969 resultados para programmable valves
Resumo:
Efficient image blurring techniques based on the pyramid algorithm can be implemented on modern graphics hardware; thus, image blurring with arbitrary blur width is possible in real time even for large images. However, pyramidal blurring methods do not achieve the image quality provided by convolution filters; in particular, the shape of the corresponding filter kernel varies locally, which potentially results in objectionable rendering artifacts. In this work, a new analysis filter is designed that significantly reduces this variation for a particular pyramidal blurring technique. Moreover, the pyramidal blur algorithm is generalized to allow for a continuous variation of the blur width. Furthermore, an efficient implementation for programmable graphics hardware is presented. The proposed method is named “quasi-convolution pyramidal blurring” since the resulting effect is very close to image blurring based on a convolution filter for many applications.
Resumo:
Werkzeugbauer stellen anspruchsvolle Spritzgießwerkzeuge als Einzelanfertigung oder in kleiner Stückzahl her. Dabei unterliegen sie einem hohen Zeit- und Kostendruck durch die Forderung der Kunden nach einer kurzen Time-to-Market und der Konkurrenz aus Niedriglohnländern. Eine Innovation des Werkzeugbaus zur Reduzierung von Zeit und Kosten ist die Integration von zusätzlichen Funktionen in bestehende Komponenten. Am Institut für Laser- und Anlagensystemtechnik der TU Hamburg-Harburg wurde in Zusammenarbeit mit Werkzeugbau Siegfried Hofmann und Concept Laser ein Druckluftauswerfersystem für Spritzgießwerkzeuge entwickelt. Dieses System kann klassische Auswerferstifte vollständig ersetzen. Die Integration von Druckluftauswerfern in laseradditiv gefertigte Werkzeugeinsätze mit konturnaher Kühlung erfolgt kostenneutral, da sich die Fertigungszeit des Einsatzes durch das zusätzliche System nicht verlängert und eine Druckluftsteuerung bereits in Spritzgießmaschinen vorhanden ist. Zusätzlich entfällt durch das Druckluftauswerfersystem das komplette mechanische Auswerferpaket. Durch diese Einsparungen reduzieren sich Zeit und Kosten für das Werkzeug.
Resumo:
Replacement intervals of implantable medical devices are commonly dictated by battery life. Therefore, intracorporeal energy harvesting has the potential to reduce the number of surgical interventions by extending the life cycle of active devices. Given the accumulated experience with intravascular devices such as stents, heart valves, and cardiac assist devices, the idea to harvest a small fraction of the hydraulic energy available in the cardiovascular circulation is revisited. The aim of this article is to explore the technical feasibility of harvesting 1 mW electric power using a miniature hydrodynamic turbine powered by about 1% of the cardiac output flow in a peripheral artery. To this end, numerical modelling of the fluid mechanics and experimental verification of the overall performance of a 1:1 scale friction turbine are performed in vitro. The numerical flow model is validated for a range of turbine configurations and flow conditions (up to 250 mL/min) in terms of hydromechanic efficiency; up to 15% could be achieved with the nonoptimized configurations of the study. Although this article does not entail the clinical feasibility of intravascular turbines in terms of hemocompatibility and impact on the circulatory system, the numerical model does provide first estimates of the mechanical shear forces relevant to blood trauma and platelet activation. It is concluded that the time-integrated shear stress exposure is significantly lower than in cardiac assist devices due to lower flow velocities and predominantly laminar flow.
