992 resultados para Umbilical arteries
Resumo:
Purpose: In primary prevention of cardiovascular disease (CVD), it is accepted that the intensity of risk factor treatment should be guided by the magnitude of absolute risk. Risk factors tools like Framingham risk score (FHS) or noninvasive atherosclerosis imaging tests are available to detect high risk subjects. However, these methods are imperfect and may misclassify a large number of individuals. The purpose of this prospective study was to evaluate whether the prediction of future cardiovascular events (CVE) can be improved when subclinical imaging atherosclerosis (SCATS) is combined with the FRS in asymptomatic subjects. Methods: Overall, 1038 asymptomatic subjects (413 women, 625 men, mean age 49.1±12.8 years) were assessed for their cardiovascular risk using the FRS. B-mode ultrasonography on carotid and femoral arteries was performed by two investigators to detect atherosclerotic plaques (focal thickening of intima-media > 1.2 mm) and to measure carotid intima-media thickness (C-IMT). The severity of SCATS was expressed by an ATS-burden Score (ABS) reflecting the number of the arterial sites with >1 plaques (range 0-4). CVE were defined as fatal or non fatal acute coronary syndrome, stroke, or angioplasty for peripheral artery disease. Results: during a mean follow-up of 4.9±3.1 years, 61 CVE were recorded. Event rates the rate of CVE increased significantly from 2.7% to 39.1% according to the ABS (p<0.001) and from 4% to 24.6% according to the quartiles of C-IMT. Similarly, FRS predicted CVE (p<0.001). When computing the angiographic markers of SCATS in addition of FRS, we observed an improvement of net reclassification rate of 16.6% (p< 0.04) for ABS as compared to 5.5% (p = 0.26) for C-IMT. Conclusion: these results indicate that the detection of subjects requiring more attention to prevent CVE can be significantly improved when using both FRS and SCATS imaging.
Resumo:
PURPOSE: The purposes of this study were to (1) develop a high-resolution 3-T magnetic resonance angiography (MRA) technique with an in-plane resolution approximate to that of multidetector coronary computed tomography (MDCT) and a voxel size of 0.35 × 0.35 × 1.5 mm³ and to (2) investigate the image quality of this technique in healthy participants and preliminarily in patients with known coronary artery disease (CAD). MATERIALS AND METHODS: A 3-T coronary MRA technique optimized for an image acquisition voxel as small as 0.35 × 0.35 × 1.5 mm³ (high-resolution coronary MRA [HRC]) was implemented and the coronary arteries of 22 participants were imaged. These included 11 healthy participants (average age, 28.5 years; 5 men) and 11 participants with CAD (average age, 52.9 years; 5 women) as identified on MDCT. In addition, the 11 healthy participants were imaged using a method with a more common spatial resolution of 0.7 × 1 × 3 mm³ (regular-resolution coronary MRA [RRC]). Qualitative and quantitative comparisons were made between the 2 MRA techniques. RESULTS: Normal vessels and CAD lesions were successfully depicted at 350 × 350 μm² in-plane resolution with adequate signal-to-noise ratio (SNR) and contrast-to-noise ratio. The CAD findings were consistent among MDCT and HRC. The HRC showed a 47% improvement in sharpness despite a reduction in SNR (by 72%) and in contrast-to-noise ratio (by 86%) compared with the regular-resolution coronary MRA. CONCLUSION: This study, as a first step toward substantial improvement in the resolution of coronary MRA, demonstrates the feasibility of obtaining at 3 T a spatial resolution that approximates that of MDCT. The acquisition in-plane pixel dimensions are as small as 350 × 350 μm² with a 1.5-mm slice thickness. Although SNR is lower, the images have improved sharpness, resulting in image quality that allows qualitative identification of disease sites on MRA consistent with MDCT.
Resumo:
Adenosine triphosphate (ATP) is now established as a principle vaso-active mediator in the vasculature. Its actions on arteries are complex, and are mediated by the P2X and P2Y receptor families. It is generally accepted that ATP induces a bi-phasic response in arteries, inducing contraction via the P2X and P2Y receptors on the smooth muscle cells, and vasodilation via the actions of P2Y receptors located on the endothelium. However, a number of recent studies have placed P2X1 receptors on the endothelium of some arteries. The use of a specific P2X1 receptor ligand, a, b methylene ATP has demonstrated that P2X1 receptors also have a bi-functional role. The actions of ATP on P2X1 receptors is therefore dependant on its location, inducing contraction when located on the smooth muscle cells, and dilation when expressed on the endothelium, comparable to that of P2Y receptors.
