989 resultados para resonance frequency


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diagnosis of idiopathic Parkinson's disease (IPD) is entirely clinical. The fact that neuronal damage begins 5-10 years before occurrence of sub-clinical signs, underlines the importance of preclinical diagnosis. A new approach for in-vivo pathophysiological assessment of IPD-related neurodegeneration was implemented based on recently developed neuroimaging methods. It is based on non- invasive magnetic resonance data sensitive to brain tissue property changes that precede macroscopic atrophy in the early stages of IPD. This research aims to determine the brain tissue property changes induced by neurodegeneration that can be linked to clinical phenotypes which will allow us to create a predictive model for early diagnosis in IPD. We hypothesized that the degree of disease progression in IPD patients will have a differential and specific impact on brain tissue properties used to create a predictive model of motor and non-motor impairment in IPD. We studied the potential of in-vivo quantitative imaging sensitive to neurodegeneration- related brain tissue characteristics to detect changes in patients with IPD. We carried out methodological work within the well established SPM8 framework to estimate the sensitivity of tissue probability maps for automated tissue classification for detection of early IPD. We performed whole-brain multi parameter mapping at high resolution followed by voxel-based morphometric (VBM) analysis and voxel-based quantification (VBQ) comparing healthy subjects to IPD patients. We found a trend demonstrating non-significant tissue property changes in the olfactory bulb area using the MT and R1 parameter with p<0.001. Comparing to the IPD patients, the healthy group presented a bilateral higher MT and R1 intensity in this specific functional region. These results did not correlate with age, severity or duration of disease. We failed to demonstrate any changes with the R2* parameter. We interpreted our findings as demyelination of the olfactory tract, which is clinically represented as anosmia. However, the lack of correlation with duration or severity complicates its implications in the creation of a predictive model of impairment in IPD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine the usefulness of computed tomography (CT), magnetic resonance imaging (MRI), and Doppler ultrasonography (US) in providing specific images of gouty tophi. METHODS: Four male patients with chronic gout with tophi affecting the knee joints (three cases) or the olecranon processes of the elbows (one case) were assessed. Crystallographic analyses of the synovial fluid or tissue aspirates of the areas of interest were made with polarising light microscopy, alizarin red staining, and x ray diffraction. CT was performed with a GE scanner, MR imaging was obtained with a 1.5 T Magneton (Siemens), and ultrasonography with colour Doppler was carried out by standard technique. RESULTS: Crystallographic analyses showed monosodium urate (MSU) crystals in the specimens of the four patients; hydroxyapatite and calcium pyrophosphate dihydrate (CPPD) crystals were not found. A diffuse soft tissue thickening was seen on plain radiographs but no calcifications or ossifications of the tophi. CT disclosed lesions containing round and oval opacities, with a mean density of about 160 Hounsfield units (HU). With MRI, lesions were of low to intermediate signal intensity on T(1) and T(2) weighting. After contrast injection in two cases, enhancement of the tophus was seen in one. Colour Doppler US showed the tophi to be hypoechogenic with peripheral increase of the blood flow in three cases. CONCLUSION: The MR and colour Doppler US images showed the tophi as masses surrounded by a hypervascular area, which cannot be considered as specific for gout. But on CT images, masses of about 160 HU density were clearly seen, which correspond to MSU crystal deposits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compared the extent and origin of muscle fatigue induced by short-pulse-low-frequency [conventional (CONV)] and wide-pulse-high-frequency (WPHF) neuromuscular electrical stimulation. We expected CONV contractions to mainly originate from depolarization of axonal terminal branches (spatially determined muscle fiber recruitment) and WPHF contractions to be partly produced via