987 resultados para 3D Reconstruction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To combine weighted iterative reconstruction with self-navigated free-breathing coronary magnetic resonance angiography for retrospective reduction of respiratory motion artifacts. METHODS: One-dimensional self-navigation was improved for robust respiratory motion detection and the consistency of the acquired data was estimated on the detected motion. Based on the data consistency, the data fidelity term of iterative reconstruction was weighted to reduce the effects of respiratory motion. In vivo experiments were performed in 14 healthy volunteers and the resulting image quality of the proposed method was compared to a navigator-gated reference in terms of acquisition time, vessel length, and sharpness. RESULT: Although the sampling pattern of the proposed method contained 60% more samples with respect to the reference, the scan efficiency was improved from 39.5 ± 10.1% to 55.1 ± 9.1%. The improved self-navigation showed a high correlation to the standard navigator signal and the described weighting efficiently reduced respiratory motion artifacts. Overall, the average image quality of the proposed method was comparable to the navigator-gated reference. CONCLUSION: Self-navigated coronary magnetic resonance angiography was successfully combined with weighted iterative reconstruction to reduce the total acquisition time and efficiently suppress respiratory motion artifacts. The simplicity of the experimental setup and the promising image quality are encouraging toward future clinical evaluation. Magn Reson Med 73:1885-1895, 2015. © 2014 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Certain situations and pathological processes that arise with temporomandibular joint destruction can only be resolved with surgical reconstructive procedures in order to attempt a functional and anatomical rehabilitation of this joint. Many of these situations can be surgically treated with the patient's own autologous tissues. However, in some patients reconstruction is complex and the use of autologous tissues is unadvisable whereas reconstruction utilizing alloplastic materials may be an appropriate alternative. The following report describes 4 clinical cases in which autologous grafts or Christensen joint prosthesis are employed in temporomandibular joint reconstruction

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the performance of an optical camera based prospective motion correction (PMC) system in improving the quality of 3D echo-planar imaging functional MRI data. An optical camera and external marker were used to dynamically track the head movement of subjects during fMRI scanning. PMC was performed by using the motion information to dynamically update the sequence's RF excitation and gradient waveforms such that the field-of-view was realigned to match the subject's head movement. Task-free fMRI experiments on five healthy volunteers followed a 2×2×3 factorial design with the following factors: PMC on or off; 3.0mm or 1.5mm isotropic resolution; and no, slow, or fast head movements. Visual and motor fMRI experiments were additionally performed on one of the volunteers at 1.5mm resolution comparing PMC on vs PMC off for no and slow head movements. Metrics were developed to quantify the amount of motion as it occurred relative to k-space data acquisition. The motion quantification metric collapsed the very rich camera tracking data into one scalar value for each image volume that was strongly predictive of motion-induced artifacts. The PMC system did not introduce extraneous artifacts for the no motion conditions and improved the time series temporal signal-to-noise by 30% to 40% for all combinations of low/high resolution and slow/fast head movement relative to the standard acquisition with no prospective correction. The numbers of activated voxels (p<0.001, uncorrected) in both task-based experiments were comparable for the no motion cases and increased by 78% and 330%, respectively, for PMC on versus PMC off in the slow motion cases. The PMC system is a robust solution to decrease the motion sensitivity of multi-shot 3D EPI sequences and thereby overcome one of the main roadblocks to their widespread use in fMRI studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sedimentary and micropaleontological study of the Quillagua Formation provides a detailed paleohydrological reconstruction of the lacustrine system which occupied the present-day hyperarid Quillagua-Llamara fore-arc Basin (Northern Chile) from lattermost Miocene to Early Pliocene times.