903 resultados para BASELINE CONCENTRATIONS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of combustion driven acoustic oscillations in carbon monoxide and nitrogen oxides emission rates of a combustor operated with liquefied petroleum gas (LPG) were investigated. Because the fuel does not contain nitrogen, tests were also conducted with ammonia injected in the fuel, in order to study the formation of fuel NOx. The main conclusions were: (a) the pulsating combustion process is more efficient than the non-pulsating one and (b) the pulsating combustion process generates higher rates of NOx, with and without ammonia injection, as shown by CO and NO concentrations as function of the O-2 concentration. An increase in the LPG flow rate, keeping constant the air to fuel ratio, increased the acoustic pressure amplitude and the frequency of oscillation. The injection of ammonia had no influence on either pressure amplitude or frequency. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To compare the cardiorespiratory changes induced by equipotent concentrations of halothane (HAL), isoflurane (ISO) and sevollurane (SEVO) before and after hemorrhage.Study design. Prospective, randomized clinical trial.Animals. Twenty-four healthy adult dogs weighing 15.4 +/- 3.4 kg (mean +/- SD).Methods. Animals were randomly allocated to one of three groups (n = 8 per group). In each group, anesthesia was maintained with 1.5 minimum alveolar concentration of HAL (1.3%), ISO (1.9%,) and SEVO (3.5%) in oxygen. Controlled ventilation was performed to maintain eucapnia. Cardiorespiratory variables were evaluated at baseline (between 60 and 90 minutes after induction), immediately after and 30 minutes after the withdrawal of 32 mL kg(-1) of blood (400% of the estimated blood volume) over a 30-minute period.Results. During baseline conditions, ISO and SEVO resulted in higher cardiac index (CI) than HAL. Heart rates were higher with SEVO at baseline. while mean arterial pressure (MAP) and mean pulmonary arterial pressure did not differ between groups. Although heart rate values were higher for ISO and SEVO after hemorrhage, only ISO resulted in a higher CI when compared with HAL. In ISO-anesthetized dogs, MAP was higher immediately after hemorrhage, and this was related to better maintenance of CI and to an increase in systemic vascular resistance index from baseline.Conclusions. Although the hemodynamic responses of ISO and SEVO are similar in normovolaemic dogs, ISO results in better maintenance of circulatory function during the early period following a massive blood loss. Clinical relevance Inhaled anesthetics should be used judiciously in animals presented with blood loss. However, if an inhalational agent is to be used under these circumstances, ISO may provide better hemodynamic stability than SEVO or HAL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare the efficiency of an Aeroneb Pro vibrating plate and an Atomisor MegaHertz ultrasonic nebulizer for providing ceftazidime distal lung deposition.Design: In vitro experiments. One gram of cetazidime was nebulized in respiratory circuits and mass median aerodynamic diameter of particles generated by ultrasonic and vibrating plate nebulizers was compared using a laser velocimeter. In vivo experiments. Lung tissue concentrations and extrapulmonary depositions were measured in ten anesthetized ventilated piglets with healthy lungs that received 1 g of ceftazidime by nebulization with either an ultrasonic (n = 5), or a vibrating plate (n = 5) nebulizer.Setting: A two-bed Experimental Intensive Care Unit of a University School of Medicine.Intervention: Following sacrifice, 5 subpleural specimens were sampled in dependent and nondependent lung regions for measuring ceftazidime lung tissue concentrations by high-performance liquid chromatography.Measurements and results: Mass median aerodynamic diameters generated by both nebulizers were similar with more than 95% of the particles between 0.5 and 5 mu m. Lung tissue concentrations were 553 +/- 123 [95% confidence interval: 514-638] mu g g(-1) using ultrasonic nebulizer, and 452 +/- 172 [95% confidence interval: 376-528] mu g g(-1) using vibrating plate nebulizers (NS). Extrapulmonary depositions were, respectively, of 38 +/- 5% (ultrasonic) and 34 +/- 4% (vibrating plate) (NS).Conclusions: Vibrating plate nebulizer is comparable to ultrasonic nebulizers for ceftazidime nebulization. It may represent a new attractive technology for inhaled antibiotic therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The gastrointestinal tract is one of the first organs affected by hypoperfusion during hemorrhagic shock. The hemodynamics and oxygen transport variables during hemorrhagic shock and resuscitation can be affected by the anesthetics used. In a model of pressure-guided hemorrhagic shock in dogs, we studied the effects of three halogenated anesthetics - halothane, sevoflurane, and isoflurane - at equipotent concentrations on gastric oxygenation. Thirty dogs were anesthetized with 1.0 minimum alveolar anesthetic concentration (MAC) of either halothane, sevoflurane, or isoflurane. A gastric tonometer was placed in the stomach to determine mucosal gastric CO2 (PgCO(2)) and for the calculation of gastric-arterial PCO2 gradient (PCO2 gap). The dogs were splenectomized and hemorrhaged to hold mean arterial pressure at 40-50 mm Hg over 45 min and then resuscitated with the shed blood volume. Hemodynamics, systemic oxygenation, and PCO2 gap were measured at baseline, after 45 min of hemorrhage, and at 15 and 60 min after blood resuscitation. Hemorrhage induced reductions of mean arterial pressure and cardiac index, while systemic oxygen extraction increased (p < .05), without significant differences among groups (p > .05). Halothane group showed significant lower PCO2 gap values than the other groups (p < .05). After 60 min of shed blood replacement, all groups restored hemodynamics, systemic oxygenation, and PCO2 gap to the prehemorrhage levels (p > .05), without significant differences among groups (p > .05). We conclude that halothane is superior to preserve the gastric mucosal perfusion in comparison to isoflurane and sevoflurane, in dogs submitted to pressure-guided hemorrhagic shock at equipotent doses of halogenated anesthetics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We aim to investigate the effectiveness of a 10-week lifestyle intervention focusing on physical activity and high fiber intake for reducing indicators for metabolic syndrome in overweight-obese individuals. A prospective study of 50 overweight (OW) adults (22 in the general educational group - G1; 28 in the high fiber nutrition group - G2) was performed. Both groups were offered dietary counseling and supervised exercise. Clinical, anthropometric, dietary and plasma biochemical tests were performed at baseline - time 0 (T0) and after 10 weeks - time 1 (T1). Both groups improved their dietary quality, but only G2 presented higher intake of fruit and vegetables (servings/day), higher plasma beta-carotene levels and a 24% reduction of MetS incidence. Additionally G2 showed greater reductions in body fat (4%), and waist circumference (7%), obesity class III (2%) and obesity class II (14%) rate. Lifestyle intervention, including a high dietary fiber intake, improved healthy eating index and decreased body fat composition and plasma lipid concentrations leading to MetS incidence reduction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the accuracy of hand-held refractometer in determining plasma protein concentrations in South American snake-necked turtle (Hydromedusa tectifera) as compared with the standard biuret method. The results indicated that plasma protein values may be accurately determined in snake- necked turtle with a hand-held refractometer.