985 resultados para hadrontherapy,proton therapy,space radioprotection,FOOT,nuclear fragmentation,nuclear cross section
Resumo:
This study evaluated the influence of bone marrow aspirate (BMA), low-level laser therapy (LLLT) and their combination on bone healing in surgically created critical-size defects (CSDs) in rat calvaria. 40 rats were divided into four groups: C (control), BMA, LLLT and BMA/LLLT. A 5 mm diameter CSD was created in the calvarium of each animal. In Group C, the defect was filled by blood clot only. In Group BMA, the defect was filled with BMA. In groups LLLT and BMA/LLLT, the defect received laser irradiation (InGaAlP laser), was filled with blood clot or BMA respectively, and irradiated again. Animals were euthanized 30 days postoperatively. Histomorphometric and immunohistochemical analyses were performed. Newly formed bone area (NFBA) was calculated as percentage of the total area of the original defect. Proliferating cell nuclear antigen (PCNA), runt-related transcription factor 2 (Runx2) and osteocalcin (OCN) immunohistochemical staining were performed. PCNA-positive, Runx2-positive and OCN-positive cells were quantified. Data were statistically analyzed. Group BMA/LLLT had significantly greater NFBA than groups C, BMA or LLLT. Group BMA presented significantly greater NFBA than control, while group LLLT did not. Group BMA/LLLT presented a significantly higher number of PCNA-positive and OCN-positive cells than any of the other groups. Groups BMA/LLLT and BMA showed a significantly lower number of Runx2-positive cells than groups C or LLLT. The combination of BMA/LLLT yielded significantly greater bone formation in surgically created CSD in rat calvaria when compared to control, or either treatment alone. © 2013 Elsevier B.V. All rights reserved.
Resumo:
The gerbil is a rodent considered a good model for studies of prostatic morphophysiology under different experimental conditions. Studies involving castration and steroidal blockers of aged gerbils showed that the glandular epithelium persists after long-term therapy, preventing the organ atrophy. Thus, the objective of this study was to evaluate the phenotypic characteristics and behavior of prostatic epithelial cells that remained after different periods of hormone ablation in aged gerbils. The identification of elements that influenced the survival of this cell type was performed by morphometric, nuclear phenotypes, ultrastructural and immune histochemical analysis. The most significant responses to treatment, by analyzing morphometric features, were observed during the first three time points (day 1, day 3, and day 7), after which there appeared to be an adjustment of the gland to the hormone ablation. All treatments led to changes in the state of chromatin condensation, DNA methylation pattern and phenotypic changes indicated cell senescence. Additionally, an increase in the basal cells seemed to guarantee self-renewal properties to the epithelium. These data indicate that changes occur at many levels, including gene expression and nuclear architecture in the epithelial cells, when aging and steroidal blockade are associated. These aspects are important when considering castration-resistant prostate cancer, a malignant tumor posing difficult therapeutic intervention. © 2013 Elsevier GmbH. All rights reserved.
Resumo:
O objetivo desta tese foi desenvolver um magnetômetro à precessão nuclear para prospecção geofísica e estações-base magnéticas. O magnetômetro à precessão nuclear mede a intensidade total do campo magnético. Seu funcionamento é baseado na ressonância magnética nuclear. A medida de campo é feita pela de terminação da freqüência de precessão de núcleos de hidrogênio – prótons - de líquidos não viscosos no campo magnético terrestre. O magnetômetro é constituído de duas partes: o sensor e o instrumento de medida. O sensor é uma bobina solenoidal, cujo núcleo é preenchido com o líquido. Três líquidos diferentes foram testados; água, propanol e um querosene sintético. Optou-se pelo uso do querosene porque oferece maior amplitude no sinal de precessão, dando, conseqüentemente, maior relação sinal/ ruído. O sistema de medida contém os circuitos de sintonia e amplificação do sinal e, os circuitos lógicos para a programação da operação e contagem da freqüência de precessão. Cada ciclo de medida tem duração de 3 segundos, sendo 2,3s para a polarização e 0,7s para a recepção do sinal. São possíveis dois modos de operação: manual, reciclando automaticamente e por controle remoto. O sinal de precessão é amplificado seletivamente em uma das 14 faixas de sintonia, que cobrem medidas entre 22000 e 95000 gammas. A freqüência de precessão é multiplicada por um fator de 64 e contada durante um tempo igual a 0,36699s, determinado com base na razão giromagnética do próton. O número de pulsos contados é numericamente igual ao valor do campo magnético em gammas. A resposta pode ser lida em mostradores digitais ou na saída BCD paralela quando operando por controle remoto. A precisão da medida é de 1 gamma. O instrumento foi testado no campo para avaliar a relação sinal/ruído, gradiente suportável e consumo de potência. Nos testes de aplicação do protótipo, foram obtidos dados de variação diurna e realizaram-se levantamentos magnético de reconhecimento e detalhe em um sítio arqueológico na Ilha de Marajó, Pará. As respostas dos testes foram comparados com dois magnetômetros comerciais - o GP-70, McPhar e o G-816, Geometrics e, ainda, com dados do Observatório Magnético de Tatuoca-Pa. Em todos os casos, a comparação dos dados mostrou bom desempenho do magnetômetro em teste.
