Resumo:
The purpose of this study was to assess the spatial resolution of a computed tomography (CT) scanner with an automatic approach developed for routine quality controls when varying CT parameters. The methods available to assess the modulation transfer functions (MTF) with the automatic approach were Droege's and the bead point source (BPS) methods. These MTFs were compared with presampled ones obtained using Boone's method. The results show that Droege's method is not accurate in the low-frequency range, whereas the BPS method is highly sensitive to image noise. While both methods are well adapted to routine stability controls, it was shown that they are not able to provide absolute measurements. On the other hand, Boone's method, which is robust with respect to aliasing, more resilient to noise and provides absolute measurements, satisfies the commissioning requirements perfectly. Thus, Boone's method combined with a modified Catphan 600 phantom could be a good solution to assess CT spatial resolution in the different CT planes.
Resumo:
Our goal was to evaluate the diagnostic utility of C-reactive protein (CRP) alone or combined with clinical probability assessment in patients with suspected pulmonary embolism (PE), and to compare its performance to a D-dimer assay. We conducted a prospective study in which we performed a common immuno-turbidimetric CRP test and a rapid enzyme-linked immunosorbent assay (ELISA) D-dimer test in 259 consecutive outpatients with suspected PE at the emergency department of a teaching hospital. We assessed clinical probability of PE by a validated prediction rule overridden by clinical judgment. Patients with D-dimer levels > or = 500 microg/l underwent a work-up consisting of lower-limb venous ultrasound, spiral computerized tomography, ventilation-perfusion scan, or pulmonary angiography. Patients were followed up for three months. Seventy-seven (30%) of the patients had PE. The CRP alone had a sensitivity of 84% (95% confidence interval [CI).: 74 to 92%) and a negative predictive value (NPV) of 87% (95% CI: 78 to 93%) at a cutpoint of 5 mg/l. Overall, 61 (24%) patients with a low clinical probability of PE had a CRP < 5 mg/l. Due to the low prevalence of PE (9%) in this subgroup, the NPV increased to 97% (95% CI: 89 to 100%). The D-dimer (cutpoint 500 micro g/l) showed a sensitivity of 100% (95% CI: 95 to 100%) and a NPV of 100% (95% CI: 94 to 100%) irrespective of clinical probability and accurately rule out PE in 56 (22%) patients. Standard CRP tests alone or combined with clinical probability assessment cannot safely exclude PE.
Resumo:
We report the observation of a fifty years old man, admitted in the emergency room for bilateral lumbar pain and hyperkaliemic metabolic acidosis, and postrenal kidney failure induced by bilateral hydronephrosis. Radiographic exploration and histologic studies of biopsy confirmed an idiopathic retroperitoneal fibrosis that clinically and biologicaly responded to three seances of hemodialysis, and insertion in each uretere of one double J stent, and long term corticotherapy. The retroperitoneal fibrosis is a little common inflammatory disease, characterized by the development of a fibrous mass around the retroperitoneal structures. His diagnostic means evolved. On the other hand, his treatment was the object of no checked controlled and randomized trial. This article proposes an updating of the knowledge on this subject.
Resumo:
Open surgery is still the main treatment of complex abdominal aortic aneurysm. Nevertheless, this approach is associated with major complications and high mortality rate. Therefore the fenestrated endograft has been used to treat the juxtarenal aneurysms. Unfortunately, no randomised controlled study is available to assess the efficacy of such devices. Moreover, the costs are still prohibitive to generalise this approach. Alternative treatments such as chimney or sandwich technique are being evaluated in order to avoid theses disadvantages. The aim of this paper is to present the endovascular approach to treat juxtarenal aneurysm and to emphasize that this option should be used only by highly specialized vascular centres.
