999 resultados para Verification Bias


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Detrital studies that utilize zircon U–Pb geochronology and fission-track (FT) thermochronometry are subject to a range of potential sources of bias that should be properly evaluated and minimized. Some of them are common to any single-grain mineral analysis (e.g., variable bedrock mineral fertility, hydraulic sorting during transport, selective grain loss during sample processing), whereas others are intrinsic to zircon, and are related to radiation damage and age discordance. In this article, we quantify the impact of intrinsic bias on detrital studies thanks to the analysis of modern detritus shed from the European Alps, and illustrate the general implications on geological interpretations. We show that detrital zircon U–Pb age distributions based on statistically robust datasets are highly reproducible and representative of the parent bedrock ages in the catchment. Arbitrary or selective removal of discordant grain ages can be minimized by using the Kolmogorov–Smirnov test to identify an appropriate cutoff level. Loss of metamict (α-damaged) zircon has a minor impact on data representativeness, and is mainly controlled by regional metamorphism rather than by mechanical abrasion during river transport. Zircon FT grain-age distributions were found to have poor reproducibility, although age spectra are consistent with bedrock data. However, unlike the U–Pb datasets, U-rich zircon grains (> 1000 ppm) are systematically missed, and undatable grains may exceed 50%. We identify two major sources of distribution bias specific to zircon FT datasets: (i) sediment sources dominated by U-rich zircon grains are markedly underrepresented in the detrital record, because such grains often have uncountable high densities of fission tracks (“U concentration bias”); (ii) sediment sources that shed zircon grains with high levels of α-damage are underrepresented, because these grains are lost during chemical etching for FT revelation (“etching bias”). In the case of multimethod dating on the same grains (e.g., FT and U–Pb double dating), bias affecting detrital zircon FT dating propagates to the entire dataset. These effects may not impact on exhumation-rate studies that utilize the youngest grain ages (i.e., lag-time approach). However, they represent a limiting factor for conventional provenance studies, and generally preclude application of zircon FT dating to sediment budget calculations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The RPC developed a new phantom to ensure comparable and consistent radiation administration in spinal radiosurgery clinical trials. This study assessed the phantom’s dosimetric and anatomic utility. The ‘spine phantom’ is a water filled thorax with anatomy encountered in spinal radiosurgery: target volume, vertebral column, spinal canal, esophagus, heart, and lungs. The dose to the target volume was measured with axial and sagittal planes of radiochromic film and thermoluminescent dosimeters (TLD). The dose distributions were measured with the radiochromic film calibrated to the absolute dose measured by the TLD. Four irradiations were administered: a four angle box plan, a seven angle conformal plan, a seven angle IMRT plan, and a nine angle IMRT plan (denoted as IMRT plan #1 and plan #2, respectively). In each plan, at least 95% of the defined tumor volume received 8 Gy. For each irradiation the planned and administered dose distributions were registered via pinpricks, and compared using point dose measurements, dose profiles, isodose distributions, and gamma analyses. Based on previous experience at the RPC, a gamma analysis was considering passing if greater than 95% of pixels passed the criteria of 5% dose difference and 3 mm distance-to-agreement. Each irradiation showed acceptable agreement in the qualitative assessments and exceeded the 95% passing rate at the 5% / 3 mm criteria, except IMRT plan #1, which was determined to have been poorly localized during treatment administration. The measured and planned dose distributions demonstrated acceptable agreement at the 5% / 3 mm criteria, and the spine phantom was determined to be a useful tool for the remote assessment of an institution’s treatment planning and dose delivery regimen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Radiological Physics Center (RPC) provides heterogeneous phantoms that are used to evaluate radiation treatment procedures as part of a comprehensive quality assurance program for institutions participating in clinical trials. It was hypothesized that the existing RPC heterogeneous thorax phantom can be modified to assess lung tumor proton beam therapy procedures involving patient simulation, treatment planning, and treatment delivery, and could confirm agreement between the measured dose and calculated dose within 5%/3mm with a reproducibility of 5%. The Hounsfield Units (HU) for lung equivalent materials (balsa wood and cork) was measured using a CT scanner. The relative linear stopping power (RLSP) of these materials was measured. The linear energy transfer (LET) of Gafchromic EBT2 film was analyzed utilizing parallel and perpendicular orientations in a water tank and compared to ion chamber readings. Both parallel and perpendicular orientations displayed a quenching effect underperforming the ion chamber, with the parallel orientation showing an average 31 % difference and the perpendicular showing an average of 15% difference. Two treatment plans were created that delivered the prescribed dose to the target volume, while achieving low entrance doses. Both treatment plans were designed using smeared compensators and expanded apertures, as would be utilized for a patient in the clinic. Plan 1a contained two beams that were set to orthogonal angles and a zero degree couch kick. Plan 1b utilized two beams set to 10 and 80 degrees with a 15 degree couch kick. EBT2 film and TLD were inserted and the phantom was irradiated 3 times for each plan. Both plans passed the criteria for the TLD measurements where the TLD values were within 7% of the dose calculated by Eclipse. Utilizing the 5%/3mm criteria, the 3 trial average of overall pass rate was 71% for Plan 1a. The 3 trial average for the overall pass rate was 76% for Plan 1b. The trials were then analyzed using RPC conventional lung treatment guidelines set forth by the RTOG: 5%/5mm, and an overall pass rate of 