981 resultados para drug dose escalation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background - Pelvis and hip radiography are consistently found to be amongst the highest contributors to the collective effective dose (E) in all ten DOSE DATAMED countries in Europe, representing 2.8 to 9.4% of total collective dose (S) in the TOP 20 exams list. The level of image quality should provide all the diagnostic information in order not to jeopardise the diagnosis, but being able to provide the needed clinical information with the minimum dose. A recent study suggests further research to determine whether the “10 kVp rule” would have value for a range of examinations using Computed Radiography (CR) systems. As a “rule of thumb” increasing the kVp by 10 whilst halving the mAs is suggested to give a similar perceptual image quality when compared to the original exposure factors. Aims - In light of the 10kVp rule, this study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and E for pelvis imaging using automatic exposure control (AEC) and non-AEC in a Computed Radiography (CR) system. Research questions - Does the 10kVp rule works for the pelvis in relation to image quality in a CR system? Does the image quality differs when the AEC is used instead of manual mode using the 10kVp rule and how this impacts on E?

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Ramo de especialização: Terapia com Radiações

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A norfloxacina e o trimetoprim são dois antibióticos antibacterianos usados para o tratamento de infeções urinárias, intestinais e respiratórias. A maioria dos fármacos exige uma dosagem que garanta os níveis de segurança e eficácia de atuação. A necessidade de dosear os medicamentos e os seus metabolitos é assim um controlo imperioso e em muitos casos regular no tratamento de um paciente. Neste trabalho desenvolveram-se dois sensores eletroquímicos para a deteção da norfloxacina (NFX) e do trimetoprim (TMP), usando como superfície de suporte o carbono vítreo. A busca de novos materiais que conferiram maior seletividade e sensibilidade aos sistemas de deteção e por outro lado apresentem menores riscos para o paciente quando usados em dispositivos que permitam uma análise point-of-care, é especialmente importante e pode ser uma parte crucial do processo de decisão clínica. Assim, os polímeros molecularmente impresos enquadram-se nesse perfil e o seu uso tem vindo a ser cada vez mais avaliado. A impressão molecular é uma tecnologia capaz de produzir polímeros que incorporam as moléculas do analito e que após remoção por solventes específicos, permitem dotá-los de locais específicos de reconhecimento estereoquímico. A seleção do pirrol como polímero molecularmente impresso (MIP) permitiu construir com sucesso os sensores para doseamento dos antibióticos. A fim de aumentar a sensibilidade do método incorporou-se grafeno na superfície do elétrodo. Este material tem vindo a ser largamente utilizado devido às suas propriedades: estrutura molecular, condutividade elétrica e aumento da superfície são algumas das características que mais despertam o interesse para a sua aplicação neste projeto. Os sensores desenvolvidos foram incorporados em sistemas eletroquímicos. Os métodos voltamétricos aplicados foram a voltametria cíclica, a voltametria de onda quadrada e ainda a impedância. As condições de análise foram otimizadas no que respeita à polimerização do pirrol (concentração do polímero, número de ciclos de eletropolimerização e respetivos potenciais aplicados, tempo de incubação, solvente de remoção do analito), ao pH da solução do fármaco, à gama de concentrações dos antibióticos e aos parâmetros voltamétricos dos métodos de análise. Para cada um dos antibióticos um elétrodo não-impresso foi também preparado, usando o procedimento de polimerização mas sem a presença da molécula do analito, e foi usado como controlo. O sensor desenvolvido para o trimetoprim foi usado no doseamento do fármaco em amostras de urina. As amostras foram analisadas sem qualquer diluição, apenas foram centrifugadas para remoção de proteínas e algum interferente. Os sensores construídos apresentaram comportamento linear na gama de concentrações entre 102 e 107 mol/L. Os resultados mostram boa precisão (desvios padrão inferiores a 11%) e os limites de deteção foram de 8,317 e 1,307 mol/L para a norfloxacina e o trimetoprim, respetivamente. Para validação do método foram ainda efetuados ensaios de recuperação tendo obtido valores superiores a 94%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Distribuição Individual Diária em Dose Unitária deve assegurar o maior rigor no Processo de Distribuição de Medicamentos, o que nem sempre se verificou no Hospital Pedro Hispano, dado que as Doses Unitárias devolvidas pelos Serviços de Internamento, nem sempre seguiam os Parâmetros de Qualidade. Assim, desenvolveu-se um estudo quasi-experimental, longitudinal, prospetivo e analítico, entre 1 de Março a 30 de Junho de 2012, no qual se analisaram as Doses Unitárias, devolvidas pelos Serviços de Internamento da Unidade Local de Saúde de Matosinhos a funcionam com Distribuição Individual Diária em Dose Unitária, tendo-se recolhido as não conformes relativamente aos Parâmetros de Qualidade instituídos. Na 1.