992 resultados para iterative method
Resumo:
An implicitly parallel method for integral-block driven restricted active space self-consistent field (RASSCF) algorithms is presented. The approach is based on a model space representation of the RAS active orbitals with an efficient expansion of the model subspaces. The applicability of the method is demonstrated with a RASSCF investigation of the first two excited states of indole
Resumo:
Individuals sampled in hybrid zones are usually analysed according to their sampling locality, morphology, behaviour or karyotype. But the increasing availability of genetic information more and more favours its use for individual sorting purposes and numerous assignment methods based on the genetic composition of individuals have been developed. The shrews of the Sorex araneus group offer good opportunities to test the genetic assignment on individuals identified by their karyotype. Here we explored the potential and efficiency of a Bayesian assignment method combined or not with a reference dataset to study admixture and individual assignment in the difficult context of two hybrid zones between karyotypic species of the Sorex araneus group. As a whole, we assigned more than 80% of the individuals to their respective karyotypic categories (i.e. 'pure' species or hybrids). This assignment level is comparable to what was obtained for the same species away from hybrid zones. Additionally, we showed that the assignment result for several individuals was strongly affected by the inclusion or not of a reference dataset. This highlights the importance of such comparisons when analysing hybrid zones. Finally, differences between the admixture levels detected in both hybrid zones support the hypothesis of an impact of chromosomal rearrangements on gene flow.
Resumo:
Iterative image reconstruction algorithms provide significant improvements over traditional filtered back projection in computed tomography (CT). Clinically available through recent advances in modern CT technology, iterative reconstruction enhances image quality through cyclical image calculation, suppressing image noise and artifacts, particularly blooming artifacts. The advantages of iterative reconstruction are apparent in traditionally challenging cases-for example, in obese patients, those with significant artery calcification, or those with coronary artery stents. In addition, as clinical use of CT has grown, so have concerns over ionizing radiation associated with CT examinations. Through noise reduction, iterative reconstruction has been shown to permit radiation dose reduction while preserving diagnostic image quality. This approach is becoming increasingly attractive as the routine use of CT for pediatric and repeated follow-up evaluation grows ever more common. Cardiovascular CT in particular, with its focus on detailed structural and functional analyses, stands to benefit greatly from the promising iterative solutions that are readily available.
Resumo:
AIMS: BRAF is mutated in 50-60% of melanomas, but BRAF mutation in sarcomas has not been systematically evaluated. Some melanomas are spindled and may show no immunohistochemical evidence of melanocytic differentiation. Similarly, many sarcomas are undifferentiated, i.e. undifferentiated pleomorphic sarcomas (UPS). Diagnosing melanoma versus sarcoma in an undifferentiated spindle cell malignancy can be challenging. Our aim was to evaluate the prevalence of BRAF mutation in sarcomas and the use of BRAF mutational status in the diagnosis of spindle cell malignancies. METHODS AND RESULTS: BRAF mutational analysis was performed on tissue from 104 patients: 90 with sarcoma only (50 UPS) and 14 with sarcoma and melanoma (seven UPS). In the sarcoma-only group, BRAF mutation was absent. In the sarcoma-melanoma group, three sarcomas showed BRAF mutation; all were UPS, occurred after the melanomas and did not stain for melanocytic markers. One melanoma-sarcoma pair showed identical BRAF V600E mutations. CONCLUSIONS: The presence of BRAF mutation in these tumours raises the possibility that poorly differentiated spindle cell malignancies with BRAF mutation may represent melanomas, and BRAF mutational analysis should be considered in a patient with a spindle cell malignancy and a history of melanoma, as a positive result may indicate de-differentiated melanoma.