a central pathway (motor unit recruitment according to size principle). Greater neuromuscular fatigue was, therefore, expected following CONV compared with WPHF. Fourteen healthy subjects underwent 20 WPHF (1 ms-100 Hz) and CONV (50 μs-25 Hz) evoked isometric triceps surae contractions (work/rest periods 20:40 s) at an initial target of 10% of maximal voluntary contraction (MVC) force. Force-time integral of the 20 evoked contractions (FTI) was used as main index of muscle fatigue; MVC force loss was also quantified. Central and peripheral fatigue were assessed by voluntary activation level and paired stimulation amplitudes, respectively. FTI in WPHF was significantly lower than in CONV (21,717 ± 11,541 vs. 37,958 ± 9,898 N·s P<0,001). The reductions in MVC force (WPHF: -7.0 ± 2.7%; CONV: -6.2 ± 2.5%; P < 0.01) and paired stimulation amplitude (WPHF: -8.0 ± 4.0%; CONV: -7.4 ± 6.1%; P < 0.001) were similar between conditions, whereas no change was observed for voluntary activation level (P > 0.05). Overall, our results showed a different motor unit recruitment pattern between the two neuromuscular electrical stimulation modalities with a lower FTI indicating greater muscle fatigue for WPHF, possibly limiting the presumed benefits for rehabilitation programs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Although CD4 cell count monitoring is used to decide when to start antiretroviral therapy in patients with HIV-1 infection, there are no evidence-based recommendations regarding its optimal frequency. It is common practice to monitor every 3 to 6 months, often coupled with viral load monitoring. We developed rules to guide frequency of CD4 cell count monitoring in HIV infection before starting antiretroviral therapy, which we validated retrospectively in patients from the Swiss HIV Cohort Study.Methodology/Principal Findings: We built up two prediction rules ("Snap-shot rule" for a single sample and "Track-shot rule" for multiple determinations) based on a systematic review of published longitudinal analyses of CD4 cell count trajectories. We applied the rules in 2608 untreated patients to classify their 18 061 CD4 counts as either justifiable or superfluous, according to their prior >= 5% or < 5% chance of meeting predetermined thresholds for starting treatment. The percentage of measurements that both rules falsely deemed superfluous never exceeded 5%. Superfluous CD4 determinations represented 4%, 11%, and 39% of all actual determinations for treatment thresholds of 500, 350, and 200x10(6)/L, respectively. The Track-shot rule was only marginally superior to the Snap-shot rule. Both rules lose usefulness for CD4 counts coming near to treatment threshold.Conclusions/Significance: Frequent CD4 count monitoring of patients with CD4 counts well above the threshold for initiating therapy is unlikely to identify patients who require therapy. It appears sufficient to measure CD4 cell count 1 year after a count > 650 for a threshold of 200, > 900 for 350, or > 1150 for 500x10(6)/L, respectively. When CD4 counts fall below these limits, increased monitoring frequency becomes advisable. These rules offer guidance for efficient CD4 monitoring, particularly in resource-limited settings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Conventional x-ray angiography frequently underestimates the true burden of atherosclerosis. Although intravascular ultrasound allows for imaging of coronary plaque, this invasive technique is inappropriate for screening or serial examinations. We therefore sought to develop a noninvasive free-breathing MR technique for coronary vessel wall imaging. We hypothesized that such an approach would allow for in vivo imaging of coronary atherosclerosis. METHODS AND RESULTS: Ten subjects, including 5 healthy adult volunteers (aged 35+/-17 years, range 19 to 56 years) and 5 patients (aged 60+/-4 years, range 56 to 66 years) with x-ray-confirmed coronary artery disease (CAD), were studied with a T2-weighted, dual-inversion, fast spin-echo MR sequence. Multiple adjacent 5-mm cross-sectional images of the proximal right coronary artery were obtained with an in-plane resolution of 0.5x1.0 mm. A right hemidiaphragmatic navigator was used to facilitate free-breathing MR acquisition. Coronary vessel wall images were readily acquired in all subjects. Both coronary vessel wall thickness (1.5+/-0.2 versus 1.0+/-0.2 mm) and wall area (21.2+/-3.1 