897 resultados para vibration active control
Resumo:
A non-invasive in vivo technique was developed to evaluate changes in wrist joint stability properties induced by increased co-activation of the forearm muscles in a gripping task. Mechanical vibration at 45, 50 and 55 Hz was applied to the radial head in ten healthy volunteers. Vibrations of the styloid process of the radius and the distal end of the metacarpal bone of the index finger were measured with triaxial accelerometers. Joint stability properties were quantified by the transfer function gain between accelerations on either side of the wrist-joint. Gain was calculated with the muscles at rest and at five force levels ranging from 5% to 25% of maximum grip force (%MF). During contraction the gain was significantly greater than in control trial (0%MF) for all contractions levels at 45 and 50 Hz and a trend for 15%MF and higher at 55 Hz. Group means of contraction force and gain were significantly correlated at 45 (R-2 = 0.98) and 50 Hz (R-2 = 0.72), but not at 55 Hz (R-2 = 0.10). In conclusion, vibration transmission gain may provide a method to evaluate changes in joint stability properties. (c) 2005 Published by Elsevier Ltd.
Highly demanding resistive vibration exercise program is tolerated during 56 days of strict bed-rest
Resumo:
Several studies have tried to find countermeasures against musculoskeletal de-conditioning during bed-rest, but none of them yielded decisive results. We hypothesised that resistive vibration exercise (RVE) might be a suitable training modality. We have therefore carried out a bed-rest study to evaluate its feasibility and efficacy during 56 days of bed-rest. Twenty healthy male volunteers aged 24 to 43 years were recruited and, after medical check-ups, randomised to a non-exercising control (Ctrl) group or a group that performed RVE 11 times per week. Strict bed-rest was controlled by video surveillance. The diet was controlled. RVE was performed in supine position, with a static force component of about twice the body weight and a smaller dynamic force component. RVE comprised four different units (squats, heel raises, toe raises, kicks), each of which lasted 60 - 100 seconds. Pre and post exercise levels of lactate were measured once weekly. Body weight was measured daily on a bed scale. Pain questionnaires were obtained in regular intervals during and after the bed-rest. Vibration frequency was set to 19 Hz at the beginning and progressed to 25.9 Hz (SD 1.9) at the end of the study, suggesting that the dynamic force component increased by 90%. The maximum sustainable exercise time for squat exercise increased from 86 s (SD 21) on day 11 of the BR to 176 s (SD 73) on day 53 (p = 0.006). On the same days, post-exercise lactate levels increased from 6.9 mmol/l (SD2.3) to 9.2 mmol/l (SD 3.5, p = 0.01). On average, body weight was unchanged in both groups during bed-rest, but single individuals in both groups depicted significant weight changes ranging from -10% to + d10% (p < 0.001). Lower limb pain was more frequent during bed-rest in the RVE subjects than in Ctrl (p = 0.035). During early recovery, subjects of both groups suffered from muscle pain to a comparable extent, but foot pain was more common in Ctrl than in RVE (p = 0.013 for plantar pain, p = 0.074 for dorsal foot pain). Our results indicate that RVE is feasible twice daily during bed-rest in young healthy males, provided that one afternoon and one entire day per week are free. Exercise progression, mainly by progression of vibration frequency, yielded increases in maximum sustainable exercise time and blood lactate. In conclusion, RVE as performed in this study, appears to be safe.
Resumo:
A bacterium (MJ-PV) previously demonstrated to degrade the cyanobacterial toxin microcystin LR, was investigated for bioremediation applications in natural water microcosms and biologically active slow sand filters. Enhanced degradation of microcystin LR was observed with inoculated (1 x 10(6) cell/mL) treatments of river water dosed with microcystin LR (> 80% degradation within 2 days) compared to uninoculated controls. Inoculation of MJ-PV at lower concentrations (1 x 10(2)-1 x 10(5)cells/mL) also demonstrated enhanced microcystin LR degradation over control treatments. Polymerase chain reactions (PCR) specifically targeting amplification of 16S rDNA of MJ-PV and the gene responsible for initial degradation of microcystin LR (mlrA) were successfully applied to monitor the presence of the bacterium in experimental trials. No amplified products indicative of an endemic MJ-PV population were observed in uninoculated treatments indicating other bacterial strains were active in degradation of microcystin LR, Pilot scale biologically active slow sand filters demonstrated degradation of microcystin LR irrespective of MJ-PV bacterial inoculation. PCR analysis detected the MJ-PV population at all locations within the sand filters where microcystin degradation was measured. Despite not observing enhanced degradation of microcystin LR in inoculated columns compared to uninoculated column, these studies demonstrate the effectiveness of a low-technology water treatment system like biologically active slow sand filters for removal of microcystins from reticulated water supplies. Crown Copyright (c) 2006 Published by Elsevier Ltd. All rights reserved.