Resumo:
The purpose of this paper is to describe the development and to test the reliability of a new method called INTERMED, for health service needs assessment. The INTERMED integrates the biopsychosocial aspects of disease and the relationship between patient and health care system in a comprehensive scheme and reflects an operationalized conceptual approach to case mix or case complexity. The method is developed to enhance interdisciplinary communication between (para-) medical specialists and to provide a method to describe case complexity for clinical, scientific, and educational purposes. First, a feasibility study (N = 21 patients) was conducted which included double scoring and discussion of the results. This led to a version of the instrument on which two interrater reliability studies were performed. In study 1, the INTERMED was double scored for 14 patients admitted to an internal ward by a psychiatrist and an internist on the basis of a joint interview conducted by both. In study 2, on the basis of medical charts, two clinicians separately double scored the INTERMED in 16 patients referred to the outpatient psychiatric consultation service. Averaged over both studies, in 94.2% of all ratings there was no important difference between the raters (more than 1 point difference). As a research interview, it takes about 20 minutes; as part of the whole process of history taking it takes about 15 minutes. In both studies, improvements were suggested by the results. Analyses of study 1 revealed that on most items there was considerable agreement; some items were improved. Also, the reference point for the prognoses was changed so that it reflected both short- and long-term prognoses. Analyses of study 2 showed that in this setting, less agreement between the raters was obtained due to the fact that the raters were less experienced and the scoring procedure was more susceptible to differences. Some improvements--mainly of the anchor points--were specified which may further enhance interrater reliability. The INTERMED proves to be a reliable method for classifying patients' care needs, especially when used by experienced raters scoring by patient interview. It can be a useful tool in assessing patients' care needs, as well as the level of needed adjustment between general and mental health service delivery. The INTERMED is easily applicable in the clinical setting at low time-costs.
Resumo:
The application of the Fry method to measure strain in deformed porphyritic granites is discussed. This method requires that the distribution of markers has to satisfy at least two conditions. It has to be homogeneous and isotropic. Statistics on point distribution with the help of a Morishita diagram can easily test homogeneity. Isotropy can be checked with a cumulative histogram of angles between points. Application of these tests to undeformed (Mte Capanne granite, Elba) and to deformed (Randa orthogneiss, Alps of Switzerland) porphyritic granite reveals that their K-feldspars phenocrysts both satisfy these conditions and can be used as strain markers with the Fry method. Other problems are also examined. One is the possible distribution of deformation on discrete shear-bands. Providing several tests are met, we conclude that the Fry method can be used to estimate strain in deformed porphyritic granites. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
In vivo dosimetry is a way to verify the radiation dose delivered to the patient in measuring the dose generally during the first fraction of the treatment. It is the only dose delivery control based on a measurement performed during the treatment. In today's radiotherapy practice, the dose delivered to the patient is planned using 3D dose calculation algorithms and volumetric images representing the patient. Due to the high accuracy and precision necessary in radiation treatments, national and international organisations like ICRU and AAPM recommend the use of in vivo dosimetry. It is also mandatory in some countries like France. Various in vivo dosimetry methods have been developed during the past years. These methods are point-, line-, plane- or 3D dose controls. A 3D in vivo dosimetry provides the most information about the dose delivered to the patient, with respect to ID and 2D methods. However, to our knowledge, it is generally not routinely applied to patient treatments yet. The aim of this PhD thesis was to determine whether it is possible to reconstruct the 3D delivered dose using transmitted beam measurements in the context of narrow beams. An iterative dose reconstruction method has been described and implemented. The iterative algorithm includes a simple 3D dose calculation algorithm based on the convolution/superposition principle. The methodology was applied to narrow beams produced by a conventional 6 MV linac. The transmitted dose was measured using an array of ion chambers, as to simulate the linear nature of a tomotherapy detector. We showed that the iterative algorithm converges quickly and reconstructs the dose within a good agreement (at least 3% / 3 mm locally), which is inside the 5% recommended by the ICRU. Moreover it was demonstrated on phantom measurements that the proposed method allows us detecting some set-up errors and interfraction geometry modifications. We also have discussed the limitations of the 3D dose reconstruction for dose delivery error detection. Afterwards, stability tests of the tomotherapy MVCT built-in onboard detector was performed in order to evaluate if such a detector is suitable for 3D in-vivo dosimetry. The