versus 13.7+/-4.2 mm(2)) were greater in patients with CAD (both P:<0.02 versus healthy adults). CONCLUSIONS: In vivo free-breathing coronary vessel wall and plaque imaging with MR has been successfully implemented in humans. Coronary wall thickness and wall area were significantly greater in patients with angiographic CAD. The presented technique may have potential applications in patients with known or suspected atherosclerotic CAD or for serial evaluation after pharmacological intervention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rockfall hazard zoning is usually achieved using a qualitative estimate of hazard, and not an absolute scale. In Switzerland, danger maps, which correspond to a hazard zoning depending on the intensity of the considered phenomenon (e.g. kinetic energy for rockfalls), are replacing hazard maps. Basically, the danger grows with the mean frequency and with the intensity of the rockfall. This principle based on intensity thresholds may also be applied to other intensity threshold values than those used in Switzerland for rockfall hazard zoning method, i.e. danger mapping. In this paper, we explore the effect of slope geometry and rockfall frequency on the rockfall hazard zoning. First, the transition from 2D zoning to 3D zoning based on rockfall trajectory simulation is examined; then, its dependency on slope geometry is emphasized. The spatial extent of hazard zones is examined, showing that limits may vary widely depending on the rockfall frequency. This approach is especially dedicated to highly populated regions, because the hazard zoning has to be very fine in order to delineate the greatest possible territory containing acceptable risks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the utility of inversion recovery with on-resonant water suppression (IRON) in combination with injection of the long-circulating monocrystalline iron oxide nanoparticle (MION)-47 for contrast material-enhanced magnetic resonance (MR) angiography. MATERIALS AND METhods: Experiments were approved by the institutional animal care committee. Eleven rabbits were imaged at baseline before injection of a contrast agent and then serially 5-30 minutes, 2 hours, 1 day, and 3 days after a single intravenous bolus injection of 80 micromol of MION-47 per kilogram of body weight (n = 6) or 250 micromol/kg MION-47 (n = 5). Conventional T1-weighted MR angiography and IRON MR angiography were performed on a clinical 3.0-T imager. Signal-to-noise and contrast-to-noise ratios were measured in the aorta of rabbits in vivo. Venous blood was obtained from the rabbits before and after MION-47 injection for use in phantom studies. RESULTS: In vitro blood that contained MION-47 appeared signal attenuated on T1-weighted angiograms, while characteristic signal-enhanced dipolar fields were observed on IRON angiograms. In vivo, the vessel lumen was signal attenuated on T1-weighted MR angiograms after MION-47 injection, while IRON supported high intravascular contrast by simultaneously providing positive signal within the vessels and suppressing background tissue (mean contrast-to-noise ratio, 61.9 +/- 12.4 [standard deviation] after injection vs 1.1 +/- 0.4 at baseline, P < .001). Contrast-to-noise ratio was higher on IRON MR angiograms than on conventional T1-weighted MR angiograms (9.0 +/- 2.5, P < .001 vs IRON MR angiography) and persisted up to 24 hours after MION-47 injection (76.2 +/- 15.9, P < .001 vs baseline). CONCLUSION: IRON MR angiography in conjunction with superparamagnetic nanoparticle administration provides high intravascular contrast over a long time and without the need for image subtraction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: As the magnetic susceptibility induced frequency shift increases linearly with magnetic field strength, the present work evaluates manganese as a phase imaging contrast agent and investigates the dose dependence of brain enhancement in comparison to T1 -weighted imaging after intravenous administration of MnCl2 . METHODS: Experiments were carried out on 12 Sprague-Dawley rats. MnCl2 was infused intravenously with the following doses: 25, 75, 125 mg/kg (n=4). Phase, T1 -weighted images and T1 maps were acquired before and 24h post MnCl2 administration at 14.1 Tesla. RESULTS: Manganese enhancement was manifested in phase imaging by an increase in frequency shift differences between regions rich