936 resultados para SUPERCRITICAL-FLUID CHROMATOGRAPHY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Considering the microbial safety of consumption of raw foods (Asian food), this study aimed to explore the inactivation S. aureus in raw salmon by supercritical CO2 treatment (SC-CO2). For this purpose, experimental design methodology was employed as a tool to evaluate the effects of pressure (120-220 bar), the depressurization rate (10 to 100 bar.min–1) and the salmon:CO2 mass relation (1:0.2 to 1:1.0). It was observed that the pressure and the depressurization rate was statistically significant, i.e. the higher the system pressure and depressurization rate, the greater the microbial inactivation. The salmon: CO2 mass relation did not influence the S. aureus inactivation in raw salmon. There was a total reduction in S. aureus with 225 bar, a depressurizing rate of 100 bar.min–1, a salmon: CO2 mass relation of 1:0.6, for 2 hours at 33 °C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this thesis is to find and analyze different methods which reduce fluid bed boilers’ auxiliary power consumption. The objective is to examine the effects and feasibility of these methods. The literature part explains how fluid bed boilers work and what are the main sources of auxiliary power consumption. Designs and operation of these equipment are presented. The literature part also discusses the basics of auxiliary power consumption reduction and introduces four low pressure drop constructions. The experimental part inspects six different methods. Effects of these methods on the auxiliary power consumption are calculated and their impacts on the operation of the boiler are modeled. Calculations show that reasonable changes can reduce fluid bed boiler’s auxiliary power consumption by 2,1-10,2 %. Biggest reductions come from lower air coefficients, smaller bed a-level pressures and lower primary/secondary air –ratios. Models showed no problems with the smaller bed a-level pressures. With the lower air coefficients and smaller primary/secondary air –ratios the models showed a significant increase in the carbon monoxide levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lipids were extracted from Chlorella algae with supercritical hexane. The high lipids yield of approximately 10% was obtained at optimum conditions of 300 rpm stirring speed and 2 h duration compared to the total contents of lipids being 12%. Furthermore, an easiness of hexane recovery may be considered as economically and ecologically attractive. For the first time, in the current work catalytic hydrodeoxygenation (HDO) of Chlorella algal lipids was studied over 5 wt% Ni/H-Y-80 and 5 wt% Ni/SiO2 at 300 C and under 30 bar total pressure in H2. A comparative HDO of stearic acid was carried out under similar conditions. The conversion of lipids was about 35% over 5 wt% Ni/H-Y-80 after 6h, whereas, 5 wt% Ni/SiO2 was totally deactivated after 60 min. The selectivity to hydrocarbons (C15-C18) is 6%. As a comparison, complete conversion of stearic acid over 5 wt% Ni/H-Y-80 was achieved in 6 h. The transformation of lipids proceeded mostly via hydrogenation and hydrolysis with formation of free fatty acid (FFA). The lower activity might be attributed to deactivation of catalysts caused by chlorophylls and carotenoids. Even though the conversion is low, future studies in HDO of lipids extracted from other algae species having higher lipid content could be proposed. Coke resistant catalyst might be considered to improve catalytic activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluid handling systems account for a significant share of the global consumption of electrical energy. They also suffer from problems, which reduce their energy efficiency and increase life-cycle costs. Detecting or predicting these problems in time can make fluid handling systems more environmentally and economically sustainable to operate. In this Master’s Thesis, significant problems in fluid systems were studied and possibilities to develop variable-speed-drive-based detection methods for them was discussed. A literature review was conducted to find significant problems occurring in fluid handling systems containing pumps, fans and compressors. To find case examples for evaluating the feasibility of variable-speed-drive-based methods, queries were sent to industrial companies. As a result of this, the possibility to detect heat exchanger fouling with a variable-speed drive was analysed with data from three industrial cases. It was found that a mass flow rate estimate, which can be generated with a variable speed drive, can be used together with temperature measurements to monitor a heat exchanger’s thermal performance. Secondly, it was found that the fouling-related increase in the pressure drop of a heat exchanger can be monitored with a variable speed drive. Lastly, for systems where the flow device is speed controlled with by a pressure measurement, it was concluded that increasing rotational speed can be interpreted as progressing fouling in the heat exchanger.