877 resultados para direct


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a measurement of the mass difference between t and t̄ quarks in lepton+jets final states of tt̄ events in 1fb-1 of data collected with the D0 detector from Fermilab Tevatron Collider pp̄ collisions at s=1.96TeV. The measured mass difference of 3.8±3.7GeV is consistent with the equality of t and t̄ masses. This is the first direct measurement of a mass difference between a quark and its antiquark partner. © 2009 The American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The retention phase is initiated after orthodontic treatment completion to prevent orthodontic relapse. There are several techniques, direct and indirect, available for placing bonded lingual retainers, but none of them is considered as a standard clinical protocol. The best choice should be the association of simplicity and efficiency. This article presents a practical method sequence for fixation of the lingual retainer before direct bonding. © 2009 Elsevier Ltd and the Japanese Orthodontic Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Although direct bonding takes up less clinical time and ensures increased preservation of gingival health, the banding of molar teeth is still widespread nowadays. It would therefore be convenient to devise methods capable of increasing the efficiency of this procedure, notably for teeth subjected to substantial masticatory impact, such as molars. This study was conducted with the purpose of evaluating whether direct bonding would benefit from the application of an additional layer of resin to the occlusal surfaces of the tube/tooth interface. Methods: A sample of 40 mandibular third molars was selected and randomly divided into two groups: Group 1 - Conventional direct bonding, followed by the application of a layer of resin to the occlusal surfaces of the tube/tooth interface, and Group 2 - Conventional direct bonding. Shear bond strength was tested 24 hours after bonding with the aid of a universal testing machine operating at a speed of 0.5mm/min. The results were analyzed using the independent t-test. Results: The shear bond strength tests yielded the following mean values: 17.08 MPa for Group 1 and 12.60 MPa for Group 2. Group 1 showed higher statistically significant shear bond strength than Group 2. Conclusions: The application of an additional layer of resin to the occlusal surfaces of the tube/tooth interface was found to enhance bond strength quality of orthodontic buccal tubes bonded directly to molar teeth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnesium complex hydrides as Mg 2FeH 6 are interesting phases for hydrogen storage in the solid state, mainly due to its high gravimetric and volumetric densities of H2. However, the synthesis of this hydride is not trivial because the intermetallic phase Mg2Fe does not exist and Mg and Fe are virtually immiscible under equilibrium conditions. In this study, we have systematically studied the influence of the most important processing parameters in reactive milling under hydrogen (RM) for Mg 2FeH 6 synthesis: milling time, ball-to-powder weight ratio (BPR), hydrogen pressure and type of mill. Low cost 2Mg-Fe mixtures were used as raw materials. An important control of the Mg 2FeH 6 direct synthesis by RM was attained. In optimized combinations of the processing parameters, very high proportions of the complex hydride could be obtained. © (2011) Trans Tech Publications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a climatic and statistical analysis of global, direct horizontal and diffuse radiation from a database of solar radiation measured from 1996 to 2006 in the city of Botucatu, SP, Brazil. Variation intervals of hourly and daily irradiation, annual mean 〈H̄G〉, 〈H̄bh〉 and 〈H̄d〉 irradiation, monthly mean 〈H̄G〉, 〈H̄ bh〉 and 〈H̄d〉 irradiation and monthly mean 〈K̄t〉, 〈K̄bh〉 and 〈K̄d〉 fractions were determined. Results showed that values of hourly and daily annual mean irradiation were as follows: 〈H̄G〉=1.49MJ/m2 and 〈H̄ G〉=17.74MJ/m2; 〈H̄bh〉=0. 90MJ/m2 and 〈H̄bh〉=10.33MJ/m2 and 〈H̄d〉=0.57 MJ/m2 and 〈H̄d〉=7.09MJ/m2, respectively. Variation intervals of hourly monthly mean irradiation were as follows: 〈H̄G〉 ranged from 1.65MJ/m2 in March to 1.16MJ/m2 in June; 〈H̄bh〉 ranged from 1.06MJ/m2 in April to 0.79MJ/m2 in June, and 〈H̄d〉 ranged from 0.70MJ/m2 in January to 0.37MJ/m2 in June and July. Similarly, daily 〈H̄ G〉 irradiation ranged from 21.35MJ/m2 in November to 12.94MJ/m2 in June; 〈H̄bh〉 ranged from 11.83MJ/m2 in April to 8.49MJ/m2 in June, and 〈H̄d〉 ranged from 10.29MJ/m2 in December to 4.38MJ/m2 in June. Variation intervals of hourly monthly mean fractions were as follows: 〈K̄t〉 ranged from 43.5% in January to 54.2% in April; 〈K̄bh〉 ranged from 33.6% in January to 58.0% in April and 〈K̄d〉 ranged from 66.4% in January to 42.0% in April. In the same way, daily 〈K̄ t〉 fractions ranged from 45.5% in January to 59.8% in August; 〈K̄bh〉 ranged from 38.9% in January to 62.0% in August and 〈K̄d〉 ranged from 61.1% in January to 37.7% in July.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigates the promoting effect of PtSnIr/C (1:1:1) electrocatalyst anode, prepared by polymeric precursor method, on the ethanol oxidation reaction in a direct ethanol fuel cell (DEFC). All of the materials used were 20% metal m/m on carbon. X-ray photoelectron spectroscopy (XPS) analysis showed the presence of Pt, PtOH 2, PtO 2, SnO 2 and IrO 2 at the electrocatalyst surface, indicating a possible decorated particle structure. X-ray diffractometry (XRD) analysis indicated metallic Pt and Ir as well as the formation of an alloy with Sn. Using the PtSnIr/C electrocatalyst prepared here with two times lower loading of Pt than PtSn/C E-tek electrocatalyst, it was possible to obtain the same maximum power density found for the commercial material. The main reaction product was acetic acid probably due to the presence of oxides, in this point the bifunctional mechanism is predominant, but an electronic effect should not be discarded. © 2012 Sociedade Brasileira de Química.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical expansion of the disturbing function arising from direct planetary perturbations on the motion of satellites is derived. As a Fourier series, it allows the investigation of the secular effects of these direct perturbations, as well as of every argument present in the perturbation. In particular, we construct an analytical model describing the evection resonance between the longitude of pericenter of the satellite orbit and the longitude of a planet, and study briefly its dynamic. The expansion developed in this paper is valid in the case of planar and circular planetary orbits, but not limited in eccentricity or inclination of the satellite orbit. © 2012 Springer Science+Business Media Dordrecht.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A mercury film electrode was used to determine direct and simultaneously Pb(II) (at -410 mV) and Cu(II) (at -100 mV) in biodiesel by anodic stripping voltammetry. A linear response was obtained for Pb(II) and Cu(II) in the 2.00 × 10-8-1.00 × 10-7 mol L-1 concentration range and detection limits were 2.91 × 10-9 mol L-1 and 4.69 × 10-9 mol L-1 for Pb(II) and Cu(II), respectively, with recovery around of 100.0%. © 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography