975 resultados para Aortic depressor nerve
Resumo:
This study investigated the excitability and accommodative properties of low-threshold human motor axons to test whether these motor axons have greater expression of the persistent Na(+) conductance, I(NaP). Computer-controlled threshold tracking was used to study 22 single motor units and the data were compared with compound motor potentials of various amplitudes recorded in the same experimental session. Detailed comparisons were made between the single units and compound potentials that were 40% or 5% of maximal amplitude, the former because this is the compound potential size used in most threshold tracking studies of axonal excitability, the latter because this is the compound potential most likely to be composed entirely of motor axons with low thresholds to electrical recruitment. Measurements were made of the strength-duration relationship, threshold electrotonus, current-voltage relationship, recovery cycle and latent addition. The findings did not support a difference in I(NaP). Instead they pointed to greater activity of the hyperpolarization-activated inwardly rectifying current (I(h)) as the basis for low threshold to electrical recruitment in human motor axons. Computer modelling confirmed this finding, with a doubling of the hyperpolarization-activated conductance proving the best single parameter adjustment to fit the experimental data. We suggest that the hyperpolarization-activated cyclic nucleotide-gated (HCN) channel(s) expressed on human motor axons may be active at rest and contribute to resting membrane potential.
Resumo:
Various factors, including maturity, have been shown to influence peripheral nerve excitability measures, but little is known about differences in these properties between axons with different stimulation thresholds. Multiple nerve excitability tests were performed on the caudal motor axons of immature and mature female rats, recording from tail muscles at three target compound muscle action potential (CMAP) levels: 10%, 40% ("standard" level), and 60% of the maximum CMAP amplitude. Compared to lower target levels, axons at high target levels have the following characteristics: lower strength-duration time constant, less threshold reduction during depolarizing currents and greater threshold increase to hyperpolarizing currents, most notably to long hyperpolarizing currents in mature rats. Threshold-dependent effects on peripheral nerve excitability properties depend on the maturation stage, especially inward rectification (Ih), which becomes inversely related to threshold level. Performing nerve excitability tests at different target levels is useful in understanding the variation in membrane properties between different axons within a nerve. Because of the threshold effects on nerve excitability and the possibility of increased variability between axons and altered electric recruitment order in disease conditions, excitability parameters measured only at the "standard" target level should be interpreted with caution, especially the responses to hyperpolarizing currents.
Resumo:
The aim of this study was to investigate the histomorphological changes of the infraorbital nerve of rats treated with ampicillin.
Resumo:
The aim of this work is to assess the repeatability of spectral-domain-OCT (SD-OCT) retinal nerve fiber layer thickness (RNFL) thickness measurements in a non-glaucoma group and patients with glaucoma and to compare these results to conventional time-domain-OCT (TD-OCT).
Resumo:
In this study we sought to evaluate the reproducibility of sensory nerve conduction studies (NCS) using ultrasound-guided needle positioning (USNP).
Resumo:
To determine whether advanced age was independently associated with prohibitive surgical risks or impaired long-term prognosis after ruptured aortic aneurysm repair.
Resumo:
Perineurioma is an uncommon, mostly benign, spindle-cell tumor of peripheral nerve sheath origin with a predilection for the soft tissues. Although increasing awareness points to the sites of involvement by perineurioma possibly being as ubiquitous as those frequented by schwannian tumors, only one intracerebral example has been described to date. We report on a surgically resected perineurioma of the falx cerebri in an 86-year-old woman. Preoperative imaging showed an enhancing extraaxial mass of 6 cm × 5.7 cm × 3.7 cm. Histologically, the tumor consisted of a proliferation of spindle cells interwoven by a lattice of basal lamina. Alongside a prevailing soft tissue perineurioma pattern, sclerosing and reticular areas were seen as well. Tumor cells coexpressed EMA and GLUT-1, and a minority immunoreacted for smooth muscle actin. Pericellular basal lamina was decorated with collagen type IV. No staining for S100 protein was detected. Mitotic activity was virtually absent, and the MIB1 labeling index averaged 2%. Ultrastructural examination revealed abundant pinocytotic vesicles within and conspicuous tight junctions between slender cytoplasmic processes which, in turn, were encased by discontinuous basal lamina. FISH analysis confirmed loss of at least part of one chromosome 22q. This observation calls attention to perineurioma as a novel item in the repertoire of low-grade meningial spindle cell neoplasms, in the differential diagnostic context of which it is apt to being misconstrued as either meningioma, solitary fibrous tumor, or neurofibroma. Confusion with the latter bears the risk of overgrading innocuous features of perineurioma as criteria for malignancy.
Resumo:
Transcatheter aortic valve implantation (TAVI) is an alternative to surgery for high-risk patients with severe aortic valve stenosis. Periprocedural stroke is reported at an incidence up to 10%. Magnetic resonance imaging studies have identified new onset of clinically silent ischaemic cerebral lesions more frequently (68-84%). So far, few data are available about cerebral embolism during TAVI. The aim of this study was to determine the frequency of high-intensity transient signals (HITS) and to explore differences in the HITS pattern between transfemoral and transapical access and between self-expanding (SE) and balloon-expandable (BE) deployment technique.