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluid inteliigence has been defined as an innate ability to reason which is measured commonly by the Raven's Progressive Matrices (RPM). Individual differences in fluid intelligence are currently explained by the Cascade model (Fry & Hale, 1996) and the Controlled Attention hypothesis (Engle, Kane, & Tuholski, 1999; Kane & Engle, 2002). The first theory is based on a complex relation among age, speed, and working memory which is described as a Cascade. The alternative to this theory, the Controlled Attention hypothesis, is based on the proposition that it is the executive attention component of working memory that explains performance on fluid intelligence tests. The first goal of this study was to examine whether the Cascade model is consistent within the visuo-spatial and verbal-numerical modalities. The second goal was to examine whether the executive attention component ofworking memory accounts for the relation between working memory and fluid intelligence. Two hundred and six undergraduate students between the ages of 18 and 28 completed a battery of cognitive tests selected to measure processing speed, working memory, and controlled attention which were selected from two cognitive modalities, verbalnumerical and visuo-spatial. These were used to predict performance on two standard measures of fluid intelligence: the Raven's Progressive Matrices (RPM) and the Shipley Institute of Living Scales (SILS) subtests. Multiple regression and Structural Equation Modeling (SEM) were used to test the Cascade model and to determine the independent and joint effects of controlled attention and working memory on general fluid intelligence. Among the processing speed measures only spatial scan was related to the RPM. No other significant relations were observed between processing speed and fluid intelligence. As 1 a construct, working memory was related to the fluid intelligence tests. Consistent with the predictions for the RPM there was support for the Cascade model within the visuo-spatial modality but not within the verbal-numerical modality. There was no support for the Cascade model with respect to the SILS tests. SEM revealed that there was a direct path between controlled attention and RPM and between working memory and RPM. However, a significant path between set switching and RPM explained the relation between controlled attention and RPM. The prediction that controlled attention mediated the relation between working memory and RPM was therefore not supported. The findings support the view that the Cascade model may not adequately explain individual differences in fluid intelligence and this may be due to the differential relations observed between working memory and fluid intelligence across different modalities. The findings also show that working memory is not a domain-general construct and as a result its relation with fluid intelligence may be dependent on the nature of the working memory modality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The primary purpose of the current investigation was to develop an elevated muscle fluid level using a human in-vivo model. The secondary purpose was to determine if an increased muscle fluid content could alter the acute muscle damage response following a bout of eccentric exercise. Eight healthy, recreationally active males participated in a cross-over design involving two randomly assigned trials. A hydration trial (HYD) consisting of a two hour infusion of a hypotonic (0.45%) saline at a rate of 20mL/minVl .73m"^ and a control trial (CON), separated by four weeks. Following the infusion (HYD) or rest period (CON), participants completed a single leg isokinetic eccentric exercise protocol of the quadriceps, consisting of 10 sets of 10 repetitions with a one minute rest between each set. Muscle biopsies were collected prior to the exercise, immediately following and at three hours post exercise. Muscle analysis included determination of wet-dry ratios and quantification of muscle damage using toluidine blue staining and light microscopy. Blood samples were collected prior to, immediately post, three and 24 hours post exercise to determine changes in creatine kinase (CK), lactate dehydrogenase (LD), interleukin-6 (IL-6) and Creactive protein (CRP) levels. Results demonstrated an increased muscle fluid volume in the HYD condition following the infusion when compared to the CON condition. Isometric peak torque was significantly reduced following the exercise in both the HYD and CON conditions. There were no significant differences in the number of areas of muscle damage at any of the time points in either condition, with no differences between conditions. CK levels were significantly greater 24hour post exercise compared to pre, immediately and three hours post similarly in both conditions. LD in the HYD condition followed a similar trend as CK with 24 hour levels higher than pre, immediately post and three hours post and LD levels were significantly greater 24 hours post compared to pre levels in the CON condition, with no differences between conditions. A significant main effect for time was observed for CRP (p<0.05) for time, such that CRP levels increased consistently at each subsequent time point. However, CRP and IL-6 levels were not different at any of the measured time points when comparing the two conditions. Although the current investigation was able to successfully increase muscle fluid