ª fase do estudo (Recolha de amostras), foram contabilizadas 337 amostras, correspondentes a uma perda de 471 €. Na 2.ª fase do estudo (Implementação de acções correctivas às amostras previamente recolhidas), foram rejeitadas definitivamente 129 amostras, correspondentes a uma perda de 198 €. Na 4.ª fase do estudo (Segunda recolha de amostras), foram contabilizadas 228 amostras, correspondentes a uma perda de 199 €. A 3.ª fase do estudo incluiu a divulgação dos resultados às enfermeiras chefes dos serviços envolvidos no estudo e a 5.ª fase a comparação dos resultados obtidos na 1.ª, 2.ª e 4.ª fase do estudo. As amostras foram recolhidas em 16 serviços de internamento, sendo os valores monetários mais relevantes associados ao Espessante para alimentos líquidos e ao Imipeno + Cilastatina. A prática observada e sujeita a estudo aumenta os riscos associados ao consumo do medicamento e os custos relativos ao Processo, sendo de eliminar. A sua monitorização deve constituir uma rotina, uma vez que houve mudança de comportamentos. A redução/eliminação desta prática não conforme conduz à integração de novas tarefas com valor acrescentado, com aumento da fiabilidade do Processo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To analyze drug use trends among college students in 1996, 2001 and 2009. METHODS: A cross-sectional epidemiological study with a multistage stratified cluster sample with 9,974 college students was conducted in the city of São Paulo, southeastern Brazil. An anonymous self-administered questionnaire was used to collect information on drug use assessed in lifetime, the preceding 12 months and the preceding 30 days. The Bonferroni correction was used for multiple comparisons of drug use rates between surveys. RESULTS: There were changes in the lifetime use of tobacco and some other drugs (hallucinogens [6.1% to 8.8%], amphetamines [4.6% to 8.7%], and tranquilizers [5.7% to 8.2%]) from 1996 to 2009. Differences in the use of other drugs over the 12 months preceding the survey were also seen: reduced use of inhalants [9.0% to 4.8%] and increased use of amphetamines [2.4% to 4.8%]. There was a reduction in alcohol [72.9% to 62.1%], tobacco [21.3% to 17.2%] and marijuana [15.0% to 11.5%] use and an increase in amphetamine use [1.9% to 3.3%] in the preceeding 30 days. CONCLUSIONS: Over the 13-year study period, there was an increase in lifetime use of tobacco, hallucinogens, amphetamines, and tranquilizers. There was an increase in amphetamine use and a reduction in alcohol use during the preceding 12 months. There was an increase in amphetamine use during the preceding 30 days.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

X-ray fluoroscopy is essential in both diagnosis and medical intervention, although it may contribute to significant radiation doses to patients that have to be optimised and justified. Therefore, it is crucial to the patient to be exposed to the lowest achievable dose without compromising the image quality. The purpose of this study was to perform an analysis of the quality control measurements, particularly dose rates, contrast and spatial resolution of Portuguese fluoroscopy equipment and also to provide a contribution to the establishment of reference levels for the equipment performance parameters. Measurements carried out between 2007 and 2013 on 143 fluoroscopy equipment distributed by 34 nationwide health units were analysed. The measurements suggest that image quality and dose rates of Portuguese equipment are congruent with other studies, and in general, they are as per the Portuguese law. However, there is still a possibility of improvements intending optimisation at a national level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Medical imaging is a powerful diagnostic tool. Consequently, the number of medical images taken has increased vastly over the past few decades. The most common medical imaging techniques use X-radiation as the primary investigative tool. The main limitation of using X-radiation is associated with the risk of developing cancers. Alongside this, technology has advanced and more centres now use CT scanners; these can incur significant radiation burdens compared with traditional X-ray imaging systems. The net effect is that the population radiation burden is rising steadily. Risk arising from X-radiation for diagnostic medical