911 resultados para Technicolor and Composite Models
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study evaluated the effect of thermocycling on the bond strength between Procera AllCeram (Nobel-Biocare) and a resin cement (Panavia F, Kuraray CO). Nine ceramic blocks with dimensions of 5x6x6mm were conditioned at one face with Rocatec System (Espe). After, they were luted with Panavia F to composite resin blocks (Clearfil AP-X, Kuraray CO). The nine groups formed by ceramic, cement and composite resin were split up obtaining 75 samples with dimensions of 12x1x1mm and adhesive surface presenting 1mm2±0.1mm2 of area. The samples were divided into 3 groups (n=25): G1 - 14 days in distilled water at 37ºC; G2 – 6,000 cycles in water (5ºC - 55ºC – 30s); G3 – 12,000 cycles in water (5ºC - 55ºC – 30s). The samples were tested in a universal testing machine (EMIC) at a crosshead speed of 1mm/min. Data were analyzed by ANOVA and Tukey tests. The results indicated that mean values of rupture tension (MPa) of G1 (10.71 ± 3.54) did not differ statistically (p <5%) from G2 (9.01 ± 3.90), however there was statistical difference between G1 and G3 (7.28 ± 3.00). It was concluded that thermocycling significantly reduced the bond strength values when samples were submitted to 12,000 cycles.
Resumo:
Despite its high incidence, patellofemoral pain etiology remains unclear. No prior study has compared surface electromyography frequency domain parameters and surface electromyography time domain variables, which have been used as a classic analysis of patellofemoral pain. Thirty one women with patellofemoral pain and twenty eight pain-free women were recruited. Each participant was asked to descend a seven step staircase and data from five successful trials were collected. During the task, the vastus medialis and vastus lateralis muscle activities were monitored by surface electromyography. The data were processed and analyzed in four variables of the frequency domain (median frequency, low, medium and high frequency bands) and three time domain variables (Automatic, Cross-correlation and Visual Onset between the vastus medialis and vastus lateralis muscles). Reliability, Receiver Operating Characteristic curves and regression models were performed. The medium frequency band was the most reliable variable and different between the groups for both muscles, also demonstrated the best values of sensitivity and sensibility, 72% and 69% for the vastus medialis and 68% and 62% for the vastus lateralis, respectively. The frequency variables predicted the pain of individuals with patellofemoral pain, 26% for the vastus medialis and 20% for the vastus lateralis, being better than the time variables, which achieved only 7%. The frequency domain parameters presented greater reliability, diagnostic accuracy and capacity to predict pain than the time domain variables during stair descent and might be a useful tool to diagnose individuals with patellofemoral pain.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Environmental data are spatial, temporal, and often come with many zeros. In this paper, we included space–time random effects in zero-inflated Poisson (ZIP) and ‘hurdle’ models to investigate haulout patterns of harbor seals on glacial ice. The data consisted of counts, for 18 dates on a lattice grid of samples, of harbor seals hauled out on glacial ice in Disenchantment Bay, near Yakutat, Alaska. A hurdle model is similar to a ZIP model except it does not mix zeros from the binary and count processes. Both models can be used for zero-inflated data, and we compared space–time ZIP and hurdle models in a Bayesian hierarchical model. Space–time ZIP and hurdle models were constructed by using spatial conditional autoregressive (CAR) models and temporal first-order autoregressive (AR(1)) models as random effects in ZIP and hurdle regression models. We created maps of smoothed predictions for harbor seal counts based on ice density, other covariates, and spatio-temporal random effects. For both models predictions around the edges appeared to be positively biased. The linex loss function is an asymmetric loss function that penalizes overprediction more than underprediction, and we used it to correct for prediction bias to get the best map for space–time ZIP and hurdle models.
Resumo:
As the area of nanotechnology continues to grow, the development of new nanomaterials with interesting physical and electronic properties and improved characterization techniques are several areas of research that will be remain vital for continued improvement of devices and the understanding in nanoscale phenomenon. In this dissertation, the chemical vapor deposition synthesis of rare earth (RE) compounds is described in detail. In general, the procedure involves the vaporization of a REClx (RE = Y, La, Ce, Pr, Nd, Sm, Gd, Tb, Dy, Ho) in the presence of hydride phase precursors such as decaborane and ammonia at high temperatures and low pressures. The vapor-liquid-solid mechanism was used in combination with the chemical vapor deposition process to synthesize single crystalline rare earth hexaboride nanostructures. The crystallographic orientation of as-synthesized rare earth hexaboride nanostructures and gadolinium nitride thin films was controlled by judicious choice of specific growth substrates and modeled by analyzing x-ray diffraction powder patterns and crystallographic models. The rare earth hexaboride nanostructures were then implemented into two existing technologies to enhance their characterization capabilities. First, the rare earth hexaboride nanowires were used as a test material for the development of a TEM based local electrode atom probe tomography (LEAP) technique. This technique provided some of the first quantitative compositional information of the rare earth hexaboride systems. Second, due to the rigidity and excellent conductivity of the rare earth hexaborides, nanostructures were grown onto tungsten wires for the development of robust, oxidation resistant nanomanipulator electronic probes for semiconductor device failure analysis.