85%. Utilizing these criteria, only Plan 1b passed for all 3 trials, with an average overall pass rate of 89%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The successful management of cancer with radiation relies on the accurate deposition of a prescribed dose to a prescribed anatomical volume within the patient. Treatment set-up errors are inevitable because the alignment of field shaping devices with the patient must be repeated daily up to eighty times during the course of a fractionated radiotherapy treatment. With the invention of electronic portal imaging devices (EPIDs), patient's portal images can be visualized daily in real-time after only a small fraction of the radiation dose has been delivered to each treatment field. However, the accuracy of human visual evaluation of low-contrast portal images has been found to be inadequate. The goal of this research is to develop automated image analysis tools to detect both treatment field shape errors and patient anatomy placement errors with an EPID. A moments method has been developed to align treatment field images to compensate for lack of repositioning precision of the image detector. A figure of merit has also been established to verify the shape and rotation of the treatment fields. Following proper alignment of treatment field boundaries, a cross-correlation method has been developed to detect shifts of the patient's anatomy relative to the treatment field boundary. Phantom studies showed that the moments method aligned the radiation fields to within 0.5mm of translation and 0.5$\sp\circ$ of rotation and that the cross-correlation method aligned anatomical structures inside the radiation field to within 1 mm of translation and 1$\sp\circ$ of rotation. A new procedure of generating and using digitally reconstructed radiographs (DRRs) at megavoltage energies as reference images was also investigated. The procedure allowed a direct comparison between a designed treatment portal and the actual patient setup positions detected by an EPID. Phantom studies confirmed the feasibility of the methodology. Both the moments method and the cross-correlation technique were implemented within an experimental radiotherapy picture archival and communication system (RT-PACS) and were used clinically to evaluate the setup variability of two groups of cancer patients treated with and without an alpha-cradle immobilization aid. The tools developed in this project have proven to be very effective and have played an important role in detecting patient alignment errors and field-shape errors in treatment fields formed by a multileaf collimator (MLC). ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hepatocellular carcinoma is the main liver-related cause of death in patients with compensated cirrhosis. The early phases are asymptomatic and the prognosis is poor, which makes prevention essential. We propose that non-selective beta-blockers decrease the incidence and growth of hepatocellular carcinoma via a reduction of the inflammatory load from the gut to the liver and inhibition of angiogenesis. Due to their effect on the portal pressure, non-selective beta-blockers are used for prevention of esophageal variceal bleeding. Recently, non-hemodynamic effects of beta-blockers have received increasing attention. Blockage of β-adrenoceptors in the intestinal mucosa and gut lymphatic tissue together with changes in type and virulence of the intestinal microbiota lead to reduced bacterial translocation and a subsequent decrease in the portal load of pathogen-associated molecular patterns. This may reduce hepatic inflammation. Blockage of β-adrenoceptors also decrease angiogenesis by inhibition of vascular endothelial growth factors. Because gut-derived inflammation and neo-angiogenesis are important in hepatic carcinogenesis, non-selective beta-blockers can potentially reduce the development and growth of hepatocellular carcinoma. Rodent and in vitro studies support the hypothesis, but clinical verification is needed. Different study designs may be considered. The feasibility of a randomized controlled trial is limited due to the necessary large number of patients and long follow-up. Observational studies carry a high risk of bias. The meta-analytic approach may be used if the incidence and mortality of hepatocellular carcinoma can be extracted from trials on variceal bleeding and if the combined sample size and follow up is sufficient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To test the inter-rater reliability of the RoB tool applied to Physical Therapy (PT) trials by comparing ratings from Cochrane review authors with those of blinded external reviewers. METHODS Randomized controlled trials (RCTs) in PT were identified by searching the Cochrane Database of Systematic Reviews for meta-analysis of PT interventions. RoB assessments were conducted independently by 2 reviewers blinded to the RoB ratings reported in the Cochrane reviews. Data on RoB assessments from Cochrane reviews and other characteristics of reviews and trials were extracted. Consensus assessments between the two reviewers were then compared with the RoB ratings from the Cochrane reviews. Agreement between Cochrane and blinded external reviewers was assessed using weighted kappa (κ). RESULTS In total, 109 trials included in 17 Cochrane reviews were assessed. Inter-rater reliability on the overall RoB assessment between Cochrane review authors and blinded external reviewers was poor (κ  =  0.02, 95%CI: -0.06, 0.06]). Inter-rater reliability on individual domains of the RoB tool was poor (median κ  = 0.19), ranging from κ  =  -0.04 ("Other bias") to κ  =  0.62 ("Sequence generation"). There was also no agreement (κ  =  -0.29, 95%CI: -0.81, 0.35]) in the overall RoB assessment at the meta-analysis level. CONCLUSIONS Risk of bias assessments of RCTs using the RoB tool are not consistent across different research groups. Poor agreement was not only demonstrated at the trial level but also at the meta-analysis level. Results have implications for decision making since different recommendations can be reached depending on the group analyzing the evidence. Improved guidelines to consistently apply the RoB tool and revisions to the tool for different health areas are needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Social norms pervade almost every aspect of social interaction. If they are violated, not only legal institutions, but other members of society