Resumo:
Temperature plays a critical role in determining the biology of ectotherms. Many animals have evolved mechanisms that allow them to compensate biological rates, i.e. adjust biological rates to overcome thermodynamic effects. For low energy-organisms, such as bivalves, the costs of thermal compensation may be greater than the benefits, and thus prohibitive. To examine this, two experiments were designed to explore thermal compensation in Unio tumidus. Experiment 1 examined seasonal changes in behaviour in U. tumidus throughout a year. Temperature had a clear effect on burrowing rate with no evidence of compensation. Valve closure duration and frequency were also strongly affected by seasonal temperature change, but there was slight evidence of partial compensation. Experiment 2 examined oxygen consumption during burrowing, immediately following valve opening and at rest in summer (24 °C), autumn (14 °C), winter (4 °C), and spring (14 °C) acclimatized U. tumidus. Again, there was little evidence of burrowing rate compensation, but some evidence of partial compensation of valve closure duration and frequency. None of the oxygen compensation rates showed any evidence of thermal compensation. Thus, in general, there was only very limited evidence of thermal compensation of behaviour and no evidence of thermal compensation of oxygen compensation rates. Based upon this evidence, we argue that there is no evolutionary pressure for these bivalves to compensate these biological rates. Any pressure may be to maintain or even lower oxygen consumption as their only defence against predation is to close their valves and wait. An increase in oxygen consumption will be detrimental in this regard so the cost of thermal compensation may outweigh the benefits.
Resumo:
Seed production, seed dispersal, and seedling recruitment are integral to forest dynamics, especially in masting species. Often these are studied separately, yet scarcely ever for species with ballistic dispersal even though this mode of dispersal is common in legume trees of tropical African rain forests. Here, we studied two dominant main-canopy tree species, Microberlinia bisulcata and Tetraberlinia bifoliolata (Caesalpinioideae), in 25 ha of primary rain forest at Korup, Cameroon, during two successive masting events (2007/2010). In the vicinity of c. 100 and 130 trees of each species, 476/580 traps caught dispersed seeds and beneath their crowns c. 57,000 pod valves per species were inspected to estimate tree-level fecundity. Seed production of trees increased non-linearly and asymptotically with increasing stem diameters. It was unequal within the two species’ populations, and differed strongly between years to foster both spatial and temporal patchiness in seed rain. The M. bisulcata trees could begin seeding at 42–44 cm diameter: at a much larger size than could T. bifoliolata (25 cm). Nevertheless, per capita life-time reproductive capacity was c. five times greater in M. bisulcata than T. bifoliolata owing to former’s larger adult stature, lower mortality rate (despite a shorter life-time) and smaller seed mass. The two species displayed strong differences in their dispersal capabilities. Inverse modelling (IM) revealed that dispersal of M. bisulcata was best described by a lognormal kernel. Most seeds landed at 10–15 m from stems, with 1% of them going beyond 80 m (<100 m). The direct estimates of fecundity significantly improved the models fitted. The lognormal also described well the seedling recruitment distribution of this species in 121 ground plots. By contrast, the lower intensity of masting and more limited dispersal of the heavier-seeded T. bifoliolata prevented reliable IM. For this species, seed density as function of distance to traps suggested a maximum dispersal distance of 40–50 m, and a correspondingly more aggregated seedling recruitment pattern ensued than for M. bisulcata. From this integrated field study, we conclude that the reproductive traits of M. bisulcata give it a considerable advantage over T. bifoliolata by better dispersing more seeds per capita to reach more suitable establishment sites, and combined with other key traits they explain its local dominance in the forest. Understanding the linkages between size at onset of maturity, individual fecundity, and dispersal capability can better inform the life-history strategies, and hence management, of co-occurring tree species in tropical forests.
Resumo:
An exponential increase in the use of transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis has been witnessed over the recent years. The current article reviews different areas of uncertainty related to patient selection. The use and limitations of risk scores are addressed, followed by an extensive discussion on the value of three-dimensional imaging for prosthesis sizing and the assessment of complex valve anatomy such as degenerated bicuspid valves. The uncertainty about valvular stenosis severity in patients with a mismatch between the transvalvular gradient and the aortic valve area, and how integrated use of echocardiography and computed tomographic imaging may help, is also addressed. Finally, patients referred for TAVI may have concomitant mitral regurgitation and/or coronary artery disease and the management of these patients is discussed.
