984 resultados para high-field ferromagnetic resonance
Resumo:
Given their high sensitivity and ability to limit the field of view (FOV), surface coils are often used in magnetic resonance spectroscopy (MRS) and imaging (MRI). A major downside of surface coils is their inherent radiofrequency (RF) B1 heterogeneity across the FOV, decreasing with increasing distance from the coil and giving rise to image distortions due to non-uniform spatial responses. A robust way to compensate for B1 inhomogeneities is to employ adiabatic inversion pulses, yet these are not well adapted to all imaging sequences - including to single-shot approaches like echo planar imaging (EPI). Hybrid spatiotemporal encoding (SPEN) sequences relying on frequency-swept pulses provide another ultrafast MRI alternative, that could help solve this problem thanks to their built-in heterogeneous spatial manipulations. This study explores how this intrinsic SPEN-based spatial discrimination, could be used to compensate for the B1 inhomogeneities inherent to surface coils. Experiments carried out in both phantoms and in vivo rat brains demonstrate that, by suitably modulating the amplitude of a SPEN chirp pulse that progressively excites the spins in a direction normal to the coil, it is possible to compensate for the RF transmit inhomogeneities and thus improve sensitivity and image fidelity.
Resumo:
The possible coexistence of ferromagnetism and charge/orbital order in Bi3/4Sr1/4MnO3 has been investigated. The manganite Bi0.75Sr0.25MnO3, with commensurate charge balance, undergoes an electronic transition at TCO~600 K that produces a longrange modulation with double periodicity along a and c axis, and unusual anisotropic evolution of the lattice parameters. The previously proposed ferromagnetic properties of this new ordered phase were studied by magnetometry and diffraction techniques. In zero field the magnetic structure is globally antiferromagnetic, ruling out the apparition of spontaneous ferromagnetism. However, the application of magnetic fields produces a continuous progressive canting of the moments, inducing a ferromagnetic phase even for relatively small fields (H<<1 T). Application of pulsed high fields produces a remarkable and reversible spin polarization (under 30 T, the ferromagnetic moment is ~3 ¿B/Mn, without any sign of charge order melting). The coexistence of ferromagnetism and charge order at low and very-high fields is a remarkable property of this system.
Resumo:
Le traitement de radiochirurgie par Gamma Knife (GK) est utilisé de plus en plus souvent comme une alternative à la microchirurgie conventionnelle pour le traitement des pathologies neurochirurgicales intracrâniennes. Il s'agit d'irradier en dose unique et à haute énergie, en condition stéréotaxique et à l'aide d'une imagerie multimodale (imagerie par résonance magnétique [IRM], tomodensitométrie et éventuellement artériographie). Le GK a été inventé par le neurochirurgien suédois Lars Leksell, qui a réalisé le premier ciblage du nerf trijumeau en 1951, sur la base d'une radiographie standard. Depuis, les progrès de l'informatique et de la robotique ont permis d'améliorer la technique de radiochirurgie qui s'effectue actuellement soit par accélérateur linéaire de particules monté sur un bras robotisé (Novalis®, Cyberknife®), soit par collimation de près de 192 sources fixes (GK). La principale indication radiochirurgicale dans le traitement de la douleur est la névralgie du nerf trijumeau. Les autres indications, plus rares, sont la névralgie du nerf glossopharyngien, l'algie vasculaire de la face, ainsi qu'un traitement de la douleur d'origine cancéreuse par hypophysiolyse. Gamma Knife surgery (GKS) is widely used as an alternative to open microsurgical procedures as noninvasive treatment of many intracranial conditions. It consists of delivering a single dose of high energy in stereotactic conditions, and with the help of a multimodal imaging (e.g., magnetic resonance imaging [MRI], computer tomography, and eventually angiography). The Gamma Knife (GK) was invented by the Swedish neurosurgeon Lars Leksell who was the first to treat a trigeminal neuralgia sufferer in 1951 using an orthogonal X-ray tube. Since then, the progresses made both in the field of informatics and robotics have allowed to improve the radiosurgical technique, which is currently performed either by a linear accelerator of particles mounted on a robotized arm (Novalis®, Cyberknife®), or by collimation of 192 fixed Co-60 sources (GK). The main indication of GKS in the treatment of pain is trigeminal neuralgia. The other indications, less frequent, are: glossopharyngeal neuralgia, cluster headache, and hypophysiolyse for cancer pain.
