970 resultados para SAMPLE PREPARATION METHOD


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The deep-sea environment is difficult to sample, and often only small quantities of samples can be obtained when using less destructive methods than dredging. When working with marine animals that are difficult to sample and with limited quantities of tissue to extract lipids, it is essential to ensure that the used method extracts the maximum possible quantity of lipids. This study evaluates the efficiency of introducing modifications to the method originally described by Bligh & Dyer (1959). This lipid extraction method is broadly used with modifications, although these usually lack proper description and evaluation of increment in lipids. In this study we consider the improvement in terms of amount of lipids extracted by changing the method. Lipid content was determined by gravimetric measurements in eight invertebrates from the deep-sea, including deep-sea hydrothermal vents animals, using three different approaches. Results show increases of 14% to 30% in lipid contents obtained from hydrothermal vent invertebrate tissues and whole animals by placing the samples in methanol for 24 hours before applying the Bligh & Dyer mixture. Efficiency of the extractions using frozen and freeze-dried samples was also compared. For large sponges, the use of lyophilized materials resulted in increases of 3 to 7 times more lipids extracted when compared with extractions using frozen samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A produção de biodiesel como combustível para motores diesel, aumentou fortemente nos últimos anos e espera-se que cresça mais e mais num futuro próximo. O aumento do consumo de biodiesel exige processos de produção optimizados que permitam grandes capacidades de produção, operações simplificadas, rendimentos altos, bem como a utilização de matérias-primas mais económicas. Por isso, o desenvolvimento de processos de produção de baixo custo exige a especificação de catalisadores heterogéneos eficientes na promoção da reacção de transesterificação, permitindo a imediata separação da glicerina pura, não necessitando de uma purificação dispendiosa deste subproduto. Os xerogéis de carbono surgem então como materiais promissores para aplicação como catalisadores heterogéneos para a produção de biodiesel, devido às suas excelentes propriedades ao nível da sua textura e superfície química. Neste trabalho o principal objectivo foi a preparação de um xerogel de carbono, com o intuito de posteriormente ser aplicado na produção de biodiesel por catálise heterogénea. Amostras de xerogel de carbono foram preparadas pelo método sol-gel e oxidadas em fase líquida sendo posteriormente caracterizados os seus grupos funcionais e a sua área específica. Os resultados obtidos mostram que é possivel obter um xerogel de carbono com área superficial alta, tendo sido atingido um valor máximo para a amostra número dois (803 m2/g). Os resultados atingidos ao nível da preparação do catalisador permitem concluir que as condições de operação influenciam a estrutura final do xerogel de carbono. Quanto à caracterização da química superficial do xerogel, foi possível verificar que a diferença do número de acidez entre as amostras oxidadas e não oxidadas do mesmo lote é alta, o que permite afirmar que a oxidação do material de carbono incrementa a concentração de grupos oxigénio à superfície do xerogel. O valor máximo para o número de acidez foi obtido com a amostra número três (Amostra oxidada - 916 μmol/g, Amostra não oxidada - 207 μmol/g). Apesar de terem sido realizados ensaios para a produção de biodiesel os resultados obtidos foram nulos. A escolha das condições de reacção para a catálise heterogénea com este tipo de material poderá não ter sido a mais indicada, assim como a quantidade e o tipo de grupos funcionais introduzidos no catalisador não terem acidez suficiente para permitir uma catálise efectiva.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

