978 resultados para Venous Insufficiency
Resumo:
The microbiological monitoring of the water used for hemodialysis is extremely important, especially because of the debilitated immune system of patients suffering from chronic renal insufficiency. To investigate the occurrence and species diversity of bacteria in waters, water samples were collected monthly from a hemodialysis center in upstate São Paulo and tap water samples at the terminal sites of the distribution system was sampled repeatedly (22 times) at each of five points in the distribution system; a further 36 samples were taken from cannulae in 19 hemodialysis machines that were ready for the next patient, four samples from the reuse system and 13 from the water storage system. To identify bacteria, samples were filtered through 0.22 µm-pore membranes; for mycobacteria, 0.45 µm pores were used. Conventional microbiological and molecular methods were used in the analysis. Bacteria were isolated from the distribution system (128 isolates), kidney machine water (43) and reuse system (3). Among these isolates, 32 were Gram-positive rods, 120 Gram-negative rods, 20 Gram-positive cocci and 11 mycobacteria. We propose the continual monitoring of the water supplies in hemodialysis centers and the adoption of effective prophylactic measures that minimize the exposure of these immunodeficient patients to contaminated sources of water.
Resumo:
Aim. Percutaneous endovascular procedures have become the standard treatment of arteriovenous fistulae and graft stenosis. This study evaluates the immediate results of angiographic procedures performed by nephrologists in patients with dysfunctional arteriovenous fistulae and arteriovenous graft stenosis. Patients and Methods. A retrospective analysis was performed on patients referred to the three Interventional Nephrology units between April and June, 2010. Clinical data were recorded. Results. A total of 113 procedures were performed: 59 in arteriovenous fistulae and 54 in arteriovenous graft stenosis. The main reasons for referral were increased venous pressure (21%), limb oedema (21%) and decreased intra-access flow (20%). Stenoses were detected in 85% of the procedures, mostly in patients with arteriovenous graft stenosis (56%). The main locations of stenosis were the outflow vein (cephalic/basilic) in arteriovenous fistulae (34%) and venous anastomosis in arteriovenous graft stenosis(48%). Angioplasty was performed in 73% of procedures where stenoses were detected. The immediate success rate was 91% for arteriovenous fistulae and 83% for arteriovenous graft stenosis. Partial success was obtained in 11% of angiographies. The complication rate was 7%. Conclusions. Physical examination findings led, in at least half the cases, to angiography referral and enabled the diagnosis and treatment of stenoses. For this reason, we advocate that this tool should be included in any vascular access monitoring programme. Our results support the safety of these procedures performed by nephrologists and their efficacy in the recovery of dysfunctional arteriovenous fistulae and arteriovenous graft stenosis.
Resumo:
A 25-year-old male without prior co-morbidities was admitted to hospital with Fusobacterium necrophorum bacteremia, where he was found to have liver and splenic abscesses. Further evaluation with echocardiography revealed a bicuspid aortic valve with severe insufficiency and a 1.68 x 0.86 cm vegetation. The patient required abscess drainage, intravenous antimicrobial therapy and aortic valve replacement. Complete resolution of the infection was achieved after valve replacement and a prolonged course of intravenous antimicrobial therapy. A brief analysis of the patient's clinical course and review of the literature is presented.
