966 resultados para Automated neonatal seizure detection
Resumo:
Dissertation presented to obtain the Ph.D degree in Chemistry.
Resumo:
In the present study PCR was applied to detect leptospires in human urine. Several approaches for sample processing were evaluated to optimize the detection of leptospires in urine mixed with this bacterium. Furthermore, some changes in the composition of the reaction mix were studied. No amplification was observed in acidic urine, therefore neutralization of the sample immediately after collection is strongly recommended. PBS gave better results than Tris or NaOH as neutralizing reagents. Freezing and thawing of samples before processing yielded negative results. Elimination of epithelial cells, leukocytes and crystals by centrifugation at 3,000 rpm at room temperature increased sensitivity. In addition, both the washing step after collecting leptospires by centrifugation and the inclusion of 0.1% bovine serum albumin in the reaction mix minimized the interference of other inhibitory compounds. These modifications were useful to improve the detection of Leptospira in urine by PCR.
Resumo:
A ligase chain reaction DNA amplification method for direct detection of Mycobacterium tuberculosis (Abbott LCx MTB) in respiratory specimens was evaluated. Results from LCx MTB Assay were compared with those from acid fast bacilli smear, culture, and final clinical diagnosis for each patient. A total of 297 respiratory specimens (sputum and bronchial lavage) from 193 patients were tested. The sensitivity, specificity, positive predictive value and negative predictive value of LCx vs culture were 92.7%, 93%, 67.8% and 98.7%, respectively. When compared to the clinical final diagnosis, the sensitivity, specificity, PPV and NPV for LCx were 88.9%, 96.8%, 86.5% and 97.4%, respectively. The sensitivity of LCx MTB assay was 75% for smear-negative, culture positive samples. The results indicate that LCx MTB assay is a rapid, simple and valuable technique as a complementary tool for the diagnosis of tuberculosis.
Resumo:
A digoxigenin-labeled probe was produced from the Pasteur virus strain for the detection of the rabies virus N gene. The probe hybridization was performed from amplified N gene obtained by reverse transcription polymerase chain reaction and the results by RT-PCR and hybridization showed 100% agreement. The hybridization, when carried out in products amplified by RT-PCR, increases the sensitivity of this technique even more and confers specificity to the diagnosis. The technique described in this work will be useful in rabies diagnosis laboratories, once the cost is compatible with traditional rabies diagnostic techniques.
Resumo:
This dissertation presents an approach aimed at three-dimensional perception’s obstacle detection on all-terrain robots. Given the huge amount of acquired information, the adversities such environments present to an autonomous system and the swiftness, thus required, from each of its navigation decisions, it becomes imperative that the 3-D perceptional system to be able to map obstacles and passageways in the most swift and detailed manner. In this document, a hybrid approach is presented bringing the best of several methods together, combining the lightness of lesser meticulous analyses with the detail brought by more thorough ones. Realizing the former, a terrain’s slope mapping system upon a low resolute volumetric representation of the surrounding occupancy. For the latter’s detailed evaluation, two novel metrics were conceived to discriminate the little depth discrepancies found in between range scanner’s beam distance measurements. The hybrid solution resulting from the conjunction of these two representations provides a reliable answer to traversability mapping and a robust discrimination of penetrable vegetation from that constituting real obstructions. Two distinct robotic platforms offered the possibility to test the hybrid approach on very different applications: a boat, under an European project, the ECHORD Riverwatch, and a terrestrial four-wheeled robot for a national project, the Introsys Robot.
Resumo:
Mycobaterium leprae infection was investigated in armadillos from the State of Espírito Santo, Brazil. The ML Flow test was performed on 37 nine-banded armadillos and positive results were found in 11 (29.7%). The ML Flow test may be used to identify possible sources of Mycobaterium leprae among wild armadillos.
Resumo:
Breast cancer is the most common type of cancer worldwide. The effectiveness of its treatment depends on early stage detection, as well as on the accuracy of its diagnosis. Recently, diagnosis techniques have been submitted to relevant breakthroughs with the upcoming of Magnetic Resonance Imaging, Ultrasound Sonograms and Positron Emission Tomography (PET) scans, among others. The work presented here is focused on studying the application of a PET system to a Positron Emission Mammography (PEM) system. A PET/PEM system works under the principle that a scintillating crystal will detect a gamma-ray pulse, originated at the cancerous cells, converting it into a correspondent visible light pulse. The latter must then be converted into an electrical current pulse by means of a Photo- -Sensitive Device (PSD). After the PSD there must be a Transimpedance Amplifier (TIA) in order to convert the current pulse into a suitable output voltage, in a time period lower than 40 ns. In this Thesis, the PSD considered is a Silicon Photo-Multiplier (SiPM). The usage of this recently developed type of PSD is impracticable with the conventional TIA topologies, as it will be proven. Therefore, the usage of the Regulated Common-Gate (RCG) topology will be studied in the design of the amplifier. There will be also presented two RCG variations, comprising a noise response improvement and differential operation of the circuit. The mentioned topology will also be tested in a Radio-Frequency front-end, showing the versatility of the RCG. A study comprising a low-voltage self-biasing feedback TIA will also be shown. The proposed circuits will be simulated with standard CMOS technology (UMC 130 nm), using a 1.2 V power supply. A power consumption of 0.34 mW with a signal-to-noise ratio of 43 dB was achieved.
Resumo:
Nowadays, existing 3D scanning cameras and microscopes in the market use digital or discrete sensors, such as CCDs or CMOS for object detection applications. However, these combined systems are not fast enough for some application scenarios since they require large data processing resources and can be cumbersome. Thereby, there is a clear interest in exploring the possibilities and performances of analogue sensors such as arrays of position sensitive detectors with the final goal of integrating them in 3D scanning cameras or microscopes for object detection purposes. The work performed in this thesis deals with the implementation of prototype systems in order to explore the application of object detection using amorphous silicon position sensors of 32 and 128 lines which were produced in the clean room at CENIMAT-CEMOP. During the first phase of this work, the fabrication and the study of the static and dynamic specifications of the sensors as well as their conditioning in relation to the existing scientific and technological knowledge became a starting point. Subsequently, relevant data acquisition and suitable signal processing electronics were assembled. Various prototypes were developed for the 32 and 128 array PSD sensors. Appropriate optical solutions were integrated to work together with the constructed prototypes, allowing the required experiments to be carried out and allowing the achievement of the results presented in this thesis. All control, data acquisition and 3D rendering platform software was implemented for the existing systems. All these components were combined together to form several integrated systems for the 32 and 128 line PSD 3D sensors. The performance of the 32 PSD array sensor and system was evaluated for machine vision applications such as for example 3D object rendering as well as for microscopy applications such as for example micro object movement detection. Trials were also performed involving the 128 array PSD sensor systems. Sensor channel non-linearities of approximately 4 to 7% were obtained. Overall results obtained show the possibility of using a linear array of 32/128 1D line sensors based on the amorphous silicon technology to render 3D profiles of objects. The system and setup presented allows 3D rendering at high speeds and at high frame rates. The minimum detail or gap that can be detected by the sensor system is approximately 350 μm when using this current setup. It is also possible to render an object in 3D within a scanning angle range of 15º to 85º and identify its real height as a function of the scanning angle and the image displacement distance on the sensor. Simple and not so simple objects, such as a rubber and a plastic fork, can be rendered in 3D properly and accurately also at high resolution, using this sensor and system platform. The nip structure sensor system can detect primary and even derived colors of objects by a proper adjustment of the integration time of the system and by combining white, red, green and blue (RGB) light sources. A mean colorimetric error of 25.7 was obtained. It is also possible to detect the movement of micrometer objects using the 32 PSD sensor system. This kind of setup offers the possibility to detect if a micro object is moving, what are its dimensions and what is its position in two dimensions, even at high speeds. Results show a non-linearity of about 3% and a spatial resolution of < 2µm.
Resumo:
The objective of the present study was to estimate the frequency of infection by Cryptosporidium spp and other intestinal parasites in dehydrated children with gastroenteritis who were admitted to a pediatric hospital. Stool examinations from 218 children were performed. Cryptosporidium spp was identified in eighteen out of 193 stool samples (9.3%) subjected to safranin-methylene blue staining. Giardia lamblia was detected in ten out of 213 (4.7%) samples examined via the direct or Ritchie methods. Other parasites identified were Ascaris lumbricoides (4.2%), Blastocystis hominis (1.4%), Entamoeba coli (0.9%), Entamoeba histolytica/Entamoeba dispar (0.5%), Endolimax nana (0.5%), Trichuris trichiura (0.5%) and Enterobius vermicularis (0.5%).
Resumo:
Vibrio cholerae has been sporadically isolated from rivers in Tucumán, Argentina, since the outbreak in 1991. The aim of this study was to determine the environmental reservoir of the bacterium in these rivers, assessing the presence of Vibrio cholerae non-O1 and O1 (the latter both in its viable culturable and non culturable state) and its relationship to environmental physicochemical variables. 18 water samplings were collected in the Salí River (in Canal Norte and Banda) and the Lules River between 2003 and 2005. Physical-chemical measurements (pH, water temperature, electrical conductivity and dissolved oxygen) were examined. Vibrio cholerae was investigated with conventional culture methods and with Direct Immunofluorescence (DFA-VNC) in order to detect viable non culturable organisms. All isolated microorganisms corresponded to Vibrio cholerae non-O1 and non-O139 (Lules 26%, Canal Norte 33% and Banda 41%). The majority was found during spring and summer and correlated with temperature and pH. Non culturable Vibrio cholerae O1 was detected year round in 38 of the 54 water samples analyzed. Application of the Pearson correlation coefficient revealed that there was no relationship between positive immunofluorescence results and environmental physicochemical parameters. Genes coding for somatic antigen O1 were confirmed in all DFA-VNC-positive samples, whereas the virulence-associated ctxA and tcpA genes were confirmed in 24 samples.
Resumo:
Detection of anti-toxoplasma IgM antibodies has frequently been used as a serological marker for diagnosing recently acquired toxoplasmosis. However, the persistence of these antibodies in some patients has complicated the interpretation of serological results when toxoplasmosis is suspected. The purpose of the present study was to evaluate the avidity of IgG antibodies against excreted/secreted antigens of Toxoplasma gondii by means of immunoblot, to establish a profile for acute recent infection in a single serum sample and confirm the presence of residual IgM antibodies obtained in automated assays. When we evaluated the avidity of IgG antibodies against excreted/secreted antigens of Toxoplasma gondii by means of immunoblot, we observed phase-specific reactivity, i.e. cases of acute recent toxoplasmosis presented low avidity and cases of non-acute recent toxoplasmosis presented high avidity towards the 30kDa protein fraction, which probably corresponds to the SAG-1 surface antigen. Our results suggest that the avidity of IgG antibodies against excreted/secreted antigens of Toxoplasma gondii is an important immunological marker for distinguishing between recent infections and for determining the presence of residual IgM antibodies obtained from automated assays.
Resumo:
O objetivo de nosso estudo foi realizar tipagem molecular de 25 amostras clínicas de Candida spp, isoladas de crianças com candidemia, internadas na unidade de terapia intensiva neonatal de um Hospital Universitário entre 1998 a 2006. Dados demográficos e clínicos foram obtidos de prontuários para conhecimento dos aspectos clínicos e epidemiológicos. Identificação das leveduras foi feita por método convencional e a susceptibilidade antifúngica por método de microdiluição. O perfil genético foi determinado pela técnica de RAPD-PCR. Candida albicans (11; 44%) e Candida parapsilosis (10; 40%) foram as mais isoladas. Dezessete (68%) dos recém-nascidos tinham peso inferior a 1.500g. Prematuridade (92%), uso de cateter venoso central (100%), foram as condições de risco mais associados. Dezenove (76%) pacientes foram a óbito. Apenas uma cepa de Candida parapsilosis, mostrou ser sensível dose dependente ao fluconazol. Na análise molecular, foram observados 11 padrões genéticos distintos. Somente em dois casos foi observada relação epidemiológica, sugerindo mesma fonte de infecção.
Resumo:
Part of this thesis will be published in the following: Gomes, B.C., Santos, B. 2015. Methods for studying microRNAs expression and their targets in formalin-fixed, paraffin-embedded (FFPE) breast cancer tissues. In Methods in Molecular Biology: Cancer Drug Resistance (Rueff, J. & Rodrigues, A.S. eds), Springer Protocols.
Resumo:
Diagnosis of human herpesvirus-7 active infection in transplant patients has proved difficult, because this virus is ubiquitous and can cause persistent infections in the host. The significance of viral DNA detected in leukocytes by PCR is unclear and cross-reaction in serological tests may occur. This study aimed to evaluate nested-PCR to detect human herpesvirus-7 active infection in liver transplant recipients compared to healthy individuals. human herpesvirus-7 nested-PCR was performed on leukocytes and sera of 53 healthy volunteers and sera of 29 liver transplant recipients. In healthy volunteers, human herpesvirus-7 was detected in 28.3% of leukocytes and 0% of serum. human herpesvirus-7 was detected in sera of 48.2% of the liver transplant recipients. Nested-PCR on DNA extracted from leukocytes detected latent infection and the study suggests that nested-PCR performed on serum could be useful to detect human herpesvirus-7 active infection in liver transplant recipients.
Resumo:
O presente estudo tem como objetivo avaliar os testes sorológicos convencionais usados na triagem neonatal para doença de Chagas, discutindo métodos estatísticos disponíveis. Estudou-se uma amostra aleatória dentre 23.308 recém-nascidos triados para doença de Chagas congênita por meio de três testes: imunoensaioenzimático, imunofluorescência indireta e hemoaglutinação indireta. Os dados obtidos foram analisados por diferentes metodologias estatísticas: a análise de classe latente, o teste Kappa e a análise de sensibilidade relativa. Utilizando a análise de classe latente, a maior sensibilidade foi do imunoensaioenzimático (48,6%), seguido pela imunofluorescência indireta (39,8%) e pela hemoaglutinação indireta (23,2%). O valor Kappa foi 0,496. A razão entre as sensibilidades dos testes imunoensaioenzimático e imunofluorescência indireta foi de 92% [0,74;1,13]. A análise de classe latente não se mostrou adequada para determinação de sensibilidade e especificidade, mas forneceu dados importantes sobre a equivalência dos testes, corroborados pela análise de sensibilidade relativa. Os resultados mostraram que o teste imunoensaioenzimático em sangue-seco pode ser utilizado com a mesma segurança do teste imunofluorescência indireta.