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Proper delineation of ocular anatomy in 3-dimensional (3D) imaging is a big challenge, particularly when developing treatment plans for ocular diseases. Magnetic resonance imaging (MRI) is presently used in clinical practice for diagnosis confirmation and treatment planning for treatment of retinoblastoma in infants, where it serves as a source of information, complementary to the fundus or ultrasonographic imaging. Here we present a framework to fully automatically segment the eye anatomy for MRI based on 3D active shape models (ASM), and we validate the results and present a proof of concept to automatically segment pathological eyes. METHODS AND MATERIALS: Manual and automatic segmentation were performed in 24 images of healthy children's eyes (3.29 ± 2.15 years of age). Imaging was performed using a 3-T MRI scanner. The ASM consists of the lens, the vitreous humor, the sclera, and the cornea. The model was fitted by first automatically detecting the position of the eye center, the lens, and the optic nerve, and then aligning the model and fitting it to the patient. We validated our segmentation method by using a leave-one-out cross-validation. The segmentation results were evaluated by measuring the overlap, using the Dice similarity coefficient (DSC) and the mean distance error. RESULTS: We obtained a DSC of 94.90 ± 2.12% for the sclera and the cornea, 94.72 ± 1.89% for the vitreous humor, and 85.16 ± 4.91% for the lens. The mean distance error was 0.26 ± 0.09 mm. The entire process took 14 seconds on average per eye. CONCLUSION: We provide a reliable and accurate tool that enables clinicians to automatically segment the sclera, the cornea, the vitreous humor, and the lens, using MRI. We additionally present a proof of concept for fully automatically segmenting eye pathology. This tool reduces the time needed for eye shape delineation and thus can help clinicians when planning eye treatment and confirming the extent of the tumor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS AND BACKGROUND: The standard treatment of anal canal cancer (ACC) is combined chemotherapy and radiation therapy (RT), which is complex because of the shape of the target volumes and the need to minimize the irradiation of normal pelvic structures. In this study we compared the dosimetric results of helical tomotherapy (HT) plans with traditional 3D conformal RT (3DRT) plans for the treatment of ACC. METHODS AND STUDY DESIGN: Twelve patients (median age 57 years, range 38-83; F/M 8/4) treated with HT and concurrent chemotherapy for locally advanced ACC were selected. All had histologically confirmed squamous-cell carcinoma. A clinical target volume including the tumor and pelvic and inguinal lymph nodes was treated with HT to a total dose of 36 Gy in 1.8-Gy daily fractions. Then a sequential boost of 23.4 Gy in 1.8-Gy daily fractions (total dose 59.4 Gy) was delivered to the tumor and involved nodes. For all 12 patients, 3DRT plans were generated for comparison. Treatment plans were evaluated by means of standard dose-volume histograms. Dose coverage of the planning target volumes (PTVs), homogeneity index (HI), and mean doses to organs at risk (OARs) were compared. RESULTS: The coverage of PTV was comparable between the two treatment plans. HI was better in the HT vs. 3DRT plans (1.25 and 3.57, respectively; p<0.0001). HT plans resulted in better sparing of OARs (p<0.0001). CONCLUSIONS: HT showed superior target dose conformality and significant sparing of pelvic structures compared with 3DRT. Further investigation should determine if these dosimetric improvements will improve clinical outcomes regarding locoregional control, survival, and treatment-related acute and late morbidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[cat] Aquest article metodològic ofereix estimacions del PIB per càpita regional de les regions portugueses, entre 1890 i 1980. Aquestes estimacions s’han obtingut seguint la metodologia proposada per (Geary and Stark, 2002) per a la industria, i considerant estimacions de producció directa per la resta de sectors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

