980 resultados para template overlap method top ATLAS
Resumo:
Sustainable Construction, Materials and Practice, p. 426-432
Resumo:
We show here a simplified RT-PCR for identification of dengue virus types 1 and 2. Five dengue virus strains, isolated from Brazilian patients, and yellow fever vaccine 17DD as a negative control, were used in this study. C6/36 cells were infected and supernatants were collected after 7 days. The RT-PCR, done in a single reaction vessel, was carried out following a 1/10 dilution of virus in distilled water or in a detergent mixture containing Nonidet P40. The 50 µl assay reaction mixture included 50 pmol of specific primers amplifying a 482 base pair sequence for dengue type 1 and 210 base pair sequence for dengue type 2. In other assays, we used dengue virus consensus primers having maximum sequence similarity to the four serotypes, amplifying a 511 base pair sequence. The reaction mixture also contained 0.1 mM of the four deoxynucleoside triphosphates, 7.5 U of reverse transcriptase, 1U of thermostable Taq DNA polymerase. The mixture was incubated for 5 minutes at 37ºC for reverse transcription followed by 30 cycles of two-step PCR amplification (92ºC for 60 seconds, 53ºC for 60 seconds) with slow temperature increment. The PCR products were subjected to 1.7% agarose gel electrophoresis and visualized by UV light after staining with ethidium bromide solution. Low virus titer around 10 3, 6 TCID50/ml was detected by RT-PCR for dengue type 1. Specific DNA amplification was observed with all the Brazilian dengue strains by using dengue virus consensus primers. As compared to other RT-PCRs, this assay is less laborious, done in a shorter time, and has reduced risk of contamination
Resumo:
As aplicações móveis de serviços baseados na localização, denominados LBS (Location-based services), disponibilizam serviços ao utilizador baseadas na sua localização geográfica. Este tipo de serviços começou a surgir ainda na década de 90 e, à medida que o número de dispositivos móveis cresceu de forma exponencial, a sua oferta disparou consideravelmente. Existem várias áreas com aplicabilidade prática, mas o foco desta tese é a pesquisa e localização de pontos de interesse (POI’s). Através dos sensores que os dispositivos móveis atualmente disponibilizam, torna-se possível localizar a posição do utilizador e apresentar-lhe os pontos de interesse que estão situados em seu redor. No entanto essa informação isolada revela-se por vezes insuficiente, uma vez que esses pontos de interesse são à partida desconhecidos para o utilizador. Através do serviço coolplaces, um projeto que pretende dedicar-se à pesquisa e partilha de POI’s, podemos criar a nossa rede de amigos e de locais, beneficiando assim da respetiva informação de contexto de um determinado POI. As inovações tecnológicas permitiram também o aparecimento de aplicações de Realidade Aumentada nos dispositivos móveis, isto é, aplicações capazes de sobrepor imagens virtuais a visualizações do mundo real. Considerando a visualização de POI’s num dado ambiente, se encararmos a Realidade Aumentada como um potenciador da interação do utilizador com o mundo real, rapidamente identificamos as potencialidades da junção destes conceitos numa só aplicação. Sendo assim, o trabalho desenvolvido nesta tese pretende constituir um estudo sobre a implementação e desenvolvimento de um módulo de Realidade Aumentada para a aplicação móvel do serviço coolplaces, fazendo uso da tecnologia disponível no mercado de forma a proporcionar uma experiência inovadora e acrescentar valor à referida aplicação.
