Paleointensity changes of geomagnetic field help us to understand the evolutionprocess of earth completely and provide further constraints for earth interior process and geodynamo model. Marine sediments are good carriers for relative paleointensity of geomagnetic field. But in most cases, deep sea sediments that conform with magnetic "uniformity" usually have low sedimentation rate about l-2cm/ka and lie under the Carbonate Compensate Depth with little carbonate content. Therefore, the number of relative paleointensity records with detailed oxygen stratigraphy is still rare. This thesis focus on four cores from east of Ryukyu Trench which have foraminiferal content of 5-30% and sedimentation rate of lOcm/ka and wish to get centennial -millennial changes of relative paleointensity.The sediments from east of Ryukyu Trench conform with magnetic "uniformity" and remanences of four cores all show single component with stable direction and faithfully record the magnetic field. The NRM301T1T/ARM and NRMsomT/ x are still affected by grain size and concentration changes although the sediments are "uniform" , indicating the uniformity might not enough for relative paleointensity. After renomalized by grain size parameter MDF, the intensities remove the effect of grain size changes to different degrees and show coherency in 1-1 Oka scale with results from ODP983/984. The characteristics of paleointensity of geomagnetic field arefrom 32-24kaBP, paleointensity of geomagnetic field is low;24-12kaBP, paleointensity of geomagnetic field is high and shows two peaks boundary with 19kaBP.3) 12-5.3ka, paleointensity is low. Then increase from 5,3kaBP until a small trough at 2.7kaBP, then increase till now.
Resumo:
Grande, Manuel, et al., 'Plasma acceleration above Martian magnetic anomalies', Science (2006) 311(5763) pp.980-983 RAE2008
Resumo:
Pint?r, B.; Erd?lyi, R.; Goossens, M., Global oscillations in a magnetic solar model. II. Oblique propagation, Astronomy and Astrophysics, Volume 466, Issue 1, April IV 2007, pp.377-388 Pint?r, B.; Erd?lyi, R.; Goossens, M., (2007) 'Global oscillations in a magnetic solar model II. Oblique propagation', Astronomy and Astrophysics 466(1) pp.377-388 RAE2008
Resumo:
In this thesis, the evanescent field sensing techniques of tapered optical nanofibres and microspherical resonators are investigated. This includes evanescent field spectroscopy of a silica nanofibre in a rubidium vapour; thermo-optical tuning of Er:Yb co-doped phosphate glass microspheres; optomechanical properties of microspherical pendulums; and the fabrication and characterisation of borosilicate microbubble resonators. Doppler-broadened and sub-Doppler absorption spectroscopic techniques are performed around the D2 transition (780.24 nm) of rubidium using the evanescent field produced at the waist of a tapered nanofibre with input probe powers as low as 55 nW. Doppler-broadened Zeeman shifts and a preliminary dichroic atomic vapour laser lock (DAVLL) line shape are also observed via the nanofibre waist with an applied magnetic field of 60 G. This device has the potential for laser frequency stabilisation while also studying the effects of atom-surface interactions. A non-invasive thermo-optical tuning technique of Er:Yb co-doped microspheres to specific arbitrary wavelengths is demonstrated particularly to 1294 nm and the 5S1/2F=3 to 5P3/2Fʹ=4 laser cooling transition of 85Rb. Reversible tuning ranges of up to 474 GHz and on resonance cavity timescales on the order of 100 s are reported. This procedure has prospective applications for sensing a variety of atomic or molecular species in a cavity quantum electrodynamics (QED) experiments. The mechanical characteristics of a silica microsphere pendulum with a relatively low spring constant of 10-4 Nm-1 are explored. A novel method of frequency sweeping the motion of the pendulum to determine its natural resonance frequencies while overriding its sensitivity to environmental noise is proposed. An estimated force of 0.25 N is required to actuate the pendulum by a displacement of (1-2) μm. It is suggested that this is of sufficient magnitude to be experienced between two evanescently coupled microspheres (photonic molecule) and enable spatial trapping of the micropendulum. Finally, single-input borosilicate microbubble resonators with diameters <100 μm are fabricated using a CO2 laser. Optical whispering gallery mode spectra are observed via evanescent coupling with a tapered fibre. A red-shift of (4-22) GHz of the resonance modes is detected when the hollow cavity was filled with nano-filtered water. A polarisation conversion effect, with an efficiency of 10%, is observed when the diameter of the coupling tapered fibre waist is varied. This effect is also achieved by simply varying the polarisation of the input light in the tapered fibre where the efficiency is optimised to 92%. Thus, the microbubble device acts as a reversible band-pass to band-stop optical filter for cavity-QED, integrated solid-state and semiconductor circuit applications.