Resumo:
PURPOSE: This study aims to investigate physical performance and hematological changes in 32 elite male team-sport players after 14 d of "live high-train low" (LHTL) training in normobaric hypoxia (≥14 h·d at 2800-3000 m) combined with repeated-sprint training (six sessions of four sets of 5 × 5-s sprints with 25 s of passive recovery) either in normobaric hypoxia at 3000 m (LHTL + RSH, namely, LHTLH; n = 11) or in normoxia (LHTL + RSN, namely, LHTL; n = 12) compared with controlled "live low-train low" (LLTL; n = 9) training. METHODS: Before (Pre), immediately after (Post-1), and 3 wk after (Post-2) the intervention, hemoglobin mass (Hbmass) was measured in duplicate [optimized carbon monoxide (CO) rebreathing method], and vertical jump, repeated-sprint (8 × 20 m-20 s recovery), and Yo-Yo Intermittent Recovery level 2 (YYIR2) performances were tested. RESULTS: Both hypoxic groups similarly increased their Hbmass at Post-1 and Post-2 in reference to Pre (LHTLH: +4.0%, P < 0.001 and +2.7%, P < 0.01; LHTL: +3.0% and +3.0%, both P < 0.001), whereas no change occurred in LLTL. Compared with Pre, YYIR2 performance increased by ∼21% at Post-1 (P < 0.01) and by ∼45% at Post-2 (P < 0.001), with no difference between the two intervention groups (vs no change in LLTL). From Pre to Post-1, cumulated sprint time decreased in LHTLH (-3.6%, P < 0.001) and LHTL (-1.9%, P < 0.01), but not in LLTL (-0.7%), and remained significantly reduced at Post-2 (-3.5%, P < 0.001) in LHTLH only. Vertical jump performance did not change. CONCLUSIONS: "Live high-train low and high" hypoxic training interspersed with repeated sprints in hypoxia for 14 d (in season) increases the Hbmass, YYIR2 performance, and repeated-sprint ability of elite field team-sport players, with benefits lasting for at least 3 wk postintervention.
Resumo:
BACKGROUND: For free-breathing cardiovascular magnetic resonance (CMR), the self-navigation technique recently emerged, which is expected to deliver high-quality data with a high success rate. The purpose of this study was to test the hypothesis that self-navigated 3D-CMR enables the reliable assessment of cardiovascular anatomy in patients with congenital heart disease (CHD) and to define factors that affect image quality. METHODS: CHD patients ≥2 years-old and referred for CMR for initial assessment or for a follow-up study were included to undergo a free-breathing self-navigated 3D CMR at 1.5T. Performance criteria were: correct description of cardiac segmental anatomy, overall image quality, coronary artery visibility, and reproducibility of great vessels diameter measurements. Factors associated with insufficient image quality were identified using multivariate logistic regression. RESULTS: Self-navigated CMR was performed in 105 patients (55% male, 23 ± 12y). Correct segmental description was achieved in 93% and 96% for observer 1 and 2, respectively. Diagnostic quality was obtained in 90% of examinations, and it increased to 94% if contrast-enhanced. Left anterior descending, circumflex, and right coronary arteries were visualized in 93%, 87% and 98%, respectively. Younger age, higher heart rate, lower ejection fraction, and lack of contrast medium were independently associated with reduced image quality. However, a similar rate of diagnostic image quality was obtained in children and adults. CONCLUSION: In patients with CHD, self-navigated free-breathing CMR provides high-resolution 3D visualization of the heart and great vessels with excellent robustness.
Resumo:
Thyroid fine-needle aspiration (FNA) cytology is a fast growing field. One of the most developing areas is represented by molecular tests applied to cytological material. Patients that could benefit the most from these tests are those that have been diagnosed as 'indeterminate' on FNA. They could be better stratified in terms of malignancy risk and thus oriented with more confidence to the appropriate management. Taking in to consideration the need to improve and keep high the yield of thyroid FNA, professionals from various fields (i.e. molecular biologists, endocrinologists, nuclear medicine physicians and radiologists) are refining and fine-tuning their diagnostic instruments. In particular, all these developments aim at increasing the negative predictive value of FNA to improve the selection of patients for diagnostic surgery. These advances involve terminology, the application of next-generation sequencing to thyroid FNA, the use of immunocyto- and histo-chemistry, the development of new sampling techniques and the increasing use of nuclear medicine as well as molecular imaging in the management of patients with a thyroid nodule. Herein, we review the recent advances in thyroid FNA cytology that could be of interest to the 'thyroid-care' community, with particular focus on the indeterminate diagnostic category.
Resumo:
(Matrix-assisted) laser desorption/ionization ((MA)LDI) mass spectrometry imaging (MSI) has been driven by remarkable technological developments in the last couple of years. Although molecular information of a wide range of molecules including peptides, lipids, metabolites, and xenobiotics can be mapped, (MA)LDI MSI only leads to the detection of the most abundant soluble molecules in the cells and, consequently, does not provide access to the least expressed species, which can be very informative in the scope of disease research. Within a short period of time, numerous protocols and concepts have been developed and introduced in order to increase MSI sensitivity, including in situ tissue chemistry and solvent-free matrix depositions. In this chapter, we will discuss some of the latest developments in the field of high-sensitivity MSI using solvent-free matrix depositions and will detail protocols of two methods with their capability of enriching molecular MSI signal as demonstrated within our laboratory.