Resumo:
Objectivos: Determinar a possibilidade de avaliação não invasiva da pressão venosa central (PVC) através da análise da veia cava inferior (VCI), obtida por ecocardiografia transtorácica (ETT). Desenho: Estudo prospectivo com 3 anos de duração. Local: Unidade de Cuidados Intensivos Polivalente(UCIP) de 16 camas. Métodos: Estudados doentes admitidos numa UCIP nos quais se avaliou a PVC em simultâneo com exame ETT que, para além da visualização da VCI, consistiu na obtenção da dimensão das cavidades cardíacas e função sistólica do ventrículo esquerdo. Para a correlação foram utilizados testes estatísticos paramétricos e não paramétricos. Resultados: Admitidos 560 doentes com registo simultâneo de PVC e ETT e incluídos 477 doentes em que foi possível visualizar a VCI, com idade média de 62,6 ±17,3 anos, média de internamento de 11,9 ± 18,7 dias, um índice APACHE II médio de 23,9 ± 8,9 e SAPS II médio de 55,7 ± 20,4. Por análise de regressão linear verificou-se uma relação entre a PVC e a dimensão máxima da VCI (p=0,013), o índice da VCI (p=0,001) e a presença de ventilação mecânica (p=0,002). A correlação linear entre a PVC e a dimensão máxima da VCI e respectivo índice foi de 0,34 e 0,44. Por teste de qui-quadrado, verificou-se uma relação estatisticamente significativa entre os seguintes intervalos de valores: índice da VCI <25% e PVC> 13mmHg; índice da VCI entre 26 e 50% e PVC entre 8 e 12mmHg; índice da VCI> 51% e PVC> 7mmHg; dimensão máxima da VCI> 20mmHg e PVC> 13 mmHg; dimensão máxima da VCI> 10mm e PVC> 7mmHg. Nos doentes com dilatação do ventrículo direito (VD) observou-se uma relação mais fraca entre a PVC <7mmHg e a dimensão máxima da VCI <10mm; nos doentes admitidos por exacerbação de doença pulmonar crónica verificou-se uma correlação fraca entre a PVC <7mmHg e o índice da VCI> 50%. A dimensão máxima da VCI, mas não o seu índice, correlacionou-se com a dilatação do VD e AD. Conclusões: A análise da VCI por ETT revelou-se útil na avaliação qualitativa da PVC em doentes admitidos numa UCIP. Em doentes com dilatação do VD e admitidos por exacerbação de doença pulmonar crónica, os métodos avaliados não foram fidedignos para valores baixos de PVC. A dilatação da VCI traduz melhor a cronicidade da doença, enquanto o índice da VCI reflecte melhor o estado de volemia.
Resumo:
Infrapopliteal mycotic aneurysm resulting from endocarditis is rare, with only a few reported cases. We describe the case of a 28-year-old male patient who was suffering with pain and edema in the right leg. The ultrasound revealed an aneurysm of the right tibioperoneal trunk and a deep vein thrombosis (DVT). The patient was admitted and developed acute congestive heart failure, being diagnosed with possible endocarditis. A pseudo-aneurysm was revealed by arteriography. Aggressive antibiotic treatment was initiated, and open surgery confirmed a mycotic pseudo-aneurysm of the tibioperoneal trunk. To our knowledge, this is the 8th case reported of an infected aneurysm in this particular location.
Resumo:
Thrombophilias, whether inherited or acquired, are a topic of increased interest in women’s health. Factors that enhance thrombus formation in the presence of thrombophilia include oral contraception, hormone replacement therapy, pregnancy and the puerperium. The risk of venous thomboembolism with hormonal contraceptive use is greater in women with underlying thrombophilias, and thrombosis usually occurs earlier than in women without defined thrombophilias. The degree of increased risk varies according to the underlying thrombophilic defect, the largest bulk of evidence referring to women with Factor V Leiden or prothrombin gene mutation. However, most instances of thrombosis occur due to a combination of inherited, acquired and environmental factors. Before starting oral contraception it is important to screen patients to identify those at increased risk of thrombosis.
Resumo:
Introduction: The rat is probably the animal species most widely used in experimental studies on nerve repair. The aim of this work was to contribute to a better understanding of the morphology and blood supply of the rat brachial plexus. Material and Methods: Thirty adult rats were studied regarding brachial plexus morphology and blood supply. Intravascular injection and dissection under an operating microscope, as well as light microscopy and scanning electron microscopy techniques were used to define the microanatomy of the rat brachial plexus and its vessels. Results: The rat brachial plexus was slightly different from the human brachial plexus. The arterial and venous supply to the brachial plexus plexus was derived directly or indirectly from neighboring vessels. These vessels formed dense and interconnected plexuses in the epineurium, perineurium, and endoneurium. Several brachial plexus components were accompanied for a relatively long portion of their length by large and constant blood vessels that supplied their epineural plexus, making it possible to raise these nerves as flaps. Discussion: The blood supply to the rat brachial plexus is not very different from that reported in humans, making the rat a useful animal model for the experimental study of peripheral nerve pathophysiology and treatment. Conclusion: Our results support the homology between the rat and the human brachial plexus in terms of morphology and blood supply. This work suggests that several components of the rat brachial plexus can be used as nerve flaps, including predominantly motor, sensory or mixed nerve fibers. This information may facilitate new experimental procedures in this animal model.
