911 resultados para WEANING WEIGHT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The safety of our food is an essential requirement of society. One well-recognised threat is that of chemical contamination of our food, where low-molecular-weight compounds such as biotoxins, drug residues and pesticides are present. Low-cost, rapid screening procedures are sought to discriminate the suspect samples from the population, thus selecting only these to be forwarded for confirmatory analysis. Many biosensor assays have been developed as screening tools in food contaminant analysis, but these tend to be electrochemical, fluorescence or surface plasmon resonance based. An alternative approach is the use of biolayer interferometry, which has become established in drug discovery and life science studies but is only now emerging as a potential tool in the analysis of food contaminants. A biolayer interferometry biosensor was assessed using domoic acid as a model compound. Instrument repeatability was tested by simultaneously producing six calibration curves showing replicate repeatability (n = 2) ranging from 0.1 to 6.5 % CV with individual concentration measurements (n = 12) ranging from 4.3 to 9.3 % CV, giving a calibration curve midpoint of 7.5 ng/ml (2.3 % CV (n = 6)). Reproducibility was assessed by producing three calibration curves on different days, giving a midpoint of 7.5 ng/ml (3.4 %CV (n = 3)). It was further shown, using assay development techniques, that the calibration curve midpoint could be adjusted from 10.4 to 1.9 ng/ml by varying assay parameters before the simultaneous construction of three calibration curves in matrix and buffer. Sensitivity of the assay compared favourably with previously published biosensor data for domoic acid. © 2013 Springer-Verlag Berlin Heidelberg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pregnancy and the postpartum period is a time of increased vulnerability for retention of excess body fat in women. Breastfeeding (BF) has been shown to have many health benefits for both mother and baby; however, its role in postpartum weight management is unclear. Our aim was to systematically review and critically appraise the literature published to date in relation to the impact of BF on postpartum weight change, weight retention and maternal body composition. Electronic literature searches were carried out using MEDLINE, EMBASE, PubMed, Web of Science, BIOSIS, CINAHL and British Nursing Index. The search covered publications up to 12 June 2012 and included observational studies (prospective and retrospective) carried out in BF mothers (either exclusively or as a subgroup), who were 2 years postpartum and with a body mass index (BMI) >18.5 kg m(-2), with an outcome measure of change in weight (including weight retention) and/or body composition. Thirty-seven prospective studies and eight retrospective studies were identified that met the selection criteria; studies were stratified according to study design and outcome measure. Overall, studies were heterogeneous, particularly in relation to sample size, measurement time points and in the classification of BF and postpartum weight change. The majority of studies reported little or no association between BF and weight change (n=27, 63%) or change in body composition (n=16, 89%), although this seemed to depend on the measurement time points and BF intensity. However, of the five studies that were considered to be of high methodological quality, four studies demonstrated a positive association between BF and weight change. This systematic review highlights the difficulties of examining the association between BF and weight management in observational research. Although the available evidence challenges the widely held belief that BF promotes weight loss, more robust studies are needed to reliably assess the impact of BF on postpartum weight management.International Journal of Obesity advance online publication, 20 August 2013; doi:10.1038/ijo.2013.132.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background; Weaning from mechanical ventilation is influenced by patient, clinician, and organizational factors.

Objective: To identify factors that may influence weaning and adoption of weaning strategies and tools, clinicians’ perceptions of weaning strategies, and weaning experiences of patients and patients’ families.

Method: A scoping review of indexed and nonindexed publications (1990–2012) was done. Qualitative studies of health care providers, patients, and patients’ families involved in weaning were included. Two investigators independently screened 8350 publications and extracted data from 43 studies. Study themes were content analyzed to identify common categories and themes within the categories.

Results: The study sample consisted of nurses in 15 studies, nurses and patients in 1 study, various health care providers in 11, patients in 10, and physicians in 4. Categories identified were as follows: for nurses, role or scope of practice, informing decision making, and influence on weaning outcome; for health care providers, factors influencing weaning decisions or use of protocols, role or scope of practice related to weaning, and organizational structure or practice environment; for patients, experience of mechanical ventilation and weaning, experience of the intensive care environment, psychological phenomena, and enabling success in weaning; and for physicians, tools or factors to facilitate weaning decisions and perceptions of nurses’ role and scope of practice.