Resumo:
Pós-graduação em Química - IQ
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The Nuclear Medicine is a medical specialty which uses different radioisotopes for diagnostic and therapeutic purposes. The isotopes are radioactive elements which are administered in vivo and present distribution to specific organs or cell types. The knowledge of radioactivity and notions related to ionizing radiation allow to contextualize the radiological protection measures to be taken in Nuclear Medicine. So it is possible to minimize unnecessary exposure to patients, the public, and individuals occupationally exposed and the environmental. For this it is necessary to relate the physical and technological bases apply to this mode with the standards established by regulatory agencies, including the CNEN (National Nuclear Energy Commission) and ANVISA (National Agency for Sanitary Vigilance). In this scenario, it is important that the theoretical endorse the activities which are periodically audited for verification of compliance with the standards that aim to radioprotection. One role of the Medical Physicist in these services is, therefore, act as Radiation Protection Supervisor exerting numerous activities and ensuring compliance with these standards. In this context the stage in the area of Nuclear Medicine was developed in many customers of the enterprise Rad Dimenstein & Associados LTDA, among them the hospitals Israelita Albert Einstein (HIAE), Nossa Senhora de Lourdes (HNSL), Santa Paula (HSP), Cruz Azul (CRAZ), Grupo Fleury, among other clinics. Following the routine and then carrying out various activities pertaining to the Medical Physicist in the area, it was noted that the measures and actions are extremely effective and fundamental in terms of radiological protection
Resumo:
Due the differences between interaction physics process with matter for protons and photons, the proton beam tomography (pCT) has some vantages to comparison with conventional tomography. Also it is confirmed that usually pCT has better dose distribution and highest contrast resolution. The pCT allow not only view the internal structure of an object without destroying it, but also directly measure of volume density of electrons. Also it is confirmed that usually pCT has better dose distribution and highest contrast resolution. At the same time, there are many scientific and technical aspects to a detailed study: the capacity and limitations of the pCT methods are not well clarified. Through computations, based on Monte Carlo Method was carried out a detailed study of the contribution of non-elastic nuclear spreading, and together was compared with an analytical model for the deflection angle and the lateral deflection of protons in the target volume. The programs used were SRIM 2006 code and MCNPX v.2.50 code
Resumo:
The goal of this work is to study the process of interaction of protons with matter through Monte Carlo simulation. For this purpose, it was employed the SRIM program (Stopping and Range of Ions in Matter ) and MCNPX (Monte Carlo N-Particle eXtended) v2.50. This work is going to support the development of a tomography system with protons. It was studied the interaction of proton with the follow materials: Polimethyl Mehacralate (PMMA), MS20 Tissue Substitute and water. This work employed energies in range of 50 MeV and 250 MeV, that is the range of clinical interest. The energy loss of proton after cross a material layer, the decreasing of its intensity, the angular and lateral de ection of incident beam, including and excluding nuclear interactions. This work is related with Medical Physics and Material Physics, like interaction of radiation with matter, particle transport phenomena, and the experimental methods in Nuclear Physics like simulation and computational by Monte Carlo method
Resumo:
Nuclear medicine is a medical specialty related to imagery that deals with imaging techniques, diagnosis and therapy, allowing observing the physiological state of tissues noninvasively by marking the molecules participating of these physiological processes with radioactive isotopes, thus creating the called radionuclides. The image of a radionuclide is one of the most important applications of radioactivity in nuclear medicine. The equipment’s of nuclear medicine imaging use the principle of radiation detection, turning it into an electrical signal which, through specific algorithms, allows forming tomographic images that provide information about the functional status of organs. New detection systems have been developed for tomographic acquisitions using solid state detectors. These devices use crystals of cadmium zinc telluride (CdZnTe). Some of the advantages