Resumo:
RESUMO: A cefaleia cervicogénica é uma forma comum de dor de cabeça, que tem sido associada à existência de uma disfunção das estruturas da coluna cervical superior. Estudos recentes mostram uma grande incidência dessa disfunção a nível de C1-C2, avaliada pelo teste de flexão-rotação. Vários terapeutas manuais, como Brian Mulligan e Mariano Rocabado, têm sido sugerido técnicas de tratamento para este tipo de disfunção. Contudo, a evidência acerca da efectividade dessas técnicas é escassa. Desenho do estudo: Foi efectuado um ensaio clínico aleatório, duplamente cego, composto por três fases: pré-intervenção, intervenção e pós-intervenção. Objectivos: Avaliar e comparar os efeitos imediatos de duas técnicas de Terapia Manual Ortopédica (SNAG C1/2 de Mulligan e técnica de desrotação do atlas de Rocabado), na amplitude de movimento de rotação do segmento vertebral C1-C2, em indivíduos com história de cefaleia cervicogénica e com limitação no teste de flexão-rotação. As técnicas de tratamento foram usadas de forma isolada, em comparação a um grupo placebo. Métodos: Uma amostra de 60 indivíduos, com cefaleia cervicogénica e limitação do teste de flexão-rotação, foram aleatoriamente distribuídos por três grupos: SNAG C1/2 de Mulligan, técnica de desrotação do atlas de Rocabado e grupo placebo. O outcome primário foi a amplitude de movimento obtida no teste de flexão-rotação, que foi medido antes e imediatamente após a intervenção. Resultados: Imediatamente após a intervenção, a amplitude verificada no teste de flexão-rotação aumentou 21.8º (DP, 4.68) no grupo submetido ao SNAG C1/2 de Mulligan, 15º (DP, 5.07) no grupo em que foi aplicada a técnica de desrotação do atlas de Rocabado e 0.65º (DP, 0.67) no grupo placebo. Uma ANOVA modelo misto, 2 por 3, revelou efeito principal significativo do tempo (p<.001) e grupo (p<.001), assim como uma interacção significativa entre grupo e tempo (p<.001), relativamente à variável amplitude do teste de flexão-rotação. Estes resultados indicam que as diferenças verificadas entre os grupos eram dependentes do momento de avaliação. Uma comparação múltipla post hoc revelou que quer as técnicas de Mulligan, quer de Rocabado, produziram efeitos significativamente maiores que a intervenção placebo na amplitude de movimento do teste de flexão-rotação (p<.001 e p=.001, respectivamente). No entanto,não se verificou uma diferença significativa no que diz respeito à efectividade de ambas as técnicas de Terapia Manual Ortopédica aplicadas (p=.42). Conclusão: Esta investigação sugere que as duas técnicas de Terapia Manual Ortopédica avaliadas produziram efeito clínica e estatisticamente significativo na amplitude do teste de flexão-rotação. No entanto, não se verificaram diferenças entre as duas técnicas, no que diz respeito ao seu efeito no ganho de amplitude de movimento. Os resultados obtidos fornecem evidência preliminar sobre a efectividade de ambas as intervenções no tratamento da redução de amplitude de movimento em indivíduos com história de cefaleia cervicogénica.-------------------------------ABSTRACT:Background: Cervicogenic headache is a common form of headache arising from dysfunction in structures of the upper cervical spine. Recent studies have shown a high incidence of C1/2 dysfunction, evaluated by the flexion-rotation test (FRT). Several manual therapists have suggested different approaches to manage that dysfunction, such as Brian Mulligan and Mariano Rocabado. However, the evidence of the effectiveness of those manual techniques is anedoctal. Design: Randomized double blinded controlled trial with three phases: pre-intervention, intervention and post-intervention. Objectives: To determine and compare the immediate effects of two manual therapy techniques (Mulligan’s SNAG C1/2 and Rocabado’s atlas’ derotation technique) in the range of motion of C1-C2 vertebral segments, in cervicogenic headache patients and with limitation on the flexion-rotatoin test. The treatment techniques were used as single treatments against a placebo group. Methods: A sample of 60 subjects with cervicogenic headache and FRT limitation were randomly allocated into one of three groups: Mulligan’s C1/2 SNAG, Rocabado’s atlas derotation technique or placebo group. The primary outcome was the flexion rotation test range, which was measured before and immediately after the intervention. Results: Immediately after the application of the interventions, FRT range increased by 21.8º (SD, 4.68) for the Mulligan’s C1-2 SNAG group, 15º (SD, 5.07) for the Rocabado’s atlas derotation technique and 0.65º (SD, 0.67) for the placebo group. A 2-by-3 mixedmodel ANOVA a significant main effect of time (p<.001) and group (p<.001), as well as a significant interaction between group and time (p<.001) for the variable FRT range. These results indicate that group differences were dependent on time. A pairwise post hoc comparison revelad that both the Mulligan and Rocabado techniques produced significantly more effect on FRT range of motion than the placebo intervention (p<.001 and p=.001, respectively). However, there was not a significant difference between the effectiveness of the two manual therapy techniques (p=.42).Conclusion: This investigation’s findings suggest that both Mulligan’s C1/2 SNAG and Rocabado’s atlas derotation techniques produced a clinically and statistically significant effect on FRT range, but there were no changes between the two techniques in their effectiveness. These results provide preliminary evidence for the efficacy of both manual therapy techniques in the management of individuals with cervicogenic headache and FRT limitation.