Resumo:
BACKGROUND AND PURPOSE: A new clinical construct termed embolic stroke of undetermined source (ESUS) was recently introduced, but no such population has been described yet. Our aim is to provide a detailed descriptive analysis of an ESUS population derived from a large prospective ischemic stroke registry using the proposed diagnostic criteria. METHODS: The criteria proposed by the Cryptogenic Stroke/ESUS International Working Group were applied to the Athens Stroke Registry to identify all ESUS patients. ESUS was defined as a radiologically confirmed nonlacunar brain infarct in the absence of (a) extracranial or intracranial atherosclerosis causing ≥50% luminal stenosis in arteries supplying the ischemic area, (b) major-risk cardioembolic source, and (c) any other specific cause of stroke. RESULTS: Among 2735 patients admitted between 1992 and 2011, 275 (10.0%) were classified as ESUS. In the majority of ESUS (74.2%), symptoms were maximal at onset. ESUS were of moderate severity (median National Institute Health Stroke Scale score, 5). The most prevalent risk factor was arterial hypertension (64.7%), and 50.9% of patients were dyslipidemic. Among potential causes of the ESUS, covert atrial fibrillation (AF) was the most prevalent: in 30 (10.9%) patients, AF was diagnosed during hospitalization for stroke recurrence, whereas in 50 (18.2%) patients AF was detected after repeated ECG monitoring during follow-up. Also, covert AF was strongly suggested in 38 patients (13.8%) but never recorded. CONCLUSIONS: About 10% of patients with first-ever ischemic stroke met criteria for ESUS; covert paroxysmal AF seems to be a frequent cause of ESUS.
Resumo:
Purpose of reviewAtherosclerotic renal artery stenosis (ARAS) usually occurs in patients at high risk of vascular disease, and is associated with increased mortality. The primary goals of ARAS treatment include the control of blood pressure (BP), the improved renal function, and the benefit on cardiovascular events. Although medical therapy remains the standard approach to the management of ARAS, percutaneous transluminal renal angioplasty (PTRA) revascularization can be a therapeutic option under certain conditions.Recent findingsRecent evidence confirms that ARAS increases cardiovascular risk, independent of BP and renal function. This suggests that revascularization might potentially improve overall prognosis, but no data are available currently. In cases of significant ARAS, the accepted indications for PTRA are uncontrollable hypertension, gradual or acute renal function decline with the use of agents blocking the renin-angiotensin-aldosterone system, and recurrent flash pulmonary edema. The key point of treatment success remains in all cases a careful patient selection.SummaryAlthough the atherosclerotic lesions of the renal arteries tend to progress over time, the anatomical lesion progression is not always associated with changes in BP. Furthermore, a poor correlation was noted between the degree of anatomic stenosis and glomerular filtration rate. The high cardiovascular risk warrants aggressive pharmacological treatment to prevent progression of the generalized vascular disorder. Ongoing trials will show whether PTRA revascularization has added, long-term effects on BP, renal function, and cardiovascular prognosis. With or without PTRA revascularization, medical therapy using antihypertensive agents, statins, and aspirin is necessary in almost all cases.