Resumo:
Objectives: Osteitis pubis is a noninfectious painfulinflammatory disorder of the symphysis pubis. Etiologicfactors are numerous, the most common are: osseousextension of adductor enthesis due to sport overuse,irritation after urological and abdominal procedures, andsystemic inflammatory disorders in particular spondylarthropathies.Many cases are idiopathic. The symptomsconsist of regional chronic mechanical and sometimenocturnal pain. Diagnosis is usually confirmed by eitherbone scintigraphy or by MRI. There are no standardtreatments but conservative approaches including rest andNSAIDS are generally recommended. In 2001, a goodclinical and radiological response of three refractory caseswith 3-6 monthly perfusions of pamidronate was reported(1). Ibandronate is a much more powerful and long-lastingbisphosphonate than pamidronate, and has not yet beenreported in literature to our knowledge in this indication.Materials/Methods: We present two cases of idiopathicorigin: one woman (63 years old) and one man (36 yearsold).The symptoms were present >3 months in the firstpatient and 1 year in the second. The diagnosis wasconfirmed by MRI which showed bone edema on bothsizes of symphysis and in the second case bony erosionsadjacent to the joint were seen. Both cases failed to respondto conservative measures. Both patients received one singledirect iv Injection of 3 mg of Ibandronate.Results: The injections resulted in a rapid (within a fewdays) resolution of pain that lasted more than 6 months inboth patients. No side effects were observed. In the firstcase, an isotope bone scan performed 4 months after theinjection showed no residual uptake. The second patienthad a repeated MRI after 6 months. It demonstrated anattenuation of bone edema compared to the first MRI.Conclusions: IV Ibandronate may constitute a safe andeffective treatment option for patients with refractoryosteitis pubis.Reference: 1: Maksymowych WP, Aaron SL, Russell AS, JRheumatol 28:2754, 2001.Disclosure of Interest: None declared.
Resumo:
Little is known about the long-term survivors of acute arsenic intoxication. We present here a clinical case report of a man with chronic hepatitis B virus (HBV) infection who developed hepatocellular carcinoma four years after acute arsenic poisoning. HBsAg was detected in serum in 1990 when he voluntarily donated blood. In 1991, the patient suffered from severe psychological depression that led him to attempt suicide by massive ingestion of an arsenic-containing rodenticide. He survived with polyneuropathy and paralysis of the lower limbs, and has been wheelchair-bound since then. During participation in a follow-up study conducted among HBV carriers, abdominal ultrasound detected a two-centimeter liver mass consistent with hepatocellular carcinoma. The tumor was confirmed by computed tomography (CT) and magnetic resonance image (MRI). Because of his significant comorbidity, the patient received palliative treatment with transarterial lipiodol chemoembolization (TACE) on three occasions (1996, 1997 and 1999). At his most recent visit in May 2005, the patient was asymptomatic, liver enzymes were normal and the tumor was in remission on ultrasound.
Resumo:
The MIT Scan T2 device has been implemented in Iowa as a new method for determining PCC pavement thickness compliance. The T2 device utilizes a magnetic pulse induction technology to measure the distance from a sensor to a metal target. The objective of this project was to conduct an interlaboratory study (ASTM C802) to determine the precision of the test.Fifteen MIT Scan T2 gauges and fifteen operators performed testing on three reference platforms and nine pavement locations of varying thicknesses. The testing was conducted on October 29, 2014 at two sites near Ames, Iowa. Usable data was obtained from every operator at all locations.
