997 resultados para ventricular volume
Resumo:
Background. We assessed end-diastolic right ventricular (RV) dimensions and left ventricular (LV) ejection fraction by use of intraoperative transesophageal echocardiography before and after surgical correction of pectus excavatum in adults. Methods. A prospective study was conducted including 17 patients undergoing surgical correction of pectus excavatum according to the technique of Ravitch-Shamberger between 1999 and 2004. Intraoperative transesophageal echocardiography was performed under general anesthesia before and after surgery to assess end-diastolic RV dimensions and LV ejection fraction. The end-diastolic RV diameter and area were measured in four-chamber and RV inflow-outflow view, and the RV volume was calculated from these data. The LV was assessed by transgastric short-axis view, and its ejection fraction was calculated by use of the Teichholz formula. Results. The end-diastolic RV diameter, area, and volume all significantly increased after surgery (mean values +/- SD, respectively: 2.4 +/- 0.8 cm versus 3.0 +/- 0.9 cm, p < 0.001; 12.5 +/- 5.2 cm(2) versus 18.4 +/- 7.5 cm(2), p < 0.001; and 21.7 +/- 11.7 mL versus 40.8 +/- 23 mL, p < 0.001). The LV ejection fraction also significantly increased after surgery (58.4% +/- 15% versus 66.2% +/- 6%, p < 0.001). Conclusions. Surgical correction of pectus excavatum according to Ravitch-Shamberger technique results in a significant increase in end-diastolic RV dimensions and a significantly increased LV ejection fraction. (Ann Thorac Surg 2010; 89: 240-4) (C) 2010 by The Society of Thoracic Surgeons
Resumo:
Business news from the Iowa Department of Economic Development
Resumo:
BACKGROUND Catecholaminergic polymorphic ventricular tachycardia (CPVT) is an arrhythmogenic disease for which electrophysiological studies (EPS) have shown to be of limited value.OBJECTIVE This study presents a CPVT family in which marked postpacing repolarization abnormalities during EPS were the only consistent phenotypic manifestation of ryanodine receptor (RyR2) mutation carriers.METHODS The study was prompted by the observation of transient marked QT prolongation preceding initiation of ventricular fibrillation during atrial fibrillation in a boy with a family history of sudden cardiac death (SCD). Family members underwent exercise and pharmacologic electrocardiographic testing with epinephrine, adenosine, and flecainide. Noninvasive clinical test results were normal in 10 patients evaluated, except for both epinephrine- and exercise-induced ventricular arrhythmias in 1. EPS included bursts of ventricular pacing and programmed ventricular extrastimulation reproducing short-long sequences. Genetic screening involved direct sequencing of genes involved in long QT syndrome as well as RyR2.RESULTS Six patients demonstrated a marked increase in QT interval only in the first beat after cessation of ventricular pacing and/or extrastimulation. All 6 patients were found to have a heterozygous missense mutation (M4109R) in RyR2. Two of them, presenting with aborted SCD, also had a second missense mutation (I406T- RyR2). Four family members without RyR2 mutations did not display prominent postpacing QT changes.CONCLUSION M4109R- RyR2 is associated with a high incidence of SCD. The contribution of I406T to the clinical phenotype is unclear. In contrast to exercise testing, marked postpacing repolarization changes in a single beat accurately predicted carriers of M4109R- RyR2 in this family.
Resumo:
We hypothesized that acute volume expansion by saline infusion triggers the release of endothelin-1. Bolus intravenous saline infusion (8 mL/min) in six groups of conscious Wistar rats and spontaneously hypertensive rats did not change mean arterial pressure or heart rate (n = 8 to 12). At 1 min after infusion, the plasma endothelin-1 level was significantly increased in Wistar rats and in spontaneously hypertensive rats by 42% and 61%, respectively (unpaired data). In 12 Wistar rats, the endothelin-1 level increased from 0.68 +/- 0.13 to 1.19 +/- 0.17 fmol/mL (mean +/- SEM, P <.0001, paired data). Thus, acute volume load by rapid saline infusion increases plasma endothelin-1 levels. Vasoconstriction induced by endothelin-1 may counteract enhanced circumferential stretch created by volume expansion.