Resumo:
Of late, the magnetic properties of micro/nano-structures have attracted intense research interest both fundamentally and technologically particularly to address the question that how the manipulation in the different layers of nanostructures, geometry of a patterned structure can affect the overall magnetic properties, while generating novel applications such as in magnetic sensors, storage devices, integrated inductive components and spintronic devices. Depending on the applications, materials with high, medium or low magnetic anisotropy and their possible manipulation are required. The most dramatic manifestation in this respect is the chance to manipulate the magnetic anisotropy over the intrinsic preferential direction of the magnetization, which can open up more functionality particularly for device applications. Types of magnetic anisotropies of different nanostructured materials and their manipulation techniques are investigated in this work. Detail experimental methods for the quantitative determination of magnetic anisotropy in nanomodulated Ni45Fe55 thin film are studied. Magnetic field induced in-plane rotations within the nanomodulated Ni45Fe55 continuous films revealed various rotational symmetries of magnetic anisotropy due to dipolar interactions showing a crossover from lower to higher fold of symmetry as a function of modulation geometry. In a second approach, the control of exchange anisotropy at ferromagnetic (FM) – aniferomagnetic (AFM) interface in multifferoic nanocomposite materials, where two different phase/types of materials were simultaneously synthesized, was investigated. The third part of this work was to study the electroplated thin films of metal alloy nanocomposite for enhanced exchange anisotropy. In this work a unique observation of an anti-clock wise as well as a clock wise hysteresis loop formation in the Ni,Fe solid solution with very low coercivity and large positive exchange anisotropy/exchange bias have been investigated. Hence, controllable positive and negative exchange anisotropy has been observed for the first time which has high potential applications such as in MRAM devices.
Resumo:
The rotating-frame nuclear magnetic relaxation rate of spins diffusing on a disordered lattice has been calculated by Monte Carlo methods. The disorder includes not only variation in the distances between neighbouring spin sites but also variation in the hopping rate associated with each site. The presence of the disorder, particularly the hopping rate disorder, causes changes in the time-dependent spin correlation functions which translate into asymmetry in the characteristic peak in the temperature dependence of the dipolar relaxation rate. The results may be used to deduce the average hopping rate from the relaxation but the effect is not sufficiently marked to enable the distribution of the hopping rates to be evaluated. The distribution, which is a measure of the degree of disorder, is the more interesting feature and it has been possible to show from the calculation that measurements of the relaxation rate as a function of the strength of the radiofrequency spin-locking magnetic field can lead to an evaluation of its width. Some experimental data on an amorphous metal - hydrogen alloy are reported which demonstrate the feasibility of this novel approach to rotating-frame relaxation in disordered materials.
Resumo:
A simulation of the motion of molten aluminium inside an electrolytic cell is presented. Since the driving term of the aluminium motion is the Lorentz (j × B) body force acting within the fluid,this problem involves the solution of the magneto-hydro-dynamic equations. Different solver modules for the magnetic field computation and for the fluid motion simulation are coupled together. The interactions of all these are presented and discussed.
Resumo:
This work is concerned with the accurate computation of flow in a rapidly deforming liquid metal droplet, suspended in an AC magnetic field. Intense flow motion due to the induced electromagnetic force distorts dynamically the droplet envelope, which is initially spherical. The relative positional change between the liquid metal surface and the surrounding coil means that fluid flow and magnetic field computations need to be closely coupled. A spectral technique is used to solve this problem, which is assumed axisymmetric. The computed results are compared against a physical experiment and "ideal sphere" analytic solutions. A comparison between the "magnetic pressure" approximation and the full electromagnetic force solutions, shows fundamental differences; the full electromagnetic force solution is necessary for accurate results in most practical applications of this technique. The physical reason for the fundamental discrepancy is the difference in the electromagnetic force representation: only the gradient part of the full force is accounted for in the "magnetic pressure" approximation. Figs 9, Refs 13.
