860 resultados para Surgery, Operative.
Resumo:
Aim: Clinical data are scarce on flapless-guided surgery in the mandible using the all-on-four concept. In addition, limited documentation exists on the latter under immediate loading conditions with a pre-fabricated implant bridge. The aim was to provide detailed documentation focusing on clinical and radiographic outcome and complications. Material and methods: Sixteen systemically healthy non-smoking patients (10 women, 6 men, average age 59 years) with sufficient bone volume in the mandible were operated via flapless-guided surgery using the all-on-four concept. Clinical and radiographic data and complications were registered at 3, 6 and 12 months. Results: The overall implant survival rate was 90% with a trend for higher failure of short implants (P = 0.098). The mean bone level after 12 months of function was 0.83 mm with a maximum of 1.07 mm. Technical complications were common (15/16 patients). These mainly related to a misfit between the pre-fabricated prosthesis and abutment(s) (13/16 patients). Conclusion: If immediate loading of implants is pursued fabrication of the implant bridge should be based on actual impression of the implants at the time of surgery and not on their virtual position. © 2011 John Wiley & Sons A/S.
Resumo:
Background: The aim of this study was to compare the rates of local postoperative complications among women undergoing modified radical mastectomy with an electric scalpel (ES) or a harmonic scalpel (HS). It is thought that HS use has less postoperative complications, mainly seroma formation. Methods: This study was a prospective non-randomised clinical trial (NCT01391988) among consecutive patients, performed in parallel. Patients underwent modified radical mastectomy using an HS or ES. We analysed the following operative variables: time, blood loss and seroma volume drainage. Postoperative complications, including seroma, flap necrosis, haematoma and infection were evaluated on the 7th and 14th days. Results: Forty-six patients underwent a MRM with ES and 49 with HS; no differences were observed between the groups. The rate of local complications was 29% in the HS group and 52% in the ES group (p=0.024). The rates of seroma (16.3% versus 28.3%; p=0.161), necrosis (4.1% vs. 21.7%; p=0.013; OR=0.15), haematoma (2.0% vs. 8.7%; p=0.195) and infection (2.0% vs. 6.5%; p=0.351) were lower in the HS group. Adding the findings of all comparative studies using HSs in MRM to the seroma rates in the current study, the seroma rate, expressed as a categorical variable, did not decrease with HS. Seroma was present in 60/219 cases using an HS and in 69/239 cases utilising an ES (p=0.72). Based on a multivariate analysis, HS decreased the risk of skin necrosis (p=0.015). Conclusions: HSs do not decrease the seroma rate. However, this method may be useful in skin sparing mastectomy because it decreases skin flap necrosis. © 2013 Surgical Associates Ltd.
Resumo:
PURPOSE: The present case describes an inferior alveolar nerve lateralization for implant placement that caused mandible fracture a few days after surgery. CLINICAL REPORT: In this case, a 56-year-old female patient who had a severely atrophied jaw and showing bone height less than 7 mm from the bone crest and the mandibular canal was submitted to surgery lateralization of the inferior alveolar conducted with piezzo. Even with all postoperative care, the patient suffered an incomplete fracture of the mandible a few days after lateralization of the inferior alveolar nerve for implant placement. The patient was treated with soft diet and medications for pain and antibiotics, besides removing the implant associated with the fracture. CONCLUSION: It is suggested that this procedure may be conducted in 2 operative periods: firstly, the lateralization of the inferior alveolar; and secondly, after a period of 3 months, the implant placement in a situation of more bone stability. Copyright © 2013 by Mutaz B. Habal, MD.
