949 resultados para low dose irradiation


Relevância:

40.00% 40.00%

Publicador:

Resumo:

To intraindividually compare a low-tube-voltage (80 kVp), high-tube-current (675 mA) computed tomographic (CT) technique with a high-tube-voltage (140 kVp) CT protocol for the detection of pancreatic tumors, image quality, and radiation dose during the pancreatic parenchymal phase.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To investigate whether an adaptive statistical iterative reconstruction (ASIR) algorithm improves the image quality at low-tube-voltage (80-kVp), high-tube-current (675-mA) multidetector abdominal computed tomography (CT) during the late hepatic arterial phase.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A new radiation dose-saving technique for noninvasive coronary artery imaging with computed tomography (CT) is available.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The GLAaS algorithm for pretreatment intensity modulation radiation therapy absolute dose verification based on the use of amorphous silicon detectors, as described in Nicolini et al. [G. Nicolini, A. Fogliata, E. Vanetti, A. Clivio, and L. Cozzi, Med. Phys. 33, 2839-2851 (2006)], was tested under a variety of experimental conditions to investigate its robustness, the possibility of using it in different clinics and its performance. GLAaS was therefore tested on a low-energy Varian Clinac (6 MV) equipped with an amorphous silicon Portal Vision PV-aS500 with electronic readout IAS2 and on a high-energy Clinac (6 and 15 MV) equipped with a PV-aS1000 and IAS3 electronics. Tests were performed for three calibration conditions: A: adding buildup on the top of the cassette such that SDD-SSD = d(max) and comparing measurements with corresponding doses computed at d(max), B: without adding any buildup on the top of the cassette and considering only the intrinsic water-equivalent thickness of the electronic portal imaging devices device (0.8 cm), and C: without adding any buildup on the top of the cassette but comparing measurements against doses computed at d(max). This procedure is similar to that usually applied when in vivo dosimetry is performed with solid state diodes without sufficient buildup material. Quantitatively, the gamma index (gamma), as described by Low et al. [D. A. Low, W. B. Harms, S. Mutic, and J. A. Purdy, Med. Phys. 25, 656-660 (1998)], was assessed. The gamma index was computed for a distance to agreement (DTA) of 3 mm. The dose difference deltaD was considered as 2%, 3%, and 4%. As a measure of the quality of results, the fraction of field area with gamma larger than 1 (%FA) was scored. Results over a set of 50 test samples (including fields from head and neck, breast, prostate, anal canal, and brain cases) and from the long-term routine usage, demonstrated the robustness and stability of GLAaS. In general, the mean values of %FA remain below 3% for deltaD equal or larger than 3%, while they are slightly larger for deltaD = 2% with %FA in the range from 3% to 8%. Since its introduction in routine practice, 1453 fields have been verified with GLAaS at the authors' institute (6 MV beam). Using a DTA of 3 mm and a deltaD of 4% the authors obtained %FA = 0.9 +/- 1.1 for the entire data set while, stratifying according to the dose calculation algorithm, they observed: %FA = 0.7 +/- 0.9 for fields computed with the analytical anisotropic algorithm and %FA = 2.4 +/- 1.3 for pencil-beam based fields with a statistically significant difference between the two groups. If data are stratified according to field splitting, they observed %FA = 0.8 +/- 1.0 for split fields and 1.0 +/- 1.2 for nonsplit fields without any significant difference.