949 resultados para screening of mechanical pulp
Resumo:
This paper intends to evaluate the capacity of producing concrete with a pre-established performance (in terms of mechanical strength) incorporating recycled concrete aggregates (RCA) from different sources. To this purpose, rejected products from the precasting industry and concrete produced in laboratory were used. The appraisal of the self-replication capacity was made for three strength ranges: 15-25 MPa, 35-45 MPa and 65-75 MPa. The mixes produced tried to replicate the strength of the source concrete (SC) of the RA. Only total, (100%) replacement of coarse natural aggregates (CNA) by coarse recycled concrete aggregates (CRCA) was tested. The results show that, both in mechanical and durability terms, there were no significant differences between aggregates from controlled sources and those from precast rejects for the highest levels of the target strength. Furthermore, the performance losses resulting from the RA's incorporation are substantially reduced when used medium or high strength SC's. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
This paper addresses the use of multidimensional scaling in the evaluation of controller performance. Several nonlinear systems are analyzed based on the closed loop time response under the action of a reference step input signal. Three alternative performance indices, based on the time response, Fourier analysis, and mutual information, are tested. The numerical experiments demonstrate the feasibility of the proposed methodology and motivate its extension for other performance measures and new classes of nonlinearities.
Resumo:
The behavior of mechanical manipulators with backlash is analyzed. In order to acquire and study the signals an experimental setup is implemented. The signal processing capabilities of the wavelets are used for de-noising the experimental signals and the energy of the obtained components is analyzed. To evaluate the backlash effect upon the robotic system, it is proposed an index based on the pseudo phase plane representation. Several tests are developed that demonstrate the coherence of the results.
Resumo:
The minimization of the power loss and the use of the biodegradable greases have attracting considerable attention. To compare the energetic performance of biodegradable lubricant greases, power loss tests were performed on a modified four-ball machine. A correlation between the grease formulation and rheology was established with its energetic performance
Resumo:
Glass fibre-reinforced plastics (GFRP), nowadays commonly used in the construction, transportation and automobile sectors, have been considered inherently difficult to recycle due to both: cross-linked nature of thermoset resins, which cannot be remolded, and complex composition of the composite itself, which includes glass fibres, matrix and different types of inorganic fillers. Presently, most of the GFRP waste is landfilled leading to negative environmental impacts and supplementary added costs. With an increasing awareness of environmental matters and the subsequent desire to save resources, recycling would convert an expensive waste disposal into a profitable reusable material. There are several methods to recycle GFR thermostable materials: (a) incineration, with partial energy recovery due to the heat generated during organic part combustion; (b) thermal and/or chemical recycling, such as solvolysis, pyrolisis and similar thermal decomposition processes, with glass fibre recovering; and (c) mechanical recycling or size reduction, in which the material is subjected to a milling process in order to obtain a specific grain size that makes the material suitable as reinforcement in new formulations. This last method has important advantages over the previous ones: there is no atmospheric pollution by gas emission, a much simpler equipment is required as compared with ovens necessary for thermal recycling processes, and does not require the use of chemical solvents with subsequent environmental impacts. In this study the effect of incorporation of recycled GFRP waste materials, obtained by means of milling processes, on mechanical behavior of polyester polymer mortars was assessed. For this purpose, different contents of recycled GFRP waste materials, with distinct size gradings, were incorporated into polyester polymer mortars as sand aggregates and filler replacements. The effect of GFRP waste treatment with silane coupling agent was also assessed. Design of experiments and data treatment were accomplish by means of factorial design and analysis of variance ANOVA. The use of factorial experiment design, instead of the one factor at-a-time method is efficient at allowing the evaluation of the effects and possible interactions of the different material factors involved. Experimental results were promising toward the recyclability of GFRP waste materials as polymer mortar aggregates, without significant loss of mechanical properties with regard to non-modified polymer mortars.
Resumo:
Resumo: Com base no conceito de implementação de intenções (Gollwitzer, 1993, 1999) e na teoria do contexto de resposta de Kirsch & Lynn (1997), o presente trabalho testou a eficácia de uma intervenção combinada de implementação de intenções com hipnose e sugestão pós-hipnótica na promoção da adesão a uma tarefa simples (avaliação do humor) e uma tarefa difícil (actividade física). Os participantes são estudantes universitários de uma universidade na Nova Jérsia, (N=124, Estudo 1, EUA) e em Lisboa (N=323, Estudo 2, Portugal). Em ambos os estudos os participantes foram seleccionados a partir de uma amostra mais vasta baseado num escrutínio da sua sugestibilidade hipnótica avaliada por meio da Escala de Grupo de Sugestibilidade Hipnótica de Waterloo-Stanford (WSGC): Forma C. O Estudo 1 usou um desenho factorial do tipo 2x2x3 (tipo de intenção formada x hipnose x nível de sugestionabilidade) e o Estudo 2 usou um desenho factorial do tipo 2 x 2x 2 x 4 (tipo de tarefa x tipo de intenção formada x hipnose x nível de sugestionabilidade). No Estudo 1 foi pedido aos participantes que corressem todos os dias e durante três semanas durante 5 minutos, que medissem a sua pulsação antes e depois da actividade física e que mandassem um e-mail ao experimentador, fornecendo assim uma medida comportamental e uma medida de auto-relato. Aos participantes no grupo de intenções de meta foi apenas pedido que corressem todos os dias. Aos participantes no grupo de implementação de intenções foi pedido que especificasses com exactidão quando e onde iriam correr e enviar o e-mail. Para além disso, cerca de metade dos participantes foram hipnotizados e receberam uma sugestão pós-hipnótica em que lhes foi sugerido que o pensamento de correr todos os dias lhes viria à mente sem esforço no momento apropriado. A outra metade dos participantes não recebeu qualquer sugestão hipnótica. No Estudo 2 foi seguido o mesmo procedimento, mas a cerca de metade dos participantes foi atribuída uma tarefa fácil (enviar um Adherence to health-related behaviors ix SMS com a avaliação diária do seu estado de humor naquele momento) e à outra metade da amostra foi atribuída a tarefa de exercício físico atrás descrita (tarefa difícil). Os resultados do estudo 1 mostraram uma interacção significativa entre o nível de sugestionabilidade dos participantes e a sugestão pós-hipnótica (p<.01) indicando que a administração da sugestão pós-hipnótica aumentou a adesão nos participantes muito sugestionáveis, mas baixou a adesão nos participantes pouco sugestionáveis. Não se encontraram diferenças entre os grupos que formaram intenções de meta e os que formaram implementação de intenções. No Estudo 2 os resultados indicaram que os participantes aderiram significativamente mais à tarefa fácil do que à tarefa difícil (p<.001). Os resultados não revelaram diferenças significativas entre as condições implementações de intenções, hipnose e as duas estratégias combinadas, indicando que a implementação de intenções não foi eficaz no aumento da adesão às duas tarefas propostas e não beneficiou da combinação com as sugestões pós-hipnóticas. A utilização da hipnose com sugestão pós-hipnótica significativamente reduziu a adesão a ambas as tarefas. Dado que não existiam instrumentos em Português destinados a avaliar a sugestionabilidade hipnótica, traduziu-se e adaptou-se para Português Escala de Grupo de sugestibilidade hipnótica de Waterloo-Stanford (WSGC): Forma C. A amostra Portuguesa (N=625) apresentou resultados semelhantes aos encontrados nas amostras de referência em termos do formato da distribuição dos padrões da pontuação e do índice de dificuldade dos itens. Contudo, a proporção de estudantes portugueses encontrada que pontuaram na zona superior de sugestionabilidade foi significativamente inferior à proporção de participantes na mesma zona encontrada nas amostras de referência. No sentido de lançar alguma luz sobre as razões para este resultado, inquiriu-se alguns dos participantes acerca das suas atitudes face à hipnose utilizando uma versão portuguesa da Escala de Valência de Atitudes e Crenças face à Hipnose e comparou-se com a opinião de Adherence to health-related behaviors xAbstract: On the basis of Gollwitzer’s (1993, 1999) implementation intentions’ concept, and Kirsch & Lynn’s (1997) response set theory, this dissertation tested the effectiveness of a combined intervention of implementation intentions