Conclusions: Important issues identified were perceived importance of interprofessional collaboration and communication, need to combine subjective knowledge of the patient with objective clinical data, balancing of weaning systematization with individual needs, and appreciation of the physical and psychological work of weaning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The aim of this study was to examine the relationship between physical activity and wellbeing in children, and to further explore the extent to which this may vary by gender and weight status. Method: A representative sample of 1424 9- to 11-year-olds completed a self-report measure of physical activity, the Child Health and Illness Profile, KIDSCREEN, and a self-esteem scale. Body Mass Index (BMI) measurements were also obtained. Results: 24% of children achieved the recommended level of 60 minutes of moderate-tovigorous intensity physical activity (MVPA) per day, with more boys than girls achieving this level. Children achieving the recommended level of MVPA scored significantly higher on measures of the Child Health and Illness Profile (F(5, 1354) = 5.03; P < .001), KIDSCREEN (F(3, 1298) = 4.68; P = .003), and self-esteem (F(1,1271) = 18.73; P = .003) than less active children although the effect sizes were small (ηp2 ≈ .01). Substantial gender differences in wellbeing were found reflecting gender specific behaviors and socialization. Weight status had negligible influence on wellbeing. Conclusions: Children who meet the recommended guidelines of MVPA were more likely to have better wellbeing. When attempting to raise children’s physical activity levels consideration should be given to the specific relationships between wellbeing and physical activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The postpartum period is a vulnerable time for excess weight retention, particularly for the increasing number of women who are overweight at the start of their pregnancy and subsequently find it difficult to lose additional weight gained during pregnancy. Although postpartum weight management interventions play an important role in breaking this potentially vicious cycle of weight gain, the effectiveness of such interventions in breastfeeding women remains unclear. Our aim was to systematically review the literature about the effectiveness of weight management interventions in breastfeeding women.

Methods: Seven electronic databases were searched for eligible papers. Intervention studies included were carried out exclusively in breastfeeding mothers, ≤2 years postpartum and with a body mass index greater than 18.5 kg/m2, with an outcome measure of change in weight and/or body composition.

Results: Six studies met the selection criteria, and were stratified according to the type of intervention and outcome measures. Despite considerable heterogeneity among studies, the dietary-based intervention studies appeared to be the most efficacious in promoting weight loss; however, few studies were tailored toward the needs of breastfeeding women.