Resumo:
Objectives. It has been proposed that disruption of the internal proprioceptive representation, via incongruent sensory input, may underpin pathological pain states, but experimental evidence relies on conflicting visual input, which is not clinically relevant. We aimed to determine the symptomatic effect of incongruent proprioceptive input, imparted by vibration of the wrist tendons, which evokes the illusion of perpetual wrist flexion and disrupts cortical proprioceptive representation. Methods. Twenty-nine healthy and naive volunteers reported symptoms during five conditions: control, active and passive wrist flexion, extensor carpi radialis tendon vibration to evoke illusion of perpetual wrist flexion, and ulnar styloid (sham) vibration. No advice was given about possible illusions. Results. Twenty-one subjects reported the illusion of perpetual wrist flexion during tendon vibration. There was no effect of condition or of whether or not subjects reported an illusion on discomfort/pain (P > 0.28). Peculiarity, swelling and foreignness were greater during tendon vibration than during the other conditions, and greater during tendon vibration in those who reported an illusion of wrist flexion than in those who did not (P < 0.05 for all). Symptoms were reported by at least two subjects in each condition and four subjects reported systemic symptoms (e.g. nausea). Conclusions. In healthy volunteers, incongruent proprioceptive input does not cause discomfort or pain but does evoke feelings of peculiarity, swelling and foreignness in the limb.
Resumo:
Designer peptides have recently been developed as building blocks for novel self-assembled materials with stimuli-responsive properties. To date, such materials have been based on self-assembly in bulk aqueous solution or at solid-fluid interfaces. We have designed a 21-residue peptide, AM1, as a stimuli-responsive surfactant that switches molecular architectures at a fluid-fluid interface in response to changes in bulk aqueous solution composition. In the presence of divalent zinc at neutral pH, the peptide forms a mechanically strong 'film state'. In the absence of metal ions or at acid pH, the peptide adsorbs to form a mobile 'detergent state'. The two interfacial states can be actively and reversibly switched. Switching between the two states by a change in pH or the addition of a chelating agent leads to rapid emulsion coalescence or foam collapse. This work introduces a new class of surfactants that offer an environmentally friendly approach to control the stability of interfaces in foams, emulsions and fluid-fluid interfaces more generally.
Resumo:
Acuity for elbow joint position sense (JPS) is reduced when head position is modified. Movement of the head is associated with biomechanical changes in the neck and shoulder musculoskeletal system, which may explain changes in elbow JPS. The present study aimed to determine whether elbow JPS is also influenced by illusory changes in head position. Simultaneous vibration of sternocleidomastoid (SCM) and the contralateral splenius was applied to 14 healthy adult human subjects. Muscle vibration or passive head rotation was introduced between presentation and reproduction of a target elbow position. Ten out of 14 subjects reported illusions consistent with lengthening of the vibrated muscles. In these 10 subjects, absolute error for elbow JPS increased with left SCM/right splenius vibration but not with right SCM/left splenius vibration. Absolute error also increased with right rotation, with a trend for increased error with left rotation. These results demonstrated that both actual and illusory changes in head position are associated with diminished acuity for elbow JPS, suggesting that the influence of head position on upper limb JPS depends, at least partially, on perceived head position.
Resumo:
Hypercoiling polymers can be suited for application to living systems because they are similar in structure to the protein-based lipid assemblies found at fluid interfaces within the body. This leads to a range of exciting possibilities, not only in membrane transport applications but also in biosensors, drug delivery and mechanistic studies of biological membrane function. This study is focused in the study of the stability and suitability of nanostructures made of a hypercoiling polymer for drug delivery applications. The polymer poly (styrene-maleic acid) (PSMA) was combined with the phospholipid dimyristoylphosphatidylcholine (DMPC) to form amphiphilic nanostructures. The stability and suitability of these polymer-phospholipid nanocarriers for hydrophobic and hydrophilic molecules load and release was analyzed by several techniques. It was found that several of the studied molecules had a substantial effect on the surface charge and stability of the nanocarrier. It was also demonstrated that two types of nanocarriers, chemically modified and unmodified, were able to control the release of the molecules, especially in the case of hydrophobic compounds. In addition, as the hydrophobicity increased the release slowed down. These clear nanocarriers have the potential to behave very favorably at interfaces such as the tear lipid film were transparency is a requirement, giving a new way of controlled drug release in the eye.
Resumo:
Synchronous, time-resolved DRIFTS/MS/XAS cycling studies of the vapor-phase selective aerobic oxidation of crotyl alcohol over nanoparticulate Pd have revealed surface oxide as the desired catalytically active phase, with dynamic, reaction-induced Pd redox processes controlling selective versus combustion pathways.