Resumo:
Introduction: Coronary magnetic resonance angiography (MRA) is a medical imaging technique that involves collecting data from consecutive heartbeats, always at the same time in the cardiac cycle, in order to minimize heart motion artifacts. This technique relies on the assumption that coronary arteries always follow the same trajectory from heartbeat to heartbeat. Until now, choosing the acquisition window in the cardiac cycle was based exclusively on the position of minimal coronary motion. The goal of this study was to test the hypothesis that there are time intervals during the cardiac cycle when coronary beat-to-beat repositioning is optimal. The repositioning uncertainty values in these time intervals were then compared with the intervals of low coronary motion in order to propose an optimal acquisition window for coronary MRA. Methods: Cine breath-hold x-ray angiograms with synchronous ECG were collected from 11 patients who underwent elective routine diagnostic coronarography. Twenty-three bifurcations of the left coronary artery were selected as markers to evaluate repositioning uncertainty and velocity during cardiac cycle. Each bifurcation was tracked by two observers, with the help of a user-assisted algorithm implemented in Matlab (The Mathworks, Natick, MA, USA) that compared the trajectories of the markers coming from consecutive heartbeats and computed the coronary repositioning uncertainty with steps of 50ms until 650ms after the R-wave. Repositioning uncertainty was defined as the diameter of the smallest circle encompassing the points to be compared at the same time after the R-wave. Student's t-tests with a false discovery rate (FDR, q=0.1) correction for multiple comparison were applied to see whether coronary repositioning and velocity vary statistically during cardiac cycle. Bland-Altman plots and linear regression were used to assess intra- and inter-observer agreement. Results: The analysis of left coronary artery beat-to-beat repositioning uncertainty shows a tendency to have better repositioning in mid systole (less than 0.84±0.58mm) and mid diastole (less than 0.89±0.6mm) than in the rest of the cardiac cycle (highest value at 50ms=1.35±0.64mm). According to Student's t-tests with FDR correction for multiple comparison (q=0.1), two intervals, in mid systole (150-200ms) and mid diastole (550-600ms), provide statistically better repositioning in comparison with the early systole and the early diastole. Coronary velocity analysis reveals that left coronary artery moves more slowly in end systole (14.35±11.35mm/s at 225ms) and mid diastole (11.78±11.62mm/s at 625ms) than in the rest of the cardiac cycle (highest value at 25ms: 55.96±22.34mm/s). This was confirmed by Student's t-tests with FDR correction for multiple comparison (q=0.1, FDR-corrected p-value=0.054): coronary velocity values at 225, 575 and 625ms are not much different between them but they are statistically inferior to all others. Bland-Altman plots and linear regression show that intra-observer agreement (y=0.97x+0.02 with R²=0.93 at 150ms) is better than inter-observer (y=0.8x+0.11 with R²=0.67 at 150ms). Discussion: The present study has demonstrated that there are two time intervals in the cardiac cycle, one in mid systole and one in mid diastole, where left coronary artery repositioning uncertainty reaches points of local minima. It has also been calculated that the velocity is the lowest in end systole and mid diastole. Since systole is less influenced by heart rate variability than diastole, it was finally proposed to test an acquisition window between 150 and 200ms after the R-wave.
Resumo:
The molecular mechanisms underlying lymphocyte extravasation remain poorly characterized. We have recently identified junctional adhesion molecule-2 (JAM-2), and have shown that antibodies to JAM-2 stain high endothelial venules (HEVs) within lymph nodes and Peyer patches of adult mice. Here we show that mouse lymphocytes migrate in greater numbers across monolayers of endothelioma cells transfected with JAM-2. The significance of these findings to an understanding of both normal and pathologic lymphocyte extravasation prompted us to clone the human homologue of JAM-2. We herein demonstrate that an anti-JAM-2 antibody, or a soluble JAM-2 molecule, blocks the transmigration of primary human peripheral blood leukocytes across human umbilical vein endothelial cells expressing endogenous JAM-2. Furthermore, we show that JAM-2 is expressed on HEVs in human tonsil and on a subset of human leukocytes, suggesting that JAM-2 plays a central role in the regulation of transendothelial migration.
Resumo:
Pulse wave velocity (PWV) is a surrogate of arterial stiffness and represents a non-invasive marker of cardiovascular risk. The non-invasive measurement of PWV requires tracking the arrival time of pressure pulses recorded in vivo, commonly referred to as pulse arrival time (PAT). In the state of the art, PAT is estimated by identifying a characteristic point of the pressure pulse waveform. This paper demonstrates that for ambulatory scenarios, where signal-to-noise ratios are below 10 dB, the performance in terms of repeatability of PAT measurements through characteristic points identification degrades drastically. Hence, we introduce a novel family of PAT estimators based on the parametric modeling of the anacrotic phase of a pressure pulse. In particular, we propose a parametric PAT estimator (TANH) that depicts high correlation with the Complior(R) characteristic point D1 (CC = 0.99), increases noise robustness and reduces by a five-fold factor the number of heartbeats required to obtain reliable PAT measurements.