Resumo:
Lessons from around the world; What does it matter about early childhood education? Why the controversy about public support for early childhood education? What process or system should be used to determine what works in early education? Can the same process be used to improve services? What is the role of government? Alternatives: 1. Consumers should determine… (What happens when private choices drive the market for early childhood services?) Observed quality of care in four Midwestern states; Parent data: “All things considered, how would you grade the quality of the care your child is receiving from his/her current caregiver?” Role of government What is a Quality Rating System? Ten states have implemented statewide systems (e.g. Colorado, Kentucky, Oklahoma, North Carolina) Findings 2. Objective science should determine… Firm findings from empirical research 3. Something else is needed: Some differences between Italian and American models. Teacher action research (and documentation) from a Reggio-inspired preschool in South Korea by Misuk Kim. Teacher Action Research at the Ruth Staples CDL. Can we now answer our opening questions? What process or system should be used to determine what is best for young children? Can the same process be used to improve the quality of services? Conclusions: The free market does not work well to determine quality in early education and care; Licensing, accreditation, and quality rating systems can help improve the market; Empirical research is useful for measuring what works; Teacher action research (reflective practice) is necessary for fostering continuous quality improvement. The tower of quality.
Resumo:
Contamination by butyltin compounds (BTs) has been reported in estuarine environments worldwide, with serious impacts on the biota of these areas. Considering that BTs can be degraded by varying environmental conditions such as incident light and salinity, the short-term variations in such factors may lead to inaccurate estimates of BTs concentrations in nature. Therefore, the present study aimed to evaluate the possibility that measurements of BTs in estuarine sediments are influenced by different sampling conditions, including period of the day (day or night), tidal zone (intertidal or subtidal), and tides (high or low). The study area is located on the Brazilian southeastern coast, Sao Vicente Estuary, at Pescadores Beach, where BT contamination was previously detected. Three replicate samples of surface sediment were collected randomly in each combination of period of the day, tidal zone, and tide condition, from three subareas along the beach, totaling 72 samples. BTs were analyzed by GC-PFPD using a tin filter and a VF-5 column, by means of a validated method. The concentrations of tributyltin (TBT), dibutyltin (DBT), and monobutyltin (MBT) ranged from undetectable to 161 ng Sn g(-1) (d.w.). In most samples (71%), only MBT was quantifiable, whereas TBTs were measured in only 14, suggesting either an old contamination or rapid degradation processes. DBT was found in 27 samples, but could be quantified in only one. MBT concentrations did not differ significantly with time of day, zones, or tide conditions. DBT and TBT could not be compared under all these environmental conditions, because only a few samples were above the quantification limit. Pooled samples of TBT did not reveal any difference between day and night. These results indicated that, in assessing contamination by butyltin compounds, surface-sediment samples can be collected in any environmental conditions. However, the wide variation of BTs concentrations in the study area, i.e., over a very small geographic scale, illustrates the need for representative hierarchical and composite sampling designs that are compatible with the multiscalar temporal and spatial variability common to most marine systems. The use of such sampling designs will be necessary for future attempts to quantitatively evaluate and monitor the occurrence and impact of these compounds in nature
Resumo:
Objectives. To verify the hypothesis that crack analysis and a mechanical test would rank a series of composites in a similar order with respect to polymerization stress. Also, both tests would show similar relationships between stress and composite elastic modulus and/or shrinkage. Methods. Soda-lime glass discs (2-mm thick) with a central perforation (3.5-mm diameter) received four Vickers indentations 500 mu m from the cavity margin. The indent cracks were measured (500x) prior and 10 min after the cavity was restored with one of six materials (Kalore/KL, Gradia/GR, Ice/IC, Wave/WV, Majesty Flow/MF, and Majesty Posterior/MP). Stresses at the indent site were calculated based on glass fracture toughness and increase in crack length. Stress at the bonded interface was calculated using the equation for an internally pressurized cylinder. The mechanical test used a universal testing machine and glass rods (5-mm diameter) as substrate. An extensometer monitored specimen height (2 mm). Nominal stress was calculated dividing the maximum shrinkage force by the specimen cross-sectional area. Composite elastic modulus was determined by nanoindentation and post-gel shrinkage was measured using strain gages. Data were subjected to one-way ANOVA/Tukey or Kruskal-Wallis/Mann-Whitney tests (alpha: 5%). Results. Both tests grouped the composites in three statistical subsets, with small differences in overlapping between the intermediate subset (MF, WV) and the highest (MP, IC) or the lowest stress materials (KL, GR). Higher stresses were developed by composites with high modulus and/or high shrinkage. Significance. Crack