purposes needs minimising and one way to achieve this is through reducing radiation dose whilst optimising image quality. All ages are affected by risk from X-radiation however the increasing population age highlights the elderly as a new group that may require consideration. Of greatest concern are paediatric patients: firstly they are more sensitive to radiation; secondly their younger age means that the potential detriment to this group is greater. Containment of radiation exposure falls to a number of professionals within medical fields, from those who request imaging to those who produce the image. These staff are supported in their radiation protection role by engineers, physicists and technicians. It is important to realise that radiation protection is currently a major European focus of interest and minimum competence levels in radiation protection for radiographers have been defined through the integrated activities of the EU consortium called MEDRAPET. The outcomes of this project have been used by the European Federation of Radiographer Societies to describe the European Qualifications Framework levels for radiographers in radiation protection. Though variations exist between European countries radiographers and nuclear medicine technologists are normally the professional groups who are responsible for exposing screening populations and patients to X-radiation. As part of their training they learn fundamental principles of radiation protection and theoretical and practical approaches to dose minimisation. However dose minimisation is complex – it is not simply about reducing X-radiation without taking into account major contextual factors. These factors relate to the real world of clinical imaging and include the need to measure clinical image quality and lesion visibility when applying X-radiation dose reduction strategies. This requires the use of validated psychological and physics techniques to measure clinical image quality and lesion perceptibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The purpose of this review is to gather and analyse current research publications to evaluate Sinogram-Affirmed Iterative Reconstruction (SAFIRE). The aim of this review is to investigate whether this algorithm is capable of reducing the dose delivered during CT imaging while maintaining image quality. Recent research shows that children have a greater risk per unit dose due to increased radiosensitivity and longer life expectancies, which means it is particularly important to reduce the radiation dose received by children. Discussion: Recent publications suggest that SAFIRE is capable of reducing image noise in CT images, thereby enabling the potential to reduce dose. Some publications suggest a decrease in dose, by up to 64% compared to filtered back projection, can be accomplished without a change in image quality. However, literature suggests that using a higher SAFIRE strength may alter the image texture, creating an overly ‘smoothed’ image that lacks contrast. Some literature reports SAFIRE gives decreased low contrast detectability as well as spatial resolution. Publications tend to agree that SAFIRE strength three is optimal for an acceptable level of visual image quality, but more research is required. The importance of creating a balance between dose reduction and image quality is stressed. In this literature review most of the publications were completed using adults or phantoms, and a distinct lack of literature for paediatric patients is noted. Conclusion: It is necessary to find an optimal way to balance dose reduction and image quality. More research relating to SAFIRE and paediatric patients is required to fully investigate dose reduction potential in this population, for a range of different SAFIRE strengths.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The discovery of X-rays was undoubtedly one of the greatest stimulus for improving the efficiency in the provision of healthcare services. The ability to view, non-invasively, inside the human body has greatly facilitated the work of professionals in diagnosis of diseases. The exclusive focus on image quality (IQ), without understanding how they are obtained, affect negatively the efficiency in diagnostic radiology. The equilibrium between the benefits and the risks are often forgotten. It is necessary to adopt optimization strategies to maximize the benefits (image quality) and minimize risk (dose to the patient) in radiological facilities. In radiology, the implementation of optimization strategies involves an understanding of images acquisition process. When a radiographer adopts a certain value of a parameter (tube potential [kVp], tube current-exposure time product [mAs] or additional filtration), it is essential to know its meaning and impact of their variation in dose and