877 resultados para precision fabrication


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes a methodology for spectrophotometric determination of hexamethylenetetramine (HMT) by using chromotropic acid in a phosphoric acid media employing a domestic microwave oven as a source of heating. The reddish-purple soluble product is quantitatively formed after 30 s of irradiation and obeys the Beer´s law in the range between 0.1-1.2 mg L-1 HMT (r = 0.99925). The method was applied successfully in commercial pharmaceutical preparations containing dyes in their composition. The results showed that the method proposed is feasible for simplicity, speed, low cost, precision and accuracy when compared with United States Pharmacopeia official method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow injection method for the quantitative analysis of ketoconazole in tablets, based on the reaction with iron (III) ions, is presented. Ketoconazole forms a red complex with iron ions in an acid medium, with maximum absorbance at 495 nm. The detection limit was estimated to be 1×10--4 mol L-1; the quantitation limit is about 3×10--4 mol L-1 and approximately 30 determinations can be performed in an hour. The results were compared with those obtained with a reference HPLC method. Statistical comparisons were done using the Student's t procedure and the F test. Complete agreement was found at the 0.95 significance level between the proposed flow injection and the HPLC procedures. The two methods present similar precision, i.e., for HPLC the mean relative standard deviation was ca. 1.2% and for FIA ca. 1.6%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method to quantify lycopene and β-carotene in freeze dried tomato pulp by high performance liquid chromatography (HLPC) was validated according to the criteria of selectivity, sensitivity, precision and accuracy, and uncertainty estimation of measurement was determined with data obtained in the validation. The validated method presented is selective in terms of analysis, and it had a good precision and accuracy. Detection limit for lycopene and β-carotene was 4.2 and 0.23 mg 100 g-1, respectively. The estimation of expanded uncertainty (K = 2) for lycopene was 104 ± 21 mg 100 g-1 and for β-carotene was 6.4 ± 1.5 mg 100 g-1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and fast method for determination of 40 basic drugs in human plasma employing gas-chromatography with nitrogen-phosphorus detection was developed and validated. Drugs were extracted from 800 µL of plasma with 250 µL of butyl acetate at basic pH. Aliquots of the organic extract were directly injected on a column with methylsilicone stationary phase. Total chromatographic run time was 25 min. All compounds were detected in concentrations ranging from therapeutic to toxic levels, with intermediate precision CV% below 11.2 and accuracy in the range of 92-114%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nowadays the consumer market demands a gradually increase in the products' quality control. The manual control that exits, used in animal production, shows ineficiency in warrating an increasing percentual of the desirable quality, so this can only be reached when an effective animal tracebility system is applied, from birth to slaughter. Individual electronic identification presents high importance in this focus, providing information recorded directly from the animal. Electronic traceability uses electronic devices that emit a signal activated by a fixed reader placed where it is needed to record a certain event, or uses a manual reader which allows a higher independence of the operator. Knowing the importance of the electronic identification as a tool for applying traceability in animal production, this research had as objective to evaluate the use of transponders in order to garantee the manual reading as well as the fixed antenna reading. The following implant places were analized in piglet, just after their birth: 1) forehead, 2) external ear lobule, 3) the posterior auricular base, and 4) a transponder inserted in a earing implanted in the ear lobule. The factors of skin damage and migration were analized, as well as the reading efficiency. It was found that the best implant place was the posterior ear base.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work aimed the development of a low cost servo-valve that answers to an electronic control signal, for variable rates liquid inputs application. A literature research to define which valve type should be used was made. A mechanically activated proportional valve with an electronically controlled servo-engine was designed and evaluated. Since developed the servo-valve, the system was submited to a number of tests .The evaluation of its behavior was obtained in terms of repeatability, hystheresis and linearity. The test was accomplished in a bench, specially developed for this aim. As a result, were obtained three curves of opening percentage as function of flow rate, describing three opening and closing increments in two different work pressures. The servo-valve presented a good repeatability, reasonable hysteresis and a typically quadratic curve. This one maintained the low cost target. These results were very satisfied because the non-linearity and the hysteresis could be easily corrected by software.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cardboard packing for horticultural products has as main function to protect them. The design of a cardboard packing request the knowledge of the bending stiffens which is depending on the modulus of elasticity. The objective of this work was to calculate the cardboard modulus of elasticity from data obtained in laboratory using physical characterization test, with different methods, and comparing the results with the values obtained experimentally. Ten samples of each cardboard selected for this study were tested in the paper fabrication direction and in its transverse direction. The papers liner and medium resistance to the traction, used to calculate the bending stiffness, was determined in a universal machine test. To obtaining of the bending stiffens the four points test was accomplished. Expressive variations among the methods from which the modulus of elasticity is obtained were observed and that influence the bending stiffness of the structure. The stiffness values obtained experimentally were always greater than the values obtained from analytical method. This difference can be attributed to two factors, the production processes that assurance a larger rigidity than the components separately and the addition of the adhesive layer that is not taken in consideration in the analytic calculations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

No Tillage system is fully incorporated to farming in the region of Campos Gerais, state of Paraná. Accuracy and precision in the planting process are items of great importance for the success of this system. In order to evaluate the planting process, thirty eight farms were selected as sites for analysis of the placement depth of seeds. The research area was 4 or 5 planting rows, evaluating 10 plantlets per row. The average seed depth was around 46 mm, and significant differences between rows were observed in 21 areas. The average coefficient of variation was around 20%, the statistical limit between medium and high. Analyses of other parameters show that those coefficients may represent different errors in the process. The planting process in Campos Gerais can be considered efficient regarding to the average seed depth. However, the analysis of variability implies de need of actions concerning to anthropic and machinery factors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Prey size is an important factor in food consumption. In studies of feeding ecology, prey items are usually measured individually using calipers or ocular micrometers. Among amphibians and reptiles, there are species that feed on large numbers of small prey items (e.g. ants, termites). This high intake makes it difficult to estimate prey size consumed by these animals. We addressed this problem by developing and evaluating a procedure for subsampling the stomach contents of such predators in order to estimate prey size. Specifically, we developed a protocol based on a bootstrap procedure to obtain a subsample with a precision error of at the most 5%, with a confidence level of at least 95%. This guideline should reduce the sampling effort and facilitate future studies on the feeding habits of amphibians and reptiles, and also provide a means of obtaining precise estimates of prey size.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física