958 resultados para Time measurements


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A non-hierarchical K-means algorithm is used to cluster 47 years (1960–2006) of 10-day HYSPLIT backward trajectories to the Pico Mountain (PM) observatory on a seasonal basis. The resulting cluster centers identify the major transport pathways and collectively comprise a long-term climatology of transport to the observatory. The transport climatology improves our ability to interpret the observations made there and our understanding of pollution source regions to the station and the central North Atlantic region. I determine which pathways dominate transport to the observatory and examine the impacts of these transport patterns on the O3, NOy, NOx, and CO measurements made there during 2001–2006. Transport from the U.S., Canada, and the Atlantic most frequently reaches the station, but Europe, east Africa, and the Pacific can also contribute significantly depending on the season. Transport from Canada was correlated with the North Atlantic Oscillation (NAO) in spring and winter, and transport from the Pacific was uncorrelated with the NAO. The highest CO and O3 are observed during spring. Summer is also characterized by high CO and O3 and the highest NOy and NOx of any season. Previous studies at the station attributed the summer time high CO and O3 to transport of boreal wildfire emissions (for 2002–2004), and boreal fires continued to affect the station during 2005 and 2006. The particle dispersion model FLEXPART was used to calculate anthropogenic and biomass-burning CO tracer values at the station in an attempt to identify the regions responsible for the high CO and O3 observations during spring and biomass-burning impacts in summer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Spacecraft formation flying navigation continues to receive a great deal of interest. The research presented in this dissertation focuses on developing methods for estimating spacecraft absolute and relative positions, assuming measurements of only relative positions using wireless sensors. The implementation of the extended Kalman filter to the spacecraft formation navigation problem results in high estimation errors and instabilities in state estimation at times. This is due tp the high nonlinearities in the system dynamic model. Several approaches are attempted in this dissertation aiming at increasing the estimation stability and improving the estimation accuracy. A differential geometric filter is implemented for spacecraft positions estimation. The differential geometric filter avoids the linearization step (which is always carried out in the extended Kalman filter) through a mathematical transformation that converts the nonlinear system into a linear system. A linear estimator is designed in the linear domain, and then transformed back to the physical domain. This approach demonstrated better estimation stability for spacecraft formation positions estimation, as detailed in this dissertation. The constrained Kalman filter is also implemented for spacecraft formation flying absolute positions estimation. The orbital motion of a spacecraft is characterized by two range extrema (perigee and apogee). At the extremum, the rate of change of a spacecraft’s range vanishes. This motion constraint can be used to improve the position estimation accuracy. The application of the constrained Kalman filter at only two points in the orbit causes filter instability. Two variables are introduced into the constrained Kalman filter to maintain the stability and improve the estimation accuracy. An extended Kalman filter is implemented as a benchmark for comparison with the constrained Kalman filter. Simulation results show that the constrained Kalman filter provides better estimation accuracy as compared with the extended Kalman filter. A Weighted Measurement Fusion Kalman Filter (WMFKF) is proposed in this dissertation. In wireless localizing sensors, a measurement error is proportional to the distance of the signal travels and sensor noise. In this proposed Weighted Measurement Fusion Kalman Filter, the signal traveling time delay is not modeled; however, each measurement is weighted based on the measured signal travel distance. The obtained estimation performance is compared to the standard Kalman filter in two scenarios. The first scenario assumes using a wireless local positioning system in a GPS denied environment. The second scenario assumes the availability of both the wireless local positioning system and GPS measurements. The simulation results show that the WMFKF has similar accuracy performance as the standard Kalman Filter (KF) in the GPS denied environment. However, the WMFKF maintains the position estimation error within its expected error boundary when the WLPS detection range limit is above 30km. In