984 resultados para synchronized phasor measurement unit


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Winter weather in Iowa is often unpredictable and can have an adverse impact on traffic flow. The Iowa Department of Transportation (Iowa DOT) attempts to lessen the impact of winter weather events on traffic speeds with various proactive maintenance operations. In order to assess the performance of these maintenance operations, it would be beneficial to develop a model for expected speed reduction based on weather variables and normal maintenance schedules. Such a model would allow the Iowa DOT to identify situations in which speed reductions were much greater than or less than would be expected for a given set of storm conditions, and make modifications to improve efficiency and effectiveness. The objective of this work was to predict speed changes relative to baseline speed under normal conditions, based on nominal maintenance schedules and winter weather covariates (snow type, temperature, and wind speed), as measured by roadside weather stations. This allows for an assessment of the impact of winter weather covariates on traffic speed changes, and estimation of the effect of regular maintenance passes. The researchers chose events from Adair County, Iowa and fit a linear model incorporating the covariates mentioned previously. A Bayesian analysis was conducted to estimate the values of the parameters of this model. Specifically, the analysis produces a distribution for the parameter value that represents the impact of maintenance on traffic speeds. The effect of maintenance is not a constant, but rather a value that the researchers have some uncertainty about and this distribution represents what they know about the effects of maintenance. Similarly, examinations of the distributions for the effects of winter weather covariates are possible. Plots of observed and expected traffic speed changes allow a visual assessment of the model fit. Future work involves expanding this model to incorporate many events at multiple locations. This would allow for assessment of the impact of winter weather maintenance across various situations, and eventually identify locations and times in which maintenance could be improved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our police work against human trafficking started in 2004 on behalf of the government. (Police Department received 300 000 euros which was divided between the three largest cities in Sweden, Stockholm, Gothenburg and Malmö. Then, each police district had to find out how .THB looked like in their district and how it best could be combated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Empirical antibacterial therapy in hospitals is usually guided by local epidemiologic features reflected by institutional cumulative antibiograms. We investigated additional information inferred by aggregating cumulative antibiograms by type of unit or according to the place of acquisition (i.e. community vs. hospital) of the bacteria. MATERIALS AND METHODS: Antimicrobial susceptibility rates of selected pathogens were collected over a 4-year period in an university-affiliated hospital. Hospital-wide antibiograms were compared with those selected by type of unit and sampling time (<48 or >48 h after hospital admission). RESULTS: Strains isolated >48 h after admission were less susceptible than those presumably arising from the community (<48 h). The comparison of units revealed significant differences among strains isolated >48 h after admission. When compared to hospital-wide antibiograms, susceptibility rates were lower in the ICU and surgical units for Escherichia coli to amoxicillin-clavulanate, enterococci to penicillin, and Pseudomonas aeruginosa to anti-pseudomonal beta-lactams, and in medical units for Staphylococcus aureus to oxacillin. In contrast, few differences were observed among strains isolated within 48 h of admission. CONCLUSIONS: Hospital-wide antibiograms reflect the susceptibility pattern for a specific unit with respect to community-acquired, but not to hospital-acquired strains. Antibiograms adjusted to these parameters may be useful in guiding the choice of empirical antibacterial therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Antiresorptive agents such as bisphosphonates induce a rapid increase of BMD during the 1st year of treatment and a partial maintenance of bone architecture. Trabecular Bone Score (TBS), a new grey-level texture measurement that can be extracted from the DXA image, correlates with 3D parameters of bone micro-architecture. Aim: To evaluate the longitudinal effect of antiresorptive agents on spine BMD and on site-matched spine microarchitecture as assessed by TBS. Methods: From the BMD database for Province of Manitoba, Canada, we selected women age >50 with paired baseline and follow