863 resultados para Auricular protection
Resumo:
There is a clear need for financial protection in the construction industry, both to guarantee satisfactory completion of construction projects and to guard against non-payment. However, the cost of financial protection is often felt to be disproportionately high, with unnecessary overlap between different measures. The Reading Construction Forum has commissioned and steered research which is published in this report in an effort to bring the problem out into the open and to clarify the various options open to the various parties and stakeholders in the construction process. "Financial Protection in the UK Building Industry" is the first definitive report on the subject, offering an accurate and simple guide that all levels within the construction industry can understand. This accessible new guide considers the problem of financial protection and clearly lays out the alternative solutions.It looks by turn at the client, the main contractor, and the sub-contractor, discussing which financial protection options are available to each of them, and considers the pros and cons of each option. The cost of each type of financial protection is weighed against the amount of protection provided and the risks involved. The book concludes with guidance for consultants, emphasising relevant points to consider when advising clients and contractors about which type of financial protection to choose. "Financial Protection in the UK Building Industry" was researched by a literature search, collection of statistical data, and financial data, as well as discussions with clients, contractors, sub-contractors and consultants. This investigation has shown that the direct costs of implementing financial protection measures are marginal, and that wider adoption of payment protection would create a more equitable situation between contracting parties.This guide will enable anyone in the construction industry to consider all the options, and determine what is the best solution for them. "Reading Construction Forum Financial Protection for the UK Building Industry" was complied by the University of Reading, funded by the Reading Construction Forum. The Forum has recently commissioned and steered a number of high-profile reports covering important aspects of the construction industry. Members of the Forum include major companies which are concerned with achieving high quality in the design, construction and use of commercial, retail and industrial buildings. All are committed to change and innovation in the British and European construction industries.
Resumo:
Financial Protection in the UK Building Industry provides comprehensive treatment of a complex aspect of construction management which is increasingly important in modern construction contracts. The term 'Financial Protection' refers to refers to the various mechanisms by which funds are made available to ensure the due performance of a partys contractual obligations. This book is based on material written for a research project funded by the Reading Construction Forum. Financial Protection in the UK Building Industry looks at the legal and economic background to the problem of providing financial protection to clients to guard against poor performance and or the insolvency of contractors, consultants and sub-contractors. The inclusion of practical guidance notes and summaries makes this a valuable guide for the construction professional as well as for the researcher. * provides in-depth analysis of financial protection measures * explores the ways in which financial protection can increase efficiency in the industry * financial protection in construction is beset with problems - this book points toward practical solutions
Resumo:
Architects and engineers depend on copyright law to protect their original works. Copyright protection is automatic once a tangible medium of expression in any form of an innovative material, conforming the Copyright Designs and Patents Act 1988, is created. In terms of architectural works, they are protected as literary works (design drawings and plans) and as artistic works (the building or model of the building). The case law on the concept of “originality” however discloses that it may be difficult for certain artistic works of architecture to achieve copyright protection. Although copyright law provides automatic protection to all original architectural plans, the limitation is that it only protects the expression of ideas but not the ideas themselves. The purpose of this research is to explore how effective the UK’s copyright law regime is for protecting the rights and interests of architects in their works. In addition, the United States system of copyright law will be analysed to determine whether it provides more effective protection for architects and engineers with regard to architectural works. The key objective in carrying out this comparison is to compare and contrast the extent to which the two systems protect the rights and interests of architects against copyright infringement. This comparative analysis concludes by considering the possibility of copyright law reform in the UK.
Resumo:
We previously found that dried live bacteria of a vaccine strain can be temporarily sensitive to bile acids and suggested that Bile Adsorbing Resins (BAR) can be used in oral vaccine tablets to protect dried bacteria from intestinal bile. Here, we report a quantitative analysis of the ability of BAR to exclude the dye bromophenol blue from penetrating into matrix tablets and also sections of hard capsule shells. Based on this quantitative analysis, we made a fully optimised formulation, comprising 25% w/w of cholestyramine in Vcaps™ HPMC capsules. This gave effectively 100% protection of viability from 4% bile, with 4200-fold more live bacteria recovered from this formulation compared to unprotected dry bacteria. From the image analysis, we found that the filler material or compaction force used had no measurable effect on dye exclusion but did affect the rate of tablet hydration. Increasing the mass fraction of BAR gave more exclusion of dye up to 25% w/w, after which a plateau was reached and no further dye exclusion was seen. More effective dye exclusion was seen with smaller particle sizes (i.e. cholestyramine) and when the BAR was thoroughly dried and disaggregated. Similar results were found when imaging dye penetration into capsule sections or tablets. The predictions of the dye penetration study were tested using capsules filled with dried attenuated Salmonella vaccine plus different BAR types, and the expected protection from bile was found, validating the imaging study. Surprisingly, depending on the capsule shell material, some protection was given by the capsule alone without adding BAR, with Vcaps™ HPMC capsules providing up to 174-fold protection against 1% bile; faster releasing Vcaps Plus™ HPMC capsules and Coni Snap™ gelatin capsules gave less protection.
Resumo:
We previously demonstrated that a dry, room temperature stable formulation of a live bacterial vaccine was highly susceptible to bile, and suggested that this will lead to significant loss of viability of any live bacterial formulation released into the intestine using an enteric coating or capsule. We found that bile and acid tolerance is very rapidly recovered after rehydration with buffer or water, raising the possibility that rehydration in the absence of bile prior to release into the intestine might solve the problem of bile toxicity to dried cells. We describe here a novel formulation that combines extensively studied bile acid adsorbent resins with the dried bacteria, to temporarily adsorb bile acids and allow rehydration and recovery of bile resistance of bacteria in the intestine before release. Tablets containing the bile acid adsorbent cholestyramine release 250-fold more live bacteria when dissolved in a bile solution, compared to control tablets without cholestyramine or with a control resin that does not bind bile acids. We propose that a simple enteric coated oral dosage form containing bile acid adsorbent resins will allow improved live bacterial delivery to the intestine via the oral route, a major step towards room temperature stable, easily administered and distributed vaccine pills and other bacterial therapeutics