948 resultados para portal plane frame
Resumo:
BACKGROUND AND PURPOSE: Daily use of conventional electronic portal imaging devices (EPID) for organ tracking is limited due to the relatively high dose required for high quality image acquisition. We studied the use of a novel dose saving acquisition mode (RadMode) allowing to take images with one monitor unit per image in prostate cancer patients undergoing intensity-modulated radiotherapy (IMRT) and tracking of implanted fiducial gold markers. PATIENTS AND METHODS: Twenty five patients underwent implantation of three fiducial gold markers prior to the planning CT. Before each treatment of a course of 37 fractions, orthogonal localization images from the antero-posterior and from the lateral direction were acquired. Portal images of both the setup procedure and the five IMRT treatment beams were analyzed. RESULTS: On average, four localization images were needed for a correct patient setup, resulting in four monitor units extra dose per fraction. The mean extra dose delivered to the patient was thereby increased by 1.2%. The procedure was precise enough to reduce the mean displacements prior to treatment to < o =0.3 mm. CONCLUSIONS: The use of a new dose saving acquisition mode enables to perform daily EPID-based prostate tracking with a cumulative extra dose of below 1 Gy. This concept is efficiently used in IMRT-treated patients, where separation of setup beams from treatment beams is mandatory.
Resumo:
BACKGROUND: The deletion of three adjacent nucleotides in an exon may cause the lack of a single amino acid, while the protein sequence remains otherwise unchanged. Only one such in-frame deletion is known in the two RH genes, represented by the RHCE allele ceBP expressing a "very weak e antigen." STUDY DESIGN AND METHODS: Blood donor samples were recognized because of discrepant results of D phenotyping. Six samples came from Switzerland and one from Northern Germany. The molecular structures were determined by genomic DNA nucleotide sequencing of RHD. RESULTS: Two different variant D antigens were explained by RHD alleles harboring one in-frame triplet deletion each. Both single-amino-acid deletions led to partial D phenotypes with weak D antigen expression. Because of their D category V-like phenotypes, the RHD(Arg229del) allele was dubbed DVL-1 and the RHD(Lys235del) allele DVL-2. These in-frame triplet deletions are located in GAGAA or GAAGA repeats of the RHD exon 5. CONCLUSION: Partial D may be caused by a single-amino-acid deletion in RhD. The altered RhD protein segments in DVL types are adjacent to the extracellular loop 4, which constitutes one of the most immunogenic parts of the D antigen. These RhD protein segments are also altered in all DV, which may explain the similarity in phenotype. At the nucleotide level, the triplet deletions may have resulted from replication slippage. A total of nine amino acid positions in an Rhesus protein may be affected by this mechanism.
Resumo:
The clinical impact and outcome of a rare radiographic finding of hepatic portal venous gas (HPVG) as well as the effectiveness of computed tomography (CT), CT scanogram, and conventional radiography in the detection of HPVG were retrospectively analyzed. CT scans, CT scanogram, and plain film radiographs of 11 patients with HPVG were reviewed and compared with their medical records and surgical and pathology reports. Eight of the 11 patients underwent plain film radiographs 1 day before or after the CT scan. HPVG was detected at CT in all 11 patients, on CT scanogram in three (3 of 11, 27.3%), and on plain films in one (one of eight, 12.5%). In nine of 11 patients (81.8%), CT revealed an associated pneumatosis intestinalis. In six of the 11 patients (54.6%), acute mesenteric ischemia was the underlying disease for HPVG. Seven patients (63.6%) underwent emergency exploratory laparotomy. The mortality rate for HPVG alone was 27.3% (3 of 11) and for HPVG related to mesenteric bowel disease 50% (three of six). Acute mesenteric ischemia is the most common cause of HPVG, which continues to have a predictably higher mortality. CT is superior to CT scanograms and radiographs in the detection of HPVG and its underlying diseases and, therefore, should be used as the primary diagnostic tool.
Resumo:
Increased understanding of the hyperdynamic circulation syndrome has resulted in novel therapeutic approaches, some of which have already reached clinical practice. Central to the hyperdynamic circulation syndrome is an imbalance between the increase in different vasodilators (foremost among which is nitric oxide) and the compensatory increase in vasoconstrictors--usually accompanied by a blunted response. This chapter discusses the role of endothelin in the pathogenesis of the syndrome and in future treatment approaches. A relatively new area of research in this field is the role of infection and inflammation in the initiation and maintenance of the hyperdynamic circulation syndrome. The use of antibiotics in the setting of acute variceal bleeding is standard practice. Studies have suggested that chronic manipulation of the intestinal flora could have beneficial effects in the treatment of portal hypertension. The bile salts are another novel and interesting target. Although their vasoactive properties have been known for some time, recent data demonstrate that their effects could be central in the pathogenesis of the hyperdynamic circulation syndrome, and that manipulation of the composition of the bile acid pool could be a therapeutic approach to portal hypertension. Finally, hypoxia and angiogenesis play a role in the development of portal hypertension and the formation of collaterals. This role needs to be further defined but it appears likely that this phenomenon is yet another target for therapeutic intervention.