volume and an increased CK, LD and CRP were observed, no muscle damage was observed following the eccentric exercise protocol in the CON or HYD conditions. Therefore, the hypotonic infusion used in the HYD condition proved to be a viable method to acutely increase muscle fluid content in in-vivo human skeletal muscle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several automated reversed-phase HPLC methods have been developed to determine trace concentrations of carbamate pesticides (which are of concern in Ontario environmental samples) in water by utilizing two solid sorbent extraction techniques. One of the methods is known as on-line pre-concentration'. This technique involves passing 100 milliliters of sample water through a 3 cm pre-column, packed with 5 micron ODS sorbent, at flow rates varying from 5-10 mUmin. By the use of a valve apparatus, the HPLC system is then switched to a gradient mobile phase program consisting of acetonitrile and water. The analytes, Propoxur, Carbofuran, Carbaryl, Propham, Captan, Chloropropham, Barban, and Butylate, which are pre-concentrated on the pre-column, are eluted and separated on a 25 cm C-8 analytical column and determined by UV absorption at 220 nm. The total analytical time is 60 minutes, and the pre-column can be used repeatedly for the analysis of as many as thirty samples. The method is highly sensitive as 100 percent of the analytes present in the sample can be injected into the HPLC. No breakthrough of any of the analytes was observed and the minimum detectable concentrations range from 10 to 480 ng/L. The developed method is totally automated for the analysis of one sample. When the above mobile phase is modified with a buffer solution, Aminocarb, Benomyl, and its degradation product, MBC, can also be detected along with the above pesticides with baseline resolution for all of the analytes. The method can also be easily modified to determine Benomyl and MBC both as solute and as particulate matter. By using a commercially available solid phase extraction cartridge, in lieu of a pre-column, for the extraction and concentration of analytes, a completely automated method has been developed with the aid of the Waters Millilab Workstation. Sample water is loaded at 10 mL/min through a cartridge and the concentrated analytes are eluted from the sorbent with acetonitrile. The resulting eluate is blown-down under nitrogen, made up to volume with water, and injected into the HPLC. The total analytical time is 90 minutes. Fifty percent of the analytes present in the sample can be injected into the HPLC, and recoveries for the above eight pesticides ranged from 84 to 93 percent. The minimum detectable concentrations range from 20 to 960 ng/L. The developed method is totally automated for the analysis of up to thirty consecutive samples. The method has proven to be applicable to both purer water samples as well as untreated lake water samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method using L-cysteine for the determination of arsenous acid (As(III)), arsenic acid (As(V)), monomethylarsonic acid (MMAA), and dimethylarsinic acid (DMAA) by hydride generation was demonstrated. The instrument used was a d.c. plasma atomic emission spectrometer (OCP-AES). Complete recovery was reported for As(III), As(V), and DMAA while 86% recovery was reported for MMAA. Detection limits were determined, as arsenic for the species listed previously, to be 1.2, 0.8, 1.1, and 1.0 ngemL-l, respectively. Precision values, at 50 ngemL-1 arsenic concentration, were f.80/0, 2.50/0, 2.6% and 2.6% relative standard deviation, respectively. The L-cysteine reagent was compared directly with the conventional hydride generation technique which uses a potassium iodide-hydrochloric acid medium. Recoveries using L-cysteine when compared with the conventional method provided the following results: similar recoveries were obtained for As(III), slightly better recoveries were obtained for As(V) and MMAA, and significantly better recoveries for DMAA. In addition, tall and sharp peak shapes were observed for all four species when using L-cysteine. The arsenic speciation method involved separation by ion exchange .. high perfonnance liquid chromatography (HPLC) with on-line hydride generation using the L.. cysteine reagent and measurement byOCP-AES. Total analysis time per sample was 12 min while the time between the start of subsequent runs was approximately 20 min. A binary . gradient elution program, which incorporated the following two eluents: 0.01 and 0.5 mM tri.. sodium citrate both containing 5% methanol (v/v) and both at a pH of approximately 9, was used during the separation by HPLC. Recoveries of the four species which were measured as peak area, and were normalized against As(III), were 880/0, 290/0, and 40% for DMAA, MMAA and As(V), respectively. Resolution factors between adjacent analyte peaks of As(III) and DMAA was 1.1; DMAA and MMAA was 1.3; and MMAA and As(V) was 8.6. During the arsenic speciation study, signals from the d.c. plasma optical system were measured using a new photon-signal integrating device. The_new photon integrator developed and built in this laboratory was based on a previously published design which was further modified to reflect current available