detector showed stability on short and long terms comparable to other imaging devices as the EPIDs, also used for in vivo dosimetry. Subsequently, a methodology for the dose reconstruction using the tomotherapy MVCT detector is proposed in the context of static irradiations. This manuscript is composed of two articles and a script providing further information related to this work. In the latter, the first chapter introduces the state-of-the-art of in vivo dosimetry and adaptive radiotherapy, and explains why we are interested in performing 3D dose reconstructions. In chapter 2 a dose calculation algorithm implemented for this work is reviewed with a detailed description of the physical parameters needed for calculating 3D absorbed dose distributions. The tomotherapy MVCT detector used for transit measurements and its characteristics are described in chapter 3. Chapter 4 contains a first article entitled '3D dose reconstruction for narrow beams using ion chamber array measurements', which describes the dose reconstruction method and presents tests of the methodology on phantoms irradiated with 6 MV narrow photon beams. Chapter 5 contains a second article 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations. A dose reconstruction process specific to the use of the tomotherapy MVCT detector is presented in chapter 6. A discussion and perspectives of the PhD thesis are presented in chapter 7, followed by a conclusion in chapter 8. The tomotherapy treatment device is described in appendix 1 and an overview of 3D conformai- and intensity modulated radiotherapy is presented in appendix 2. - La dosimétrie in vivo est une technique utilisée pour vérifier la dose délivrée au patient en faisant une mesure, généralement pendant la première séance du traitement. Il s'agit de la seule technique de contrôle de la dose délivrée basée sur une mesure réalisée durant l'irradiation du patient. La dose au patient est calculée au moyen d'algorithmes 3D utilisant des images volumétriques du patient. En raison de la haute précision nécessaire lors des traitements de radiothérapie, des organismes nationaux et internationaux tels que l'ICRU et l'AAPM recommandent l'utilisation de la dosimétrie in vivo, qui est devenue obligatoire dans certains pays dont la France. Diverses méthodes de dosimétrie in vivo existent. Elles peuvent être classées en dosimétrie ponctuelle, planaire ou tridimensionnelle. La dosimétrie 3D est celle qui fournit le plus d'information sur la dose délivrée. Cependant, à notre connaissance, elle n'est généralement pas appliquée dans la routine clinique. Le but de cette recherche était de déterminer s'il est possible de reconstruire la dose 3D délivrée en se basant sur des mesures de la dose transmise, dans le contexte des faisceaux étroits. Une méthode itérative de reconstruction de la dose a été décrite et implémentée. L'algorithme itératif contient un algorithme simple basé sur le principe de convolution/superposition pour le calcul de la dose. La dose transmise a été mesurée à l'aide d'une série de chambres à ionisations alignées afin de simuler la nature linéaire du détecteur de la tomothérapie. Nous avons montré que l'algorithme itératif converge rapidement et qu'il permet de reconstruire la dose délivrée avec une bonne précision (au moins 3 % localement / 3 mm). De plus, nous avons démontré que cette méthode permet de détecter certaines erreurs de positionnement du patient, ainsi que des modifications géométriques qui peuvent subvenir entre les séances de traitement. Nous avons discuté les limites de cette méthode pour la détection de certaines erreurs d'irradiation. Par la suite, des tests de stabilité du détecteur MVCT intégré à la tomothérapie ont été effectués, dans le but de déterminer si ce dernier peut être utilisé pour la dosimétrie in vivo. Ce détecteur a démontré une stabilité à court et à long terme comparable à d'autres détecteurs tels que les EPIDs également utilisés pour l'imagerie et la dosimétrie in vivo. Pour finir, une adaptation de la méthode de reconstruction de la dose a été proposée afin de pouvoir l'implémenter sur une installation de tomothérapie. Ce manuscrit est composé de deux articles et d'un script contenant des informations supplémentaires sur ce travail. Dans ce dernier, le premier chapitre introduit l'état de l'art de la dosimétrie in vivo et de la radiothérapie adaptative, et explique pourquoi nous nous intéressons à la reconstruction 3D de la dose délivrée. Dans le chapitre 2, l'algorithme 3D de calcul de dose implémenté pour ce travail est décrit, ainsi que les paramètres physiques principaux nécessaires pour le calcul de dose. Les caractéristiques du détecteur MVCT de la tomothérapie utilisé pour les mesures de transit sont décrites dans le chapitre 3. Le chapitre 4 contient un premier article intitulé '3D dose reconstruction for narrow beams using ion chamber array measurements', qui décrit la méthode de reconstruction et présente des tests de la méthodologie sur des fantômes irradiés avec des faisceaux étroits. Le chapitre 5 contient un second article intitulé 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations'. Un procédé de reconstruction de la dose spécifique pour l'utilisation du détecteur MVCT de la tomothérapie est présenté au chapitre 6. Une discussion et les perspectives de la thèse de doctorat sont présentées au chapitre 7, suivies par une conclusion au chapitre 8. Le concept de la tomothérapie est exposé dans l'annexe 1. Pour finir, la radiothérapie «informationnelle 3D et la radiothérapie par modulation d'intensité sont présentées dans l'annexe 2.