image quality. Without this, any optimization strategy will be a failure. Worldwide, data show that use of x-rays has been increasingly frequent. In Cabo Verde, we note an effort by healthcare institutions (e.g. Ministry of Health) in equipping radiological facilities and the recent installation of a telemedicine system requires purchase of new radiological equipment. In addition, the transition from screen-films to digital systems is characterized by a raise in patient exposure. Given that this transition is slower in less developed countries, as is the case of Cabo Verde, the need to adopt optimization strategies becomes increasingly necessary. This study was conducted as an attempt to answer that need. Although this work is about objective evaluation of image quality, and in medical practice the evaluation is usually subjective (visual evaluation of images by radiographer / radiologist), studies reported a correlation between these two types of evaluation (objective and subjective) [5-7] which accredits for conducting such studies. The purpose of this study is to evaluate the effect of exposure parameters (kVp and mAs) when using additional Cooper (Cu) filtration in dose and image quality in a Computed Radiography system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare image quality and effective dose when the 10 kVp rule is applied with manual and AEC mode in PA chest X-ray. Methods and Materials: A total of 68 images (with and without lesions) were acquired of an anthropomorphic chest phantom in a Wolverson Arcoma X-ray unit. The images were evaluated against a reference image using image quality criteria and the 2 alternative forced choice (2 AFC) method by five radiographers. The effective dose was calculated using PCXMC software using the exposure parameters and DAP. The exposure index (lgM) was recorded. Results: Exposure time decreases considerably when applying the 10 kVp rule in manual mode (50%-28%) compared to AEC mode (36%-23%). Statistical differences for effective dose between several AEC modes were found (p=0.002). The effective dose is lower when using only the right AEC ionization chamber. Considering image quality, there are no statistical differences (p=0.348) between the different AEC modes for images with no lesions. Using a higher kVp value the lgM values will also increase. The lgM values showed significant statistical differences (p=0.000). The image quality scores did not present statistically significant differences (p=0.043) for the images with lesions when comparing manual with AEC modes. Conclusion: In general, the dose is lower in the manual mode. By using the right AEC ionising chamber the effective dose will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the detectability of the lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To estimate rates of non-adherence to telemedicine strategies aimed at treating drug addiction. METHODS A systematic review was conducted of randomized controlled trials investigating different telemedicine treatment methods for drug addiction. The following databases were consulted between May 18, 2012 and June 21, 2012: PubMed, PsycINFO, SciELO, Wiley (The Cochrane Library), Embase, Clinical trials and Google Scholar. The Grading of Recommendations Assessment, Development and Evaluation was used to evaluate the quality of the studies. The criteria evaluated were: appropriate sequence of data generation, allocation concealment, blinding, description of losses and exclusions and analysis by intention to treat. There were 274 studies selected, of which 20 were analyzed. RESULTS Non-adherence rates varied between 15.0% and 70.0%. The interventions evaluated were of at least three months duration and, although they all used telemedicine as support, treatment methods differed. Regarding the quality of the studies, the values also varied from very poor to high quality. High quality studies showed better adherence rates, as did those using more than one technique of intervention and a limited treatment time. Mono-user studies showed better adherence rates than poly-user studies. CONCLUSIONS Rates of non-adherence to treatment involving telemedicine on the part of users of psycho-active substances differed considerably, depending on the country, the intervention method, follow-up time and substances used. Using more than one technique of intervention, short duration of treatment and the type of substance used by patients appear to facilitate adherence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To investigate the factors related to the granting of preliminary court orders [injunctions] in drug litigations. METHODS A retrospective descriptive study of drug lawsuits in the State of Minas Gerais, Southeastern Brazil, was conducted from October 1999 to 2009. The database consists of 6,112 