Resumo:
Dose kernel convolution (DK) methods have been proposed to speed up absorbed dose calculations in molecular radionuclide therapy. Our aim was to evaluate the impact of tissue density heterogeneities (TDH) on dosimetry when using a DK method and to propose a simple density-correction method. METHODS: This study has been conducted on 3 clinical cases: case 1, non-Hodgkin lymphoma treated with (131)I-tositumomab; case 2, a neuroendocrine tumor treatment simulated with (177)Lu-peptides; and case 3, hepatocellular carcinoma treated with (90)Y-microspheres. Absorbed dose calculations were performed using a direct Monte Carlo approach accounting for TDH (3D-RD), and a DK approach (VoxelDose, or VD). For each individual voxel, the VD absorbed dose, D(VD), calculated assuming uniform density, was corrected for density, giving D(VDd). The average 3D-RD absorbed dose values, D(3DRD), were compared with D(VD) and D(VDd), using the relative difference Δ(VD/3DRD). At the voxel level, density-binned Δ(VD/3DRD) and Δ(VDd/3DRD) were plotted against ρ and fitted with a linear regression. RESULTS: The D(VD) calculations showed a good agreement with D(3DRD). Δ(VD/3DRD) was less than 3.5%, except for the tumor of case 1 (5.9%) and the renal cortex of case 2 (5.6%). At the voxel level, the Δ(VD/3DRD) range was 0%-14% for cases 1 and 2, and -3% to 7% for case 3. All 3 cases showed a linear relationship between voxel bin-averaged Δ(VD/3DRD) and density, ρ: case 1 (Δ = -0.56ρ + 0.62, R(2) = 0.93), case 2 (Δ = -0.91ρ + 0.96, R(2) = 0.99), and case 3 (Δ = -0.69ρ + 0.72, R(2) = 0.91). The density correction improved the agreement of the DK method with the Monte Carlo approach (Δ(VDd/3DRD) < 1.1%), but with a lesser extent for the tumor of case 1 (3.1%). At the voxel level, the Δ(VDd/3DRD) range decreased for the 3 clinical cases (case 1, -1% to 4%; case 2, -0.5% to 1.5%, and -1.5% to 2%). No more linear regression existed for cases 2 and 3, contrary to case 1 (Δ = 0.41ρ - 0.38, R(2) = 0.88) although the slope in case 1 was less pronounced. CONCLUSION: This study shows a small influence of TDH in the abdominal region for 3 representative clinical cases. A simple density-correction method was proposed and improved the comparison in the absorbed dose calculations when using our voxel S value implementation.
Resumo:
Cases of fatal outcome after surgical intervention are autopsied to determine the cause of death and to investigate whether medical error caused or contributed to the death. For medico-legal purposes, it is imperative that autopsy findings are documented clearly. Modern imaging techniques such as multi-detector computed tomography (MDCT) and postmortem CT angiography, which is used for vascular system imaging, are useful tools for determining cause of death. The aim of this study was to determine the utility of postmortem CT angiography for the medico-legal death investigation. This study investigated 10 medico-legal cases with a fatal outcome after surgical intervention using multi-phase postmortem whole body CT angiography. A native CT scan was performed as well as three angiographic phases (arterial, venous, and dynamic) using a Virtangio((R)) perfusion device and the oily contrast agent, Angiofil((R)). The results of conventional autopsy were compared to those from the radiological investigations. We also investigated whether the radiological findings affected the final interpretation of cause-of-death. Causes of death were hemorrhagic shock, intracerebral hemorrhage, septic shock, and a combination of hemorrhage and blood aspiration. The diagnoses were made by conventional autopsy as well as by postmortem CT angiography. Hemorrhage played an important role in eight of ten cases. The radiological exam revealed the exact source of bleeding in seven of the eight cases, whereas conventional autopsy localized the source of bleeding only generally in five of the seven cases. In one case, neither conventional autopsy nor CT angiography identified the source of hemorrhage. We conclude that postmortem CT angiography is extremely useful for investigating deaths following surgical interventions. This technique helps document autopsy findings and allows a second examination if it is needed; specifically, it detects and visualizes the sources of hemorrhages in detail, which is often of particular interest in such cases.
Resumo:
PURPOSE: To implement real-time myocardial strain-encoding (SENC) imaging in combination with tracking the tissue displacement in the through-plane direction. MATERIALS AND METHODS: SENC imaging was combined with the slice-following technique by implementing three-dimensional (3D) selective excitation. Certain adjustments were implemented to reduce scan time to one heartbeat. A total of 10 volunteers and five pigs were scanned on a 3T MRI scanner. Spatial modulation of magnetization (SPAMM)-tagged images were acquired on planes orthogonal to the SENC planes for comparison. Myocardial infarction (MI) was induced in two pigs and the resulting SENC images were compared to standard delayed-enhancement (DE) images. RESULTS: The strain values computed from SENC imaging with slice-following showed significant difference from those acquired without slice-following, especially during systole (P < 0.01). The strain curves computed from the SENC images with and without slice-following were similar to those computed from the orthogonal SPAMM images, with and without, respectively, tracking the tag line displacement in the strain direction. The resulting SENC images showed good agreement with the DE images in identifying MI in infarcted pigs. CONCLUSION: Correction of through-plane motion in real-time cardiac functional imaging is feasible using slice-following. The strain measurements are more accurate than conventional SENC measurements in humans and animals, as validated with conventional MRI tagging.