Resumo:
Abstract: The third-generation bovine pericardium Freedom SOLO (FS) stentless valve emerged in 2004 as a modified version of the Pericarbon Freedom stentless valve and as a very attractive alternative to stented bioprostheses. The design, choice of tissue, and anticalcification treatment fulfill most, if not all, requirements for an ideal valve substitute. The FS combines the single-suture, subcoronary implantation technique with the latest-generation bovine pericardial tissue and novel anticalcification treatment. The design allows imitation of the native healthy valve through unrestricted adaption to the patient's anatomy, reproducing a normal valve/root complex. However, despite hemodynamic performance superior to stented valves, we are approaching a critical observation period as superior durability, freedom from structural valve deterioration, and nonstructural failure has not been proven as expected. However, optimal performance and freedom from structural valve deterioration depend on correct sizing and perfect symmetric implantation, to ensure low leaflet stress. Any malpositioning can lead to tissue fatigue over time. Furthermore, the potential for better outcomes depends on optimal patient selection and observance of the limitations for the use of stentless valves, particularly for the FS. Clearly, stentless valve implantation techniques are less reproducible and standardized, and require surgeon-dependent experience and skill. Regardless of whether or not stentless valve durability surpasses third-generation stented bioprostheses, they will continue to play a role in the surgical repertoire. This review intends to help practitioners avoid pitfalls, observe limitations, and improve patient selection for optimal long-term outcome with the attractive FS stentless valve.
Resumo:
BACKGROUND The Perceval (Sorin Group, Milan, Italy) is a self-anchoring sutureless aortic valve prosthesis. We report the short- to midterm results of combined aortic valve replacement (AVR) with concomitant procedures in elderly patients undergoing operation as part of 3 consecutive prospective multicenter European studies. METHODS From April 2007 to February 2013, 243 patients (mean age, 79.7 ± 5.1 years; female patients, 61%; median EuroSCORE, 9%) underwent AVR with concomitant procedures. The concomitant procedures were coronary artery bypass grafting (CABG) (182 cases), septal myectomy (21 cases), CABG + other procedures (18 cases), and 22 other procedures. Primary and secondary end points included implant feasibility and safety (for mortality and morbidity) and efficacy (New York Heart Association [NYHA] class improvement and hemodynamic results) of the prosthesis at the different follow-up periods. Data were expressed as mean ± standard deviation. Kaplan-Meier analysis was performed for survival analysis. RESULTS Mean aortic cross-clamp and extracorporeal circulation (ECC) times were 50.7 ± 22.8 minutes and 78.9 ± 32.3 minutes, respectively. Thirty-day mortality was 2.1%. Mean postoperative gradient and effective orifice area were 10.1 ± 4.7 mm Hg and 1.5 ± 0.4 cm(2) and 8.9 ± 5.6 mm Hg and 1.6 ± 0.4 cm(2), respectively, at 1 year. There were early explantations, 4 of which resulted from paravalvular leaks. One additional valve explantation resulted from aortic root bleeding, probably caused by excessively extensive decalcification. In the late period, there was 1 mild paravalvular leak and no intravalvular insufficiency. No migration, dislodgement, or degeneration of the valve occurred during follow-up. Median follow-up was 444 days. CONCLUSIONS These trials confirm the safety and efficacy of the Perceval sutureless aortic valve, especially in elderly patients requiring AVR + concomitant procedures. In this patient group, sutureless valves may be advantageous compared to transcatheter valve implantations as concomitant procedures other than percutaneous coronary artery angioplasty are not always possible in the latter.
Resumo:
OBJECTIVE Sutureless valves are designed to facilitate surgical implantation, including less-invasive techniques in aortic valve replacement, by maintaining surgical precision of implantation compared with transcatheter techniques. Long-term clinical experience with sutureless valves is lacking. We report the 5-year follow-up results of an international, prospective, multicenter study evaluating the clinical performance and safety of the 3f Enable valve (Medtronic Inc, Minneapolis, Minn). METHODS Between March 2007 and December 2009, 141 patients (54 male; mean age, 76.1±5.7 years) undergoing aortic valve replacement with the 3f Enable valve were enrolled in 10 European sites. The mean follow-up was 2.76 years (range, 2 days to 5.1 years; total, 388.7 patient-years). Echocardiographic valvular hemodynamic and morphologic analyses were performed by an independent core laboratory. RESULTS The mean systolic gradient was 10.4±4.4 mm Hg at discharge and 7.7±4.1 mm Hg at 5 years. The mean effective orifice area was 1.7±0.5 cm2 at discharge and 1.6±0.2 cm2 at 5 years. Freedom from all-cause and valve-related mortality was 87.6%±2.9% and 96.8%±1.6% at 1 year (113 patients at risk) and 77.0%±7.5% and 93.8%±4.8% at 5 years (24 patients at risk), respectively. Six patients underwent reoperation (4 because of major paravalvular leakage and 2 because of endocarditis). Freedom from reoperation was 95.4%±1.9% at 1 year and 95.4%±6.1% at 5 years. No structural valve deterioration occurred during the follow-up period. CONCLUSIONS The sutureless 3f Enable valve represents a safe and effective treatment for aortic valve stenosis, providing an excellent hemodynamic profile. This study represents the longest follow-up study for a sutureless bioprosthesis. Sutureless valves may become an option for all patients with indicated biological aortic valve replacement.
