889 resultados para Value analysis (Cost control)
Resumo:
Grid operators and electricity retailers in Ireland manage peak demand, power system balancing and grid congestion by offering relevant incentives to consumers to reduce or shift their load. The need for active consumers in the home using smart appliances has never been greater, due to increased variable renewable generation and grid constraints. In this paper an aggregated model of a single compressor fridge-freezer population is developed. A price control strategy is examined to quantify and value demand response savings during a representative winter and summer week for Ireland in 2020. The results show an average reduction in fridge-freezer operating cost of 8.2% during winter and significantly lower during summer in Ireland. A peak reduction of at least 68% of the average winter refrigeration load is achieved consistently during the week analysed using a staggering control mode. An analysis of the current ancillary service payments confirms that these are insufficient to ensure widespread uptake by the small consumer, and new mechanisms need to be developed to make becoming an active consumer attractive. Demand response is proposed as a new ancillary service called ramping capability, as the need for this service will increase with more renewable energy penetration on the power system.
Resumo:
Severe refractory asthma poses a substantial burden in terms of healthcare costs but relatively little is known about the factors which drive these costs. This study uses data from the British Thoracic Society Difficult Asthma Registry (n=596) to estimate direct healthcare treatment costs from an National Health Service perspective and examines factors that explain variations in costs. Annual mean treatment costs among severe refractory asthma patients were £2912 (SD £2212) to £4217 (SD £2449). Significant predictors of costs were FEV1% predicted, location of care, maintenance oral corticosteroid treatment and body mass index. Treating individuals with severe refractory asthma presents a substantial cost to the health service.
Resumo:
High Voltage Direct Current (HVDC) electric power transmission is a promising technology for integrating offshore wind farms and interconnecting power grids in different regions. In order to maintain the DC voltage, droop control has been widely used. Transmission line loss constitutes an import part of the total power loss in a multi-terminal HVDC scheme. In this paper, the relation between droop controller design and transmission loss has been investigated. Different MTDC layout configurations are compared to examine the effect of droop controller design on the transmission loss.
Resumo:
Multiple Table Lookup architectures in Software Defined Networking (SDN) open the door for exciting new network applications. The development of the OpenFlow protocol supported the SDN paradigm. However, the first version of the OpenFlow protocol specified a single table lookup model with the associated constraints in flow entry numbers and search capabilities. With the introduction of multiple table lookup in OpenFlow v1.1, flexible and efficient search to support SDN application innovation became possible. However, implementation of multiple table lookup in hardware to meet high performance requirements is non-trivial. One possible approach involves the use of multi-dimensional lookup algorithms. A high lookup performance can be achieved by using embedded memory for flow entry storage. A detailed study of OpenFlow flow filters for multi-dimensional lookup is presented in this paper. Based on a proposed multiple table lookup architecture, the memory consumption and update performance using parallel single field searches are evaluated. The results demonstrate an efficient multi-table lookup implementation with minimum memory usage.
Resumo:
The need for fast response demand side participation (DSP) has never been greater due to increased wind power penetration. White domestic goods suppliers are currently developing a `smart' chip for a range of domestic appliances (e.g. refrigeration units, tumble dryers and storage heaters) to support the home as a DSP unit in future power systems. This paper presents an aggregated population-based model of a single compressor fridge-freezer. Two scenarios (i.e. energy efficiency class and size) for valley filling and peak shaving are examined to quantify and value DSP savings in 2020. The analysis shows potential peak reductions of 40 MW to 55 MW are achievable in the Single wholesale Electricity Market of Ireland (i.e. the test system), and valley demand increases of up to 30 MW. The study also shows the importance of the control strategy start time and the staggering of the devices to obtain the desired filling or shaving effect.
Resumo:
BACKGROUND: The value of adjuvant radiotherapy in triple negative breast cancer (TNBC) remains unclear. A systematic review and meta-analysis was conducted in TNBC patients to assess survival and recurrence outcomes associated with radiotherapy following either breast conserving therapy (BCT) or post-mastectomy radiotherapy (PMRT). METHODS: Four electronic databases were searched from January 2000 to November 2015 (PubMed, MEDLINE, EMBASE and Web of Science). Studies investigating overall survival and/or recurrence in TNBC patients according to radiotherapy administration were included. A random effects meta-analysis was conducted using mastectomy only patients as the reference. RESULTS: Twelve studies were included. The pooled hazard ratio (HR) for locoregional recurrence comparing BCT and PMRT to mastectomy only was 0.61 (95% confidence interval [CI] 0.41-0.90) and 0.62 (95% CI 0.44-0.86), respectively. Adjuvant radiotherapy was not significantly associated with distant recurrence. The pooled HR for overall survival comparing BCT and PMRT to mastectomy only was 0.57 (95% CI 0.36-0.88) and HR 1.12 (95% CI 0.75, 1.69). Comparing PMRT to mastectomy only, tests for interaction were not significant for stage (p=0.98) or age at diagnosis (p=0.85). However, overall survival was improved in patients with late-stage disease (T3-4, N2-3) pooled HR 0.53 (95% CI 0.32-0.86), and women <40 years, pooled HR 0.30 (95% CI 0.11-0.82). CONCLUSIONS: Adjuvant radiotherapy was associated with a significantly lower risk of locoregional recurrence in TNBC patients, irrespective of the type of surgery. While radiotherapy was not consistently associated with an overall survival gain, benefits may be obtained in women with late-stage disease and younger patients.