Resumo:
A comparison of the Etest and the reference broth macrodilution susceptibility test for fluconazole, ketoconazole, itraconazole and amphotericin B was performed with 59 of Candida species isolated from the oral cavities of AIDS patients. The Etest method was performed according to the manufacturer's instructions, and the reference method was performed according to National Committee for Clinical Laboratory Standards document M27-A guidelines. Our data showed that there was a good correlation between the MICs obtained by the Etest and broth dilution methods. When only the MIC results at ± 2 dilutions for both methods were considered, the agreement rates were 90.4% for itraconazole, ketoconazole and amphotericin B and 84.6% for fluconazole of the C. albicans tested. In contrast, to the reference method, the Etest method classified as susceptible three fluconazole-resistant isolates and one itraconazole-resistant isolate, representing four very major errors. These results indicate that Etest could be considered useful for antifungal sensitivity evaluation of yeasts in clinical laboratories.
Resumo:
Com a necessidade de encontrar uma forma de ligar componentes de forma mais vantajosa, surgiram as ligações adesivas. Nos últimos anos, a utilização de juntas adesivas em aplicações industriais tem vindo a aumentar, substituindo alguns métodos de ligação tradicionais, por apresentarem vantagens tais como, redução de concentração de tensões, reduzido peso e facilidade de processamento/fabrico. O seu estudo permite prever a sua resistência e durabilidade. Este trabalho refere-se ao estudo de juntas de sobreposição simples (JSS), nas quais são aplicados os adesivos comerciais que variam desde frágeis e rígidos, como o caso do Araldite® AV138, até adesivos mais dúcteis, como o Araldite® 2015 e o Sikaforce® 7888. Estes são aplicados em substratos de alumínio (AL6082-T651) em juntas com diferentes geometrias e diferentes comprimentos de sobreposição (L), sendo sujeitos a esforços de tracção. Foi feita uma análise dos valores experimentais fornecidos e uma posterior comparação destes com diferentes métodos numéricos baseados em Elementos Finitos (EF). A comparação foi feita por uma análise de Modelos de Dano Coesivo (MDC) e segundo os critérios baseados em tensões e deformações do Método de Elementos Finitos Extendido (MEFE). A utilização destes métodos numéricos capazes de simular o comportamento das juntas poderá levar a uma poupança de recursos e de tempo. A análise por MDC revelou que este método é bastante preciso, excepto para os adesivos que sejam bastante dúcteis. A aplicação de uma outra lei coesiva pode solucionar esse problema. Por sua vez a análise por MEFE demonstrou que esta técnica não é particularmente adequada para o crescimento de dano em modo misto e, comparativamente com o MDC, a sua precisão é bastante inferior.
Resumo:
Dissertação para obtenção do Grau de Doutor em Química Sustentável
Resumo:
This work proposes a novel approach for a suitable orientation of antibodies (Ab) on an immunosensing platform, applied here to the determination of 8-hydroxy-2′-deoxyguanosine (8OHdG), a biomarker of oxidative stress that has been associated to chronic diseases, such as cancer. The anti-8OHdG was bound to an amine modified gold support through its Fc region after activation of its carboxylic functions. Non-oriented approaches of Ab binding to the platform were tested in parallel, in order to show that the presented methodology favored Ab/Ag affinity and immunodetection of the antigen. The immunosensor design was evaluated by quartz-crystal microbalance with dissipation, atomic force microscopy, electrochemical impedance spectroscopy (EIS) and square-wave voltammetry. EIS was also a suitable technique to follow the analytical behavior of the device against 8OHdG. The affinity binding between 8OHdG and the antibody immobilized in the gold modified platform increased the charge transfer resistance across the electrochemical set-up. The observed behavior was linear from 0.02 to 7.0 ng/mL of 8OHdG concentrations. The interference from glucose, urea and creatinine was found negligible. An attempt of application to synthetic samples was also successfully conducted. Overall, the presented approach enabled the production of suitably oriented Abs over a gold platform by means of a much simpler process than other oriented-Ab binding approaches described in the literature, as far as we know, and was successful in terms of analytical features and sample application.