Resumo:
OBJECTIVES The purpose of this study is to delineate changes in aortic geometry and diameter due to dissection. BACKGROUND Aortic diameter is the major criterion for elective ascending aortic replacement for dilated ascending aortas to prevent aortic dissection. However, recommendations are made on the basis of clinical experience and observation of diameters of previously dissected aortas. METHODS Six tertiary centers on 2 continents reviewed their acute aortic dissection type A databases, which contained 1,821 patients. Included were all non-Marfan patients with nonbicuspid aortic valves who had undergone computed tomography angiography <2 years before and within 12 h after aortic dissection onset. Aortic geometry before and after dissection onset were compared. RESULTS Altogether, 63 patients were included (27 spontaneous and 36 retrograde dissections, median age 68 [57; 77] years; 54% were men). In all but 1 patient, maximum ascending aortic diameter was <55 mm before aortic dissection onset. The largest increase in diameter and volume induced by the dissection were observed in the ascending aorta (40.1 [36.6; 45.3] mm vs. 52.9 [46.1; 58.6] mm, +12.8 mm; p < 0.001; 124.0 [90.8; 162.5] cm(3) vs. 171.0 [147.0; 197.0] cm(3), +47 cm(3); p < 0.001). Mean aortic arch diameter increased from 39.8 (30.5; 42.6) mm to 46.4 (42.0; 51.6) mm (+6.6 mm; p < 0.001) and descending thoracic aorta diameter from 31.2 (27.0; 33.3) mm to 34.9 (30.9; 39.5) mm (+3.7 mm; p < 0.001). Changes in thoracic aorta geometry were similar for spontaneous and retrograde etiology. CONCLUSIONS Geometry of the thoracic aorta is affected by aortic dissection, leading to an increase in diameter that is most pronounced in the ascending aorta. Both spontaneous and retrograde dissection result in similar aortic geometry changes.
Resumo:
Numerous designs of bioprosthetic valves exist. The sutureless surgical valve is a newer design concept which combines elements of the transcatheter valve technology with surgical valves. This design aims at shorter and easier implantation. It was the aim of this study to perform hemodynamic and kinematic measurements for this type of valves to serve as a baseline for following studies which investigate the effect of the aortic root on the valve performance. To this end, the Edwards Intuity aortic valve was investigated in a new in vitro flow loop mimicking the left heart. The valve was implanted in a transparent, compliant aortic root model, and the valve kinematics was investigated using a high speed camera together with synchronized hemodynamic measurements of pressures and flows. The valve closure was asynchronous (one by one leaflet), and the valve started to close before the deceleration of the fluid. The aortic root model showed a dilation of the sinuses which was different to the ascending aorta, and the annulus was found to move towards the left ventricle during diastole and towards the aorta during systole.
Resumo:
Immersed boundary simulations have been under development for physiological flows, allowing for elegant handling of fluid-structure interaction modelling with large deformations due to retained domain-specific meshing. We couple a structural system in Lagrangian representation that is formulated in a weak form with a Navier-Stokes system discretized through a finite differences scheme. We build upon a proven highly scalable imcompressible flow solver that we extend to handle FSI. We aim at applying our method to investigating the hemodynamics of Aortic Valves. The code is going to be extended to conform to the new hybrid-node supercomputers.