Resumo:
The verification possibilities of dynamically collimated treatment beams with a scanning liquid ionization chamber electronic portal image device (SLIC-EPID) are investigated. The ion concentration in the liquid of a SLIC-EPID and therefore the read-out signal is determined by two parameters of a differential equation describing the creation and recombination of the ions. Due to the form of this equation, the portal image detector describes a nonlinear dynamic system with memory. In this work, the parameters of the differential equation were experimentally determined for the particular chamber in use and for an incident open 6 MV photon beam. The mathematical description of the ion concentration was then used to predict portal images of intensity-modulated photon beams produced by a dynamic delivery technique, the sliding window approach. Due to the nature of the differential equation, a mathematical condition for 'reliable leaf motion verification' in the sliding window technique can be formulated. It is shown that the time constants for both formation and decay of the equilibrium concentration in the chamber is in the order of seconds. In order to guarantee reliable leaf motion verification, these time constants impose a constraint on the rapidity of the image-read out for a given maximum leaf speed. For a leaf speed of 2 cm s(-1), a minimum image acquisition frequency of about 2 Hz is required. Current SLIC-EPID systems are usually too slow since they need about a second to acquire a portal image. However, if the condition is fulfilled, the memory property of the system can be used to reconstruct the leaf motion. It is shown that a simple edge detecting algorithm can be employed to determine the leaf positions. The method is also very robust against image noise.
Resumo:
Today electronic portal imaging devices (EPID's) are used primarily to verify patient positioning. They have, however, also the potential as 2D-dosimeters and could be used as such for transit dosimetry or dose reconstruction. It has been proven that such devices, especially liquid filled ionization chambers, have a stable dose response relationship which can be described in terms of the physical properties of the EPID and the pulsed linac radiation. For absolute dosimetry however, an accurate method of calibration to an absolute dose is needed. In this work, we concentrate on calibration against dose in a homogeneous water phantom. Using a Monte Carlo model of the detector we calculated dose spread kernels in units of absolute dose per incident energy fluence and compared them to calculated dose spread kernels in water at different depths. The energy of the incident pencil beams varied between 0.5 and 18 MeV. At the depth of dose maximum in water for a 6 MV beam (1.5 cm) and for a 18 MV beam (3.0 cm) we observed large absolute differences between water and detector dose above an incident energy of 4 MeV but only small relative differences in the most frequent energy range of the beam energy spectra. It is shown that for a 6 MV beam the absolute reference dose measured at 1.5 cm water depth differs from the absolute detector dose by 3.8%. At depth 1.2 cm in water, however, the relative dose differences are almost constant between 2 and 6 MeV. The effects of changes in the energy spectrum of the beam on the dose responses in water and in the detector are also investigated. We show that differences larger than 2% can occur for different beam qualities of the incident photon beam behind water slabs of different thicknesses. It is therefore concluded that for high-precision dosimetry such effects have to be taken into account. Nevertheless, the precise information about the dose response of the detector provided in this Monte Carlo study forms the basis of extracting directly the basic radiometric quantities photon fluence and photon energy fluence from the detector's signal using a deconvolution algorithm. The results are therefore promising for future application in absolute transit dosimetry and absolute dose reconstruction.
Resumo:
BACKGROUND/AIMS: It is postulated that nitric oxide (NO) is responsible for the hyperdynamic circulation of portal hypertension. Therefore, we investigated induction of fibrosis and hyperdynamic circulation in endothelial NO synthase knock-out (KO) mice. METHODS: Fibrosis was induced by bile duct ligation. Hemodynamic studies were performed after portal vein ligation. All studies were performed in wild-type (WT) and KO mice. RESULTS: Three to 4 weeks after bile duct ligation (BDL), both WT and KO groups had similar degrees of portal hypertension, 12 (9-14) and 11(8-15) mmHg, median (range), and liver function. Fibrosis increased from 0.0% in sham operated to 1.0 and 1.1% in WT and KO mice, respectively. Cardiac output was similar after portal vein ligation (20 and 17 ml/min in WT and KO mice, respectively). There was no difference in liver of mRNA for endothelin 1, inducible NO synthase (iNOS) and hem-oxygenase 1 (HO1); proteins of iNOS, HO1 and HO2; nor in endothelin A and B (EtA and EtB) receptor density between WT and KO mice after BDL. CONCLUSIONS: These results suggest that endothelial NO synthase is neither essential for the development of fibrosis and portal hypertension in bile duct ligated mice, nor for the hyperdynamic circulation associated with portal hypertension in the portal vein ligated mice.
Resumo:
Adding conductive carbon fillers to insulating thermoplastic resins increases composite electrical and thermal conductivity. Often, as much of a single type of carbon filler is added to achieve the desired conductivity, while still allowing the material to be molded into a bipolar plate for a fuel cell. In this study, varying amounts of three different carbons (carbon black, synthetic graphite particles, and carbon fiber) were added to Vectra A950RX Liquid Crystal Polymer. The in-plane thermal conductivity of the resulting single filler composites were tested. The results showed that adding synthetic graphite particles caused the largest increase in the in-plane thermal conductivity of the composite. The composites were modeled using ellipsoidal inclusion problems to predict the effective in-plane thermal conductivities at varying volume fractions with only physical property data of constituents. The synthetic graphite and carbon black were modeled using the average field approximation with ellipsoidal inclusions and the model showed good agreement with the experimental data. The carbon fiber polymer composite was modeled using an assemblage of coated ellipsoids and the model showed good agreement with the experimental data.