as well, punish, i.e., inflict costs on the wrongdoer. Sanctioning occurs even when the punishers themselves were not harmed directly and even when it is costly for them. There is evidence for intergroup bias in this third-party punishment: third-parties, who share group membership with victims, punish outgroup perpetrators more harshly than ingroup perpetrators. However, it is unknown whether a discriminatory treatment of outgroup perpetrators (outgroup discrimination) or a preferential treatment of ingroup perpetrators (ingroup favoritism) drives this bias. To answer this question, the punishment of outgroup and ingroup perpetrators must be compared to a baseline, i.e., unaffiliated perpetrators. By applying a costly punishment game, we found stronger punishment of outgroup versus unaffiliated perpetrators and weaker punishment of ingroup versus unaffiliated perpetrators. This demonstrates that both ingroup favoritism and outgroup discrimination drive intergroup bias in third-party punishment of perpetrators that belong to distinct social groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Daily we cope with upcoming potentially disadvantageous events. Therefore, it makes sense to be prepared for the worst case. Such a 'pessimistic' bias is reflected in brain activation during emotion processing. Healthy individuals underwent functional neuroimaging while viewing emotional stimuli that were earlier cued ambiguously or unambiguously concerning their emotional valence. Presentation of ambiguously announced pleasant pictures compared with unambiguously announced pleasant pictures resulted in increased activity in the ventrolateral prefrontal, premotor and temporal cortex, and in the caudate nucleus. This was not the case for the respective negative conditions. This indicates that pleasant stimuli after ambiguous cueing provided 'unexpected' emotional input, resulting in the adaptation of brain activity. It strengthens the hypothesis of a 'pessimistic' bias of brain activation toward ambiguous emotional events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The Cochrane risk of bias (RoB) tool has been widely embraced by the systematic review community, but several studies have reported that its reliability is low. We aim to investigate whether training of raters, including objective and standardized instructions on how to assess risk of bias, can improve the reliability of this tool. We describe the methods that will be used in this investigation and present an intensive standardized training package for risk of bias assessment that could be used by contributors to the Cochrane Collaboration and other reviewers. METHODS/DESIGN This is a pilot study. We will first perform a systematic literature review to identify randomized clinical trials (RCTs) that will be used for risk of bias assessment. Using the identified RCTs, we will then do a randomized experiment, where raters will be allocated to two different training schemes: minimal training and intensive standardized training. We will calculate the chance-corrected weighted Kappa with 95% confidence intervals to quantify within- and between-group Kappa agreement for each of the domains of the risk of bias tool. To calculate between-group Kappa agreement, we will use risk of bias assessments from pairs of raters after resolution of disagreements. Between-group Kappa agreement will quantify the agreement between the risk of bias assessment of raters in the training groups and the risk of bias assessment of experienced raters. To compare agreement of raters under different training conditions, we will calculate differences between Kappa values with 95% confidence intervals. DISCUSSION This study will investigate whether the reliability of the risk of bias tool can be improved by training raters using standardized instructions for risk of bias assessment. One group of inexperienced raters will receive intensive training on risk of bias assessment and the other will receive minimal training. By including a control group with minimal training, we will attempt to mimic what many review authors commonly have to do, that is-conduct risk of bias assessment in RCTs without much formal training or standardized instructions. If our results indicate that an intense standardized training does improve the reliability of the RoB tool, our study is likely to help improve the quality of risk of bias assessments, which is a central component of evidence synthesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A large body of research suggests that when we retrieve visual information from memory, we look back to the location where we encoded these objects. It has been proposed that the oculomotor trace we act out during encoding is stored in long-term memory, along other contents of the episodic representation. If memory recall triggers the eyes to revisit the location where the stimulus was encoded, is there also an effect in the reverse direction? Can eye movements trigger memory recall? In Experiment 1 participants encoded two faces at two different locations on the computer screen. Then, the average face (morph) of these two faces appeared in either of the two encoding locations and participants had to indicate whether it resembles more the first or second face. In Experiment 2 the morph appeared in a new location, but participants had to repeat one of the oculomotor traces that was used during encoding. Participants’ morph perception was influenced both by the location and the eye-movement it was presented with. Our results suggest that eye-movements can bias memory recall, but only in a short-lasting and rather fragile way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the influence of playing a video game on children’s ability to distinguish between fantasy and reality. School-age children played a platform game for 15 min and then performed a fantasy/reality distinction task in which they were to judge whether images (from the platform game and from other games) were fantasy images or reality images. Unlike those in the control group (who played a memory game), the children in the experimental group showed a response bias toward mistakenly classifying reality images from the video game as fantasy images (as determined by means of an analysis based on signal detection theory). We conclude that playing the video game exerted a short-term influence on children’s ability to distinguish between fantasy and reality.