986 resultados para microwave-assisted extraction
Resumo:
In general, Latosols have low levels of available P, however, the influence of the parent material seems to be decisive in defining the pool and predominant form of P in these soils. This study evaluated P availability by extraction with Mehlich-1 (M-1) and Ion Exchange Resin (IER), from samples of B horizons of Ferric and Perferric Latosols developed from different parent materials. To this end, in addition to the physical and chemical characterization of soils, 10 sequential extractions were performed with M-1 and IER from samples of B horizons (depth between 0.8 and 1.0 m). Total contents of Ca, P, Fe, Al, and Ti were determined after digestion with nitric, hydrofluoric and perchloric acids. The effects of sequential P extractions on Fe oxides were also evaluated from the analyses of dithionite-citrate-bicarbonate and ammonium acid oxalate. The high similarity between contents of P accumulated after sequential extractions with M-1 and IER in soils developed on tuffite indicated a predominance of P-Ca. Higher contents of P after a single IER extraction show greater efficiency in P removal from highly weathered soils, as from the Latosols studied here. The P contents also show the high sensitivity of extractant M-1 in highly buffered soils. Furthermore, a single extraction with extractant M-1 or IER is not sufficient to estimate the amount of labile P in these soils.
Resumo:
The Mehlich-1 (M-1) extractant and Monocalcium Phosphate in acetic acid (MCPa) have mechanisms for extraction of available P and S in acidity and in ligand exchange, whether of the sulfate of the extractant by the phosphate of the soil, or of the phosphate of the extractant by the sulfate of the soil. In clayey soils, with greater P adsorption capacity, or lower remaining P (Rem-P) value, which corresponds to soils with greater Phosphate Buffer Capacity (PBC), more buffered for acidity, the initially low pH of the extractants increases over their time of contact with the soil in the direction of the pH of the soil; and the sulfate of the M-1 or the phosphate of the MCPa is adsorbed by adsorption sites occupied by these anions or not. This situation makes the extractant lose its extraction capacity, a phenomenon known as loss of extraction capacity or consumption of the extractant, the object of this study. Twenty soil samples were chosen so as to cover the range of Rem-P (0 to 60 mg L-1). Rem-P was used as a measure of the PBC. The P and S contents available from the soil samples through M-1 and MCPa, and the contents of other nutrients and of organic matter were determined. For determination of loss of extraction capacity, after the rest period, the pH and the P and S contents were measured in both the extracts-soils. Although significant, the loss of extraction capacity of the acidity of the M-1 and MCPa extractants with reduction in the Rem-P value did not have a very expressive effect. A “linear plateau” model was observed for the M-1 for discontinuous loss of extraction capacity of the P content in accordance with reduction in the concentration of the Rem-P or increase in the PBC, suggesting that a discontinuous model should also be adopted for interpretation of available P of soils with different Rem-P values. In contrast, a continuous linear response was observed between the P variables in the extract-soil and Rem-P for the MCPa extractor, which shows increasing loss of extraction capacity of this extractor with an increase in the PBC of the soil, indicating the validity of the linear relationship between the available S of the soil and the PBC, estimated by Rem-P, as currently adopted.
Resumo:
Résumé : Introduction : L'objectif de cette étude était d'une part d'évaluer les caractéristiques histologiques des fragments cellulaires rétiniens attachés à la limitante interne après vitrectomie et pelage d'une membrane epirétinienne, et d'autre part de mettre en évidence des différences histologiques entre les cas opérés avec ou sans l'aide d'ICG dilué dans du glucose 5%. Méthodes Nous avons examiné rétrospectivement l'histologie de 88 spécimens de membranes épimaculaires contenant la limitante interne de la rétine, qui ont été enlevés chirurgicalement entre 1995 et 2003. L'analyse histologique a centré principalement l'attention sur la présence et les caractéristiques des fragments cellulaires rétiniens attachés à la limitante interne. L'analyse statistique a comparé les résultats entre le groupe I (chirurgie conventionnelle sans l'aide de l'ICG) et le groupe II (chirurgie à l'aide de l'ICG). Résultats Soixante et onze patients ont eu une vitrectomie sans l'aide de l'ICG (groupe I) et 17 avec l'aide de l'ICG (groupe II). Le nombre de débris de cellules de Müller à la surface rétinienne de la limitante interne était plus important dans le groupe I (sans ICG) que dans le groupe II (avec ICG) (40.8% versus 11.8% ; p = 0.024). Des larges fragments cellulaires rétiniens attachés à la limitante interne ont été plus fréquemment observés dans le groupe I (sans ICG) que dans le groupe II (avec ICG) (63.4% versus 23.5%; p= 0.003). Dans cinq (7%) cas du groupe I, de gros éléments cellulaires rétiniens ont été mis en évidence (des axones neuraux ou des vaisseaux sanguins). De tels éléments n'ont pas été retrouvés dans les spécimens du groupe II (avec ICG). Conclusions L'utilisation de l'ICG dilué dans du glucose 5% pour faciliter le pelage d'une membrane épimaculaire et notamment l'ablation de la limitante interne de la rétine semble diminuer de manière significative le nombre et la taille des débris des cellules de Muller adhérents à la face rétinienne de la membrane limitante interne de la rétine. Cette observation suggère que l'utilisation per-opératoire d'ICG dilué dans du glucose 5% facilite l'ablation de la limitante interne pendant la chirurgie de la membrane epirétinienne en diminuant l'adhérence de la limitante interne à la rétine.