up spine DXA examinations who had not received any prior HRT or other antiresorptive drug.Women were divided in two subgroups: (1) those not receiving any HRT or antiresorptive drug during follow up (=non-users) and (2) those receiving non-HRT antiresorptive drug during follow up (=users) with high adherence (medication possession ratio >75%) from a provincial pharmacy database system. Lumbar spine TBS was derived by the Bone Disease Unit, University of Lausanne, for each spine DXA examination using anonymized files (blinded from clinical parameters and outcomes). Effects of antiresorptive treatment for users and non-users on TBS and BMD at baseline and during mean 3.7 years follow-up were compared. Results were expressed % change per year. Results: 1150 non-users and 534 users met the inclusion criteria. At baseline, users and non-users had a mean age and BMI of [62.2±7.9 vs 66.1±8.0 years] and [26.3±4.7 vs 24.7±4.0 kg/m²] respectively. Antiresorptive drugs received by users were bisphosphonates (86%), raloxifene (10%) and calcitonin (4%). Significant differences in BMD change and TBS change were seen between users and nonusers during follow-up (p<0.0001). Significant decreases in mean BMD and TBS (−0.36± 0.05% per year; −0.31±0.06% per year) were seen for non-users compared with baseline (p<0.001). A significant increase in mean BMD was seen for users compared with baseline (+1.86±0.0% per year, p<0.0018). TBS of users also increased compared with baseline (+0.20±0.08% per year, p<0.001), but more slowly than BMD. Conclusion: We observed a significant increase in spine BMD and a positive maintenance of bone micro-architecture from TBS with antiresorptive treatment, whereas the treatment naïve group lost both density and micro-architecture. TBS seems to be responsive to treatment and could be suitable for monitoring micro-architecture. This article is part of a Special Issue entitled ECTS 2011. Disclosure of interest: M.-A. Krieg: None declared, A. Goertzen: None declared, W. Leslie: None declared, D. Hans Consulting fees from Medimaps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The activity of the renin-angiotensin system is usually evaluated as plasma renin activity (PRA, ngAI/ml per h) but the reproducibility of this enzymatic assay is notoriously scarce. We compared the inter and intralaboratory reproducibilities of PRA with those of a new automated chemiluminescent assay, which allows the direct quantification of immunoreactive renin [chemiluminescent immunoreactive renin (CLIR), microU/ml]. METHODS: Aliquots from six pool plasmas of patients with very low to very high PRA levels were measured in 12 centres with both the enzymatic and the direct assays. The same methods were applied to three control plasma preparations with known renin content. RESULTS: In pool plasmas, mean PRA values ranged from 0.14 +/- 0.08 to 18.9 +/- 4.1 ngAI/ml per h, whereas those of CLIR ranged from 4.2 +/- 1.7 to 436 +/- 47 microU/ml. In control plasmas, mean values of PRA and of CLIR were always within the expected range. Overall, there was a significant correlation between the two methods (r = 0.73, P < 0.01). Similar correlations were found in plasmas subdivided in those with low, intermediate and high PRA. However, the coefficients of variation among laboratories found for PRA were always higher than those of CLIR, ranging from 59.4 to 17.1% for PRA, and from 41.0 to 10.7% for CLIR (P < 0.01). Also, the mean intralaboratory variability was higher for PRA than for CLIR, being respectively, 8.5 and 4.5% (P < 0.01). CONCLUSION: The measurement of renin with the chemiluminescent method is a reliable alternative to PRA, having the advantage of a superior inter and intralaboratory reproducibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evaluation of root traits may be facilitated if they are assessed on samples of the root system. The objective of this work was to determine the sample size of the root system in order to estimate root traits of common bean (Phaseolus vulgaris L.) cultivars by digital image analysis. One plant was grown per pot and harvested at pod setting, with 64 and 16 pots corresponding to two and four cultivars in the first and second experiments, respectively. Root samples were scanned up to the completeness of the root system and the root area and length were estimated. Scanning a root sample demanded 21 minutes, and scanning the entire root system demanded 4 hours and 53 minutes. In the first experiment, root area and length estimated with two samples showed, respectively, a correlation of 0.977 and 0.860, with these traits measured in the entire root. In the second experiment, the correlation was 0.889 and 0.915. The increase in the correlation with more than two samples was negligible. The two samples corresponded to 13.4% and 16.9% of total root mass (excluding taproot and