Resumo:
The authors present a case of a 27-year-old multiparous woman, with multiple thrombophilia, whose pregnancy was complicated with deep venous thrombosis requiring placement of a vena cava filter. At 15th week of gestation, following an acute deep venous thrombosis of the right inferior limb, anticoagulant therapy with low-molecular-weight heparin (LMWH) was instituted without improvement in her clinical status. Subsequently, at 18 weeks of pregnancy, LMWH was switched to warfarin. At 30th week of gestation, the maintenance of high thrombotic risk was the premise for placement of an inferior vena cava filter for prophylaxis of pulmonary embolism during childbirth and postpartum. There were no complications and a vaginal delivery was accomplished at 37 weeks of gestation. Venal placement of inferior vena cava filters is an attractive option as prophylaxis for pulmonary embolism during pregnancy.
Resumo:
O activador recombinante do plasminogénio tecidular e, de todos os fibrinolíticos, o que tem maior especificidade para a fibrina e semi-vida mais curta; daí a sua grande eficácia na lise dos trombos e a quase inexistência de complicações hemorrágicas. Os autores descrevem o caso de um recém-nascido com trombose extensa da veia cava inferior e veia renal direita em que a terapêutica com activador recombinante do plasminogénio tecidular, levou a uma diminuição progressiva do trombo e repermeabilização completa de ambos os vasos em 12 horas. Nao houve efeitos adversos relevantes.
Resumo:
Aim: The objective was to describe an outbreak of bloodstream infections by Burkholderia cepacia complex (Bcc) in bone marrow transplant and hematology outpatients.Methods: On February 15, 2008 a Bcc outbreak was suspected. 24 cases were identified. Demographic and clinical data were evaluated. Environment and healthcare workers' (HCW) hands were cultured. Species were determined and typed. Reinforcement of hand hygiene, central venous catheter (CVC) care, infusion therapy, and maintenance of laminar flow cabinet were undertaken. 16 different HCWs had cared for the CVCs. Multi-dose heparin and saline were prepared on counter common to both units.Findings: 14 patients had B. multivorans(one patient had also B. cenopacia), six non-multivorans Bcc and one did not belong to Bcc. Clone A B. multivorans occurred in 12 patients (from Hematology); in 10 their CVC had been used on February 11/12. Environmental and HCW cultures were negative. All patients were treated with meropenem, and ceftazidime lock-therapy. Eight patients (30%) were hospitalized. No deaths occurred. After control measures (multidose vial for single patient; CVC lock with ceftazidime; cleaning of laminar flow cabinet; hand hygiene improvement; use of cabinet to store prepared medication), no new cases occurred.Conclusions: This polyclonal outbreak may be explained by a common source containing multiple species of Bcc, maybe the laminar flow cabinet common to both units. There may have been contamination by B. multivorans (clone A) of multi-dose vials.
Resumo:
Objectivo: Avaliar a acuidade da angiografia de subtracção digital (ASD) no diagnóstico morfológico da conexão venosa pulmonar anómala (CVPA) em crianças. Concepção do estudo: Estudo prospectivo de doentes consecutivos entre Janeiro de 1989 e Julho de 1992. Tipo de Atendimento: Serviço de Cardiologia Pediátrica de um Hospital Central. População: Vinte e quatro doentes com CVPA. Métodos: Todos os doentes fizeram avaliação clínica e ecocardiográfica completa (modo M, bidimensional e Doppler) antes da realização do exame hemodinâmico. Em todos os casos se fizeram, de modo sistemático, injecções selectivas de contraste de baixa osmolaridade (0,5-1 ml/kg; dose total <6 mi/kg) no tronco e ramos da artéria pulmonar com registo em angiografia com subtracção digital (ASD). As imagens colhidas foram trabalhadas, selecciona das e armazenadas em video-cassetes e películas fotográficas (câmara multiformato). Resultados: Dezasseis doentes tinham CVPA total (CVPAT): onze à veia cava superior (VCS), dois ao seio coronário e três infradiafragmáticos (dois à veia cava inferior (VCI) e um à veia porta). Oito crianças tinham CVPA parcial (CVPAP): três à VCS, uma à aurícula direita (AD), três à VCI (síndroma da cimitarra) e num caso a CVPA era mista. Em oito doentes (seis com CVPAT e dois com CVPAP), a ASD contribuiu significativamente para o diagnóstico final tendo completado ou corrigido a informação obtida por ecocardiografia. Nos dezoito doentes submetidos a cirurgia cardíaca foi confirmado o diagnóstico obtido por ASD. Conclusões: A ASD é um método muito útil para o diagnóstico anatómico de doentes com CVPA. Na nossa experiência foi particularmente informativa a análise de registos em «video». A ASD está indicada nos casos em que os achados clínicos e ecocardiográficos não sejam típicos.