Resumo:
Researchers have used stylized facts on asset prices and trading volumein stock markets (in particular, the mean reversion of asset returnsand the correlations between trading volume, price changes and pricelevels) to support theories where agents are not rational expected utilitymaximizers. This paper shows that this empirical evidence is in factconsistent with a standard infite horizon perfect information expectedutility economy where some agents face leverage constraints similar tothose found in todays financial markets. In addition, and in sharpcontrast to the theories above, we explain some qualitative differencesthat are observed in the price-volume relation on stock and on futuresmarkets. We consider a continuous-time economy where agents maximize theintegral of their discounted utility from consumption under both budgetand leverage con-straints. Building on the work by Vila and Zariphopoulou(1997), we find a closed form solution, up to a negative constant, for theequilibrium prices and demands in the region of the state space where theconstraint is non-binding. We show that, at the equilibrium, stock holdingsvolatility as well as its ratio to stock price volatility are increasingfunctions of the stock price and interpret this finding in terms of theprice-volume relation.
Resumo:
Objectives: Existing VADs are single-ventricle pumps needing anticoagulation. We developed a bi-ventricular external assist device that partially reproduces the physiological muscle function of the heart. This artificial muscle could wrap the heart and improve its contractile force.Methods: The device has a carbon fiber skeleton fitting a 30-40kg patient's heart, to which a Nitinol based artificial muscle is connected. The artificial muscle wraps both ventricles. The Nitinol fibers are woven on a Kevlar mesh surrounding each ventricle. The fibers are electrically driven with a dedicated control unit developed for this purpose. We assessed hemodynamic performances of this device using a previously described dedicated bench test. Volume ejected and pressure gradient have been measured with afterload ranging from 10 to 50mmHg.Results: With an afterload of 50mmHg the system has an ejection fraction of 4% on the right side and 5% on the left side. The system is able to generate a systolic ejection of 2.2mL on the right side and 3.25mL on the left side. With an afterload of 25mmHg the results are reduced of about 20%. The activation frequency can reach 80/minute resulting in a total volume displacement of 176mL/minute on the right side and 260mL/minute on the left side.Conclusions: These preliminary studies confirmed the possibility of improving the ejection fraction of a failing heart using artificial muscle for external cardiac compression avoiding anticoagulation therapy. This device could be helpful in weaning cardio-pulmonary bypass and/or for short-term cardio-circulatory support in pediatric population with cardiac failure.
Resumo:
AIMS: The aim of this study was to investigate the heritability as well as genetic and environmental correlations of left ventricular (LV) structural and functional traits in complex pedigrees of a Caucasian population. METHODS AND RESULTS: We randomly recruited 459 white European subjects from 52 families (50% women; mean age 45 years). LV structure was measured by M-mode and 2D echocardiography and LV function was measured by conventional Doppler and tissue Doppler imaging (TDI). Other measurements included blood pressure, anthropometric, and biochemical measurements. We estimated the heritability of LV traits while adjusting for covariables, including sex, age, body height and weight, systolic and diastolic blood pressures, and heart rate. With full adjustment, heritability of LV mass was 0.23 (P= 0.025). The TDI-derived mitral annular velocities Ea and Aa showed moderate heritability (h(2)= 0.36 and 0.53, respectively), whereas the mitral inflow A peak had weak heritability (h(2) = 0.25) and the E peak was not heritable (h(2) = 0.11). We partitioned the total phenotypic correlation when it reached significance, into a genetic and an environmental component. The genetic correlations were 0.61 between the E and Ea peaks and 0.90 between the A and Aa peaks. CONCLUSION: Our study demonstrated moderate heritability for LV mass as well as the mitral annular Ea and Aa peaks. We also found significant genetic correlations between the E and Ea peaks and between the A and Aa peaks. Our current findings support the ongoing research to map and detect genetic variants that contribute to the variation in LV mass and other LV structural and functional phenotypes.