Resumo:
Conventional (CONV) neuromuscular electrical stimulation (NMES) (i.e., short pulse duration, low frequencies) induces a higher energetic response as compared to voluntary contractions (VOL). In contrast, wide-pulse, high-frequency (WPHF) NMES might elicit-at least in some subjects (i.e., responders)-a different motor unit recruitment compared to CONV that resembles the physiological muscle activation pattern of VOL. We therefore hypothesized that for these responder subjects, the metabolic demand of WPHF would be lower than CONV and comparable to VOL. 18 healthy subjects performed isometric plantar flexions at 10% of their maximal voluntary contraction force for CONV (25 Hz, 0.05 ms), WPHF (100 Hz, 1 ms) and VOL protocols. For each protocol, force time integral (FTI) was quantified and subjects were classified as responders and non-responders to WPHF based on k-means clustering analysis. Furthermore, a fatigue index based on FTI loss at the end of each protocol compared with the beginning of the protocol was calculated. Phosphocreatine depletion (ΔPCr) was assessed using 31P magnetic resonance spectroscopy. Responders developed four times higher FTI's during WPHF (99 ± 37 ×103 N.s) than non-responders (26 ± 12 ×103 N.s). For both responders and non-responders, CONV was metabolically more demanding than VOL when ΔPCr was expressed relative to the FTI. Only for the responder group, the ∆PCr/FTI ratio of WPHF (0.74 ± 0.19 M/N.s) was significantly lower compared to CONV (1.48 ± 0.46 M/N.s) but similar to VOL (0.65 ± 0.21 M/N.s). Moreover, the fatigue index was not different between WPHF (-16%) and CONV (-25%) for the responders. WPHF could therefore be considered as the less demanding NMES modality-at least in this subgroup of subjects-by possibly exhibiting a muscle activation pattern similar to VOL contractions.
Resumo:
This book is the transcript of a witness seminar on the history of experimental economics, in which eleven high-profile experimental economists participated, including Nobel Laureates Vernon Smith, Reinhard Selten and Alvin Roth. The witness seminar was constructed along four different topics: skills, community, laboratory, and funding. The transcript is preceded by an introduction explaining the method of the witness seminar and its specific set-up and resuming its results. The participants' contribution and their lively discussion provide a wealth of insights into the emergence of experimental economics as a field of research.
Resumo:
We report on a field-effect light emitting device based on silicon nanocrystals in silicon oxide deposited by plasma-enhanced chemical vapor deposition. The device shows high power efficiency and long lifetime. The power efficiency is enhanced up to 0.1 %25 by the presence of a silicon nitride control layer. The leakage current reduction induced by this nitride buffer effectively increases the power efficiency two orders of magnitude with regard to similarly processed devices with solely oxide. In addition, the nitride cools down the electrons that reach the polycrystalline silicon gate lowering the formation of defects, which significantly reduces the device degradation.
Resumo:
PURPOSE: To assess the prevalence of PRPH2 in autosomal dominant retinitis pigmentosa (adRP), to report 6 novel mutations, to characterize the biochemical features of a recurrent novel mutation, and to study the clinical features of adRP patients. DESIGN: Retrospective clinical and molecular genetic study. METHODS: Clinical investigations included visual field testing, fundus examination, high-resolution spectral-domain optical coherence tomography (OCT), fundus autofluorescence imaging, and electroretinogram (ERG) recording. PRPH2 was screened by Sanger sequencing in a cohort of 310 French families with adRP. Peripherin-2 protein was produced in yeast and analyzed by Western blot. RESULTS: We identified 15 mutations, including 6 novel and 9 previously reported changes in 32 families, accounting for a prevalence of 10.3% in this adRP population. We showed that a new recurrent p.Leu254Gln mutation leads to protein aggregation, suggesting abnormal folding. The clinical severity of the disease in examined patients was moderate with 78% of the eyes having 1-0.5 of visual acuity and 52% of the eyes retaining more than 50% of the visual field. Some patients characteristically showed vitelliform deposits or macular involvement. In some families, pericentral RP or macular dystrophy were found in family members while widespread RP was present in other members of the same families. CONCLUSIONS: The mutations in PRPH2 account for 10.3% of adRP in the French population, which is higher than previously reported (0%-8%) This makes PRPH2 the second most frequent adRP gene after RHO in our series. PRPH2 mutations cause highly variable phenotypes and moderate forms of adRP, including mild cases, which could be underdiagnosed.