analysis demonstrated to be as effective as the mechanical test to rank composites regarding polymerization stress. (c) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Background: Lynch syndrome (LS) is the most common form of inherited predisposition to colorectal cancer (CRC), accounting for 2-5% of all CRC. LS is an autosomal dominant disease characterized by mutations in the mismatch repair genes mutL homolog 1 (MLH1), mutS homolog 2 (MSH2), postmeiotic segregation increased 1 (PMS1), post-meiotic segregation increased 2 (PMS2) and mutS homolog 6 (MSH6). Mutation risk prediction models can be incorporated into clinical practice, facilitating the decision-making process and identifying individuals for molecular investigation. This is extremely important in countries with limited economic resources. This study aims to evaluate sensitivity and specificity of five predictive models for germline mutations in repair genes in a sample of individuals with suspected Lynch syndrome. Methods: Blood samples from 88 patients were analyzed through sequencing MLH1, MSH2 and MSH6 genes. The probability of detecting a mutation was calculated using the PREMM, Barnetson, MMRpro, Wijnen and Myriad models. To evaluate the sensitivity and specificity of the models, receiver operating characteristic curves were constructed. Results: Of the 88 patients included in this analysis, 31 mutations were identified: 16 were found in the MSH2 gene, 15 in the MLH1 gene and no pathogenic mutations were identified in the MSH6 gene. It was observed that the AUC for the PREMM (0.846), Barnetson (0.850), MMRpro (0.821) and Wijnen (0.807) models did not present significant statistical difference. The Myriad model presented lower AUC (0.704) than the four other models evaluated. Considering thresholds of >= 5%, the models sensitivity varied between 1 (Myriad) and 0.87 (Wijnen) and specificity ranged from 0 (Myriad) to 0.38 (Barnetson). Conclusions: The Barnetson, PREMM, MMRpro and Wijnen models present similar AUC. The AUC of the Myriad model is statistically inferior to the four other models.
Resumo:
BACKGROUND: In Brazil nationally representative donor data are limited on human immunodeficiency virus (HIV) prevalence, incidence, and residual transfusion risk. The objective of this study was to analyze HIV data obtained over 24 months by the Retrovirus Epidemiology Donor Study-II program in Brazil. STUDY DESIGN AND METHODS: Donations reactive to third-and fourth-generation immunoassays (IAs) were further confirmed by a less-sensitive (LS) IA algorithm and Western blot (WB). Incidence was calculated for first-time (FT) donors using the LS-EIA results and for repeat donors with a model developed to include all donors with a previous negative donation. Residual risk was projected by multiplying composite FT and repeat donor incidence rates by HIV marker-negative infectious window periods. RESULTS: HIV prevalence among FT donors was 92.2/ 105 donations. FT and repeat donor and composite incidences were 38.5 (95% confidence interval [CI], 25.651.4), 22.5 (95% CI, 17.6-28.0), and 27.5 (95% CI, 22.0-33.0) per 100,000 person-years, respectively. Male and community donors had higher prevalence and incidence rates than female and replacement donors. The estimated residual risk of HIV transfusion transmission was 11.3 per 106 donations (95% CI, 8.4-14.2), which could be reduced to 4.2 per 106 donations (95% CI, 3.2-5.2) by use of individual-donation nucleic acid testing (NAT). CONCLUSION: The incidence and residual transfusion risk of HIV infection are relatively high in Brazil. Implementation of NAT will not be sufficient to decrease transmission rates to levels seen in the United States or Europe; therefore, other measures focused on decreasing donations by at-risk individuals are also necessary.
Resumo:
Objective: To analyze the association between maternal obesity and postnatal infectious complications in high-risk pregnancies. Methods: Prospective study from August 2009 through August 2010 with the following inclusion criteria: women up to the 5th postpartum day; age L 18 years; high-risk pregnancy; singleton pregnancy with live fetus at labor onset; delivery at the institution; maternal weight measured on day of delivery. The nutritional status in late pregnancy was assessed by the body mass index (BMI), with the application of the Atalah et al. curve. Patients were graded as underweight, adequate weight, overweight, or obese. Postpartum complications investigated during the hospital stay and 30 days post-discharge were: surgical wound infection and/or secretion, urinary infection, postpartum infection, fever, hospitalization, antibiotic use, and composite morbidity (at least one of the complications mentioned). Results: 374 puerperal women were included, graded according to the final BMI as: underweight (n = 54, 14.4%); adequate weight (n = 126, 33.7%); overweight (n = 105, 28.1%); and obese (n = 89, 23.8%). Maternal obesity was shown to have a significant association with the following postpartum complications: surgical wound infection (16.7%, p = 0.042), urinary infection (9.0%, p = 0.004), antibiotic use (12.3%, p < 0.001), and composite morbidity (25.6%, p = 0.016). By applying the logistic regression model, obesity in late pregnancy was found to be an independent variable regardless of the composite morbidity predicted (OR: 2.09; 95% CI: 1.15-3.80, p = 0.015). Conclusion: Maternal obesity during late pregnancy in high-risk patients is independently associated with postpartum infectious complications, which demonstrates the need for a closer follow-up of maternal weight gain in these pregnancies.