Resumo:
Whole Body Vibrations consist of a vibration stimulus mechanically transferred to the body. The impact of vibration treatment on specific muscular activity, neuromuscular, and postural control has been widely studied. We investigated whole body vibration (WBV) effect on oxygen uptake and electromyographic signal of the rectus femoris muscle during static and dynamic squat. Fourteen healthy subjects performed a static and dynamic squat with and without vibration. During the vibration exercises, a significant increase was found in oxygen uptake (P=0.05), which increased by 44% during the static squat and 29.4% during the dynamic squat. Vibration increased heart rate by 11.1 ± 9.1 beats.min-1 during the static squat and 7.9 ± 8.3 beats.min-1 during the dynamic squat. No significant changes were observed in rate of perceived exertion between the exercises with and without vibration. The results indicate that the static squat with WBV produced higher neuromuscular and cardiorespiratory system activation for exercise duration ?60 sec. Otherwise, if the single bout duration was higher than 60 sec, the greater cardiorespiratory system activation was achieved during the dynamic squat with WBV while higher neuromuscular activation was still obtained with the static exercise.
Resumo:
High-volume capacitance is required to buffer the power difference between the input and output ports in single-phase grid-connected photovoltaic inverters, which become an obstacle to high system efficiency and long device lifetime. Furthermore, total harmonic distortion becomes serious when the system runs into low power level. In this study, a comprehensive analysis is introduced for two-stage topology with the consideration of active power, DC-link (DCL) voltage, ripple and capacitance. This study proposed a comprehensive DCL voltage control strategy to minimise the DCL capacitance while maintaining a normal system operation. Furthermore, the proposed control strategy is flexible to be integrated with the pulse-skipping control that significantly improves the power quality at light power conditions. Since the proposed control strategy needs to vary DCL voltage, an active protection scheme is also introduced to prevent any voltage violation across the DCL. The proposed control strategy is evaluated by both simulation and experiments, whose results confirm the system effectiveness.
Resumo:
Switched reluctance motors (SRMs) are gaining in popularity because of their robustness, low cost, and excellent high-speed characteristics. However, they are known to cause vibration and noise primarily due to the radial pulsating force resulting from their double-saliency structure. This paper investigates the effect of skewing the stator and/or rotor on the vibration reduction of the three-phase SRMs by developing four 12/8-pole SRMs, including a conventional SRM, a skewed rotor-SRM (SR-SRM), a skewed stator-SRM (SS-SRM), and a skewed stator and rotor-SRM (SSR-SRM). The radial force distributed on the stator yoke under different skewing angles is extensively studied by the finite-element method and experimental tests on the four prototypes. The inductance and torque characteristics of the four motors are also compared, and a control strategy by modulating the turn-ON and turn-OFF angles for the SR-SRM and the SS-SRM are also presented. Furthermore, experimental results validate the numerical models and the effectiveness of the skewing in reducing the motor vibration. Test results also suggest that skewing the stator is more effective than skewing the rotor in the SRMs.
Resumo:
The use of canines as a method of detection of explosives is well established worldwide and those applying this technology range from police forces and law enforcement to humanitarian agencies in the developing world. Despite the recent surge in publication of novel instrumental sensors for explosives detection, canines are still regarded by many to be the most effective real-time field method of explosives detection. However, unlike instrumental methods, currently it is difficult to determine detection levels, perform calibration of the canines' ability or produce scientifically valid quality control checks. Accordingly, amongst increasingly strict requirements regarding forensic evidence admission such as Frye and Daubert, there is a need for better scientific understanding of the process of canine detection. ^ When translated to the field of canine detection, just like any instrumental technique, peer reviewed publication of the reliability, success and error rates, is required for admissibility. Commonly training is focussed towards high explosives such as TNT and Composition 4, and the low explosives such as Black and Smokeless Powders are added often only for completeness. ^ Headspace analyses of explosive samples, performed by Solid Phase Microextraction (SPME) paired with Gas Chromatography - Mass Spectrometry (GC-MS), and Gas Chromatography - Electron Capture Detection (GC-ECD) was conducted, highlighting common odour chemicals. The odour chemicals detected were then presented to previously trained and certified explosives detection canines, and the activity/inactivity of the odour determined through field trials and experiments. ^ It was demonstrated that TNT and cast explosives share a common odour signature, and the same may be said for plasticized explosives such as Composition C-4 and Deta Sheet. Conversely, smokeless powders were demonstrated not to share common odours. An evaluation of the effectiveness of commercially available pseudo aids reported limited success. The implications of the explosive odour studies upon canine training then led to the development of novel inert training aids based upon the active odours determined. ^