Resumo:
Carnitine (CRT) is a biological metabolite found in urine that contributes in assessingseveral disease conditions, including cancer. Novel quick screening procedures for CRT are therefore fundamental. This work proposes a novel potentiometric device where molecularly imprinted polymers (MIPs) were used as ionophores. The host-tailored sites were imprinted on a polymeric network assembled by radical polymerization of methacrylic acid (MAA) and trimethylpropane trimethacrylate (TRIM). Non-imprinted polymers (NIPs) were produced as control by removing the template from the reaction media. The selective membrane was prepared by dispersing MIP or NIP particles in plasticizer and poly(vinyl chloride), PVC, and casting this mixture over a solid contact support made of graphite. The composition of the selective membrane was investigated with regard to kind/amount of sensory material (MIP or NIP), and the need for a lipophilic additive. Overall, MIP sensors with additive exhibited the best performance, with near-Nernstian response down to ~ 1 × 10− 4 mol L− 1, at pH 5, and a detection limitof ~ 8 × 10− 5 mol L− 1. Suitable selectivity was found for all membranes, assessed by the matched potential method against some of the most common species in urine (urea, sodium, creatinine, sulfate, fructose and hemoglobin). CRT selective membranes including MIP materials were applied successfully to the potentiometric determination of CRT in urine samples.
Resumo:
A low-cost disposable was developed for rapid detection of the protein biomarker myoglobin (Myo) as a model analyte. A screen printed electrode was modified with a molecularly imprinted material grafted on a graphite support and incorporated in a matrix composed of poly(vinyl chloride) and the plasticizer o-nitrophenyloctyl ether. The protein-imprinted material (PIM) was produced by growing a reticulated polymer around a protein template. This is followed by radical polymerization of 4-styrenesulfonic acid, 2-aminoethyl methacrylate hydrochloride, and ethylene glycol dimethacrylate. The polymeric layer was then covalently bound to the graphitic support, and Myo was added during the imprinting stage to act as a template. Non-imprinted control materials (CM) were also prepared by omitting the Myo template. Morphological and structural analysis of PIM and CM by FTIR, Raman, and SEM/EDC microscopies confirmed the modification of the graphite support. The analytical performance of the SPE was assessed by square wave voltammetry. The average limit of detection is 0.79 μg of Myo per mL, and the slope is −0.193 ± 0.006 μA per decade. The SPE-CM cannot detect such low levels of Myo but gives a linear response at above 7.2 μg · mL−1, with a slope of −0.719 ± 0.02 μA per decade. Interference studies with hemoglobin, bovine serum albumin, creatinine, and sodium chloride demonstrated good selectivity for Myo. The method was successfully applied to the determination of Myo urine and is conceived to be a promising tool for screening Myo in point-of-care patients with ischemia.
Resumo:
This work introduces two major changes to the conventional protocol for designing plastic antibodies: (i) the imprinted sites were created with charged monomers while the surrounding environment was tailored using neutral material; and (ii) the protein was removed from its imprinted site by means of a protease, aiming at preserving the polymeric network of the plastic antibody. To our knowledge, these approaches were never presented before and the resulting material was named here as smart plastic antibody material (SPAM). As proof of concept, SPAM was tailored on top of disposable gold-screen printed electrodes (Au-SPE), following a bottom-up approach, for targeting myoglobin (Myo) in a point-of-care context. The existence of imprinted sites was checked by comparing a SPAM modified surface to a negative control, consisting of similar material where the template was omitted from the procedure and called non-imprinted materials (NIMs). All stages of the creation of the SPAM and NIM on the Au layer were followed by both electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). AFM imaging was also performed to characterize the topography of the surface. There are two major reasons supporting the fact that plastic antibodies were effectively designed by the above approach: (i) they were visualized for the first time by AFM, being present only in the SPAM network; and (ii) only the SPAM material was able to rebind to the target protein and produce a linear electrical response against EIS and square wave voltammetry (SWV) assays, with NIMs showing a similar-to-random behavior. The SPAM/Au-SPE devices displayed linear responses to Myo in EIS and SWV assays down to 3.5 μg/mL and 0.58 μg/mL, respectively, with detection limits of 1.5 and 0.28 μg/mL. SPAM materials also showed negligible interference from troponin T (TnT), bovine serum albumin (BSA) and urea under SWV assays, showing promising results for point-of-care applications when applied to spiked biological fluids.
Resumo:
The total antioxidant capacity (TAC) of 28 flavoured water samples was assessed by ferric reducing antioxidant potential (FRAP), oxygen radical absorbance capacity (ORAC), trolox equivalent antioxidant capacity (TEAC) and total reactive antioxidant potential (TRAP) methods. It was observed that flavoured waters had higher antioxidant activity than the corresponding natural ones. The observed differences were attributed to flavours, juice and vitamins. Generally, higher TAC contents were obtained on lemon waters and lower values on guava and raspberry flavoured waters. Lower and higher TACs were obtained by TRAP and ORAC method, respectively. Statistical analysis suggested that vitamins and flavours increased the antioxidant content of the commercial waters.