939 resultados para Triton X-100
Resumo:
It is often postulated that an increased hip to shoulder differential angle (`X-Factor') during the early downswing better utilises the stretch-shorten cycle and improves golf performance. The current study aims to examine the potential relationship between the X-Factor and performance during the tee-shot. Seven golfers with handicaps between 0 and 10 strokes comprised the low-handicap group, whilst the high-handicap group consisted of eight golfers with handicaps between 11 and 20 strokes. The golfers performed 20 drives and three-dimensional kinematic data were used to quantify hip and shoulder rotation and the subsequent X-Factor. Compared with the low-handicap group, the high-handicap golfers tended to demonstrate greater hip rotation at the top of the backswing and recorded reduced maximum X-Factor values. The inconsistencies evident in the literature may suggest that a universal method of measuring rotational angles during the golf swing would be beneficial for future studies, particularly when considering potential injury.
Resumo:
Computer tomography has been used to image and reconstruct in 3-D an Egyptian mummy from the collection of the British Museum. This study of Tjentmutengebtiu, a priestess from the 22nd dynasty (945-715 BC) revealed invaluable information of a scientific, Egyptological and palaeopathological nature without mutilation and destruction of the painted cartonnage case or linen wrappings. Precise details on the removal of the brain through the nasal cavity and the viscera from the abdominal cavity were obtained. The nature and composition of the false eyes were investigated. The detailed analysis of the teeth provided a much closer approximation of age at death. The identification of materials used for the various amulets including that of the figures placed in the viscera was graphically demonstrated using this technique.
Resumo:
X-ray computed tomography (CT) is a medical imaging technique that produces images of trans-axial planes through the human body. When compared with a conventional radiograph, which is an image of many planes superimposed on each other, a CT image exhibits significantly improved contrast although this is at the expense of reduced spatial resolution.----- A CT image is reconstructed mathematically from a large number of one dimensional projections of the chosen plane. These projections are acquired electronically using a linear array of solid-state detectors and an x ray source that rotates around the patient.----- X-ray computed tomography is used routinely in radiological examinations. It has also be found to be useful in special applications such as radiotherapy treatment planning and three-dimensional imaging for surgical planning.
Resumo:
Two different methods to measure binocular longitudinal corneal apex movements were synchronously applied. High-speed videokeratoscopy at a sampling frequency of 15 Hz and a customdesigned ultrasound distance sensor at 100 Hz were used for the left and the right eye, respectively. Four healthy subjects participated in the study. Simultaneously, cardiac electric cycle (ECG) was registered for each subject at 100 Hz. Each measurement took 20 s. Subjects were asked to suppress blinking during the measurements. A rigid headrest and a bite-bar were used to minimize undesirable head movements. Time, frequency and time-frequency representations of the acquired signals were obtained to establish their temporal and spectral contents. Coherence analysis was used to estimate the correlation between the measured signals. The results showed close correlation between both corneal apex movements and the cardiopulmonary system. Unraveling these relationships could lead to better understanding of interactions between ocular biomechanics and vision. The advantages and disadvantages of the two methods in the context of measuring longitudinal movements of the corneal apex are outlined.
Resumo:
Many high-rise office buildings have been built in Surabaya. The investors have provided complimentary facilities to satisfy their tenants. However, not all given facilities has satisfied the tenants. The purpose of this study is to find out the level of tenant satisfaction in office “X” to the existing facilities and to suggest additional required facilities. Although office “X” is offered the highest rental rate and has known as a prestigious place in Surabaya, only location and public transport have satisfied the Indonesian tenants. Meanwhile, the multi National companies have not satisfied for any existing facilities. Additional ATM facilities and presentable cafeteria, improvement of service and the security system are required by tenants.
Resumo:
The aggregate structure which occurs in aqueous smectitic suspensions is responsible for poor water clarification, difficulties in sludge dewatering and the unusual rheological behaviour of smectite rich soils. These macroscopic properties are dictated by the 3-D structural arrangement of smectite finest fraction within flocculated aggregates. Here, we report results from a relatively new technique, Transmission X-ray Microscopy (TXM), which makes it possible to investigate the internal structure and 3-D tomographic reconstruction of the smectite clay aggregates modified by Al13 keggin macro-molecule [Al13(O)4(OH)24(H2O)12 ]7+. Three different treatment methods were shown resulted in three different micro-structural environments of the resulting flocculation.
Resumo:
This article describes a project to unwrap an ancient Egyptian mummy using X-ray computed tomography (CT). About 600 X-ray CT images were obtained through the mummified body of a female named Tjetmutjengebtiu (or Jeni for short), who was a singer in the great temple of Karnak in Egypt during the 22nd dynasty (c. 945-715 BC). The X-ray CT images reveal details of the remains of body organs, wrappings and jewellery. 3D reconstructions of Jeni’s teeth suggest that she was probably only around 20 years old when she died, although the cause of death cannot be ascertained from the CT scans. The CT images were used to build a 3D model of Jeni’s head which enabled an artist to paint a picture of what Jeni may have looked like during life. A PowerPoint presentation and movie clips are provided as supplementary material that may be useful for teaching.