in calcium gated channels and other tissues, together with local increase in signal to noise ratio (from the T1 reduction). Such contrast improvement allowed a better visualization of brain cytoarchitecture. The measured T1 decrease observed across different manganese doses and in different brain regions were consistent with the increase in the contrast to noise ratio (CNR) measured by both T1 -weighted and phase imaging, with the strongest variations being observed in the dentate gyrus and olfactory bulb. CONCLUSION: Overall from its high sensitivity to manganese combined with excellent CNR, phase imaging is a promising alternative imaging protocol to assess manganese enhanced MRI at ultra high field. Magn Reson Med 72:1246-1256, 2014. © 2013 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A total of 357 house mice (Mus domesticus) from 83 localities uniformly distributed throughout Switzerland were screened for the presence of a homogenously staining region (HSR) on chromosome 1. Altogether 47 mice from 11 localities were HSR/+ or HSR/HSR. One sample of 11 individuals all had an HSR/HSR karyotype. Almost all mice with the variant were collected from the Rhone valley (HSR frequency: 61%) and Val Bregaglia (HSR frequency: 81%). For samples from most of the area of Switzerland, the HSR was absent. There was no strong association between the geographic distribution of the HSR and the areas of occurrence of metacentrics. However, at Chiggiogna the HSR was found on Rb (1.3). Possible explanations for the HSR polymorphism are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report feasibility and potential benefits of high-frequency jet ventilation (HFJV) in tumor ablations techniques in liver, kidney, and lung lesions. METHODS: This prospective study included 51 patients (14 women, mean age 66 years) bearing 66 tumors (56 hepatic, 5 pulmonary, 5 renal tumors) with a median size of 16 ± 8.7 mm, referred for tumor ablation in an intention-to-treat fashion before preoperative anesthesiology visit. Cancellation and complications of HFJV were prospectively recorded. Anesthesia and procedure duration, as well as mean CO2 capnea, were recorded. When computed tomography guidance was used, 3D spacial coordinates of an anatomical target <2 mm in diameter on 8 slabs of 4 slices of 3.75-mm slice thickness were registered. RESULTS: HFJV was used in 41 of 51 patients. Of the ten patients who were not candidate for HFJV, two patients had contraindication to HFJV (severe COPD), three had lesions invisible under HFJV requiring deep inspiration apnea for tumor targeting, and five patients could not have HFJV because of unavailability of a trained anesthetic team. No specific complication or hypercapnia related to HFJV were observed despite a mean anesthetic duration of 2 h and ventilation performed in procubitus (n = 4) or lateral decubitus (n = 6). Measured internal target movement was 0.3 mm in x- and y-axis and below the slice thickness of 3.75 mm in the z-axis in 11 patients. CONCLUSIONS: HFJV is feasible in 80 % of patients allowing for near immobility of internal organs during liver, kidney, and lung tumor ablation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to investigate the impact of navigator timing on image quality in navigator-gated and real-time motion-corrected, free-breathing, three-dimensional (3D) coronary MR angiography (MRA) with submillimeter spatial image resolution. Both phantom and in vivo investigations were performed. 3D coronary MRA with real-time navigator technology was applied using variable navigator time delays (time delay between the navigator and imaging sequences) and varying spatial resolutions. Quantitative objective and subjective image quality parameters were assessed. For high-resolution imaging, reduced image quality was found as a function of increasing navigator time delay. Lower spatial resolution coronary MRA showed only minor sensitivity to navigator timing. These findings were consistent among volunteers and phantom experiments. In conclusion, for submillimeter navigator-gated and real-time motion-corrected 3D coronary MRA, shortening the time delay between the navigator and the imaging portion of the sequence becomes increasingly important for improved spatial resolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Medical treatment of inflammatory bowel disease (IBD) is becoming more and more complex, as