Resumo:
BACKGROUND AND PURPOSE: To compare the delineations and interpretations of target volumes by physicians in different radio-oncology centers. MATERIALS AND METHODS: Eleven Swiss radio-oncology centers delineated volumes according to ICRU 50 recommendations for one prostate and one head and neck case. In order to evaluate the consistency of the volume delineations, the following parameters were determined: 1) the target volumes (GTV, CTV and manually expanded PTV) and their extensions in the three main axes and 2) the correlation of the volume delineated by each pair of centers using the ratio of the intersection to the union (called proximity index). RESULTS: The delineated prostate volume was 105+/-55cm(3) for the CTV and 218+/-44cm(3) for the PTV. The delineated head and neck volume was 46+/-15cm(3) for the GTV, 327+/-154cm(3) for the CTV and 528+/-106cm(3) for the PTV. The mean proximity index for the prostate case was 0.50+/-0.13 for the CTV and 0.57+/-0.11 for the PTV. The proximity index for the head and neck case was 0.45+/-0.09 for the GTV, 0.42+/-0.13 for the CTV and 0.59+/-0.06 for the PTV. CONCLUSIONS: Large discrepancies between all the delineated target volumes were observed. There was an inverse relationship between the CTV volume and the margin between CTV and PTV, leading to less discrepancies in the PTV than is the CTV delineations. There was more spread in the sagittal and frontal planes due to CT pixel anisotropy, which suggests that radiation oncologists should delineate the target volumes not only in the transverse plane, but also in the sagittal and frontal planes to improve the delineation by allowing a consistency check.
Resumo:
Business news from the Iowa Department of Economic Development
Resumo:
A periodic e-newsletter from the Iowa Tourism Office for group tour planners that focuses on "new, unusual, and just plain different" opportunities for group travelers.
Resumo:
PURPOSE: The Gastro-Intestinal Working Party of the EORTC Radiation Oncology Group (GIWP-ROG) developed guidelines for target volume definition in neoadjuvant radiation of adenocarcinomas of the gastroesophageal junction (GEJ) and the stomach. METHODS AND MATERIALS: Guidelines about the definition of the clinical target volume (CTV) are based on a systematic literature review of the location and frequency of local recurrences and lymph node involvement in adenocarcinomas of the GEJ and the stomach. Therefore, MEDLINE was searched up to August 2008. Guidelines concerning prescription, planning and treatment delivery are based on a consensus between the members of the GIWP-ROG. RESULTS: In order to support a curative resection of GEJ and gastric cancer, an individualized preoperative treatment volume based on tumour location has to include the primary tumour and the draining regional lymph nodes area. Therefore we recommend to use the 2nd English Edition of the Japanese Classification of Gastric Carcinoma of the Japanese Gastric Cancer Association which developed the concept of assigning tumours of the GEJ and the stomach to anatomically defined sub-sites corresponding respectively to a distinct lymphatic spread pattern. CONCLUSION: The GIWP-ROG defined guidelines for preoperative irradiation of adenocarcinomas of the GEJ and the stomach to reduce variability in the framework of future clinical trials.
Resumo:
Business News from the Iowa Department of Economic Development
Resumo:
Acute myocardial dysfunction is a typical manifestation of septic shock. Experimentally, the administration of endotoxin [lipopolysacharride (LPS)] to laboratory animals is frequently used to study such dysfunction. However, a majority of studies used load-dependent indexes of cardiac function [including ejection fraction (EF) and maximal systolic pressure increment (dP/dt(max))], which do not directly explore cardiac inotropism. Therefore, we evaluated the direct effects of LPS on myocardial contractility, using left ventricular (LV) pressure-volume catheters in mice. Male BALB/c mice received an intraperitoneal injection of E. coli LPS (1, 5, 10, or 20 mg/kg). After 2, 6, or 20 h, cardiac function was analyzed in anesthetized, mechanically ventilated mice. All doses of LPS induced a significant drop in LV stroke volume and a trend toward reduced cardiac output after 6 h. Concomitantly, there was a significant decrease of LV preload (LV end-diastolic volume), with no apparent change in LV afterload (evaluated by effective arterial elastance and systemic vascular resistance). Load-dependent indexes of LV function were markedly reduced at 6 h, including EF, stroke work, and dP/dt(max). In contrast, there was no reduction of load-independent indexes of LV contractility, including end-systolic elastance (ejection phase measure of contractility) and the ratio dP/dt(max)/end-diastolic volume (isovolumic phase measure of contractility), the latter showing instead a significant increase after 6 h. All changes were transient, returning to baseline values after 20 h. Therefore, the alterations of cardiac function induced by LPS are entirely due to altered loading conditions, but not to reduced contractility, which may instead be slightly increased.
Resumo:
Business news from the Iowa Department of Economic Development