Resumo:
Species may cope with rapid habitat changes by distribution shifts or adaptation to new conditions. A common feature of these responses is that they depend on how the process of dispersal connects populations, both demographically and genetically. We analyzed the genetic structure of a near-threatened high-Arctic seabird, the ivory gull (Pagophila eburnea) in order to infer the connectivity among gull colonies. We analyzed 343 individuals sampled from 16 localities across the circumpolar breeding range of ivory gulls, from northern Russia to the Canadian Arctic. To explore the roles of natal and breeding dispersal, we developed a population genetic model to relate dispersal behavior to the observed genetic structure of worldwide ivory gull populations. Our key finding is the striking genetic homogeneity of ivory gulls across their entire distribution range. The lack of population genetic structure found among colonies, in tandem with independent evidence of movement among colonies, suggests that ongoing effective dispersal is occurring across the Arctic Region. Our results contradict the dispersal patterns generally observed in seabirds where species movement capabilities are often not indicative of dispersal patterns. Model predictions show how natal and breeding dispersal may combine to shape the genetic homogeneity among ivory gull colonies separated by up to 2800 km. Although field data will be key to determine the role of dispersal for the demography of local colonies and refine the respective impacts of natal versus breeding dispersal, conservation planning needs to consider ivory gulls as a genetically homogeneous, Arctic-wide metapopulation effectively connected through dispersal.
Resumo:
The detailed in-vivo characterization of subcortical brain structures is essential not only to understand the basic organizational principles of the healthy brain but also for the study of the involvement of the basal ganglia in brain disorders. The particular tissue properties of basal ganglia - most importantly their high iron content, strongly affect the contrast of magnetic resonance imaging (MRI) images, hampering the accurate automated assessment of these regions. This technical challenge explains the substantial controversy in the literature about the magnitude, directionality and neurobiological interpretation of basal ganglia structural changes estimated from MRI and computational anatomy techniques. My scientific project addresses the pertinent need for accurate automated delineation of basal ganglia using two complementary strategies: ? Empirical testing of the utility of novel imaging protocols to provide superior contrast in the basal ganglia and to quantify brain tissue properties; ? Improvement of the algorithms for the reliable automated detection of basal ganglia and thalamus Previous research demonstrated that MRI protocols based on magnetization transfer (MT) saturation maps provide optimal grey-white matter contrast in subcortical structures compared with the widely used Tl-weighted (Tlw) images (Helms et al., 2009). Under the assumption of a direct impact of brain tissue properties on MR contrast my first study addressed the question of the mechanisms underlying the regional specificities effect of the basal ganglia. I used established whole-brain voxel-based methods to test for grey matter volume differences between MT and Tlw imaging protocols with an emphasis on subcortical structures. I applied a regression model to explain the observed grey matter differences from the regionally specific impact of brain tissue properties on the MR contrast. The results of my first project prompted further methodological developments to create adequate priors for the basal ganglia and thalamus allowing optimal automated delineation of these structures in a probabilistic tissue classification framework. I established a standardized workflow for manual labelling of the basal ganglia, thalamus and cerebellar dentate to create new tissue probability maps from quantitative MR maps featuring optimal grey-white matter contrast in subcortical areas. The validation step of the new tissue priors included a comparison of the classification performance with the existing probability maps. In my third project I continued investigating the factors impacting automated brain tissue classification that result in interpretational shortcomings when using Tlw MRI data in the framework of computational anatomy. While the intensity in Tlw images is predominantly
Resumo:
Objective To evaluate intra- and interobserver agreement in the identification of incidental enchondromas at knee magnetic resonance imaging, and to assess the prevalence of imaging findings. Materials and Methods Retrospective study reviewing 326 knee magnetic resonance images acquired in the period between November 2009 and September 2010. The images were independently and blindly analyzed by two specialists in musculoskeletal radiology, with the objective of identifying incidental enchondromas, presence of foci with signal similar to bone marrow and foci of signal absence suggestive of calcifications within the enchondromas. Inter- and intraobserver agreements were analyzed. Results Eleven lesions compatible with enchondromas (3.3%) were identified. The interobserver agreement for the presence of enchondroma was high. Prevalence of foci of bone marrow signal inside the enchondromas was of 54.55%, and foci suggestive of calcification corresponded to 36.36%. The intraobserver agreement for foci of bone marrow signal in enchondromas was perfect, and interobserver agreement was high. Conclusion The prevalence of incidental enchondromas in the current study was compatible with data in the literature. Excellent agreement was observed in the identification of enchondromas and in the assessment of imaging findings. A higher prevalence of fat signal foci was observed as compared with signal absence suggestive of calcifications.