827 resultados para deep bed filtration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pupunha (Guilielma speciosa) is the fruit of a palm tree typical of the Brazilian Northern region, whose stem is used as a source of heart of palm. The fruit, which is about 65% pulp, is a source of oil and carotenes. In the present work, an analysis of the kinetics of supercritical extraction of oil from the pupunha pulp is presented. Carbon dioxide was used as solvent. The extractions were carried out at 25 MPa and 323 K and 30 MPa and 318 K. The chemical composition of the extracts in terms of fatty acids was determined by gas chromatography. The amount of oleic acid, a saturated fatty acid, in the CO2 extracts was larger than that in the extract obtained with hexane. The overall extraction curves were modeled using the single-parameter model proposed in the literature to describe the desorption of toluene from activated coal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Pneumoperitoneum during laparoscopy results in transient oliguria and decreased glomerular filtration and renal blood flow. The presence of oliguria and elevated serum creatinine is suggestive of acute renal injury. Serum cystatin C has been described as a new marker for the detection of this type of injury. In this study, our aim was to compare the glomerular filtration rate estimated using cystatin C levels with the rate estimated using serum creatinine in patients with normal renal function who were undergoing laparoscopic surgery. METHODS: In total, 41 patients undergoing laparoscopic cholecystectomy or hiatoplasty were recruited for the study. Blood samples were collected at three time intervals: first, before intubation (T1); second, 30 minutes after the establishment of pneumoperitoneum (T2); and third, 30 minutes after deflation of the pneumoperitoneum (T3). These blood samples were then analyzed for serum cystatin C, creatinine, and vasopressin. The Larsson formula was used to calculate the glomerular filtration rate based on the serum cystatin C levels, and the Cockcroft-Gault formula was used to calculate the glomerular filtration rate according to the serum creatinine levels. RESULTS: Serum cystatin C levels increased during the study (T1 = T2T3; p<0.05). The calculated eGlomerular filtration rate-Larsson decreased, whereas the eGlomerular filtration rate-Cockcroft-Gault increased. There was no correlation between cystatin C and serum creatinine. Additionally, Pearson's analysis showed a better correlation between serum cystatin C and the eGlomerular filtration rate than between serum creatinine and the eGlomerular filtration rate. CONCLUSION: This study demonstrates that serum cystatin C is a more sensitive indicator of changes in the glomerular filtration rate than serum creatinine is in patients with normal renal function who are undergoing laparoscopic procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O processo de recanalização das veias dos membros inferiores, após um episódio de trombose venosa profunda aguda em pacientes anticoagulados com heparina e inibidores da vitamina K, faz parte da evolução natural da remodelagem do trombo venoso. Esse complexo processo de remodelagem envolve a adesão do trombo à parede da veia, à resposta inflamatória da parede do vaso, levando à organização e subsequente contração do trombo, à neovascularização e à lise espontânea de áreas no interior do trombo. A presença de fluxo arterial espontâneo em veias com trombose recanalizada tem sido descrita como secundária à neovascularização e se caracteriza pelo desenvolvimento de fluxo com padrão de fístulas arteriovenosas, identificadas por meio de mapeamento dúplex colorido. Nesta revisão, são discutidos alguns aspectos controversos da história natural da trombose venosa profunda, para uma melhor compreensão da sua evolução e do seu impacto sobre a doença venosa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE:The purpose of this study was to evaluate the long term clinical and ultrasonographic outcomes of thrombophilic patients with deep venous thrombosis (DVT).METHOD:Cohort study, retrospective case-control with cross-sectional analysis. Thirty-nine thrombophilic patients and 25 non-thrombophilic patients were assessed 76.3 ± 45.8 months after diagnosis. Demographic and family data were collected, as well as data from clinical and therapeutic progress, and physical and ultrasound examinations of the limbs were performed. Groups were matched for age and gender and the variables studied were compared across groups.RESULTS:Deep venous thrombosis was more frequent in women. The most common thrombophilias were antiphospholipid syndrome and factor V Leiden mutation. There was no difference between groups in terms of the number of pregnancies or miscarriages and the majority of women did not become pregnant after DVT. Non-spontaneous DVT prevailed. Proximal DVT and DVT of the left lower limb were more frequent, and the main risk factor was use of oral contraceptives. All patients were treated