of this detector are a significant improvement of signal to noise ratio, the increased spectral and spatial resolution, which in sum, result in greater clarity of the images obtained, opening new perspectives for imaging protocols previously unattainable. In contrast, all other gamma-cameras equipped with vacuum tubes have remained relatively unchanged for nearly fifty years. In these gamma-cameras, the images are obtained using two steps significantly less efficient: the gamma rays are converted to light through a first device, and then the light is converted into an electrical signal through a second device. One of functions the Medical Physicist is related to the quality control of equipment. This control ensures that the information and images provided are true and thus credible to be used in medical reports. To perform this type of analysis the physicist must understand the performance characteristics and operation of all equipment of the department concerned; besides, in the absence of specific legislation, proposing...(Complete abstract click electronic access below)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The nuclear dependence of the neutron-proton mass difference is examined in a relativistic harmonic quark model with the assumption of a swelling of the individual nucleon originated by a decrease of the spring constant inside the nuclear medium. A decrease of the neutron-proton mass difference is obtained which is reasonably small and in the right direction to cope with the Nollen-Schiffer anomaly in mirror nuclei. © 1992 Società Italiana di Fisica.
Resumo:
Perioperative fluid therapy remains a highly debated topic. Its purpose is to maintain or restore effective circulating blood volume during the immediate perioperative period. Maintaining effective circulating blood volume and pressure are key components of assuring adequate organ perfusion while avoiding the risks associated with either organ hypo- or hyperperfusion. Relative to perioperative fluid therapy, three inescapable conclusions exist: overhydration is bad, underhydration is bad, and what we assume about the fluid status of our patients may be incorrect. There is wide variability of practice, both between individuals and institutions. The aims of this paper are to clearly define the risks and benefits of fluid choices within the perioperative space, to describe current evidence-based methodologies for their administration, and ultimately to reduce the variability with which perioperative fluids are administered. Based on the abovementioned acknowledgements, a group of 72 researchers, well known within the field of fluid resuscitation, were invited, via email, to attend a meeting that was held in Chicago in 2011 to discuss perioperative fluid therapy. From the 72 invitees, 14 researchers representing 7 countries attended, and thus, the international Fluid Optimization Group (FOG) came into existence. These researches, working collaboratively, have reviewed the data from 162 different fluid resuscitation papers including both operative and intensive care unit populations. This manuscript is the result of 3 years of evidence-based, discussions, analysis, and synthesis of the currently known risks and benefits of individual fluids and the best methods for administering them. The results of this review paper provide an overview of the components of an effective perioperative fluid administration plan and address both the physiologic principles and outcomes of fluid administration. We recommend that both perioperative fluid choice and therapy be individualized. Patients should receive fluid therapy guided by predefined physiologic targets. Specifically, fluids should be administered when patients require augmentation of their perfusion and are also volume responsive. This paper provides a general approach to fluid therapy and practical recommendations.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this work we have studied the radiation effects on MOSFET electronic devices. The integrated circuits were exposed to 10 key X-ray radiation and 2.6 MeV energy proton beam. We have irradiated MOSFET devices with two different geometries: rectangular-gate transistor and circular-gate transistor. We have observed the cumulative dose provokes shifts on the threshold voltage and increases or decreases the transistor's off-state and leakage current. The position of the trapped charges in modern CMOS technology devices depends on radiation type, dose rate, total dose, applied bias and is a function of device geometry. We concluded the circular-gate transistor is more tolerant to radiation than the rectangular-gate transistor. (C) 2011 Elsevier B.V. All rights reserved.