n this work we analyze the behavior of complex information in Fresnel domain taking into account the limited capability to display complex transmittance values of current liquid crystal devices, when used as holographic displays. In order to do this analysis we compute the reconstruction of Fresnel holograms at several distances using the different parts of the complex distribution (real and imaginary parts, amplitude and phase) as well as using the full complex information adjusted with a method that combines two configurations of the devices in an adding architecture. The RMS error between the amplitude of these reconstructions and the original amplitude is used to evaluate the quality of the information displayed. The results of the error analysis show different behavior for the reconstructions using the different parts of the complex distribution and using the combined method of two devices. Better reconstructions are obtained when using two devices whose configurations densely cover the complex plane when they are added. Simulated and experimental results are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[cat] Aquest article metodològic ofereix estimacions del PIB per càpita regional de les regions portugueses, entre 1890 i 1980. Aquestes estimacions s’han obtingut seguint la metodologia proposada per (Geary and Stark, 2002) per a la industria, i considerant estimacions de producció directa per la resta de sectors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

3D-suunnittelujärjestelmät ovat tärkeitä työkaluja tuotetiedon luomista ja muokkaamista varten, joten niiden tehokas toiminta yhdessä tuotetiedonhallintajärjestelmien kanssa on erittäin tärkeää. 3D-suunnittelujärjestelmien kehityksen seurauksena 3D-malleihin voidaan sisällyttää entistä enemmän tuotetietoa, jolloin tehokas tiedon tallentaminen ja sen hallinta kasvattaa merkitystään. 3D-malleihin sisältyvää tietoa, kuten esimerkiksi kappaleen painoa tai geometriaa, halutaan myös tarkastella ilman tiettyä 3D-järjestelmää. Tuotetiedon hallinta on ollut jo pitkään tärkeä osa tuotteen suunnitteluprosessia. Tuotetiedon hallintaan sisältyy tiedon luomista, keräämistä ja muokkaamista koko tuotteen eliniän ajan. Näitä tietoja voivat olla esimerkiksi piirustukset, 3D-mallit, mittauspöytäkirjat, kokouspöytäkirjat, mallistoluettelot, lujuuslaskelmat, huoltoraportit jne. Tuotetiedonhallintajärjestelmä pitää huolta kaikesta tästä tiedosta ja sen kautta tuotteisiin liittyvää tietoa voidaan myös muokata ja jakaa tehokkaasti. Tässä diplomityössä tutkittiin näiden kahden järjestelmän integraation toteutusta erilaisilla menetelmillä. Työn tarkoituksena oli valita Valtra Oy:n tarkoituksiin parhaiten sopiva menetelmä tuotetiedon siirtämiseksi järjestelmien välillä tehokkaasti. Työn tuloksena annetaan suositus käytettävistä menetelmistä ja työkaluista.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents an innovative methodology for forensic science image analysis for event reconstruction. The methodology is based on experiences from real cases. It provides real added value to technical guidelines such as standard operating procedures (SOPs) and enriches the community of practices at stake in this field. This bottom-up solution outlines the many facets of analysis and the complexity of the decision-making process. Additionally, the methodology provides a backbone for articulating more detailed and technical procedures and SOPs. It emerged from a grounded theory approach; data from individual and collective interviews with eight Swiss and nine European forensic image analysis experts were collected and interpreted in a continuous, circular and reflexive manner. Throughout the process of conducting interviews and panel discussions, similarities and discrepancies were discussed in detail to provide a comprehensive picture of practices and points of view and to ultimately formalise shared know-how. Our contribution sheds light on the complexity of the choices, actions and interactions along the path of data collection and analysis, enhancing both the researchers' and participants' reflexivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämä diplomityö on tehty Andritz Oy:lle Washers & Filters tuoteryhmään. Työ on osa 3D-suunnittelujärjestelmän käyttöönottoprojektia. Tavoitteena on arvioida uuden laitesuunnittelujärjestelmän vaikutuksia yrityksen tietojärjestelmiin ja toimintatapoihin sekä etsiä potentiaalisia tulevaisuuden kehityskohteita. Suunnittelutietoa hyödyntäviä sidosryhmien edustajia haastattelemalla selvitettiin järjestelmille ja ohjelmistoille asetettavia vaatimuksia. Ohjelmistoihin tutustumalla saatiin käsitys niiden nykytilasta ja kehityssuunnista. 3D-geometrian hyödyntämiseen perustuvilla järjestelmillä voidaan poistaa päällekäistä työtä sekä lyhentää läpimenoaikoja suunnittelussa ja valmistuksessa sijoittamalla työvaiheita rinnakkain. Suurimmat 3D-suunnittelun edut saavutetaan tuotekehitysvaiheessa, tuotemuutoksia tehtäessä sekä valmistusprosesseja suunniteltaessa. Ongelmallisimmat osa-alueet tietojärjestelmien kehittämisessä ovat ensi-sijaisesti tiedonsiirto ohjelmistojen välillä, työntekijöiden muutosvastarinta sekä laadukkaiden järjestelmien korkea hinta. Laajojen tietojärjestelmä-projektien läpivienti on hyvin haastavaa ja onnistuminen vaatii kaikkien sidosryhmien mukana olemista ja tarkkaa projektin koordinointia.