994 resultados para piezoelectric sensor
Resumo:
This paper describes a high-performance multiplexed vibration sensor system using fiber lasers. A serial vibration sensor array consists of four short cavity fiber lasers. The system employs a single, polarization-insensitive, unbalanced Michelson interferometer to translate individual laser wavelength shifts induced by vibration signals into interferometer phase shifts. A dense wavelength division demultiplexor (DWDM) with high channel isolation is inserted to demultiplex each laser signal as a wavelength filter. Finally, a digital phase demodulator based on the phase generated carrier technique is used to achieve high-resolution interrogation. Experimental results show that no observable crosstalk is measured on the output channels, and the minimal detectable acceleration of this system is similar to 200ng/root Hz at 250Hz, which is fundamentally limited by the frequency noise of the lasers.
Resumo:
A novel ultra low power temperature sensor for UHF RFID tag chip is presented. The sensor consists of a constant pulse generator, a temperature related oscillator, a counter and a bias. Conversion of temperature to digital output is fulfilled by counting the number of the clocks of the temperature related oscillator in a constant pulse period. The sensor uses time domain comparing, where high power consumption bandgap voltage references and traditional ADCs are not needed. The sensor is realized in a standard 0.18 mu m CMOS process, and the area is only 0.2mm(2). The accuracy of the temperature sensor is +/- 1 degrees C after calibration. The power consumption of the sensor is only 0.9 mu W.
Resumo:
The basic principle and critical characteristics of unattended ground sensors (UGS) based on fiber optic disk accelerometers are introduced. Mechanical principles of fiber optic disk accelerometers (FODA) and calculation methods are presented. An FODA with a high sensitivity of 120rad/g and a resonance frequency of 300Hz is designed and used for detection in military affair.
Resumo:
The performance of the current sensor in power equipment may become worse affected by the environment. In this paper, based on ICA, we propose a method for on-line verification of the phase difference of the current sensor. However, not all source components are mutually independent in our application. In order to get an exact result, we have proposed a relative likelihood index to choose an optimal result from different runs. The index is based on the maximum likelihood evaluation theory and the independent subspace analysis. The feasibility of our method has been confirmed by experimental results.
Resumo:
An enhanced technique for interrogating fiber Bragg grating wavelength shift using cascade wavelength division multiplexer (WDM) couplers was proposed and demonstrated. Three WDM couplers which show a linear filter function over the expected wavelength range are employed and cascaded to track Bragg wavelength shifts. Compared with single WDM demodulator. sharper spectral slope is obtained and considerable linear filter range is kept. The static and dynamic strain sensor demodulation experiments demonstrated that the simple passive technique improves the sensitivity approximately two times and keeps 5nm linear demodulation range based on our devices. The cascade WDM coupler demodulation system has high scan rate which can be used to monitor fast vibration.
Resumo:
A practical package technique for temperature independent Fiber Bragg grating sensor is proposed. A uniform strength cantilever with two FBG attached on the upper and lower surfaces was utilized as the key element. By detecting two wavelengths differential output, the applied force can be obtained and temperature effects can be eliminated. Experiment results show the sensor has linear response and output signal uctuates less than 12pm as temperature changes from -10 degrees C to 50 degrees C. The maximum thermal error is less than 0.3% of the full measurement range.
Resumo:
We study the effect of an external biaxial stress on the light emission of single InGaAs/GaAs(001) quantum dots placed onto piezoelectric actuators. With increasing compression, the emission blueshifts and the binding energies of the positive trion (X+) and biexciton (XX) relative to the neutral exciton (X) show a monotonic increase. This phenomenon is mainly ascribed to changes in electron and hole localization and it provides a robust method to achieve color coincidence in the emission of X and XX, which is a prerequisite for the possible generation of entangled photon pairs via the recently proposed "time reordering'' scheme.
Resumo:
Phosphatidylcholine (PC) and six other PC-similar lipids are coated on interdigital electrodes, IEs, as sensitive membranes. Eight alcohols (C-1-C-4) are tested in a flow system at room temperature. It is found that all responses are log(response)-log(concentration) linear relations. These results agree with Steven's law in psychophysics. Moreover, the thresholds of the sensors are coincident with human olfactory thresholds. The authors have analysed the data of the lipid hypothesis suggested by Kurihara et al. We have found that this hypothesis is also in agreement with Steven's law. Lipid microresistors are real mimicking olfactory sensors. A definition of an olfactory sensor is suggested.
Resumo:
In this paper, an interdigital electrode lipid film odour sensor (ILOS) is designed, fabricated and tested. It is made from a microfabricated chemiresistor coated with a synthetic multibilayer film. Nine odorants in gas phase at room temperature have been detected using the odour sensor. For most of the odorants, the relation between the response of the ILOS and odorant concentration obeys Stevens' power law, and there is a good correlation between the minimum odorant concentrations that give rise to a change of the sensor's conductance and human olfactory thresholds.
Resumo:
For an olfactory sensor or electronic nose the task is not only to detect the object concentration, but also to recognize it. It is well known that all the elements can be identified by their charge to mass ratio e+/m. We tried to use this principle for molecular recognition. Two kinds of sensors are used simultaneously in testing. One is Quartz Crystal Microbalance (QCM) for detecting the change in mass, the other is Interdigital Electrode (IE) for detecting the change in conduction. In this paper the principle and the feasibility of this method are reported. The preliminary results on the recognition of alcohols are presented. The multisensor can be used as an instrument for research on material properties and kinetic process as well.
Resumo:
For an olfactory sensor or electronic nose, the task is not only to detect the object concentration, but also to recognize it. It is well known that all the elements can be identified by their charge to mass ratio e(+)/m. We tried to imitate this principle for molecular recognition. Two kinds of sensors are used simultaneously in testing. One is quartz crystal microbalance (QCM) for detecting the change in mass, the other is interdigital electrode (IE) for detecting the change in conduction, as an electro-mass multi-sensor (EMMS). in this paper, the principle and the feasibility of this method are discussed. The preliminary results on the recognition of alcohol by EMMS coated with lipids are presented. Meanwhile, the multi-sensor can also be used as an instrument for research on some physico-chemistry problems. The change in conduction of coated membrane caused by one absorbed molecule is reported. It is found that when a QCM is coated with membrane, it still obeys the relationship Delta F (frequency change of QCM) = K Delta m (mass change of absorbed substance) and the proportional coefficient, K, depends not only on quartz properties but also on membrane characteristics as well. (C) 2000 Elsevier Science S.A. All rights reserved.