988 resultados para 291503 Biomaterials


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Adherence of bacteria to biomaterials is the first stage in the development of a device-related infection. The adherence of bacterial cells to biomaterials may be influenced by surface characteristics of the cell, its growth conditions and the biomaterial surface chemistry. Following growth in human urine, the cell surface,hydrophobicity and zeta potential of two ureteral stent biofilm isolates, Enterococcus faecalis and Escherichia coli, were significantly altered. In addition, the adherence of human urine-grown Enterococcus faecalis and Escherichia coli to polyurethane was significantly increased by up to 52.1% and 58.6%, respectively. Treatment of the polyurethane with human urine rendered the polymer surface more hydrophilic (mean advancing water contact angle reduced from 97.59 degrees to 26.37 degrees). However, organisms grown in human urine showed less adherence (up to 90.4%) to the treated polymer than those grown in Mueller-Hinton broth. The results presented in this study indicate that in vivo conditions should be simulated as far as possible when carrying out in vitro bacterial adherence assays, especially if assessing novel methods for reduction of adherence. (C) 1997 Elsevier Science B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In practice, polyvinyl chloride endotracheal tubes and polyurethane urinary catheters are located in areas where they are exposed to the conditioning fluids saliva and urine, respectively. Samples of both biomaterials were incubated in these conditioning fluids and, following treatment, dynamic contact angle measurement and surface roughness assessment by atomic force microscopy were used to analyse surface characteristics. Over a 24 h period of contact with the conditioning fluids, the surface of both materials became significantly more hydrophilic (p

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two different natural zeolites having different phase compositions were obtained from different regions of Turkey and modified by ion-exchange (0.5 M NH4NO3) and acid leaching using 1 M HCl. The natural and modified samples were treated at low temperature (LT), high temperature (HT) and steam (ST) conditions and characterised by XRF, XRD, BET, FTIR, DR-UV-Vis, NH3-TPD and TGA. Ion-exchange with NH4+ of natural zeolites results in the exchange of the Na+ and Ca2+ cations and the partial exchange of the Fe3+ and Mg2+ cations. However, steam and acidic treatments cause significant dealumination and decationisation, as well as loss of crystalline, sintering of phases and the formation of amorphous material. The presence of mordenite and quartz phases in the natural zeolites increases the stability towards acid treatment, whereas the structure of clinoptilolite-rich zeolites is mostly maintained after high temperature and steam treatments. The natural and modified zeolites treated at high temperature and in steam were found to be less stable compared with synthetic zeolites, resulting in a loss of crystallinity, a decrease in the surface area and pore volume, a decrease in the surface acidity as well as dealumination, and decationisation. (C) 2012 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effectiveness of the antimicrobial peptide maximin-4, the ultrashort peptide H-Orn-Orn-Trp-Trp-NH(2) , and the lipopeptide C(12) -Orn-Orn-Trp-Trp-NH(2) in preventing adherence of pathogens to a candidate biomaterial were tested utilizing both matrix- and immersion-loaded poly(2-hydroxyethyl methacrylate) (poly(HEMA)) hydrogels. Antiadherent properties correlated to both the concentration released and the relative antimicrobial concentrations of each compound against Staphylococcus epidermidis ATCC 35984, at each time point. Immersion-loaded samples containing C(12) -Orn-Orn-Trp-Trp-NH(2) exhibited the lowest adherence profile for all peptides studied over 1, 4, and 24 h. The results outlined in this article show that antimicrobial peptides have the potential to serve as an important weapon against biomaterial associated infections. © 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2012.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bioresorbable polymers have been widely investigated as materials exhibiting significant potential for successful application in the fields of tissue engineering and drug delivery. Further to the ability to control degradation, surface engineering of polymers has been highlighted as a key method central to their development. Previous work has demonstrated the ability of electron beam (e-beam) technology to control the degradation profiles and bioresorption of a number of commercially relevant bioresorbable polymers (poly-l-lactic acid (PLLA), Llactide/DL-lactide co-polymer (PLDL) and poly(lactic-co-glycolic acid (PLGA)). This work investigates the further potential of ebeam technology to impart added biofunctionality through the manipulation of polymer (PLLA) surface properties. PLLA samples were subjected to e-beam treatments in air, with varying beam energies and doses. Surface characterization was then performed using contact angle analysis, X-ray photoelectron spectroscopy (XPS), Raman spectroscopy, and atomic force microscopy. Results demonstrated a significant increase in surface wettability post e-beam treatment. In correlation with this, XPS data showed the introduction of oxygen-containing functional groups to the surface of PLLA. Raman spectroscopy indicated chain scission in the near surface region of PLLA (as predicted). However, e-beam effects on surface properties were not shown to be dependent on beam energy or dose. E-beam irradiation did not seem to affect the surface roughness of PLLA as a direct consequence of the treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Novel drug delivery systems (DDS) to improve the pharmacokinetic profile of hydrophobic drugs following oral administration are an area of keen interest in drug research. An ideal DDS should not adversely affect drug activity, be capable of delivering a therapeutic dose of drug, and allow homogenous drug loading and drug release. Mesoporous silica has been proposed for this application, with ibuprofen employed as the model drug. It was hypothesised that mesoporous silica MCM-41 is