Resumo:
Angiotensin II (Ang II) is one of the most potent vasoconstrictors. We document here the innervation of rat and human mesenteric resistance arteries (MRA) by angiotensinergic neurons of the rat and human sympathetic coeliac ganglia. Angiotensinogen (Ang-N)-mRNA and angiotensin converting enzyme-mRNA but no renin-mRNA were detected by using quantitative real time polymerase chain reaction in total RNA extracts of rat coeliac ganglia. In the same extracts, cathepsin D-mRNA was detected: This protease also cleaves Ang I from Ang-N and could therefore account for the generation of neuronal Ang peptides in the absence of renin. In situ hybridization confirmed the presence of Ang-N-mRNA in the cytoplasm of rat coeliac ganglia. By using solid-phase extraction, high performance liquid chromatography and subsequent radioimmunoassay, Ang II and its metabolites were detected in rat and also in human coeliac ganglia. Immunoreactivity for Ang II was demonstrated in rat and human coeliac ganglia neurons and their projections innervating MRA. In addition, segmental angiotensinergic innervation of MRA was also observed. By means of confocal laser scanning microscopy we were able to demonstrate the presence of angiotensinergic synapses en passant along side of vascular smooth muscle cells. Our findings could indicate that Ang II is synthesized inside the neurons of sympathetic coeliac ganglia and may act as an endogenous neurotransmitter locally in MRA.
Resumo:
En los transplantes de progenitores hematopoyéticos, la sangre de cordón umbilical es una fuente establecida de células madre hematopoyéticas que presenta como mayor ventaja una menor incidencia de enfermedades de injerto contra el huésped. Sin embargo, el bajo número de células madre obtenidas de una sola unidad limita su utilización a un número reducido de pacientes. Las células madre hematopoyéticas se definen por su capacidad de automantenimiento y reconstitución de todo el sistema hematopoyético de un huésped trasplantado. En ratón, la combinación de los marcadores de superficie Lin- LSK junto con los marcadores de la familia SLAM, ha permitido establecer una jerarquía en las poblaciones de células madre y progenitores hematopoyéticos. Sin embargo, la población de células madre hematopoyéticas humanas CD34+CD38- es heterogénea y las subpoblaciones de progenitores y células madre no están bien establecidas. Uno de los objetivos de este trabajo es determinar si los marcadores de la familia SLAM podrían redefinir la población de células madre hematopoyéticas humanas CD34+CD38- de forma similar a lo sucedido en ratón. En este trabajo se describe una nueva población de progenitores hematopoyéticos en sangre de cordón umbilical caracterizada por el fenotipo CD34+CD38-CD150+CD135-. Lon ensayos realizados tanto in vitro como in vivo han demostrado que esta población esta formada por células con capacidad de autorrenovación, de diferenciación a todos los linajes hematopoyéticos, y de reconstitución a corto y largo plazo de un modelo murino inmunodeficiente irradiado. Por otro lado, con la finalidad de obtener un número suficiente de progenitores hematopoyéticos para ser trasplantados, se han estudiado diferentes sistemas de expansión in vitro. Se ha observado que el ácido valproico (un inhibidor de las histona deacetilasas) y la activación de la vía de Notch, promueven el mantenimiento y expansión de los progenitores hematopoyéticos reduciendo los procesos de diferenciación.
Resumo:
Background: Visceral artery aneurysms (VAA), although uncommon, are increasingly being detected. We describe a case of spontaneous retroperitoneal hemorrhage from a ruptured IMA aneurysm associated with stenosis of the superior mesenteric artery (SMA) and celiac trunk, successfully treated with surgery. Methods: A 65-year-old man presented with abdominal pain and hypovolemic shock. Abdominal CT scan showed an aneurysm of the inferior mesenteric artery with retroperitoneal hematoma. In addition, an obstructive disease of the superior mesenteric artery and celiac axis was observed. Results: Upon emergency laparotomy a ruptured inferior mesenteric artery aneurysm was detected. The aneurysm was excised and the artery reconstructed by end-to-end anastomosis. Conclusions This report discusses the etiology, presentation, diagnosis and case management of inferior mesenteric artery aneurysms
Resumo:
Skin, arteries and nerves of the upper extremities can be affected by vibration exposure. Recent advances in skin and vascular biology as well as new investigative methods, have shown that neurovascular symptoms may be due to different vascular and neurological disorders which should be differentiated if proper management is to be evaluated. Three types of vascular disorder can be observed in the vibration white finger: digital organic microangiopathy, a digital vasospastic phenomenon and arterial thrombosis in the upper extremities. An imbalance between endothelin-1 and calcitonin-gene-related peptide is probably responsible for the vasospastic phenomenon. Moreover, paresthesiae can be due to either a diffuse vibration neuropathy or a carpal tunnel syndrome. A precise diagnosis is then necessary to adapt the treatment to individual cases. A classification describing the type and severity of the vascular lesions is presented. Asymptomatic lesions are included for adequate epidemiological studies and risk assessment of vibrating tools. Monitoring of vibration exposed workers should include not only a questionnaire about symptoms, but also a clinical evaluation including diagnostic tests for the screening of early asymptomatic neurovascular injuries.