addition, the WMFKF has a better accuracy and stability performance when GPS is available. Also, the computational cost analysis shows that the WMFKF has less computational cost than the standard KF, and the WMFKF has higher ellipsoid error probable percentage than the standard Measurement Fusion method. A method to determine the relative attitudes between three spacecraft is developed. The method requires four direction measurements between the three spacecraft. The simulation results and covariance analysis show that the method’s error falls within a three sigma boundary without exhibiting any singularity issues. A study of the accuracy of the proposed method with respect to the shape of the spacecraft formation is also presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nearly 22 million Americans operate as shift workers, and shift work has been linked to the development of cardiovascular disease (CVD). This study is aimed at identifying pivotal risk factors of CVD by assessing 24 hour ambulatory blood pressure, state anxiety levels and sleep patterns in 12 hour fixed shift workers. We hypothesized that night shift work would negatively affect blood pressure regulation, anxiety levels and sleep patterns. A total of 28 subjects (ages 22-60) were divided into two groups: 12 hour fixed night shift workers (n=15) and 12 hour fixed day shift workers (n=13). 24 hour ambulatory blood pressure measurements (Space Labs 90207) were taken twice: once during a regular work day and once on a non-work day. State anxiety levels were assessed on both test days using the Speilberger’s State Trait Anxiety Inventory. Total sleep time (TST) was determined using self recorded sleep diary. Night shift workers demonstrated increases in 24 hour systolic (122 ± 2 to 126 ± 2 mmHg, P=0.012); diastolic (75 ± 1 to 79 ± 2 mmHg, P=0.001); and mean arterial pressures (90 ± 2 to 94 ± 2mmHg, P<0.001) during work days compared to off days. In contrast, 24 hour blood pressures were similar during work and off days in day shift workers. Night shift workers reported less TST on work days versus off days (345 ± 16 vs. 552 ± 30 min; P<0.001), whereas day shift workers reported similar TST during work and off days (475 ± 16 minutes to 437 ± 20 minutes; P=0.231). State anxiety scores did not differ between the groups or testing days (time*group interaction P=0.248), suggesting increased 24 hour blood pressure during night shift work is related to decreased TST, not short term anxiety. Our findings suggest that fixed night shift work causes disruption of the normal sleep-wake cycle negatively affecting acute blood pressure regulation, which may increase the long-term risk for CVD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The exsolution of volatiles from magma maintains an important control on volcanic eruption styles. The nucleation, growth, and connectivity of bubbles during magma ascent provide the driving force behind eruptions, and the rate, volume, and ease of gas exsolution can affect eruptive activity. Volcanic plumes are the observable consequence of this magmatic degassing, and remote sensing techniques allow us to quantify changes in gas exsolution. However, until recently the methods used to measure volcanic plumes did not have the capability of detecting rapid changes in degassing on the scale of standard geophysical observations. The advent of the UV camera now makes high sample rate gas measurements possible. This type of dataset can then be compared to other volcanic observations to provide an in depth picture of degassing mechanisms in the shallow conduit. The goals of this research are to develop a robust methodology for UV camera field measurements of volcanic plumes, and utilize this data in conjunction with seismoacoustic records to illuminate degassing processes. Field and laboratory experiments were conducted to determine the effects of imaging conditions, vignetting, exposure time, calibration technique, and filter usage on the UV camera sulfur dioxide measurements. Using the best practices determined from these studies, a field campaign was undertaken at Volcán de Pacaya, Guatemala. Coincident plume sulfur dioxide measurements, acoustic recordings, and seismic observations were collected and analyzed jointly. The results provide insight into the small explosive features, variations in degassing rate, and plumbing system of this complex volcanic system. This research provides useful information for determining volcanic hazard at Pacaya, and demonstrates the potential of the UV camera in multiparameter studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The capability to detect combustion in a diesel engine has the potential of being an important control feature to meet increasingly stringent emission regulations, develop alternative combustion strategies, and use of biofuels. In this dissertation, block mounted accelerometers were investigated as potential feedback sensors for detecting combustion characteristics in a high-speed, high pressure common rail (HPCR), 1.9L diesel engine. Accelerometers were positioned in multiple placements and orientations on the engine, and engine testing was conducted under motored, single and pilot-main injection conditions. Engine tests were conducted at varying injection timings, engine loads, and engine speeds to observe the resulting time and frequency domain changes of the cylinder pressure and accelerometer signals. The frequency content of the cylinder pressure based signals and the accelerometer signals between 0.5 kHz and 6 kHz indicated a strong correlation with coherence values of nearly 1. The accelerometers were used to produce estimated combustion signals using the Frequency Response Functions (FRF) measured from the frequency domain characteristics of the cylinder pressure signals and the response of the accelerometers attached to the engine block. When compared to the actual combustion signals, the estimated combustion signals produced from the accelerometer response had Root Mean Square Errors (RMSE) between 7% and 25% of the actual signals peak value. Weighting the FRF’s from multiple test conditions along their frequency axis with the coherent output power reduced the median RMSE of the estimated combustion signals and the 95th percentile of RMSE produced from each test condition. The RMSE’s of the magnitude based combustion metrics including peak cylinder pressure, MPG, peak ROHR, and work estimated from the combustion signals produced by the accelerometer responses were between 15% and 50% of their actual value. The MPG measured from the estimated pressure gradient shared a direct relationship to the actual MPG. The location based combustion metrics such as the location of peak values and burn durations were capable of RMSE measurements as low as 0.9°. Overall, accelerometer based combustion sensing system was capable of detecting combustion and providing feedback regarding the in cylinder combustion process

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis covers the correction, and verification, development, and implementation of a computational fluid dynamics (CFD) model for an orifice plate meter. Past results were corrected and further expanded on with compressibility effects of acoustic waves being taken into account. One dynamic pressure difference transducer measures the time-varying differential pressure across the orifice meter. A dynamic absolute pressure measurement is also taken at the inlet of the orifice meter, along with a suitable temperature measurement of the mean flow gas. Together these three measurements allow for an incompressible CFD simulation (using a well-tested and robust model) for the cross-section independent time-varying mass flow rate through the orifice meter. The mean value of this incompressible mass flow rate is then corrected to match the mean of the measured flow rate( obtained from a Coriolis meter located up stream of the orifice meter). Even with the mean and compressibility corrections, significant differences in the measured mass flow rates at two orifice meters in a common flow stream were observed. This means that the compressibility effects associated with pulsatile gas flows is significant in the measurement of the time-varying mass flow rate. Future work (with the approach and initial runs covered here) will provide an indirect verification of the reported mass flow rate measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

1. The evolution of flowering strategies (when and at what size to flower) in monocarpic perennials is determined by balancing current reproduction with expected future reproduction, and these are largely determined by size-specific patterns of growth and survival. However, because of the difficulty in following long-lived individuals throughout their lives, this theory has largely been tested using short-lived species (< 5 years). 2. Here, we tested this theory using the long-lived monocarpic perennial Campanula thyrsoides which can live up to 16 years. We used a novel approach that combined permanent plot and herb chronology data from a 3-year field study to parameterize and validate integral projection models (IPMs). 3. Similar to other monocarpic species, the rosette leaves of C. thyrsoides wither over winter and so size cannot be measured in the year of flowering. We therefore extended the existing IPM framework to incorporate an additional time delay that arises because flowering demography must be predicted from rosette size in the year before flowering. 4. We found that all main demographic functions (growth, survival probability, flowering probability and fecundity) were strongly size-dependent and there was a pronounced threshold size of flowering. There was good agreement between the predicted distribution of flowering ages obtained from the IPMs and that estimated in the field. Mostly, there was good agreement between the IPM predictions and the direct quantitative field measurements regarding the demographic parameters lambda, R-0 and T. We therefore conclude that the model captures the main demographic features of the field populations. 5. Elasticity analysis indicated that changes in the survival and growth function had the largest effect (c. 80%) on lambda and this was considerably larger than in short-lived monocarps. We found only weak selection pressure operating on the observed flowering strategy which was close to the predicted evolutionary stable strategy. 6. Synthesis. The extended IPM accurately described the demography of a long-lived monocarpic perennial using data collected over a relatively short period. We could show that the evolution of flowering strategies in short- and long-lived monocarps seem to follow the same general rules but with a longevity-related emphasis on survival over fecundity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Percutaneous vertebroplasty, comprising an injection of polymethylmethacrylate (PMMA) into vertebral bodies, is a practical procedure for the stabilization of osteoporotic compression fractures as well as other weakening lesions. Cement leakage is considered to be one of the major and most severe complications during percutaneous vertebroplasty. The viscosity of the material plays a key role in this context. In order to enhance the safety for the patient, a rheometer system was developed to measure the cement viscosity intraoperatively. For this development, it is of great importance to know the proper viscosity to start the procedure determined by experienced surgeons and the relation between the time period when different injection devices are used and the cement viscosity. The purpose of the study was to investigate the viscosity ranges for different injection systems during conventional vertebroplasty. Clinically observed viscosity values and related time periods showed high scattering. In order to get a better understanding of the clinical observations, cement viscosity during hardening at different ambient temperatures and by simulation of the body temperature was investigated in vitro. It could be concluded, that the direct viscosity assessment with a rheometer during vertebroplasty can help clinicians to define a lower threshold viscosity and thereby decrease the risk of leakage and make adjustments to their injection technique in real time. Secondly, the acceleration in hardening of PMMA-based cements at body temperature can be useful in minimizing leakages by addressing them with a short injection break.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pulse wave velocity (PWV) is a surrogate of arterial stiffness and represents a non-invasive marker of cardiovascular risk. The non-invasive measurement of PWV requires tracking the arrival time of pressure pulses recorded in vivo, commonly referred to as pulse arrival time (PAT). In the state of the art, PAT is estimated by identifying a characteristic point of the pressure pulse waveform. This paper demonstrates that for ambulatory scenarios, where signal-to-noise ratios are below 10 dB, the performance in terms of repeatability of PAT measurements through characteristic points identification degrades drastically. Hence, we introduce a novel family of PAT estimators based on the parametric modeling of the anacrotic phase of a pressure pulse. In particular, we propose a parametric PAT estimator (TANH) that depicts high correlation with the Complior(R) characteristic point D1 (CC = 0.99), increases noise robustness and reduces by a five-fold factor the number of heartbeats required to obtain reliable PAT measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The assessment of ERa, PgR and HER2 status is routinely performed today to determine the endocrine responsiveness of breast cancer samples. Such determination is usually accomplished by means of immunohistochemistry and in case of HER2 amplification by means of fluorescent in situ hybridization (FISH). The analysis of these markers can be improved by simultaneous measurements using quantitative real-time PCR (Qrt-PCR). In this study we compared Qrt-PCR results for the assessment of mRNA levels of ERa, PgR, and the members of the human epidermal growth factor receptor family, HER1, HER2, HER3 and HER4. The results were obtained in two independent laboratories using two different methods, SYBR Green I and TaqMan probes, and different primers. By linear regression we demonstrated a good concordance for all six markers. The quantitative mRNA expression levels of ERa, PgR and HER2 also strongly correlated with the respective quantitative protein expression levels prospectively detected by EIA in both laboratories. In addition, HER2 mRNA expression levels correlated well with gene amplification detected by FISH in the same biopsies. Our results indicate that both Qrt-PCR methods were robust and sensitive tools for routine diagnostics and consistent with standard methodologies. The developed simultaneous assessment of several biomarkers is fast and labor effective and allows optimization of the clinical decision-making process in breast cancer tissue and/or core biopsies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: CD4 cell count and plasma viral load are well known predictors of AIDS and mortality in HIV-1-infected patients treated with combination antiretroviral therapy (cART). This study investigated, in patients treated for at least 3 years, the respective prognostic importance of values measured at cART initiation, and 6 and 36 months later, for AIDS and death. METHODS: Patients from 15 HIV cohorts included in the ART Cohort Collaboration, aged at least 16 years, antiretroviral-naive when they started cART and followed for at least 36 months after start of cART were eligible. RESULTS: Among 14 208 patients, the median CD4 cell counts at 0, 6 and 36 months were 210, 320 and 450 cells/microl, respectively, and 78% of patients achieved viral load less than 500 copies/ml at 6 months. In models adjusted for characteristics at cART initiation and for values at all time points, values at 36 months were the strongest predictors of subsequent rates of AIDS and death. Although CD4 cell count and viral load at cART initiation were no longer prognostic of AIDS or of death after 36 months, viral load at 6 months and change in CD4 cell count from 6 to 36 months were prognostic for rates of AIDS from 36 months. CONCLUSIONS: Although current values of CD4 cell count and HIV-1 RNA are the most important prognostic factors for subsequent AIDS and death rates in HIV-1-infected patients treated with cART, changes in CD4 cell count from 6 to 36 months and the value of 6-month HIV-1 RNA are also prognostic for AIDS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Plasma and Supra-Thermal Ion Composition (PLASTIC) instrument is one of four experiment packages on board of the two identical STEREO spacecraft A and B, which were successfully launched from Cape Canaveral on 26 October 2006. During the two years of the nominal STEREO mission, PLASTIC is providing us with the plasma characteristics of protons, alpha particles, and heavy ions. PLASTIC will also provide key diagnostic measurements in the form of the mass and charge state composition of heavy ions. Three measurements (E/qk, time of flight, ESSD) from the pulse height raw data are used to characterize the solar wind ions from the solar wind sector, and part of the suprathermal particles from the wide-angle partition with respect to mass, atomic number and charge state. In this paper, we present a new method for flight data analysis based on simulations of the PLASTIC response to solar wind ions. We present the response of the entrance system / energy analyzer in an analytical form. Based on stopping power theory, we use an analytical expression for the energy loss of the ions when they pass through a thin carbon foil. This allows us to model analytically the response of the time of flight mass spectrometer to solar wind ions. Thus we present a new version of the analytical response of the solid state detectors to solar wind ions. Various important parameters needed for our models were derived, based on calibration data and on the first flight measurements obtained from STEREO-A. We used information from each measured event that is registered in full resolution in the Pulse Height Analysis words and we derived a new algorithm for the analysis of both existing and future data sets of a similar nature which was tested and works well. This algorithm allows us to obtain, for each measured event, the mass, atomic number and charge state in the correct physical units. Finally, an important criterion was developed for filtering our Fe raw flight data set from the pulse height data without discriminating charge states.