hardware. This photon integrator was interfaced to a personal computer through an AID convertor. The .photon integrator has adjustable threshold settings and an adjustable post-gain device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Factors affecting the detennination of PAHs by capillary GC/MS were studied. The effect of the initial column temperature and the injection solvent on the peak areas and heights of sixteen PAHs, considered as priority pollutants, USillg crosslinked methyl silicone (DB!) and 5% diphenyl, 94% dimethyl, 1% vinyl polysiloxane (DBS) columns was examined. The possibility of using high boiling point alcohols especially butanol, pentanol, cyclopentanol, and hexanol as injection solvents was investigated. Studies were carried out to optimize the initial column temperature for each of the alcohols. It was found that the optimum initial column temperature is dependent on the solvent employed. The peak areas and heights of the PAHs are enhanced when the initial column temperature is 10-20 c above the boiling point of the solvent using DB5 column, and the same or 10 C above the boiling point of the solvent using DB1 column. Comparing the peak signals of the PAHs using the alcohols, p-xylene, n-octane, and nonane as injection solvents, hexanol gave the greatest peak areas and heights of the PAHs particularly the late-eluted peaks. The detection limits were at low pg levels, ranging from 6.0 pg for fluorene t9 83.6 pg for benzo(a)pyrene. The effect of the initial column temperature on the peak shape and the separation efficiency of the PARs was also studied using DB1 and DB5 columns. Fronting or splitting of the peaks was obseIVed at very low initial column temperature. When high initial column temperature was used, tailing of the peaks appeared. Great difference between DB! and.DB5 columns in the range of the initial column temperature in which symmetrical.peaks of PAHs can be obtained is observed. Wider ranges were shown using DB5 column. Resolution of the closely-eluted PAHs was also affected by the initial column temperature depending on the stationary phase employed. In the case of DB5, only the earlyeluted PAHs were affected; whereas, with DB1, all PAHs were affected. An analytical procedure utilizing solid phase extraction with bonded phase silica (C8) cartridges combined with GC/MS was developed to analyze PAHs in water as an alternative method to those based on the extraction with organic solvent. This simple procedure involved passing a 50 ml of spiked water sample through C8 bonded phase silica cartridges at 10 ml/min, dried by passing a gentle flow of nitrogen at 20 ml/min for 30 sec, and eluting the trapped PAHs with 500 Jll of p-xylene at 0.3 ml/min. The recoveries of PAHs were greater than 80%, with less than 10% relative standard deviations of nine determinations. No major contaminants were present that could interfere with the recognition of PAHs. It was also found that these bonded phase silica cartridges can be re-used for the extraction of PAHs from water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work includes two major parts. The first part of the work concentrated on the studies of the application of the highperfonnance liquid chromatography-particle beam interface-mass spectrometry system of some pesticides. Factors that have effects on the detection sensitivity were studied. The linearity ranges and detection limits of ten pesticides are also given in this work. The second part of the work concentrated on the studies of the reduction phenomena of nitro compounds in the HPLC-PB-MS system. Direct probe mass spectrometry and gas chromatography-mass spectrometry techniques were also used in the work. Factors that have effects on the reduction of the nitro compounds were studied, and the possible explanation is proposed. The final part of this work included the studies of reduction behavior of some other compounds in the HPLC-PB-MS system, included in them are: quinones, sulfoxides, and sulfones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study was undertaken' to determine the applicability of gas liquid chromatography to the simultaneous analysis of sugars and sugar phosphates from biological samples. A new method of silylation involving dimethylsulfoxide, hexamethyldisilazane, trimethylchlorosilane and cyclohexane (1:0.2:0.1:1) which rapidly silylated sugars and sugar phosphates was developed. Subsequent chromatography on a 5% SE-52 column gave good resolution of the sugar and sugar phosphate samples. Sugar phosphates decomposed during chromatography and were lost at the 7 x 10-3 ~mole level. Acidic ethanol extraction of yeast samples revealed background contamination from the yeast sample, the culture medium and the silylation reagents which would further limit the level of detection obtainable with the glc for sugars in biological samples to the 3 x 10-4 ~mole level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combined gas chromatography and mass spectrometry has been used to identify unknown residues in soils (especially pesticides). The effect of U.V. light on DDT and linuron and quantitative estimation of elemental sulfur in different soils has also been carried out.