Resumo:
Context: While research suggests whole body vibration (WBV) positively affects measures of neuromuscular performance in athletes, researchers have yet to address appropriate and effective vibration protocols. Objective: To identify the acute effects of continuous and intermittent WBV on muscular power and agility in recreationally active females. Design: We used a randomized 3-period cross-over design to observe the effects of 3 vibration protocols on muscular power and agility. Setting: Sports Science and Medicine Research Laboratory at Florida International University. Patients or Other Participants: Eleven recreationally active female volunteers (age=24.4±5.7y; ht=166.0±10.3cm; mass=59.7±14.3kg). Interventions: Each session, subjects stood on the Galileo WBV platform (Orthometrix, White Plains, NY) and received one of three randomly assigned vibration protocols. Our independent variable was vibration length (continuous, intermittent, or no vibration). Main Outcome Measures: An investigator blinded to the vibration protocol measured muscular power and agility. We measured muscular power with heights of squat and countermovement jumps. We measured agility with the Illinois Agility Test. Results: Continuous WBV significantly increased SJ height from 97.9±7.6cm to 98.5±7.5cm (P=0.019, β=0.71, η2 =0.07) but not CMJ height [99.1±7.4cm pretest and 99.4±7.4cm posttest (P=0.167, β=0.27)] or agility [19.2±2.1s pretest and 19.0±2.1s posttest (P=0.232, β=0.21)]. Intermittent WBV significantly enhanced SJ height from 97.6±7.7cm to 98.5±7.7cm (P=0.017, β=0.71, η2 =0.11) and agility 19.4±2.2s to 19.0±2.1s (P=0.001, β=0.98, η2=0.16), but did not effect CMJ height [98.7±7.7cm pretest and 99.3±7.3cm posttest (P=0.058, β=0.49)]. Conclusion: Continuous WBV increased squat jump height, while intermittent vibration enhanced agility and squat jump height. Future research should continue investigating the effect of various vibration protocols on athletic performance.
Resumo:
Context: Clinicians use exercises in rehabilitation to enhance sensorimotor-function, however evidence supporting their use is scarce. Objective: To evaluate acute effects of handheld-vibration on joint position sense (JPS). Design: A repeated-measure, randomized, counter-balanced 3-condition design. Setting: Sports Medicine and Science Research Laboratory. Patients or Other Participants: 31 healthy college-aged volunteers (16-males, 15-females; age=23+3y, mass=76+14kg, height=173+8cm). Interventions: We measured elbow JPS and monitored training using the Flock-of-Birds system (Ascension Technology, Burlington, VT) and MotionMonitor software (Innsport, Chicago, IL), accurate to 0.5°. For each condition (15,5,0Hz vibration), subjects completed three 15-s bouts holding a 2.55kg Mini-VibraFlex dumbbell (Orthometric, New York, NY), and used software-generated audio/visual biofeedback to locate the target. Participants performed separate pre- and post-test JPS measures for each condition. For JPS testing, subjects held a non-vibrating dumbbell, identified the target (90°flexion) using biofeedback, and relaxed 3-5s. We removed feedback and subjects recreated the target and pressed a trigger. We used SPSS 14.0 (SPSS Inc., Chicago, IL) to perform separate ANOVAs (p<0.05) for each protocol and calculated effect sizes using standard-mean differences. Main Outcome Measures: Dependent variables were absolute and variable error between target and reproduced angles, pre-post vibration training. Results: 0Hz (F1,61=1.310,p=0.3) and 5Hz (F1,61=2.625,p=0.1) vibration did not affect accuracy. 15Hz vibration enhanced accuracy (6.5±0.6 to 5.0±0.5°) (F1,61=8.681,p=0.005,ES=0.3). 0Hz did not affect variability (F1,61=0.007,p=0.9). 5Hz vibration decreased variability (3.0±1.8 to 2.3±1.3°) (F1,61=7.250,p=0.009), as did 15Hz (2.8±1.8 to 1.8±1.2°) (F1,61=24.027, p<0.001). Conclusions: Our results support using handheld-vibration to improve sensorimotor-function. Future research should include injured subjects, functional multi-joint/multi-planar measures, and long-term effects of similar training.
Resumo:
Smart structures and systems have the main purpose to mimic living organisms, which are essentially characterized by an autoregulatory behavior. Therefore, this kind of structure has adaptive characteristics with stimulus-response mechanisms. The term adaptive structure has been used to identify structural systems that are capable of changing their geometry or physical properties with the purpose of performing a specific task. In this work, a sliding mode controller with fuzzy inference is applied for active vibration control in an SMA two-bar truss. In order to obtain a simpler controller, a polynomial model is used in the control law, while a more sophisticated version, which presents close agreement with experimental data, is applied to describe the SMA behavior of the structural elements. This system has a rich dynamic response and can easily reach a chaotic behavior even at moderate loads and frequencies. Therefore, this approach has the advantage of not only obtaining a simpler control law, but also allows its robustness be evidenced. Numerical simulations are carried out in order to demonstrate the control system performance.