lawsuits, out of which 6,044 had motions for injunctions and 5,167 included the requisition of drugs. Those with more than one beneficiary were excluded, which totaled 5,072 examined suits. The variables for complete, partial, and suppressed motions were treated as dependent and assessed in relation to those that were independent – lawsuits (year, type, legal representation, defendant, court in which it was filed, adjudication time), drugs (level five of the anatomical therapeutic chemical classification), and diseases (chapter of the International Classification of Diseases). Statistical analyses were performed using the Chi-square test. RESULTS Out of the 5,072 lawsuits with injunctions, 4,184 (82.5%) had the injunctions granted. Granting varied from 95.8% of the total lawsuits in 2004 to 76.9% in 2008. Where there was legal representation, granting exceeded 80.0% and in lawsuits without representation, it did not exceed 66.9%. In public civil actions (89.1%), granting was higher relative to ordinary lawsuits (82.8%) and injunctions (80.1%). Federal courts granted only 68.6% of the injunctions, while the state courts granted 84.8%. Diseases of the digestive system and neoplasms received up to 87.0% in granting, while diseases of the nervous system, mental and behavioral disorders, and diseases of the skin and subcutaneous tissue received granting below 78.6% and showed a high proportion of suspended injunctions (10.9%). Injunctions involving paroxetine, somatropin, and ferrous sulfate drugs were all granted, while less than 54.0% of those involving escitalopram, sodium diclofenac, and nortriptyline were granted. CONCLUSIONS There are significant differences in the granting of injunctions, depending on the procedural and clinical variances. Important trends in the pattern of judicial action were observed, particularly, in the reduced granting [of injunctions] over the period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To develop a model for evaluating the efficacy of drug-dispensing service in primary health care. METHODS An efficacy criterion was adopted to determine the level of achievement of the service objectives. The evaluation model was developed on the basis of a literature search and discussions with experts. The applicability test of the model was conducted in 15 primary health care units in the city of Florianópolis, state of Santa Catarina, in 2010, and data were recorded in structured and pretested questionnaires. RESULTS The model developed was evaluated using five dimensions of analysis for analysis. The model was suitable for evaluating service efficacy and helped to identify the critical points of each service dimension. CONCLUSIONS Adaptations to the data collection technique may be required to adjust for the reality and needs of each situation. The evaluation of the drug-dispensing service should promote adequate access to medications supplied through the public health system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To analyze the perception of and motivation for the chronic use of benzodiazepine among older adults. METHODS A qualitative study was conducted on 22 older adults living in Bambuí, MG, Southeastern Brazil, who were taking benzodiazepines and had the clinical and cognitive ability to respond to interview questions. The collected data were analyzed on the basis of the “signs, meanings, and actions” model. RESULTS The main reasons pointed out for the use of benzodiazepines were “nervousness”, “sleep problems”, and “worry” due to family and financial problems, everyday problems, and existential difficulties. None of the interviewees said that they used benzodiazepines in a dose higher than that recommended or had been warned by health professionals about any risks of their continuous use. Different strategies were used to obtain the prescription for the medication, and any physician would prescribe it, indicating that a bond was established with the drug and not with the health professional or healthcare service. Obtaining and consuming the medication turned into a crucial issue because benzodiazepine assumes the status of an essential food, which leads users to not think but sleep. It causes a feeling of relief from their problems such as awareness of human finitude and fragility, existential difficulties, and family problems. CONCLUSIONS Benzodiazepine assumes the characteristics of polyvalence among older adults, which extrapolate specific clinical indications, and of essentiality to deal with life’s problems in old age. Although it relieves the “nerves”, the chronic use of benzodiazepines buffers suffering and prevents older adults from going through the suffering. This shows important difficulties in the organization and planning of strategies that are necessary for minimizing the chronic use in this population.