several classes of immuno-modulating drugs (IMD) are often used simultaneously. Thus, the probability of adverse effects is greatly increased. Most studies reporting on adverse effects focus on single therapy, and studies providing a global survey of side effects for multiple treatments are lacking. Aim: To assess the type and frequency of adverse events in IBD patients treated with single and multiple IMD therapy. Methods: Analysis of data from the Swiss IBD Cohort Study (SIBDCS) that collects data on a large sample of IBD patients from hospitals and private practices across Switzerland. The following IMD categories were analyzed: 5-ASA, azathioprine (Aza), 6-mercaptopurine (6-MP), methotrexate (MTX), anti-TNF (infliximab, adalimumab, certolizumab-pegol), cyclosporine, tacrolimus, and steroids. The following side effects were assessed: hepatitis, pancreatitis, leucopenia, thrombopenia, nephritis, allergic reaction, pneumonitis, infections (including tuberculosis), osteoporosis, abdominal pain/diarrhea (unrelated to IBD activity), cataract, diabetes, exanthema, hirsutism, lupus-like syndrome, myalgias, depression/psychosis, tumor development. Results: A total of 1,961 patients were analyzed (977 [50%] female, mean age 42.1 ± 14.4 years): 1,119 with Crohn's disease (CD), 800 with ulcerative colitis (UC), and 42 with indeterminate colitis (IC). Three-hundred eighteen (16.2%) patients were not treated with any of the above-mentioned medications, while 650 (33.2%), 569 (29%) and 424 (21.6%) patients had one-, two-, and three- or more- IMD therapy, respectively. Of the 1,643 patients treated with IMD, 535 (32.6%) patients reported at least one side effect. We found a significant correlation between the number of drugs used by a patient and the frequency of side effects (17.4% side effects for one drug, 29% for 2 drugs, and 60.6% for three or more drugs, p < 0.001). The frequency of side effects for the different IMD classes were as follows: 5-ASA (n = 980 treated patients) 10.8%, Aza/6-MP (n = 636) 51.9% (pancreatitis in 57 = 9%, hepatitis in 17 = 2.7% of treated patients), MTX (n = 146) 42.5% (hepatitis in 4 = 2.7% of treated patients), anti-TNF (n = 255) 23.1%, cyclosporine (n = 49) 10.2%, tacrolimus (n = 5) 20%, steroids (systemic or topical, n = 1,150) 9.6%. Conclusion: IBD treatment is associated with a significant number of side effects. A direct correlation between the number of IMD used simultaneously and the frequency of side effects was observed. The results of this study indicate that treating physicians should be vigilant for the occurrence of side effects in IBD patients under single and/or multiple drug therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a novel compressed sensing technique to accelerate the magnetic resonance imaging (MRI) acquisition process. The method, coined spread spectrum MRI or simply s(2)MRI, consists of premodulating the signal of interest by a linear chirp before random k-space under-sampling, and then reconstructing the signal with nonlinear algorithms that promote sparsity. The effectiveness of the procedure is theoretically underpinned by the optimization of the coherence between the sparsity and sensing bases. The proposed technique is thoroughly studied by means of numerical simulations, as well as phantom and in vivo experiments on a 7T scanner. Our results suggest that s(2)MRI performs better than state-of-the-art variable density k-space under-sampling approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acute myocarditis was until recently one of the most difficult diagnoses in cardiology. The spectrum of signs and symptoms is very wide, the usual non-invasive tests lack specificity and the myocardial biopsy is only performed in a minority of cases to confirm the diagnosis. Due to its unique ability to directly image myocardial necrosis, fibrosis and oedema, cardiac magnetic resonance (CMR) is now considered the primary tool for noninvasive assessment of patients with suspected myocarditis. CMR is also useful for monitoring disease activity under treatment. Myocarditis has been associated with the development of dilated cardiomyopathy; CMR could play a role in the follow-up of such cases to detect the progression toward a dilatative phenotype. Precise mapping of myocardial lesions with cardiac MRI is invaluable to guide myocardial biopsy and increase its diagnostic yield by improving sensitivity.