Resumo:
Electromagnetic levitation of electrically conductive droplets by alternating magnetic fields is a technique used to measure the physical properties of liquid metallic alloys such as surface tension or viscosity. Experiments can be conducted under terrestrial conditions or in microgravity, to reduce electromagnetic stirring and shaping of the droplet. Under such conditions, the time-dependent behaviour of a point of the free surface is recorded. Then the signal is analysed considering the droplet as a harmonic damped oscillator. We use a spectral code, for fluid flow and free surface descriptions, to check the validity of this assumption for two cases. First when the motion inside the droplet is generated by its initial distortion only and second, when the droplet is located in a uniform magnetic field originating far from the droplet. It is found that some deviations exist which can lead to an overestimate of the value of viscosity.
Resumo:
A method of droplet generation based on applying a modulated AC high frequency magnetic field in the localized region of capillary breakup is considered as ans alternative to traditional methods for high temperature liquid melt droplet serial production by pressure variation. The method is based on a pseudo-spectral approximation with a coordinate transformation adaptin to the developing free surface. The electromagnetic field is recomputed continuously with the domain shape change. Practical application cases for liquid silicon droplets of 0.5 - 2 mm diameter are considered in detail.
Resumo:
The waves in commercial cells for electrolytic aluminium production originate at the interface between the liquid aluminium and electrolyte, but their effect can spread into the surrounding busbar network as electric current perturbation, and the total magnetic field acquires a time dependent component. The presented model for the wave development accounts for the nonuniform electric current distribution at the cathode and the whole network of the surrounding busbars. The magnetic field is computed for the continuous current in the fluid zones, all busbars and the ferromagnetic construction elements. When the electric current and the associated magnetic field are computed according to the actual electrical circuit and updated for all times, the instability growth rate is significantly affected. The presented numerical model for the wave and electromagnetic interaction demonstrates how different physical coupling factors are affecting the wave development in the electrolysis cells. These small amplitude self-sustained interface oscillations are damped in the presence of intense turbulent viscosity created by the horizontal circulation velocity field. Additionally, the horizontal circulation vortices create a pressure gradient contributing to the deformation of the interface. Instructive examples for the 500 kA demonstration cell are presented.
Resumo:
The effects of a constant uniform magnetic field on thermoelectric currents during dendritic solidification were investigated using a 2-dimensional enthalpy based numerical model. Using an approximation of the dendrite growing in free space it was found that the resulting Lorentz force generates a circulating flow influencing the solidification pattern. As the magnetic field strength increases it was found that secondary growth on the clockwise side of the primary arm of the dendrite was encouraged, while the anticlockwise side is suppressed due to a reduction in local free energy. The preferred direction of growth rotated in the clockwise sense under an anti-clockwise flow for both the binary alloy and pure material. The tip velociy is significantly increased compared to growth in stagnant flow. This is due to a small recirculation that follows the tip of the dendrite; bringing in colder liquid and lower concentrations of solute. The recirculation being not normally incident on the tip is most likely the cause for the rotation. Grain growth consisting of multiple seeds with the same anisotropy growing in the same plane, gives a competition to release latent heat resulting in stunted growth. The initial growth for each dendrite is very similar to the single seed cases indicating that dendrites must become before the thermoelectric interactions are significant.
Resumo:
The effects of a constant uniform magnetic field on dendritic solidification were investigated using a 2-dimensional enthalpy based numerical model. The interaction between thermoelectic currents and the magnetic field generates a Lorentz force that creates a flow. This flow causes a change in the morphology of the dendrite; secondary growth is promoted on one side of the dendrite arm and the tip velocity of the primary arm is increased.
Resumo:
Thermoelectric currents in the presence of a magnetic field generate Lorentz forces which can drive fluid flow. In the case of dendritic growth a naturally occurring thermoelectric current exists and in the presence of a high magnetic field micro convections are generated. Experimental evidence has attributed changes in microstructure to this effect. A numerical model has been developed to study the flow field around an unconstricted equiaxed dendrite growing under these conditions. The growth is modeled in 2D and 3D by an enthalpy based method and a complex flow structure has been predicted. Using a pseudo-3D approximation for economy, realistic 2D simulations are obtained where a fully coupled transient scheme reveals significant changes to the dendrite morphology reflecting experimental evidence. There is a rotation of the preferred direction of growth and increased secondary branching.