Resumo:
Background: Intraperitoneal adhesions are common in equines, especially following exploratory celiotomy. Adhesiolysis is the treatment of choice for patients presenting postsurgical adhesions. Laparoscopic approach for adhesiolysis presents several advantageous aspects in human patients. The aim of the current study was to report a case of successful laparoscopic adhesiolysis in a mini pony horse. Case: A male Shetland Pony, weighing 140 kg, was admitted under complaint of right hind limb trauma and treated surgically for metatarsal fracture reduction. The patient has also had intermittent episodes of colic and was always treated clinically without major complications. The pony had no history of previous abdominal surgery and no episodes of acute abdomen were seen during hospital stay. Three months following ostheosynthesis, an exploratory laparoscopic approach was carried out to assess the possible cause or consequences of the episodes of acute abdomen. The patient was submitted to general anesthesia, positioned in dorsal recumbency and the abdomen was clipped and aseptically prepared for surgery. During the laparoscopic inspection, there were adhesions involving the ventral abdominal wall and a ventral mesogastric segment of duodenum. Laparoscopic adhesiolysis was performed using a two-port approach, by gently breaking the adhesion bands using meticulous traction with a 10-mm laparoscopic atraumatic Babcock forceps. Afterwards, the intestinal loop was rinsed with heparin sodium solution diluted in normal saline. The pneumoperitoneum was completely drained and the trocars sequentially withdrawn from the abdominal wall. The synthesis of the muscular layer was carried out using an interrupted cross mattress pattern, followed by synthesis of the skin with an interrupted cushion pattern. Total surgical time was 58 min. the patient was able to recover without complications. In the early postoperative period, the surgical recovery was considered excellent. No apparent adhesion involving the previously affected intestinal loop was found during the ultrasound exam following 15 days of surgery. Furthermore, the surgical wounds had healed completely, with no complications. Discussion: In the current case report, the primary cause of the acute abdomen episodes was not determined since the patient had never undergone abdominal surgery. It was hypothesized that an acute inflammation of the duodenal loop that was involved by the adhesion bands may have triggered the adhesiogenesis. Laparoscopy was efficient and presented a short operative time, due to magnification of image and adequate observation of structures surrounded by adhesion bands. Although the use of Babcock forceps is not usually recommended for adhesiolysis in the current literature, it was both effective in manipulating the bowel and performing the adhesiolysis. The heparin solution diluted in normal saline was effective in preventing the recurrence of new adhesions, which was evidenced by ultrasonography following 15 days. The laparoscopic approach usually minimizes the new formation of adhesions as trauma to the peritoneal surfaces is minimized by the use of delicate instruments, as observed in the current study. In addition, laparoscopy reduces the possibility of contact among the peritoneal surfaces and foreign bodies, such as gauze, glove powder and room air particles. Moreover, it maintains the abdominal surfaces in adequate humidity environment.
Resumo:
This study aimed to evaluate the post operative analgesic effects of morphine or ketamine alone or their combination in 24 healthy bitches, weighing 11.01±8.69kg and aging 27±17 months, submitted to elective ovariohysterectomy. The animals were distributed to one of the three treatments after the anaesthetic induction: morphine (GM, n=8, 0.5mg kg-1 IM), ketamine (GK, n=8, 2.5mg kg-1 IM) or ketamine combined to morphine (GKM) using the same doses previously described. Sedation score and pain assessment were performed blindly two hours before surgery and at 1, 2, 4, 8, 12, and 24 hours after extubation, using the Dobbins scale (sedation) and visual analogue scale (pain) and Glasgow modified pain scale (GMPS). Rescue analgesia was performed with 1.0mg kg-1 of morphine and if not sufficient, followed by 0.2mg kg-1 of meloxicam, both IM, when the GMPS reached above 33% of the total score. Non parametric data were analyzed using Friedmańs test followed by Dunńs test for differences in time. Kruskal-Walliś test followed by Dunńs test were used to investigate differences in the number of analgesic rescues and among groups at each time. Parametric data were evaluated by ANOVA followed by Tukey's test (P<0.05). Except for GMPS, where the values of GM were greater than for GKM at 1h post-extubation, there were no other differences among groups. The number of rescue analgesia was greater in GM (11 in total; twice in 3 animals,) when compared to GKM (3; twice in 1 animal) and GK (2; twice in 1 animal). Analgesia provided by pre-incisional ketamine was more effective when compared to morphine. According to that, ketamine alone may be used as a preemptive analgesic in bitches undergoing ovariohysterectomy; however, rescue analgesia may be necessary.
Resumo:
The aim of this paper was to report the diagnosis and evaluation of periradicular bone repair by using computed tomography and digital subtraction radiography in an endodontic surgery case treated with mineral trioxide aggregate (MTA). The patient had local swelling and fistula 7years after trauma in the upper jaw. Periapical lesion on tooth #12 and root resorption of tooth #11 were detected radiographically. Endodontic therapy and placement of intracanal medication were carried out. After 3months, with no improvement in the clinical signs and symptoms, computed tomography was performed, showing extensive apical bone resorption on tooth #12 and dental resorption promoting communication of the root canal with the periodontium of tooth #11. The patient was referred to endodontic surgery. After surgery and postoperative periods of 15, 30, 60, 90, and 120days, standardized radiographs were taken, digitized, and subjected to digital subtraction of the images using Adobe Photoshop CS software. Four years later, a cone-beam computed tomography was performed, showing bone repair and absence of root resorption at tooth #11. In this clinical case, digital subtraction radiography was effective for early detection of new bone formation and evolution of repair. © 2011 John Wiley & Sons A/S.
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)