with anticoagulation. There was a higher frequency of pulmonary embolism in non-thrombophilic patients. Most patients considered themselves to have a normal life after DVT and reported wearing elastic stockings over at least 2 years. Seventy-one percent of patients had CEAP > 3, with no difference between groups. Deep venous reflux was more frequent in thrombophilic patients.CONCLUSION:There were no significant differences between groups with respect to most of the variables studied, except for a higher frequency of pulmonary embolism in non-thrombophilic patients and greater frequency of deep venous reflux in thrombophilic patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The multi stage filtration (MSF) is an alternative that permits to enlarge the spectrum of application of the slow sand filtration as for the effluent quality and run duration. In this research the use of MSF technology associated to a granular activated carbon (GAC) column as polishing mechanism of the final effluent was evaluated; in the slow sand filters GAC was used as an intermediate layer and non-woven synthetic fabrics were utilized as a first layer of the filter media. Five different tests were conducted, where the systems subjected to the treatment were: water from the Ipe Lake (Ilha Solteira, Sao Paulo, Brazil); water from the lake with water from a recreational fish pond; water from the lake with a phytoplankton and cyanobacteria overload simulation, with and without the use of the pre-filters as a stage of the treatment. The synthetic fabrics and GAC use resulted in the best turbidity removal and an efficient apparent and true color removal; in spite that the polishing columns reported similar results for those parameters. The utilization of GAC as an intermediate layer contributed to a better organic matter removal and the fabrics improved chlorophyll-a removal. The pre-filtration columns made an efficient algae and cyanobacteria removal, a function that was completed by the filters and reached >98% efficiency. The synthetic non-woven fabrics and GAC inclusion in MSF operation improved performance of this technology with ease of application and operation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to describe the dynamics of monochromatic surface waves in deep water, we derive a nonlinear and dispersive system of equations for the free surface elevation and the free surface velocity from the Euler equations in infinite depth. From it, and using a multiscale perturbative method, an asymptotic model for small wave steepness ratio is derived. The model is shown to be completely integrable. The Lax pair, the first conserved quantities as well as the symmetries are exhibited. Theoretical and numerical studies reveal that it supports periodic progressive Stokes waves which peak and break in finite time. Comparison between the limiting wave solution of the asymptotic model and classical results is performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Duplex ultrasound scanning (DUS) is the method of choice for diagnosis of deep vein thrombosis (DVT). However, only a few studies have performed prospective serial DUS after an acute episode of DVT to assess its evolution. This study aimed to report our experience using DUS combined with a thrombosis score (TS) and a newly proposed vein diameter variation index (VDVI) to evaluate the rate of resolution of DVT by assessing and quantifying the early stages of vein recanalization in proximal vein segments within 6 months after an episode of acute lower extremity DVT.Methods: Twelve patients with first episode of acute lower extremity DVT confirmed by DUS as occurring in <= 10 days after the onset of venous thrombosis symptoms were followed up prospectively for 6 months. TS and VDVI were calculated at 1, 3, and 6 months to assess vein recanalization. Intra-thrombus arteriovenous fistula formation was also investigated and related to the recanalization process.Results: Seven (58%) women were included, with a total cohort median age of 53.5 +/- 19 years. The left lower extremity was affected in 7 (58%) patients. DVT was diagnosed in 55 proximal vein segments. All patients had proximal DVT, with involvement of the external iliac, femoral, and popliteal veins. After 6 months, there was a significant decrease in TS and increase in VDVI (P < 0.001) in all proximal vein segments assessed, indicating thrombus regression. The more distal the DVT was, the faster was the VDVI increase, with most popliteal veins being recanalized at 3 months (P < 0.001). Intra-thrombus arteriovenous fistula was identified in 50% of patients at 1 month while on anticoagulation.Conclusions: The combined use of two different DUS-based assessment tools, TS and the proposed VDVI, provided an effective method to prospectively assess vein recanalization rates after an episode of acute lower extremity DVT in this series of patients and may allow a correct evaluation of DVT and its resolution or progression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)