with hypnosis with posthypnotic suggestions in enhancing adherence to a simple (mood report) and a difficult (physical activity) health-related task. Participants were enrolled in a university in New Jersey (N=124, Study 1, USA) and in two universities in Lisbon (N=323, Study 2, Portugal). In both studies participants were selected from a broader sample based on their suggestibility scores using the Waterloo-Stanford Group C (WSGC) scale of hypnotic susceptibility and then randomly assigned to the experimental groups. Study 1 used a 2x2x3 factorial design (instruction x hypnosis x level of suggestibility) and Study 2 used a 2 x 2x 2 x 4 factorial design (task x instructions x hypnosis x level of suggestibility). In Study 1 participants were asked to run in place for 5 minutes each day for a three-week period, to take their pulse rate before and after the activity, and to send a daily email report to the experimenter, thus providing both a self-report and a behavioral measure of adherence. Participants in the goal intention condition were simply asked to run in place and send the e-mail once a day. Those in the implementation intention condition were further asked to specify the exact place and time they would perform the physical activity and send the e-mail. In addition, half of the participants were given a post-hypnotic suggestion indicating that the thought of running in place would come to mind without effort at the appropriate moment. The other half did not receive a posthypnotic suggestion. Study 2 followed the same procedure, but additionally half of the participants were instructed to send a mood report by SMS (easy task) and half were assigned to the physical activity task described above (difficult task). Adherence to health-related behaviors vii Study 1 result’s showed a significant interaction between participant’s suggestibility level and posthypnotic suggestion (p<.01) indicating that posthypnotic suggestion enhanced adherence among highly suggestible participants, but lowered it among low suggestible individuals. No differences between the goal intention and the implementation intentions groups were found. In Study 2, participants adhered significantly more (p<.001) to the easy task than to the difficult task. Results did not revealed significant differences between the implementation intentions, hypnosis and the two conditions combined, indicating that implementation intentions was not enhanced by hypnosis with posthypnotic suggestion, neither was effective as single intervention in enhancing adherence to any of the tasks. Hypnosis with posthypnotic suggestion alone significantly reduced adherence to both tasks in comparison with participants that did not receive hypnosis. Since there were no instruments in Portuguese language to asses hypnotic suggestibility, the Waterloo-Stanford Group C (WSGC) scale of hypnotic susceptibility was translated and adapted to Portuguese and was used in the screening of a sample of college students from Lisbon (N=625). Results showed that the Portuguese sample has distribution shapes and difficulty patterns of hypnotic suggestibility scores similar to the reference samples, with the exception of the proportion of Portuguese students scoring in the high range of hypnotic suggestibility, that was found lower than the in reference samples. In order to shed some light on the reasons for this finding participant’s attitudes toward hypnosis were inquired using a Portuguese translation and adaptation of the Escala de Valencia de Actitudes y Creencias Hacia la Hipnosis, Versión Cliente, and compared with participants with no prior hypnosis experience (N=444). Significant differences were found between the two groups with participants without hypnosis experience scoring higher in factors indicating misconceptions and negative attitudes about hypnosis.
Resumo:
Mestrado em Engenharia Química - Ramo Otimização Energética na Indústria Química
Resumo:
A new serological test, the gelatin particle agglutination test (GPAT), was used for the serodiagnosis of schistosomiasis mansoni. This technique showed the sensitivity (90.6%) and specificity (97.8%) close to those of enzyme-linked immunosorbent assay. The GPAT can be easily and rapidly performed without specialized equipment, by using lyophilized antigen-coated gelatin particles. The test also seems to be useful for mass screening of Schistosoma infection in field conditions.
Resumo:
Data concerning HCV infection in Central Brazil are rare. Upon testing 2,350 voluntary blood donors from this region, we found anti-HCV prevalence rates of 2.2% by a second generation ELISA and 1.4% after confirmation by a line immunoassay. Antibodies against core, NS4, and NS5 antigens of HCV were detected in 81.8%, 72.7%, and 57.5%, respectively, of the positive samples in the line immunoassay. HCV viremia was present in 76.6% of the anti-HCV-positive blood donors. A relation was observed between PCR positivity and serum reactivity in recognizing different HCV antigens in the line immunoassay. The majority of the positive donors had history of previous parenteral exposure. While the combination of ALT>50 IU/l and anti-HBc positivity do not appear to be good surrogate markers for HCV infection, the use of both ALT anti-HCV tests is indicated in the screening of Brazilian blood donors.
Resumo:
Dissertation submitted to Faculdade de Ciências e Tecnologia - Universidade Nova de Lisboa in fulfilment of the requirements for the degree of Doctor of Philosophy (Biochemistry - Biotechnology)
Resumo:
The most frequent form of acquisition of Chagas' disease in endemic areas was the transmission through the feces of contaminated triatominae. However, special attention should be paid in urban areas to transmission by blood transfusion, justifying the compulsory screening of blood donors. Early investigations at blood banks in the town of Londrina, Brazil, demonstrated that the seroprevalence of anti-Trypanosoma cruzi antibodies among blood donors was approximately 7.0% in the fifties9,34. Further studies demonstrated pratically the same seroprevalence until the eighties4,32,41. In an attempt to obtain data about the real dimension of the seropositivity for anti-Trypasonoma cruzi antibodies in the region, the authors carried out a large-scale study on 45,774 serum samples from blood donors of the Hemocentro of Hospital Universitário Regional do Norte do Paraná (HURNP), Universidade Estadual de Londrina. The immunological tests were done at the Division of Clinical Immunology of HURNP from May 1990 to December 1994. The serum samples were studied by the indirect hemagglutination assay (IHA, using kits commercially obtained from EBRAM) and by indirect immunofluorescence (IFI, using kits from LIO SERUM) with anti-human IgG conjugate (LABORCLIN). The results demonstrated that 643 serum samples were positive in both assay corresponding to a seroprevalence of 1.4%, i.e., a significant decrease in anti-Trypanosoma cruzi antibodies in the region in comparison with the previously mentioned rates. Data correlating sex and age of seropositive blood donors are presented, as well as the possible factors that may have contributed to the results observed.
Resumo:
Nesta dissertação pretendeu-se estudar a viabilidade do uso de eletrodiálise com membranas bipolares (BM) na recuperação de ácido clorídrico e de hidróxido de sódio a partir de um efluente industrial que contém 1.4 mol/L de cloreto de sódio. Estas membranas mostraram ser uma ferramenta eficiente para a produção de ácidos e bases a partir do respetivo sal. Foi feita uma seleção de diferentes membranas bipolares (Neosepta, Fumatech e PCA) e aniónicas (PC-SA e PC-ACID 60) na tentativa de encontrar a combinação mais adequada para o tratamento do efluente. Dependendo do critério, o melhor arranjo de membranas é o uso de PC-ACID 60 (membrana aniónica), PC-SK (membrana catiónica) e membranas bipolares do tipo Neosepta para maior pureza dos produtos; membranas bipolares Fumatech para maior eficiência de dessalinização e membranas bipolares PCA para um maior grau de dessalinização. Tecnologicamente foi possível obter uma dessalinização de 99.8% em quatro horas de funcionamento em modo batch com recirculação de todas as correntes. Independentemente da combinação usada é recomendável que o processo seja parado quando a densidade de corrente deixa de ser máxima, 781 A/m2. Assim é possível evitar o aumento de impurezas nos produtos, contra difusão, descida instantânea do pH e uma dessalinização pouco eficiente. A nível piloto o principal fornecedor de membranas e unidade de tratamento “stack” é a marca alemã PCA. Sendo assim realizaram-se ensaios de repetibilidade, contra difusão, avaliação económica e upscaling utilizando as membranas bipolares PCA. A nível económico estudou-se o uso de dois tipos de unidades de tratamento; EDQ 380 e EDQ 1600, para diferentes níveis de dessalinização (50, 75 e 80%). Tendo em conta a otimização económica, é recomendável uma dessalinização máxima de 80%, uma vez que a eficiência de processo a este ponto é de 40%. A aplicação do método com a unidade EDQ 1600 para uma dessalinização de 50% é a mais vantajosa economicamente, com custos de 16 €/m3 de efluente tratado ou 0,78 €/kg Cl- removido. O número de unidades necessárias é 4 posicionados em série.