Resumo:
Three-dimensional imaging and quantification of myocardial function are essential steps in the evaluation of cardiac disease. We propose a tagged magnetic resonance imaging methodology called zHARP that encodes and automatically tracks myocardial displacement in three dimensions. Unlike other motion encoding techniques, zHARP encodes both in-plane and through-plane motion in a single image plane without affecting the acquisition speed. Postprocessing unravels this encoding in order to directly track the 3-D displacement of every point within the image plane throughout an entire image sequence. Experimental results include a phantom validation experiment, which compares zHARP to phase contrast imaging, and an in vivo study of a normal human volunteer. Results demonstrate that the simultaneous extraction of in-plane and through-plane displacements from tagged images is feasible.
Resumo:
The Radiello Passive Air Sampler is one of the latest innovations developed for the sampling of pollutants in the air by passive headspace. It has been reported that its properties allow an enhanced sensitivity, reproducibility and adsorption capacity. It therefore appears to be of interest in the extraction of potential residues of ignitable liquids present in fire debris when arson is suspected. A theoretical approach and several laboratory tests have made it possible to precisely characterize in a forensic perspective the potential of the device in extracting and concentrating the vapors of ignitable liquids found in fire debris. Despite some advantages, the Radiello device appears to be less efficient than traditional axial symmetry samplers.
Endoscopic extraction of a prevertebral migrated guidewire after posterior cervical instrumentation.
Resumo:
Images of Spine Care
Resumo:
Tuberculous spondylitis is rare in economically well-developed countries. MRI is the most sensitive radiologic method of diagnosis. CT-guided fine needle aspiration can be an appropriate method for obtaining samples for culture, with positive cultures in 25 to 89% of cases. However, it can take >6 weeks for specimens to grow, and it is essential to have adequate culture and sensitivity studies for the diagnosis and treatment of mycobacterial diseases. We propose a minimally invasive diagnostic approach that ensures that adequate surgical specimens are obtained prior to initiating treatment.
Resumo:
PURPOSE: To evaluate the histologic features of cellular retinal fragments on the internal limiting membrane (ILM) removed during idiopathic macular epiretinal membrane (MEM) peeling surgery with and without the aid of indocyanine green (ICG) diluted in 5% glucose. METHODS: ILM specimens removed from 88 eyes during idiopathic MEM surgery between 1995 and 2003 were reviewed retrospectively. Histologic analysis focused on the presence and characteristics of retinal fragments on the retinal surface of the ILM. Statistical analysis compared the results between group I (conventional surgery) and group II (ICG-assisted peeling). RESULTS: Seventy-one eyes underwent MEM surgery without the aid of ICG (group I) and seventeen underwent MEM ICG-assisted surgery (group II). The amount of Müller cell debris on the retinal surface of the ILM was more significant in the group I than in the group II (40.8 vs. 11.8; P = 0.024). Large fragments of Müller cells were more frequently observed in the group I (no ICG) than in the group II (ICG) (63.4 vs. 23.5%; P = 0.003). CONCLUSIONS: The use of ICG diluted with 5% glucose in ILM removal during MEM surgery was associated with less retinal debris attached to the retinal face of the ILM compared with surgery in which ICG was not used.
Resumo:
High performance liquid chromatography (HPLC) is the reference method for measuring concentrations of antimicrobials in blood. This technique requires careful sample preparation. Protocols using organic solvents and/or solid extraction phases are time consuming and entail several manipulations, which can lead to partial loss of the determined compound and increased analytical variability. Moreover, to obtain sufficient material for analysis, at least 1 ml of plasma is required. This constraint makes it difficult to determine drug levels when blood sample volumes are limited. However, drugs with low plasma-protein binding can be reliably extracted from plasma by ultra-filtration with a minimal loss due to the protein-bound fraction. This study validated a single-step ultra-filtration method for extracting fluconazole (FLC), a first-line antifungal agent with a weak plasma-protein binding, from plasma to determine its concentration by HPLC. Spiked FLC standards and unknowns were prepared in human and rat plasma. Samples (240 microl) were transferred into disposable microtube filtration units containing cellulose or polysulfone filters with a 5 kDa cut-off. After centrifugation for 60 min at 15000g, FLC concentrations were measured by direct injection of the filtrate into the HPLC. Using cellulose filters, low molecular weight proteins were eluted early in the chromatogram and well separated from FLC that eluted at 8.40 min as a sharp single peak. In contrast, with polysulfone filters several additional peaks interfering with the FLC peak were observed. Moreover, the FLC recovery using cellulose filters compared to polysulfone filters was higher and had a better reproducibility. Cellulose filters were therefore used for the subsequent validation procedure. The quantification limit was 0.195 mgl(-1). Standard curves with a quadratic regression coefficient > or = 0.9999 were obtained in the concentration range of 0.195-100 mgl(-1). The inter and intra-run accuracies and precisions over the clinically relevant concentration range, 1.875-60 mgl(-1), fell well within the +/-15% variation recommended by the current guidelines for the validation of analytical methods. Furthermore, no analytical interference was observed with commonly used antibiotics, antifungals, antivirals and immunosuppressive agents. Ultra-filtration of plasma with cellulose filters permits the extraction of FLC from small volumes (240 microl). The determination of FLC concentrations by HPLC after this single-step procedure is selective, precise and accurate.