Resumo:
In this paper, we present a revolutionary vision of 5G networks, in which SDN programs wireless network functions, and where Mobile Network Operators (MNO), Enterprises, and Over-The-Top (OTT) third parties are provided with NFV-ready Network Store. The proposed Network Store serves as a digital distribution platform of programmable Virtualized Network Functions (VNFs) that enable 5G application use-cases. Currently existing application stores, such as Apple's App Store for iOS applications, Google's Play Store for Android, or Ubuntu's Software Center, deliver applications to user specific software platforms. Our vision is to provide a digital marketplace, gathering 5G enabling Network Applications and Network Functions, written to run on top of commodity cloud infrastructures, connected to remote radio heads (RRH). The 5G Network Store will be the same to the cloud as the application store is currently to a software platform.
Resumo:
Conjugation of functional entities with a specific set of optical, mechanical or biological properties to DNA strands allows engineering of sophisticated DNA-containing architectures. Among various hybrid systems, DNA-grafted polymers occupy an important place in modern materials science. In this contribution we present the non-covalent synthesis and properties of DNA-grafted linear supramolecular polymers (SPs), which are assembled in a controllable manner from short chimeric DNA-pyrene oligomers. The synthetic oligomers consist of two parts: a 10 nucleotides long DNA chain and a covalently attached segment of variable number of phosphodiester-linked pyrenes. The temperature-dependent formation of DNA-grafted SPs is described by a nucleation-elongation mechanism. The high tendency of pyrenes to aggregate in water, leads to the rapid formation of SPs. The core of the assemblies consists of stacked pyrenes. They form a 1D platform, to which the DNA chains are attached. Combined spectroscopic and microscopic studies reveal that the major driving forces of the polymerization are π-stacking of pyrenes and hydrophobic interactions, and DNA pairing contributes to a lesser extent. AFM and TEM experiments demonstrate that the 1D SPs appear as elongated ribbons with a length of several hundred nanometers. They exhibit an apparent helical structure with a pitch-to-pitch distance of 50±15 nm. Since DNA pairing is a highly selective process, the ongoing studies are aimed to utilize DNA-grafted SPs for the programmable arrangement of functional entities. For example, the addition of non-modified complementary DNA strands to the DNA-grafted SPs leads to the cooperative formation of higher-order assemblies. Also, our experiments suggest that the fluorescent pyrene core of 1D ribbons serves as an efficient donor platform for energy transfer applications.
Resumo:
Conjugation of functional entities with a specific set of optical, mechanical or biological properties to DNA strands allows engineering of sophisticated DNA-containing architectures. Among various hybrid systems, DNA-grafted polymers occupy an important place in modern materials science. In this contribution we present the non-covalent synthesis and properties of DNA-grafted linear supramolecular polymers (SPs), which are assembled in a controllable manner from short chimeric DNA-pyrene oligomers. The synthetic oligomers consist of two parts: a 10 nucleotides long DNA chain and a covalently attached segment of variable number of phosphodiester-linked pyrenes. The temperature-dependent formation of DNA-grafted SPs is described by a nucleation-elongation mechanism. The high tendency of pyrenes to aggregate in water, leads to the rapid formation of SPs. The core of the assemblies consists of stacked pyrenes. They form a 1D platform, to which the DNA chains are attached. Combined spectroscopic and microscopic studies reveal that the major driving forces of the polymerization are π-stacking of pyrenes and hydrophobic interactions, and DNA pairing contributes to a lesser extent. AFM and TEM experiments demonstrate that the 1D SPs appear as elongated ribbons with a length of several hundred nanometers. They exhibit an apparent helical structure with a pitch-to-pitch distance of 50±15 nm. Since DNA pairing is a highly selective process, the ongoing studies are aimed to utilize DNA-grafted SPs for the programmable arrangement of functional entities. For example, the addition of non-modified complementary DNA strands to the DNA-grafted SPs leads to the cooperative formation of higher-order assemblies. Also, our experiments suggest that the fluorescent pyrene core of 1D ribbons serves as an efficient donor platform for energy transfer applications.