Resumo:
Acquired factor X deficiency is an extremely rare situation. It has shown to be associated with systemic amyloidosis, respiratory mycoplasma infection, factor X inhibitors, antiphospholipid antibodies, vitamin K defi ciency/liver disease as well as the use of certain medications (meropenem, valproic acid). The pathogenesis and transient nature of this deficit remain poorly understood. The authors describe the case of a teenager hospitalised for extensive burns that developed active bleeding after removal of central venous catheter. He was diagnosed with transient factor X deficiency. Normalisation of coagulation status and factor X levels occurred spontaneously 10 days after the bleeding episode.
Resumo:
Infections by Candida species are a high-impact problem in public health due to their wide incidence in hospitalized patients. The goal of this study was to evaluate frequency, susceptibility to antifungals, and genetic polymorphism of Candida species isolated from clinical specimens of hospitalized patients. The Candida isolates included in this study were obtained from blood cultures, abdominal fluids, and central venous catheters (CVC) of hospitalized patients at the Clinical Hospital of the Federal University of Uberlândia during the period of July 2010 - June 2011. Susceptibility tests were conducted by the broth microdilution method. The RAPD-PCR tests used employed initiator oligonucleotides OPA09, OPB11, and OPE06. Of the 63 Candida isolates, 18 (28.5%) were C. albicans, 20 (31.7%) were C. parapsilosis complex species, 14 (22.2%) C. tropicalis, four (6.4%) C. glabrata, four (6.4%) C. krusei, two (3.3%) C. kefyr, and one (1.6%) C. lusitaniae. In vitro resistance to amphotericin B was observed in 12.7% of isolates. In vitroresistance to azoles was not detected, except for C. krusei. The two primers, OPA09 and OPB11, were able to distinguish different species. Isolates of C. albicans and C. parapsilosis complex species presented six and five clusters, respectively, with the OPA09 marker by RAPD-PCR, showing the genetic variability of the isolates of those species. It was concluded that members of the C. parapsilosis complex were the most frequent species found, and most isolates were susceptible to the antifungals amphotericin B, flucozanole, and itraconazole. High genetic polymorphisms were observed for isolates of C. albicans and C. parapsilosis complex species, mainly with the OPA09 marker.
Resumo:
Os autores descrevem 2 casos de sinus pericranii congénitos associados a anomalias da vertente venosa intracraniana. Revêem a bibliografia existente a propósito desta associação e tecem considerações sobre os eventuais mecanismos etiopatogénicos implicados e as consequências terapêuticas.
Resumo:
Calciphylaxis is a rare and devastating obliterative vasculopathy, leading to ischemia and subcutaneous necrosis. In most cases it affects patients with renal disease and is associated with high morbidity and mortality. We present two case reports followed recently in our department, and a literature review on this topic. Case one refers to an 80 -year -old Caucasian woman with chronic kidney disease stage 5 and primary hyperparathyroidism with secondary brown tumour and calciphylaxis. Case two refers to a 59 -year -old Caucasian woman admitted with severe nephrotic syndrome associated with amyloidosis, that developed a catastrophic picture of calciphylaxis, ending in the patient’s death. There is a critical need to understand the pathogenesis of calciphylaxis. Its comprehension is the only way to improve the survival of these patients, and may help to elucidate the pathophysiology of vascular calcification in general. Educating physicians in the prevention and early detection of calciphylaxis is crucial. Only by increasing the knowledge about risk factors, pathophysiology, response to treatment and outcome, will we be able to improve prophylaxis and therapy of patients with calciphylaxis, decreasing the high mortality of this entity.