Resumo:
The research presented in this report provides the basis for the development of a new procedure to be used by the Iowa DOT and cities and counties in the state to deal with detours. Even though the project initially focused on investigating new tools to determine condition and compensation, the focus was shifted to traffic and the gas tax method to set the basis for the new procedure. It was concluded that the condition-based approach, even though accurate and consistent condition evaluations can be achieved, is not feasible or cost effective because of the current practices of data collection (two-year cycle) and also the logistics of the procedure (before and after determination). The gas tax method provides for a simple, easy to implement, and consistent approach to dealing with compensation for use of detours. It removes the subjectivity out of the current procedures and provides for a more realistic (traffic based) approach to the compensation determination.
Resumo:
We describe a simple method to achieve both hemostasis and stabilization of the left anterior descending coronary artery during minimally invasive coronary artery bypass grafting. This technique allows the surgeon to perform a precise anastomosis of the left internal mammary artery to the target vessel on a beating heart.
Resumo:
Morphological descriptors are practical and essential biomarkers for diagnosis andtreatment selection for intracranial aneurysm management according to the current guidelinesin use. Nevertheless, relatively little work has been dedicated to improve the three-dimensionalquanti cation of aneurysmal morphology, automate the analysis, and hence reduce the inherentintra- and inter-observer variability of manual analysis. In this paper we propose a methodologyfor the automated isolation and morphological quanti cation of saccular intracranial aneurysmsbased on a 3D representation of the vascular anatomy.
Resumo:
In this paper we propose a new approach for tonic identification in Indian art music and present a proposal for acomplete iterative system for the same. Our method splits the task of tonic pitch identification into two stages. In the first stage, which is applicable to both vocal and instrumental music, we perform a multi-pitch analysis of the audio signal to identify the tonic pitch-class. Multi-pitch analysisallows us to take advantage of the drone sound, which constantlyreinforces the tonic. In the second stage we estimate the octave in which the tonic of the singer lies and is thusneeded only for the vocal performances. We analyse the predominant melody sung by the lead performer in order to establish the tonic octave. Both stages are individually evaluated on a sizable music collection and are shown toobtain a good accuracy. We also discuss the types of errors made by the method.Further, we present a proposal for a system that aims to incrementally utilize all the available data, both audio and metadata in order to identify the tonic pitch. It produces a tonic estimate and a confidence value, and is iterative in nature. At each iteration, more data is fed into the systemuntil the confidence value for the identified tonic is above a defined threshold. Rather than obtain high overall accuracy for our complete database, ultimately our goal is to develop a system which obtains very high accuracy on a subset of the database with maximum confidence.
Resumo:
In this paper a method for extracting semantic informationfrom online music discussion forums is proposed. The semantic relations are inferred from the co-occurrence of musical concepts in forum posts, using network analysis. The method starts by defining a dictionary of common music terms in an art music tradition. Then, it creates a complex network representation of the online forum by matchingsuch dictionary against the forum posts. Once the complex network is built we can study different network measures, including node relevance, node co-occurrence andterm relations via semantically connecting words. Moreover, we can detect communities of concepts inside the forum posts. The rationale is that some music terms are more related to each other than to other terms. All in all, this methodology allows us to obtain meaningful and relevantinformation from forum discussions.
Resumo:
This paper presents our investigation on iterativedecoding performances of some sparse-graph codes on block-fading Rayleigh channels. The considered code ensembles are standard LDPC codes and Root-LDPC codes, first proposed in and shown to be able to attain the full transmission diversity. We study the iterative threshold performance of those codes as a function of fading gains of the transmission channel and propose a numerical approximation of the iterative threshold versus fading gains, both both LDPC and Root-LDPC codes.Also, we show analytically that, in the case of 2 fading blocks,the iterative threshold root of Root-LDPC codes is proportional to (α1 α2)1, where α1 and α2 are corresponding fading gains.From this result, the full diversity property of Root-LDPC codes immediately follows.
Resumo:
Lexical Resources are a critical component for Natural Language Processing applications. However, the high cost of comparing and merging different resources has been a bottleneck to obtain richer resources and a broader range of potential uses for a significant number of languages. With the objective of reducing cost by eliminating human intervention, we present a new method towards the automatic merging of resources. This method includes both, the automatic mapping of resources involved to a common format and merging them, once in this format. This paper presents how we have addressed the merging of two verb subcategorization frame lexica for Spanish, but our method will be extended to cover other types of Lexical Resources. The achieved results, that almost replicate human work, demonstrate the feasibility of the approach.