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: To determine the acute and late genitourinary (GU) and gastrointestinal (GI) toxicity and present short-term biochemical no evidence of disease (bNED) rates after high-dose-rate brachytherapy (HDR-B) monotherapy. METHODS AND MATERIALS: Between October 2003 and June 2006, 36 patients with low (28) and intermediate (8) risk prostate cancer (PCA) were treated by HDR-B monotherapy. All patients received one implant and four fractions of 9.5Gy within 48h for a total prescribed dose (PD) of 38Gy. Five patients received hormonal therapy (HT). Median age was 63.5 years and median followup was 3 years (range, 0.4-4 years). Toxicity was scored according to the CTCAE version 3.0. Biochemical failure was defined according to the Phoenix criteria. RESULTS: Acute and late Grade 3 GU toxicity was observed in 1 (3%) and 4 (11%) patients, respectively. Grade 3 GI toxicity was absent. The three- year bNED survival rate was 100%. The sexual preservation rate in patients without HT was 75%. Late Grade 3 GU toxicity was associated with the planning target volume (PTV) V(100) (% PTV receiving > or =100% of the PD; p=0.036), D(90) (dose delivered to 90% of the PTV; p=0.02), and the urethral V(120) (urethral volume receiving > or =120% of the PD; p=0.043). The urethral V(120) was associated with increased PTV V(100) (p<0.001) and D(90) (p=0.003). CONCLUSIONS: After HDR-B monotherapy, late Grade 3 GU toxicity is associated with the urethral V(120) and the V(100) and D(90) of the PTV. Decrease of the irradiated urethral volume may reduce the GU toxicity and potentially improve the therapeutic ratio of this treatment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: To evaluate the effect of automatic tube current modulation on radiation dose and image quality for low tube voltage computed tomography (CT) angiography. MATERIALS AND METHODS: An anthropomorphic phantom was scanned with a 64-section CT scanner using following tube voltages: 140 kVp (Protocol A), 120 kVp (Protocol B), 100 kVp (Protocol C), and 80 kVp (Protocol D). To achieve similar noise, combined z-axis and xy-axes automatic tube current modulation was applied. Effective dose (ED) for the four tube voltages was assessed. Three plastic vials filled with different concentrations of iodinated solution were placed on the phantom's abdomen to obtain attenuation measurements. The signal-to-noise ratio (SNR) was calculated and a figure of merit (FOM) for each iodinated solution was computed as SNR(2)/ED. RESULTS: The ED was kept similar for the four different tube voltages: (A) 5.4 mSv +/- 0.3, (B) 4.1 mSv +/- 0.6, (C) 3.9 mSv +/- 0.5, and (D) 4.2 mSv +/- 0.3 (P > .05). As the tube voltage decreased from 140 to 80 kVp, image noise was maintained (range, 13.8-14.9 HU) (P > .05). SNR increased as the tube voltage decreased, with an overall gain of 119% for the 80-kVp compared to the 140-kVp protocol (P < .05). The FOM results indicated that with a reduction of the tube voltage from 140 to 120, 100, and 80 kVp, at constant SNR, ED was reduced by a factor of 2.1, 3.3, and 5.1, respectively, (P < .001). CONCLUSIONS: As tube voltage decreases, automatic tube current modulation for CT angiography yields either a significant increase in image quality at constant radiation dose or a significant decrease in radiation dose at a constant image quality.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE To analyse the clinical outcome after salvage lumpectomy and multi-catheter brachytherapy (MCB) for ipsilateral breast tumour recurrence (IBTR). MATERIAL AND METHODS Between 09/00 and 09/10, 217 patients presenting an IBTR underwent lumpectomy and MCB (low, pulsed, or high-dose rate). Survival rates without second local recurrence (2nd LR), distant metastasis (DM), and overall survival (OS) were analysed as well as late effects and cosmetic results. Univariate and multivariate analyses (MVA) based on IBTR data were performed to find prognostic factors for 2nd LR, DM, and OS. RESULTS Median follow-up after the IBTR was 3.9 years [range: 1.1-10.3]. Five and 10-year actuarial 2nd LR rates were 5.6% [range: 1.5-9.5] and 7.2% [range: 2.1-12.1], respectively. Five and 10-year actuarial DM rates were 9.6% [range: 5.7-15.2] and 19.1% [range: 7.8-28.3], respectively. Five and 10-year actuarial OS rates were 88.7% [range: 83.1-94.8] and 76.4% [range: 66.9-87.3], respectively. In MVA, histological grade was prognostic factor for 2nd LR (p=0.008) and OS (p=0.02); while tumour size was prognostic factor for DM (p=0.03). G3-4 complication rate was 11%. Excellent/good cosmetic result was achieved in 85%. CONCLUSION This study suggests that in case of IBTR, lumpectomy plus MCB is feasible and effective in preventing 2nd LR with an OS rate at least equivalent to those achieved with salvage mastectomy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND In a phase 3, randomised, non-inferiority trial, accelerated partial breast irradiation (APBI) for patients with stage 0, I, and IIA breast cancer who underwent breast-conserving treatment was compared with whole-breast irradiation. Here, we present 5-year follow-up results. METHODS We did a phase 3, randomised, non-inferiority trial at 16 hospitals and medical centres in seven European countries. 1184 patients with low-risk invasive and ductal carcinoma in situ treated with breast-conserving surgery were centrally randomised to either whole-breast irradiation or APBI using multicatheter brachytherapy. The primary endpoint was local recurrence. Analysis was done according to treatment received. This trial is registered with ClinicalTrials.gov, number NCT00402519. FINDINGS Between April 20, 2004, and July 30, 2009, 551 patients had whole-breast irradiation with tumour-bed boost and 633 patients received APBI using interstitial multicatheter brachytherapy. At 5-year follow-up, nine patients treated with APBI and five patients receiving whole-breast irradiation had a local recurrence; the cumulative incidence of local recurrence was 1·44% (95% CI 0·51-2·38) with APBI and 0·92% (0·12-1·73) with whole-breast irradiation (difference 0·52%, 95% CI -0·72 to 1·75; p=0·42). No grade 4 late side-effects were reported. The 5-year risk of grade 2-3 late side-effects to the skin was 3·2% with APBI versus 5·7% with whole-breast irradiation (p=0·08), and 5-year risk of grade 2-3 subcutaneous tissue late side-effects was 7·6% versus 6·3% (p=0·53). The risk of severe (grade 3) fibrosis at 5 years was 0·2% with whole-breast irradiation and 0% with APBI (p=0·46). INTERPRETATION The difference between treatments was below the relevance margin of 3 percentage points. Therefore, adjuvant APBI using multicatheter brachytherapy after breast-conserving surgery in patients with early breast cancer is not inferior to adjuvant whole-breast irradiation with respect to 5-year local control, disease-free survival, and overall survival. FUNDING German Cancer Aid.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In Brazil, a low-latitude country characterized by its high availability and uniformity of solar radiation, the use of PV solar energy integrated in buildings is still incipient. However, at the moment there are several initiatives which give some hints that lead to think that there will be a change shortly. In countries where this technology is already a daily reality, such as Germany, Japan or Spain, the recommendations and basic criteria to avoid losses due to orientation and tilt are widespread. Extrapolating those measures used in high latitudes to all regions, without a previous deeper analysis, is standard practice. They do not always correspond to reality, what frequently leads to false assumptions and may become an obstacle in a country which is taking the first step in this area. In this paper, the solar potential yield for different surfaces in Brazilian cities (located at latitudes between 0° and 30°S) are analyzed with the aim of providing the necessary tools to evaluate the suitability of the buildings’ envelopes for photovoltaic use

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The solar irradiation that a crop receives is directly related to the physical and biological processes that affect the crop. However, the assessment of solar irradiation poses certain problems when it must be measured through fruit inside the canopy of a tree. In such cases, it is necessary to check many test points, which usually requires an expensive data acquisition system. The use of conventional irradiance sensors increases the cost of the experiment, making them unsuitable. Nevertheless, it is still possible to perform a precise irradiance test with a reduced price by using low-cost sensors based on the photovoltaic effect. The aim of this work is to develop a low-cost sensor that permits the measurement of the irradiance inside the tree canopy. Two different technologies of solar cells were analyzed for their use in the measurement of solar irradiation levels inside tree canopies. Two data acquisition system setups were also tested and compared. Experiments were performed in Ademuz (Valencia, Spain) in September 2011 and September 2012 to check the validity of low-cost sensors based on solar cells and their associated data acquisition systems. The observed difference between solar irradiation at high and low positions was of 18.5% ± 2.58% at a 95% confidence interval. Large differences were observed between the operations of the two tested sensors. In the case of a-Si cells based mini-modules, an effect of partial shadowing was detected due to the larger size of the devices, the use of individual c-Si cells is recommended over a-Si cells based mini-modules.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

When aqueous suspensions of gold nanorods are irradiated with a pulsing laser (808 nm), pressure waves appear even at low frequencies (pulse repetition rate of 25 kHz). We found that the pressure wave amplitude depends on the dynamics of the phenomenon. For fixed concentration and average laser current intensity, the amplitude of the pressure waves shows a trend of increasing with the pulse slope and the pulse maximum amplitude.We postulate that the detected ultrasonic pressure waves are a sort of shock waves that would be generated at the beginning of each pulse, because the pressure wave amplitude would be the result of the positive interference of all the individual shock waves.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Low energy X-rays Intra-Operative Radiation Therapy (XIORT) treatment delivered during surgery (ex: INTRABEAM, Carl Zeiss, and Axxent, Xoft) can benefit from accurate and fast dose prediction in a patient 3D volume.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Total Ionization Dose (TID) is traditionally measured by radiation sensitive FETs (RADFETs) that require a radiation hardened Analog-to-Digital Converter (ADC) stage. This work introduces a TID sensor based on a delay path whose propagation time is sensitive to the absorbed radiation. It presents the following advantages: it is a digital sensor able to be integrated in CMOS circuits and programmable systems such as FPGAs; it has a configurable sensitivity that allows to use this device for radiation doses ranging from very low to relatively high levels; its interface helps to integrate this sensor in a multidisciplinary sensor network; it is self-timed, hence it does not need a clock signal that can degrade its accuracy. The sensor has been prototyped in a 0.35μm technology, has an area of 0.047mm2, of which 22% is dedicated to measuring radiation, and an energy per conversion of 463pJ. Experimental irradiation tests have validated the correct response of the proposed TID sensor.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Germ-line mutation induction at mouse minisatellite loci by acute irradiation with x-rays was studied at premeiotic and postmeiotic stages of spermatogenesis. An elevated paternal mutation rate was found after irradiation of premeiotic spermatogonia and stem cells, whereas the frequency of minisatellite mutation after postmeiotic irradiation of spermatids was similar to that in control litters. In contrast, paternal irradiation did not affect the maternal mutation rate. A linear dose–response curve for paternal mutation induced at premeiotic stages was found, with a doubling dose of 0.33 Gy, a value close to those obtained in mice after acute spermatogonia irradiation using other systems for mutation detection. High frequencies of spontaneous and induced mutations at minisatellite loci allow mutation induction to be evaluated at low doses of exposure in very small population samples, which currently makes minisatellite DNA the most powerful tool for monitoring radiation-induced germ-line mutation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The effect of low energy nitrogen molecular ion beam bombardment on metals and compound semiconductors has been studied, with the aim to investigate at the effects of ion and target properties. For this purpose, nitrogen ion implantation in aluminium, iron, copper, gold, GaAs and AIGaAs is studied using XPS and Angle Resolve XPS. A series of experimental studies on N+2 bombardment induced compositional changes, especially the amount of nitrogen retained in the target, were accomplished. Both monoenergetic implantation and non-monoenergetic ion implantation were investigated, using the VG Scientific ESCALAB 200D system and a d. c. plasma cell, respectively. When the samples, with the exception of gold, are exposed to air, native oxide layers are formed on the surfaces. In the case of monoenergetic implantation, the surfaces were cleaned using Ar+ beam bombardment prior to implantation. The materials were then bombarded with N2+ beam and eight sets of successful experiments were performed on each sample, using a rastered N2+ ion beam of energy of 2, 3, 4 and 5 keV with current densities of 1 μA/cm2 and 5 μA/cm22 for each energy. The bombarded samples were examined by ARXPS. After each complete implantation, XPS depth profiles were created using Ar+ beam at energy 2 ke V and current density 2 μA/cm2 . As the current density was chosen as one of the parameters, accurate determination of current density was very important. In the case of glow discharge, two sets of successful experiments were performed in each case, by exposing the samples to nitrogen plasma for the two conditions: at low pressure and high voltage and high pressure and low voltage. These samples were then examined by ARXPS. On the theoretical side, the major problem was prediction of the number of ions of an element that can be implanted in a given matrix. Although the programme is essentially on experimental study, but an attempt is being made to understand the current theoretical models, such as SATVAL, SUSPRE and TRIM. The experimental results were compared with theoretical predictions, in order to gain a better understanding of the mechanisms responsible. From the experimental results, considering possible experimental uncertainties, there is no evidence of significant variation in nitrogen saturation concentration with ion energy or ion current density in the range of 2-5 ke V, however, the retention characteristics of implantant seem to strongly depend on the chemical reactivity between ion species and target material. The experimental data suggests the presence of at least one thermal process. The discrepancy between the theoretical and experimental results could be the inability of the codes to account for molecular ion impact and thermal processes.