Resumo:
In the present study ELISA was standardized for the diagnosis of swine cysticercosis based on necropsy parameters and confirmed positive and negative control sera. Serum samples from pigs with other infections were also assayed to determine possible cross-reactions. Four antigens were assayed: from Taenia crassiceps vesicular fluid (VF-Tcra) and crude larvae extract (T-Tcra), and from Taenia solium extracts of scolex (S-Ts) and of larvae (T-Ts). A checkerboard evaluation of antigen, serum and conjugate dilutions, as well as the use of Tween-20 and skim cow milk in wash and blocking solution had a marked effect on improving ELISA performance. All the antigens showed a good performance, but VF-Tcra was the best, with 96.0% and 80.0% sensitivities for cut-offs respectively at 2sd and 3sd, and corresponding specificities of 97.5% and 100.0%. Cross-reactivity was observed only with hydatidosis and ascaridiosis. In view of the high performance observed, the ELISA test should be recommended for the diagnosis of cysticercosis in suspected swine in slaughterhouses and for the screening of cysticercosis in swine production. These results will support integrated measures of cysticercosis control throughout the chain of swine production, effectively contributing to public health.
Resumo:
Simple and rapid latex-based diagnostic tests have been used for detecting specific antigens or antibodies in several diseases. In this article, we present the preliminary results obtained with a latex agglutination test (LAT) for diagnosing neurocysticercosis by detection of antibodies in CSF. A total of 43 CSF samples were assayed by the LAT: 19 CSF samples from patients with neurocysticercosis and 24 CSF samples from patients with other neurologic disorders (neurosyphilis, n = 8; neurotoxoplasmosis, n = 3; viral meningitis, n = 4, chronic headache, n = 9). The LAT exhibited 89.5% sensitivity and 75% specificity. The use of LAT seems to be an additional approach for the screening of neurocysticercosis with advantage of simplicity and rapidity. Further studies could be performed using purified antigens and serum samples.
Resumo:
This study evaluated the whole blood immunochromatographic card test (ICT card test) in a survey performed in Northeastern Brazil. 625 people were examined by the thick blood film (TBF) and ICT card test. Residents of a non-endemic area were also tested by the whole blood card test and Og4C3. The sensitivity of the ICT card test was 94.7% overall, but lower in females than males, based on the reasonable assumption that TBF is 100% specific. However, since TBF and other methods have unknown sensitivity, the true specificity of the card test is unknown. Nevertheless, it is possible to estimate upper and lower limits for the specificity, and relate it to the prevalence of the disease. In the endemic area, the possible range of the specificity was from 72.4% to 100%. 29.6% of the card tests performed in the non-endemic area exhibited faint lines that were interpreted as positives. Characteristics of the method including high sensitivity, promptness and simplicity justify its use for screening of filariasis. However, detailed information about the correct interpretation in case of extremely faint lines is essential. Further studies designed to consider problems arising from imperfect standards are necessary, as is a sounder diagnostic definition for the card test.