nodules) in the first and second experiments. Taproot stands for a high proportion of root mass and must be deducted on root trait estimations. Samples with nearly 15% of total root mass produce reliable root trait estimates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When health status is an ordered response variable, Allison and Foster (2004)postulate that a distribution Q exhibits more inequality than a distribution P if Q is obtained from P via a sequence of median preserving spreads. This paper introduces a parametric family of inequality indices which are founded on the Allison and Foster ordering. [Authors]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traditionally, studies dealing with muscle shortening have concentrated on assessing its impact on conduction velocity, and to this end, electrodes have been located between the end-plate and tendon regions. Possible morphologic changes in surface motor unit potentials (MUPs) as a result of muscle shortening have not, as yet, been evaluated or characterized. Using a convolutional MUP model, we investigated the effects of muscle shortening on the shape, amplitude, and duration characteristics of MUPs for different electrode positions relative to the fibre-tendon junction and for different depths of the MU in the muscle (MU-to-electrode distance). It was found that the effects of muscle shortening on MUP morphology depended not only on whether the electrodes were between the end-plate and the tendon junction or beyond the tendon junction, but also on the specific distance to this junction. When the electrodes lie between the end-plate and tendon junction, it was found that (1) the muscle shortening effect is not important for superficial MUs, (2) the sensitivity of MUP amplitude to muscle shortening increases with MU-to-electrode distance, and (3) the amplitude of the MUP negative phase is not affected by muscle shortening. This study provides a basis for the interpretation of the changes in MUP characteristics in experiments where both physiological and geometrical aspects of the muscle are varied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Understanding the oxidative reactivity of nanoparticles (NPs; <100 nm) could substantially contribute to explaining their toxicity. We attempted to refine the use of 2′7-dichlorodihydrofluorescein (DCFH) to characterize NP generation of reactive oxygen species (ROS). Several fluorescent probes have been applied to testing oxidative reactivity, but despite DCFH being one of the most popular for the detection of ROS, when it has been applied to NPs there have been an unexplainably wide variability in results. Without a uniform methodology, validating even robust results is impossible. This study, therefore, identified sources of conflicting results and investigated ways of reducing occurrence of artificial results. Existing techniques were tested and combined (using their most desirable features) to form a more reliable method for the measurement of NP reactivity in aqueous dispersions. We also investigated suitable sample ranges necessary to determine generation of ROS. Specifically, ultrafiltration and time-resolved scan absorbance spectra were used to study possible optical interference when using high sample concentrations. Robust results were achieved at a 5 µM DCFH working solution with 0.5 unit/mL horseradish peroxidase (HRP) dissolved in ethanol. Sonication in DCFH-HRP working solution provided more stable data with a relatively clean background. Optimal particle concentration depends on the type of NP and in general was in the µg/mL range. Major reasons for previously reported conflicting results due to interference were different experimental approaches and NP sample concentrations. The protocol presented here could form the basis of a standardized method for applying DCFH to detect generation of ROS by NPs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the study is to present the application of a headspace-gas chromatography-mass spectrometry (HS-GC-MS) method for the determination of the carbon monoxide (CO) blood concentration and to compare it with carboxyhemoglobin (HbCO) saturation. In postmortem cases, the HbCO measured by spectrophotometry frequently leads to inaccurate results due to inadequate samples or analyses. The true role of CO intoxication in the death of a person could be misclassified. The estimation of HbCO from HS-GC-MS CO measurements provides helpful information by determining the total CO levels (CO linked to hemoglobin (HbCO) and CO dissociated from hemoglobin). The CO concentrations were converted in HbCO saturation levels to define cutoff blood CO values. CO limits were defined as less than 1 μmol/mL for living persons, less than 1.5 μmol/mL for dead persons without CO exposure, and greater than 3 μmol/mL for dead persons with clear CO poisoning.