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Factors involved in the determination of PAHs (16 priority PAHs as an example) and PCBs (10 PCB congeners, representing 10 isomeric groups) by capillary gas chromatography coupled with mass spectrometry (GC/MS, for PAHs) and electron capture detection (GC/ECD , for PCBs) were studied, with emphasis on the effect of solvent. Having various volatilities and different polarities, solvent studied included dichloromethane, acetonitrile, hexan e, cyclohexane, isooctane, octane, nonane, dodecane, benzene, toluene, p-xylene, o-xylene, and mesitylene. Temperatures of the capillary column, the injection port, the GC/MS interface, the flow rates of carrier gas and make-up gas, and the injection volume were optimized by one factor at a time method or simplex optimization method. Under the optimized conditions, both peak height and peak area of 16 PAHs, especially the late-eluting PAHs, were significantly enhanced (1 to 500 times) by using relatively higher boiling point solvents such as p-xylene and nonane, compared with commonly used solvents like benzene and isooctane. With the improved sensitivity, detection limits of between 4.4 pg for naphthalene and 30.8 pg for benzo[g,h,i]perylene were obtained when p-xylene was used as an injection solvent. Effect of solvent on peak shape and peak intensity were found to be greatly dependent on temperature parameters, especially the initial temperature of the capillary column. The relationship between initial temperature and shape of peaks from 16 PAHs and 10 PCBs were studied and compared when toluene, p-xylene, isooctane, and nonane were used as injection solvents. If a too low initial temperature was used, fronting or split of peaks was observed. On the other hand, peak tailing occurred at a too high initial column temperature. The optimum initial temperature, at which both peak fronting and tailing were avoided and symmetrical peaks were obtained, depended on both solvents and the stationary phase of the column used. On a methyl silicone column, the alkane solvents provided wider optimum ranges of initial temperature than aromatic solvents did, for achieving well-shaped symmetrical GC peaks. On a 5% diphenyl: 1% vinyl: 94% dimethyl polysiloxane column, when the aromatic solvents were used, the optimum initial temperature ranges for solutes to form symmetrical peaks were improved to a similar degree as those when the alkanes were used as injection solvents. A mechanism, based on the properties of and possible interactions among the analyte, the injection solvent, and the stationary phase of the capillary column, was proposed to explain these observations. The effect of initial temperature on peak height and peak area of the 16 PAHs and the 10 PCBs was also studied. The optimum initial temperature was found to be dependent on the physical properties of the solvent used and the amount of the solvent injected. Generally, from the boiling point of the solvent to 10 0C above its boiling point was an optimum range of initial temperature at which cthe highest peak height and peak area were obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Part I - Fluorinated Compounds A method has been developed for the extraction, concentration, and determination of two unique fluorinated compounds from the sediments of Lake Ontario. These compounds originated from a common industrial landfill, and have been carried to Lake Ontario by the Niagara River. Sediment samples from the Mississauga basin of Lake Ontario have been evaluated for these compounds and a depositional trend was established. The sediments were extracted by accelerated solvent extraction (ASE) and then underwent clean-up, fractionation, solvent exchange, and were concentrated by reduction under nitrogen gas. The concentrated extracts were analyzed by gas chromatography - electron capture negative ionization - mass spectrometry. The depositional profile determined here is reflective of the operation of the landfill and shows that these compounds are still found at concentrations well above background levels. These increased levels have been attributed to physical disturbances of previously deposited contaminated sediments, and probable continued leaching from the dumpsite. Part II - Polycyclic Aromatic Hydrocarbons Gas chromatography/mass spectrometry is the most common method for the determination of polycyclic aromatic hydrocarbons (PAHs) from various matrices. Mass discrimination of high-boiling compounds in gas chromatographic methods is well known. The use of high-boiling injection solvents shows substantial increase in the response of late-eluting peaks. These solvents have an increased efficiently in the transfer of solutes from the injector to the analytical column. The effect of I-butanol, I-pentanol, cyclopentanol, I-hexanol, toluene and n-octane, as injection solvents, was studied. Higher-boiling solvents yield increased response for all PAHs. I -Hexanol is the best solvent, in terms of P AH response, but in this solvent P AHs were more susceptible to chromatographic problems such as peak splitting and tailing. Toluene was found to be the most forgiving solvent in terms of peak symmetry and response. It offered the smallest discrepancies in response, and symmetry over a wide range of initial column temperatures.