Resumo:
The thermal analysis of euchroite shows two mass loss steps in the temperature range 100 to 105°C and 185 to 205°C. These mass loss steps are attributed to dehydration and dehydroxylation of the mineral. Hot stage Raman spectroscopy (HSRS) has been used to study the thermal stability of the mineral euchroite, a mineral involved in a complex set of equilibria between the copper hydroxy arsenates: euchroite Cu2(AsO4)(OH).3H2O → olivenite Cu2(AsO4)(OH) → strashimirite Cu8(AsO4)4(OH)4.5H2O → arhbarite Cu2Mg(AsO4)(OH)3. Hot stage Raman spectroscopy inolves the collection of Raman spectra as a function of the temperature. HSRS shows that the mineral euchroite decomposes between 125 and 175 °C with the loss of water. At 125 °C, Raman bands are observed at 858 cm-1 assigned to the ν1 AsO43- symmetric stretching vibration and 801, 822 and 871 cm-1 assigned to the ν3 AsO43- (A1) antisymmetric stretching vibration. A distinct band shift is observed upon heating to 275 °C. At 275 °C the four Raman bands are resolved at 762, 810, 837 and 862 cm-1. Further heating results in the diminution of the intensity in the Raman spectra and this is attributed to sublimation of the arsenate mineral. Hot stage Raman spectroscopy is most useful technique for studying the thermal stability of minerals especially when only very small amounts of mineral are available.
Resumo:
The transition of cubic indium hydroxide to cubic indium oxide has been studied by thermogravimetric analysis complimented with hot stage Raman spectroscopy. Thermal analysis shows the transition of In(OH)3 to In2O3 occurs at 219°C. The structure and morphology of In(OH)3 synthesised using a soft chemical route at low temperatures was confirmed by X-ray diffraction and scanning electron microscopy. A topotactical relationship exists between the micro/nano-cubes of In(OH)3 and In2O3. The Raman spectrum of In(OH)3 is characterised by an intense sharp band at 309 cm-1 attributed to ν1 In-O symmetric stretching mode, bands at 1137 and 1155 cm-1 attributed to In-OH δ deformation modes, bands at 3083, 3215, 3123 and 3262 cm-1 assigned to the OH stretching vibrations. Upon thermal treatment of In(OH)3 new Raman bands are observed at 125, 295, 488 and 615 cm-1 attributed to In2O3. Changes in the structure of In(OH)3 with thermal treatment is readily followed by hot stage Raman spectroscopy.
Resumo:
Bayer hydrotalcites prepared using the seawater neutralisation (SWN) process of Bayer liquors are characterised using X-ray diffraction and thermal analysis techniques. The Bayer hydrotalcites are synthesised at four different temperatures (0, 25, 55, 75 °C) to determine the effect on the thermal stability of the hydrotalcite structure, and to identify other precipitates that form at these temperatures. The interlayer distance increased with increasing synthesis temperature, up to 55 °C, and then decreased by 0.14 Å for Bayer hydrotalcites prepared at 75 °C. The three mineralogical phases identified in this investigation are; 1) Bayer hydrotalcite, 2), calcium carbonate species, and 3) hydromagnesite. The DTG curve can be separated into four decomposition steps; 1) the removal of adsorbed water and free interlayer water in hydrotalcite (30 – 230 °C), 2) the dehydroxylation of hydrotalcite and the decarbonation of hydrotalcite (250 – 400 °C), 3) the decarbonation of hydromagnesite (400 – 550 °C), and 4) the decarbonation of aragonite (550 – 650 °C).
Thermal analysis of synthetic reevesite and cobalt substituted reevesite (Ni,Co)6Fe2(OH)16(CO3)•4H2O
Resumo:
The mineral reevesite and the cobalt substituted reevesite have been synthesised. The d(003) spacings of the minerals ranged from 7.54 to 7.95 Å. The maximum d(003) value occurred at around Ni:Co 0.4:0.6. This maximum in interlayer distance is proposed to be due to a greater number of carbonate anions and water molecules intercalated into the structure. The stability of the reevesite and cobalt doped reevesite was determined by thermogravimetric analysis. The maximum temperature of the reevesite occurs for the unsubstituted reevesite and is around 220°C. The effect of cobalt substitution results in a decrease in thermal stability of the reevesites. Four thermal decomposition steps are observed and are attributed to dehydration, dehydroxylation and decarbonation, decomposition of the formed carbonate and oxygen loss at ~807 °C. A mechanism for the thermal decomposition of the reevesite and the cobalt substituted reevesite is proposed.
Resumo:
The relationship between deformity correction and self-reported patient satisfaction after thoracoscopic anterior scoliosis surgery is unknown. Scoliosis Research Society questionnaire scores, radiographic outcomes, and rib hump correction were prospectively assessed for a group of 100 patients pre-operatively and at two years after surgery. Patients with lower post-op major Cobb angles report significantly higher SRS scores than patients with higher post-op Cobb angles.
Resumo:
Fracture behavior of Cu-Ni laminate composites has been investigated by tensile testing. It was found that as the individual layer thickness decreases from 100 to 20nm, the resultant fracture angle of the Cu-Ni laminate changes from 72 degrees to 50 degrees. Cross-sectional observations reveal that the fracture of the Ni layers transforms from opening to shear mode as the layer thickness decreases while that of the Cu layers keeps shear mode. Competition mechanisms were proposed to understand the variation in fracture mode of the metallic laminate composites associated with length scale.