Conclusions: Weight management interventions which include an energy-restricted diet may play a key role in successful postpartum weight loss for breastfeeding mothers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: This is an update of a review last published in Issue 5, 2010, of The Cochrane Library. Reducing weaning time is desirable in minimizing potential complications from mechanical ventilation. Standardized weaning protocols are purported to reduce time spent on mechanical ventilation. However, evidence supporting their use in clinical practice is inconsistent. Objectives: The first objective of this review was to compare the total duration of mechanical ventilation of critically ill adults who were weaned using protocols versus usual (non-protocolized) practice.The second objective was to ascertain differences between protocolized and non-protocolized weaning in outcomes measuring weaning duration, harm (adverse events) and resource use (intensive care unit (ICU) and hospital length of stay, cost).The third objective was to explore, using subgroup analyses, variations in outcomes by type of ICU, type of protocol and approach to delivering the protocol (professional-led or computer-driven). Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library Issue 1, 2014), MEDLINE (1950 to January 2014), EMBASE (1988 to January 2014), CINAHL (1937 to January 2014), LILACS (1982 to January 2014), ISI Web of Science and ISI Conference Proceedings (1970 to February 2014), and reference lists of articles. We did not apply language restrictions. The original search was performed in January 2010 and updated in January 2014.Selection criteriaWe included randomized controlled trials (RCTs) and quasi-RCTs of protocolized weaning versus non-protocolized weaning from mechanical ventilation in critically ill adults. Data collection and analysis: Two authors independently assessed trial quality and extracted data. We performed a priori subgroup and sensitivity analyses. We contacted study authors for additional information. Main results: We included 17 trials (with 2434 patients) in this updated review. The original review included 11 trials. The total geometric mean duration of mechanical ventilation in the protocolized weaning group was on average reduced by 26% compared with the usual care group (N = 14 trials, 95% confidence interval (CI) 13% to 37%, P = 0.0002). Reductions were most likely to occur in medical, surgical and mixed ICUs, but not in neurosurgical ICUs. Weaning duration was reduced by 70% (N = 8 trials, 95% CI 27% to 88%, P = 0.009); and ICU length of stay by 11% (N = 9 trials, 95% CI 3% to 19%, P = 0.01). There was significant heterogeneity among studies for total duration of mechanical ventilation (I2 = 67%, P < 0.0001) and weaning duration (I2 = 97%, P < 0.00001), which could not be explained by subgroup analyses based on type of unit or type of approach. Authors' conclusions: There is evidence of reduced duration of mechanical ventilation, weaning duration and ICU length of stay with use of standardized weaning protocols. Reductions are most likely to occur in medical, surgical and mixed ICUs, but not in neurosurgical ICUs. However, significant heterogeneity among studies indicates caution in generalizing results. Some study authors suggest that organizational context may influence outcomes, however these factors were not considered in all included studies and could not be evaluated. Future trials should consider an evaluation of the process of intervention delivery to distinguish between intervention and implementation effects. There is an important need for further development and research in the neurosurgical population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IntroductionAutomated weaning systems may improve adaptation of mechanical support for a patient’s ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. Our objective was to compare mechanical ventilator weaning duration for critically ill adults and children when managed with automated systems versus non-automated strategies. Secondary objectives were to determine differences in duration of ventilation, intensive care unit (ICU) and hospital length of stay (LOS), mortality, and adverse events.MethodsElectronic databases were searched to 30 September 2013 without language restrictions. We also searched conference proceedings; trial registration websites; and article reference lists. Two authors independently extracted data and assessed risk of bias. We combined data using random-effects modelling.ResultsWe identified 21 eligible trials totalling 1,676 participants. Pooled data from 16 trials indicated that automated systems reduced the geometric mean weaning duration by 30% (95% confidence interval (CI) 13% to 45%), with substantial heterogeneity (I2 = 87%, P <0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not with surgical populations or using other systems. Automated systems reduced ventilation duration with no heterogeneity (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of effect on mortality, hospital LOS, reintubation, self-extubation and non-invasive ventilation following extubation. Automated systems reduced prolonged mechanical ventilation and tracheostomy. Overall quality of evidence was high.ConclusionsAutomated systems may reduce weaning and ventilation duration and ICU stay. Due to substantial trial heterogeneity an adequately powered, high quality, multi-centre randomized controlled trial is needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Automated closed loop systems may improve adaptation of mechanical support for a patient's ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. This review was originally published in 2013 with an update published in 2014. Objectives The primary objective for this review was to compare the total duration of weaning from mechanical ventilation, defined as the time from study randomization to successful extubation (as defined by study authors), for critically ill ventilated patients managed with an automated weaning system versus no automated weaning system (usual care). Secondary objectives for this review were to determine differences in the duration of ventilation, intensive care unit (ICU) and hospital lengths of stay (LOS), mortality, and adverse events related to early or delayed extubation with the use of automated weaning systems compared to weaning in the absence of an automated weaning system. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 8); MEDLINE (OvidSP) (1948 to September 2013); EMBASE (OvidSP) (1980 to September 2013); CINAHL (EBSCOhost) (1982 to September 2013); and the Latin American and Caribbean Health Sciences Literature (LILACS). Relevant published reviews were sought using the Database of Abstracts of Reviews of Effects (DARE) and the Health Technology Assessment Database (HTA Database). We also searched the Web of Science Proceedings; conference proceedings; trial registration websites; and reference lists of relevant articles. The original search was run in August 2011, with database auto-alerts up to August 2012. Selection criteria We included randomized controlled trials comparing automated closed loop ventilator applications to non-automated weaning strategies including non-protocolized usual care and protocolized weaning in patients over four weeks of age receiving invasive mechanical ventilation in an ICU. Data collection and analysis Two authors independently extracted study data and assessed risk of bias. We combined data in forest plots using random-effects modelling. Subgroup and sensitivity analyses were conducted according to a priori criteria. Main results We included 21 trials (19 adult, two paediatric) totaling 1676 participants (1628 adults, 48 children) in this updated review. Pooled data from 16 eligible trials reporting weaning duration indicated that automated closed loop systems reduced the geometric mean duration of weaning by 30% (95% confidence interval (CI) 13% to 45%), however heterogeneity was substantial (I2 = 87%, P < 0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not in surgical populations or using other systems. Automated closed loop systems reduced the duration of ventilation (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of an effect on mortality rates, hospital LOS, reintubation rates, self-extubation and use of non-invasive ventilation following extubation. Prolonged mechanical ventilation > 21 days and tracheostomy were reduced in favour of automated systems (relative risk (RR) 0.51, 95% CI 0.27 to 0.95 and RR 0.67, 95% CI 0.50 to 0.90 respectively). Overall the quality of the evidence was high with the majority of trials rated as low risk. Authors' conclusions Automated closed loop systems may result in reduced duration of weaning, ventilation and ICU stay. Reductions are more likely to occur in mixed or medical ICU populations. Due to the lack of, or limited, evidence on automated systems other than Smartcare/PS™ and Adaptive Support Ventilation no conclusions can be drawn regarding their influence on these outcomes. Due to substantial heterogeneity in trials there is a need for an adequately powered, high quality, multi-centre randomized controlled trial in adults that excludes 'simple to wean' patients. There is a pressing need for further technological development and research in the paediatric population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapid immunoanalytical screening of food and environmental samples for small molecular weight (hapten) biotoxin contaminations requires the production of antibody reagents that possess the requisite sensitivity and specificity. To date animal-derived polyclonal (pAb) and monoclonal (mAb) antibodies have provided the binding element of the majority of these assays but recombinant antibodies (rAb) isolated from in vitro combinatorial phage display libraries are an exciting alternative due to (1) circumventing the need for experimental animals, (2) speed of production in commonly used in vitro expression systems and (3) subsequent molecular enhancement of binder performance. Short chain variable fragments (scFv) have been the most commonly employed rAb reagents for hapten biotoxin detection over the last two decades but antibody binding fragments (Fab) and single domain antibodies (sdAb) are increasing in popularity due to increased expression efficiency of functional binders and superior resistance to solvents. rAb-based immunochromatographic assays and surface plasmon resonance (SPR) biosensors have been reported to detect sub-regulatory levels of fungal (mycotoxins), marine (phycotoxins) and aquatic biotoxins in a wide range of food and environmental matrices, however this technology has yet to surpass the performances of the equivalent mAb- and pAb-based formats. As such the full potential of rAb technology in hapten biotoxin detection has yet to be achieved, but in time the inherent advantages of engineered rAb are set to provide the next generation of ultra-high performing binder reagents for the rapid and specific detection of hapten biotoxins.

Relevância:

20.00% 20.00%

Publicador: