949 resultados para Three-dimensional computed tomography
Resumo:
OBJECTIVES: The aim of this phantom study was to evaluate the contrast-to-noise ratio (CNR) in pulmonary computed tomography (CT)-angiography for 300 and 400 mg iodine/mL contrast media using variable x-ray tube parameters and patient sizes. We also analyzed the possible strategies of dose reduction in patients with different sizes. MATERIALS AND METHODS: The segmental pulmonary arteries were simulated by plastic tubes filled with 1:30 diluted solutions of 300 and 400 mg iodine/mL contrast media in a chest phantom mimicking thick, intermediate, and thin patients. Volume scanning was done with a CT scanner at 80, 100, 120, and 140 kVp. Tube current-time products (mAs) varied between 50 and 120% of the optimal value given by the built-in automatic dose optimization protocol. Attenuation values and CNR for both contrast media were evaluated and compared with the volume CT dose index (CTDI(vol)). Figure of merit, calculated as CNR/CTDIvol, was used to quantify image quality improvement per exposure risk to the patient. RESULTS: Attenuation of iodinated contrast media increased both with decreasing tube voltage and patient size. A CTDIvol reduction by 44% was achieved in the thin phantom with the use of 80 instead of 140 kVp without deterioration of CNR. Figure of merit correlated with kVp in the thin phantom (r = -0.897 to -0.999; P < 0.05) but not in the intermediate and thick phantoms (P = 0.09-0.71), reflecting a decreasing benefit of tube voltage reduction on image quality as the thickness of the phantom increased. Compared with the 300 mg iodine/mL concentration, the same CNR for 400 mg iodine/mL contrast medium was achieved at a lower CTDIvol by 18 to 40%, depending on phantom size and applied tube voltage. CONCLUSIONS: Low kVp protocols for pulmonary embolism are potentially advantageous especially in thin and, to a lesser extent, in intermediate patients. Thin patients profit from low voltage protocols preserving a good CNR at a lower exposure. The use of 80 kVp in obese patients may be problematic because of the limitation of the tube current available, reduced CNR, and high skin dose. The high CNR of the 400 mg iodine/mL contrast medium together with lower tube energy and/or current can be used for exposure reduction.
Resumo:
PURPOSE: This retrospective study was conducted to determine whether a low-volume contrast medium protocol provides sufficient enhancement for 64-detector computed tomography angiography (CTA) in patients with aortoiliac aneurysms. METHODS: Evaluated were 45 consecutive patients (6 women; mean age, 72 +/- 6 years) who were referred for aortoiliac computed tomography angiography between October 2005 and January 2007. Group A (22 patients; creatinine clearance, 64.2 +/- 8.1 mL/min) received 50 mL of the contrast agent. Group B (23 patients; creatinine clearance, 89.4 +/- 7.3 mL/min) received 100 mL of the contrast agent. The injection rate was 3.5 mL/s, followed by 30 mL of saline at 3.5 mL/s. Studies were performed on the same 64-detector computed tomography scanner using a real-time bolus-tracking technique. Quantitative analysis was performed by determination of mean vascular attenuation at 10 regions of interest from the suprarenal aorta to the common femoral artery by one reader blinded to type and amount of contrast agent and compared using the Student t test. Image quality according to a 4-point scale was assessed in consensus by two readers blinded to type and amount of contrast medium and compared using the Mann-Whitney test. Multivariable adjustments were performed using ordinal regression analysis. RESULTS: Mean total attenuation did not differ significantly between both groups (196.5 +/- 33.0 Hounsfield unit [HU] in group A and 203.1 +/- 44.2 HU in group B; P = .57 by univariate and P > .05 by multivariable analysis). Accordingly, attenuation at each region of interest was not significantly different (P > .35). Image quality was excellent or good in all patients. No significant differences in visual assessment were found comparing both contrast medium protocols (P > .05 by univariate and by multivariable analysis). CONCLUSIONS: Aortoiliac aneurysm imaging can be performed with substantially reduced amounts of contrast medium using 64-detector computed tomography angiography technology.
Resumo:
The three-dimensional NMR structures of seven octapeptide analogs of somatostatin (SRIF), based on octreotide, with the basic sequence H-Cpa/Phe2-c[DCys3-Xxx7-DTrp/DAph(Cbm)8-Lys9-Thr10-Cys14]-Yyy-NH2 (the numbering refers to the position in native SRIF), with Xxx7 being Aph(Cbm)/Tyr/Agl(NMe,benzoyl) and Yyy being Nal/DTyr/Thr, are presented here. Most of these analogs exhibit potent and highly selective binding to sst2 receptors, and all of the analogs are antagonists inhibiting receptor signaling. Based on their consensus 3D structure, the pharmacophore of the sst2-selective antagonist has been defined. The pharmacophore involves the side chains of Cpa2, DTrp/DAph(Cbm)8, and Lys9, with the backbone for most of the sst2-selective antagonists comprised a Type-II' beta-turn. Hence, the sst2-selective antagonist pharmacophore is very similar to the sst2-selective agonist pharmacophore previously described.
Resumo:
Single-screw extrusion is one of the widely used processing methods in plastics industry, which was the third largest manufacturing industry in the United States in 2007 [5]. In order to optimize the single-screw extrusion process, tremendous efforts have been devoted for development of accurate models in the last fifty years, especially for polymer melting in screw extruders. This has led to a good qualitative understanding of the melting process; however, quantitative predictions of melting from various models often have a large error in comparison to the experimental data. Thus, even nowadays, process parameters and the geometry of the extruder channel for the single-screw extrusion are determined by trial and error. Since new polymers are developed frequently, finding the optimum parameters to extrude these polymers by trial and error is costly and time consuming. In order to reduce the time and experimental work required for optimizing the process parameters and the geometry of the extruder channel for a given polymer, the main goal of this research was to perform a coordinated experimental and numerical investigation of melting in screw extrusion. In this work, a full three-dimensional finite element simulation of the two-phase flow in the melting and metering zones of a single-screw extruder was performed by solving the conservation equations for mass, momentum, and energy. The only attempt for such a three-dimensional simulation of melting in screw extruder was more than twenty years back. However, that work had only a limited success because of the capability of computers and mathematical algorithms available at that time. The dramatic improvement of computational power and mathematical knowledge now make it possible to run full 3-D simulations of two-phase flow in single-screw extruders on a desktop PC. In order to verify the numerical predictions from the full 3-D simulations of two-phase flow in single-screw extruders, a detailed experimental study was performed. This experimental study included Maddock screw-freezing experiments, Screw Simulator experiments and material characterization experiments. Maddock screw-freezing experiments were performed in order to visualize the melting profile along the single-screw extruder channel with different screw geometry configurations. These melting profiles were compared with the simulation results. Screw Simulator experiments were performed to collect the shear stress and melting flux data for various polymers. Cone and plate viscometer experiments were performed to obtain the shear viscosity data which is needed in the simulations. An optimization code was developed to optimize two screw geometry parameters, namely, screw lead (pitch) and depth in the metering section of a single-screw extruder, such that the output rate of the extruder was maximized without exceeding the maximum temperature value specified at the exit of the extruder. This optimization code used a mesh partitioning technique in order to obtain the flow domain. The simulations in this flow domain was performed using the code developed to simulate the two-phase flow in single-screw extruders.