Resumo:
Introduction: Residual pulmonary artery (PA) anomalies are a major concern after surgery for cono-truncal malformations. This study sought to assess residual PA anomalies using MRI/MRA. Methods: 43 MRI/MRA studies were performed in 37 patients after corrective surgery for cono-truncal malformations. MRI/MRA studies comprised spin-echo, cine, velocity-encoded and 3D Gadolinium-enhanced MRA sequences. Residual PA anomalies were searched in ail patients; angiographie data were available in 13 patients and a comparison with MRI/MRA was made. Results: 32/37 patients had postoperative anomalies of the pulmonary arterial tree. Left pulmonary artery stenosis was the most common finding (14/32), followed by stenosis at multiple sites (11/32). Isolated right pulmonary artery stenosis was rare (2/32). The median time interval between MRI/MRA and angiography in the 13 patients undergoing both types of studies was 54 days. The findings between the two examinations were identical regarding stenoses and collateral vessels. In 4 patients, the MRI/MRA study allowed to plan interventional catheterization with balloon dilatation and/or stenting of the obstructed arteries or co il-occlusion of systemic collaterals. Eleven patients had additional surgery based on MRI/MRA findings. Conclusions: Post-operative anomalies of the PA in cono-truncal malformations can reliably be detected with MRI/MRA. This technique allows planning of the intervention al or surgical procedure to correct the residual anomalies and may th us replace or precede catheterization during the follow-up of surgically corrected cono-truncal malformations.
Resumo:
Publicado en la página web de la Consejería de Salud y Bienestar Social: www.juntadeandalucia.es/salud (Consejería de Salud y Bienestar Social/ Profesionales / Nuestro Compromiso por la Calidad / Procesos Asistenciales Integrados
Resumo:
PURPOSE: To assess the diagnostic performance of respiratory self-navigation for whole-heart coronary magnetic resonance (MR) angiography in a patient cohort referred for diagnostic cardiac MR imaging. MATERIALS AND METHODS: Written informed consent was obtained from all participants for this institutional review board-approved study. Self-navigated coronary MR angiography was performed after administration of a contrast agent in 78 patients (mean age, 48.5 years ± 20.7 [standard deviation]; 53 male patients) referred for cardiac MR imaging because of coronary artery disease (n = 40), cardiomyopathy (n = 14), congenital anomaly (n = 17), or "other" (n = 7). Examination duration was recorded, and the image quality for each coronary segment was assessed with consensus reading. Vessel sharpness, length, and diameter were measured. Quantitative values in proximal, middle, and distal segments were compared by using analysis of variance and t tests. A double-blinded comparison with the results of x-ray angiography was performed when such results were available. RESULTS: When patients with different indications for cardiac MR imaging were examined with self-navigated postcontrast coronary MR angiography, whole-heart data sets with 1.15-mm isotropic spatial resolution were acquired in an average of 7.38 minutes ± 1.85. The main and proximal coronary segments could be visualized in 92.3% of cases, while the middle and distal segments could be visualized in 84.0% and 55.8% of cases, respectively. Subjective scores and vessel sharpness were significantly higher in the proximal segments than in the middle and distal segments (P < .05). Anomalies of the coronary arteries could be confirmed or excluded in all cases. Per-vessel sensitivity and specificity for stenosis detection were 64.7% and 85.0%, respectively, in the 31 patients for whom reference standard x-ray coronary angiography results were available. CONCLUSION: The self-navigated coronary MR angiography sequence shows promise for coronary imaging. However, technical improvements are needed to improve image quality, especially in the more distal coronary segments.