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Parathyroid hormone (PTH) and parathyroid hormone-related protein (PTH-rP) are two potent hypercalcemic hormones that act on the same targets. Autonomous secretion of the former is involved in primary hyperparathyroidism (PHPT), whereas the latter is responsible for humoral hypercalcemia of malignancy (HHM). Methods: From 250 consecutive, hypercalcemic serum samples sent to our laboratory for assessment of intact PTH, we were able to obtain clinical information, as well as an additional plasma sample for PTH-rP measurement, in 134 patients. At the time of sampling, patients could be classified into seven groups: cancer without known bone metastases (CaNoMeta, n=36), cancer with bone metastases (CaMeta, n=9), no evidence of cancer (noEvCa, n=71), sarcoidosis (Sarc, n=3), end-stage renal disease (ESRD, n=12), vitamin D overdose (VIT-D, n=2), and hyperthyroidism (Thyr, n=1). Results: In the CaNoMeta group, 29/36 patients had elevated PTH-rP levels, 9/36 patients had inappropriately elevated PTH levels, and 5/36 had elevated levels of both hormones. In the CaMeta group, three of the nine patients had inappropriately elevated PTH levels, two of them with concomitantly elevated PTH-rP levels. In the NoEvCa group, 63/71 patients had an inappropriate elevation of PTH levels and were diagnosed as having PHPT. Four of the 71 patients had elevated levels of both PTH and PTH-rP; three of them were in poor health and died within a short period of time. All of the ESRD patients had very high PTH and normal PTH-rP levels, except for one woman with high PTH-rP and undetectable PTH levels; she died from what later turned out to be a recurrent bladder carcinoma. In the Sarc, Vit-D, and Thyr groups, both PTH and PTH-rP levels were normal. Conclusions: (1) Elevated PTH-rP levels are a common finding in cancer patients without bone metastases. Intact PTH, however, should always be measured in hypercalcemic patients with malignancy because concurrent primary hyperparathyroidism is not rare. (2) Primary hyperparathyroidism accounts for hypercalcemia in 90% of patients without evidence of cancer whose PTH-rP levels may also be found to be elevated in a few cases, even some with surgically demonstrated parathyroid adenoma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper addresses the problem of service development based on GSM handset signaling. The aim is to achieve this goal without the participation of the users, which requires the use of a passive GSM receiver on the uplink. Since no tool for GSM uplink capturing was available, we developed a new method that can synchronize to multiple mobile devices by simply overhearing traffic between them and the network. Our work includes the implementation of modules for signal recovery, message reconstruction and parsing. The method has been validated against a benchmark solution on GSM downlink and independently evaluated on uplink channels. Initial evaluations show up to 99% success rate in message decoding, which is a very promising result. Moreover, we conducted measurements that reveal insights on the impact of signal power on the capturing performance and investigate possible reactive measures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One hundred eighty-nine mixed breed beef heifers from 13 consignors enrolled in the MACEP heifer development project were utilized in this study. Heifers were synchronized by feeding 0.5 mg melengestrol acetate (MGA) per head per day for 14 days followed by an injection of prostaglandin F2a (PGF2a; 25 mg Lutalyse®) 17 days after the last MGA feeding. Each heifer was fitted with a Heatwatch® transmitter on the morning of PGF2a administration to facilitate detection of estrus. Vaginal conductivity measurements were taken using an Ovatec® probe every 12 hours for 96 hours beginning at the time of PGF2a injection. Heifers randomly assigned to produce a female calf were inseminated near the onset of estrus (as indicated by probe values of £ 55 on the decline). Heifers randomly assigned to produce a male calf were inseminated approximately 24 hours after the onset of estrus (as indicated by probe values of ³ 60 on the incline). All heifers not inseminated by 96 hours after PGF2a were mass inseminated in an attempt to impregnate as many heifers as possible. Heifers that were diagnosed as pregnant as a result of the artificial insemination were subjected to ultrasonography for fetal sex determination. Only 70 of the 189 heifers (37.0%) exhibited estrus according to Heatwatch® and incidence of estrus was influenced by heifer average daily gain, reproductive tract score, and disposition score. Heifers receiving a disposition score of 3 (78.7) had a higher (P<.05) probe reading at AI than those receiving a disposition score of 1 or 2 (70.8 and 72.5, respectively). Heifers with probe readings at insemination of 80 - 84 and > 84 had lower (P<.05) pregnancy rates to AI (13.6 and 0.0%, respectively) than heifers with probe readings in the ranges of < 60, 60 - 64, 65 - 69, 70 - 74, and 75 - 79 (35.7, 40.9, 31.4, 35.3, and 26.9% respectively). Heifers that were bred when probe values were increasing had a lower (P<.05) percentage of male fetuses (34.4%) than those bred during a period of decreasing probe values (69.2% male fetuses). These results demonstrate that a vaginal conductivity probe may be a useful tool to determine an insemination time that could potentially alter calf sex ratio.