Resumo:
Double fenestration of the anterior communicating artery (ACoA) complex associated with an aneurysm is a very rare finding and is usually caused by ACoA duplication and the presence of a median artery of the corpus callosum (MACC). We present a patient in whom double fenestration was not associated with ACoA duplication or even with MACC, representing therefore, a previously unreported anatomic variation. A 43 year old woman experienced sudden headache and the CT scans showed subarachnoid haemorrhage (SAH). On admission, her clinical condition was consistent with Hunt and Hess grade II. Conventional digital subtraction angiography (DSA) was performed and revealed multiple intracranial aneurysms arising from both middle cerebral arteries (MCA) and from the ACoA. Three-dimensional rotational angiography (3D-RA) disclosed a double fenestration of the ACoA complex which was missed by DSA. The patient underwent a classic pterional approach in order to achieve occlusion of both left MCA and ACoA aneurysms by surgical clipping. The post-operative period was uneventful. A rare anatomical variation characterised by a double fenestration not associated with ACoA duplication or MACC is described. The DSA images missed the double fenestration which was disclosed by 3D-RA, indicating the importance of 3D-RA in the diagnosis and surgical planning of intracranial aneurysms.
Anatomical study of the quadrigeminal cistern in the living with three-dimensional MR cisternography
Resumo:
For human beings, the origin of life has always been an interesting and mysterious matter, particularly how life arose from inorganic matter through natural processes. Polymerization is always involved in such processes. In this paper we built what we refer to as ideal and physical models to simulate spontaneous polymerization based on certain physical principles. As the modeling confirms, without taking external energy, small and simple inorganic molecules formed bigger and more complicated molecules, which are necessary ingredients of all living organisms. In our simulations, we utilized actual ranges of parameters according to their experimentally observed values. The results from the simulations led to a good agreement with the nature of polymerization. After sorting out through all the models that were built, we arrived at a final model that, it is hoped, can be used to simply and efficiently describe spontaneous polymerization using only three parameters: the dipole moment, the distance between molecules, and the temperature.
Resumo:
As the auditory ossicles are difficult to display without harming them in conventional autopsies, lesions of these minute bones and the ossicular chain are regularly missed. In this study, the method of choice in clinical medicine for the examination of such lesions, namely multislice computed tomography, was applied to 100 corpses. The hereby obtained results regarding ossicle luxation and petrous bone fracture indicated that the lesions were not dependant on the amount, but rather on the type of energy inflicted to the head.
Resumo:
Fatal falls from great height are a frequently encountered setting in forensic pathology. They present--by virtue of a calculable energy transmission to the body--an ideal model for the assessment of the effects of blunt trauma to a human body. As multislice computed tomography (MSCT) has proven not only to be invaluable in clinical examinations, but also to be a viable tool in post-mortem imaging, especially in the field of osseous injuries, we performed a MSCT scan on 20 victims of falls from great height. We hereby detected fractures and their distributions were compared with the impact energy. Our study suggests a marked increase of extensive damage to different body regions at about 20 kJ and more. The thorax was most often affected, regardless of the amount of impacting energy and the primary impact site. Cranial fracture frequency displayed a biphasic distribution with regard to the impacting energy; they were more frequent in energies of less than 10, and more than 20 kJ, but rarer in the intermediate energy group, namely that of 10-20 kJ.
Resumo:
Modern cross-sectional imaging techniques are being increasingly implemented in forensic pathology. These methods may serve as an adjuvant to classic forensic autopsies or even replace them altogether in the future. In order to assess the practicability of such a method, namely post-mortem multislice computed tomography (MSCT) in fatal gunshot injuries, 22 corpses underwent such an examination prior to forensic autopsy. The cardinal questions of the location of entrance and exit wounds, the detection of bullets and bullet fragments in the body, the bullet course, inflicted injuries and cause of death were addressed at MSCT and autopsy. The results of the two techniques revealed that post-mortem MSCT can answer these questions reliably and is therefore a useful tool in the assessment of such injuries.
Resumo:
Modern cross-sectional imaging techniques are being increasingly implemented in forensic pathology. In order to assess the practicability of such a method, namely post-mortem multislice computed tomography (MSCT) in cases of fatal cut and stab injuries, 12 corpses underwent such an examination prior to forensic autopsy. The questions regarding detection of foreign bodies, wound channels, skeletal and organ injuries, as well as the cause of death were addressed at MSCT and autopsy. The results of the two techniques revealed that post-mortem MSCT a useful tool in the assessment of such injuries.