capable of delivering a pharmacologically therapeutic dose of ibuprofen. Ibuprofen-loaded MCM-41 can be prepared reproducibly at a drug to carrier ratio of 30% (wt/wt). The release profile was seen to be 90% within 2 h. Initial assessment of COX-1 inhibitory activity suggests the absence of adverse effects attributable to drug-carrier interaction. The results of this study provide further evidence in support of the proposed use of mesoporous silica in drug delivery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Silver coating of catheters has been shown to have inhibitory effects on bacterial growth and adhesion to catheter surfaces. In this study, plasma-modification was used to enhance the adhesion of an electroless silver coating on polyurethane. Both the antibacterial and antiadhesive properties of these coatings were investigated. Bacterial growth was inhibited in cultures exposed to silver-treated polyurethane compared to unmodified polyurethane. Higher growth inhibition was observed for polyurethane surfaces with lower silver coverage. Bacterial adhesion was completely inhibited on all silver-coated surfaces.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The physicochemical characteristics of the injectable polymeric gels for use in the treatment of periodontal disease were investigated. The hardness, compressibility, and mucoadhesive properties of the gel were determined using a TA-XT2 Texture analyzer. The effect of of polymer concentration on the various viscoelastic, textural, bioadhesive properties and drug release were also analyzed using multifactorial analysis of variance. It was found that increased polymer concentration significantly increased gel structure, reduced polymer chain mobility and subsequently decreased the swelling/erosion and diffusion properties of the gel networks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Unique microneedle arrays prepared from crosslinked polymers, which contain no drug themselves, are described. They rapidly take up skin interstitial fluid upon skin insertion to form continuous, unblockable, hydrogel conduits from attached patch-type drug reservoirs to the dermal microcirculation. Importantly, such microneedles, which can be fabricated in a wide range of patch sizes and microneedle geometries, can be easily sterilized, resist hole closure while in place, and are removed completely intact from the skin. Delivery of macromolecules is no longer limited to what can be loaded into the microneedles themselves and transdermal drug delivery is now controlled by the crosslink density of the hydrogel system rather than the stratum corneum, while electrically modulated delivery is also a unique feature. This technology has the potential to overcome the limitations of conventional microneedle designs and greatly increase the range of the type of drug that is deliverable transdermally, with ensuing benefits for industry, healthcare providers and, ultimately, patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The rate and type of biological colonization of stone is influenced by a wide array of environmental factors in addition to substrate characteristics. A series of experiments was designed to compare the rate and type of biological colonization of stone at varying locations over a 21-month time period. Exposure
trials were set up at nine different sites across Northern Ireland that covered a wide variety of environmental conditions. To determine aspect-related differences in colonization, blocks of Peakmoor sandstone and Portland limestone were placed on the north- and south-facing sides of purpose-designed exposure racks. Colorimetry and visual analysis were carried out on collected samples at increasing time intervals. Results showed significantly different rates of darkening and greening over time between north-facing and south-facing blocks, for both sandstone and limestone. This difference is likely to be representative of the fact that in Northern Ireland’s wet climate and northern-latitude position, the north face of a building will receive less direct sunlight. Therefore north-facing blocks, once wet, will remain damp for much longer than blocks on other façades. This slow-drying phenomenon is much more hospitable for biological colonization and continued growth than the hostile environment of rapid wetting and drying cycles experienced on the south face.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the past decades, numerous types of nanomedicines have been developed for the efficient and safe delivery of nucleic acid-based drugs for cancer therapy. Given that the destination sites for nucleic acid-based drugs are inside cancer cells, delivery systems need to be both targeted and shielded in order to overcome the extracellular and intracellular barriers. One of the major obstacles that has hindered the translation of nanotechnology-based gene-delivery systems into the clinic has been the complexity of the design and assembly processes, resulting in non-uniform nanocarriers with unpredictable surface properties and efficiencies. Consequently, no product has reached the clinic yet. In order to address this shortcoming, a multifunctional targeted biopolymer is genetically engineered in one step, eliminating the need for multiple chemical conjugations. Then, by systematic modulation of the ratios of the targeted recombinant vector to PEGylated peptides of different sizes, a library of targeted-shielded viral-mimetic nanoparticles (VMNs) with diverse surface properties are assembled. Through the use of physicochemical and biological assays, targeted-shielded VMNs with remarkably high transfection efficiencies (>95%) are screened. In addition, the batch-to-batch variability of the assembled targeted-shielded VMNs in terms of uniformity and efficiency is examined and, in both cases, the coefficient of variation is calculated to be below 20%, indicating a highly reproducible and uniform system. These results provide design parameters for engineering uniform, targeted-shielded VMNs with very high cell transfection rates that exhibit the important characteristics for in vivo translation. These design parameters and principles could be used to tailor-make and assemble targeted-shielded VMNs that could deliver any nucleic acid payload to any mammalian cell type.