QuEChERS method was evaluated for extraction of 16 PAHs from fish samples. For a selective measurement of the compounds, extracts were analysed by LC with fluorescence detection. The overall analytical procedure was validated by systematic recovery experiments at three levels and by using the standard reference material SRM 2977 (mussel tissue). The targeted contaminants, except naphthalene and acenaphthene, were successfully extracted from SRM 2977 with recoveries ranging from 63.5–110.0% with variation coefficients not exceeding 8%. The optimum QuEChERS conditions were the following: 5 g of homogenised fish sample, 10 mL of ACN, agitation performed by vortex during 3 min. Quantification limits ranging from 0.12– 1.90 ng/g wet weight (0.30–4.70 µg/L) were obtained. The optimized methodology was applied to assess the safety concerning PAHs contents of horse mackerel (Trachurus trachurus), chub mackerel (Scomber japonicus), sardine (Sardina pilchardus) and farmed seabass (Dicentrarchus labrax). Although benzo(a)pyrene, the marker used for evaluating the carcinogenic risk of PAHs in food, was not detected in the analysed samples (89 individuals corresponding to 27 homogenized samples), the overall mean concentration ranged from 2.52 l 1.20 ng/g in horse mackerel to 14.6 ± 2.8 ng/ g in farmed seabass. Significant differences were found between the mean PAHs concentrations of the four groups.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new procedure for determining eleven organochlorine pesticides in soils using microwave-assisted extraction (MAE) and headspace solid phase microextraction (HS-SPME) is described. The studied pesticides consisted of mirex, α- and γ-chlordane, p,p’-DDT, heptachlor, heptachlor epoxide isomer A, γ-hexachlorocyclohexane, dieldrin, endrin, aldrine and hexachlorobenzene. The HS-SPME was optimized for the most important parameters such as extraction time, sample volume and temperature. The present analytical procedure requires a reduced volume of organic solvents and avoids the need for extract clean-up steps. For optimized conditions the limits of detection for the method ranged from 0.02 to 3.6 ng/g, intermediate precision ranged from 14 to 36% (as CV%), and the recovery from 8 up to 51%. The proposed methodology can be used in the rapid screening of soil for the presence of the selected pesticides, and was applied to landfill soil samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A SPME-GC-MS/MS method for the determination of eight organophosphorus pesticides (azinphos-methyl, chlorpyriphos, chlorpyriphos-methyl, diazinon, fenitrothion, fenthion, malathion, and methidathion) in still and fortified wine was developed. The extraction procedure is simple, solvent free, and without any sample pretreatment. Limits of detection (LOD) and quantitation (LOQ) values in the range 0.1–14.3 lg/L and 0.2–43.3 lg/L, respectively, were obtained. The LOQ values are below the maximum residue levels (MRLs) established by European Regulation for grapes, with the exception of methidathion. Coefficients of correlation (R2) higher than 0.99 were obtained for the majority of the pesticides, in all different wines analyzed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aflowinjection squarewave cathodic stripping voltammetric method has been developed for the determination of sertraline in a pharmaceutical preparation. The method shows linearity between peak current intensity and sertraline concentration for the interval between 0.20×10−6 and 1.20×10−6 mol L−1. Limits of detection and quantification were found to be 1.5×10−7 and 5.0×10−7 mol L−1, respectively. Up to 70 samples per hour can be analysed with a good precision (R.S.D. = 2.5%). The proposed method was successfully applied to the determination of sertraline in a commercial product. In the voltammetric determination of sertraline in flow, a high sample rate is obtained at reduced costs, opening the possibility to compete with the chromatographic methods generally used for this analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Resumo I (Prática Pedagógica) - Nesta seção do relatório de estágio pretende-se caraterizar e apresentar todos os elementos referentes à prática pedagógica, que fizeram parte do estágio do ensino especializado da música, realizado na Escola de Música do Orfeão de Leiria no ano letivo de 2013/2014. De uma forma geral, o relatório de estágio pretende colocar em evidência aspetos pedagógicos como metodologias de ensino, questões motivacionais, estilos de aprendizagem, entre outros. Durante um ano letivo completo foram analisados, com especial atenção, três alunos que foram envolvidos no estágio, construindo e modelando os seus processos de aprendizagem. Para cada um deles foi realizado, ao longo do ano letivo, 30 planos de aula, uma planificação anual e três gravações vídeo/áudio em contexto de aula. Não foi uma tarefa nada fácil de realizar, mas que trouxe inúmeros conhecimentos não só de caráter pedagógico mas também de caráter pessoal. A parte inicial desta seção será dedicada à descrição e caraterização da escola onde foi realizado o estágio, a Escola de Música do Orfeão de Leiria/Conservatório de Artes. Será feita uma pequena abordagem histórica da instituição, bem como do seu projeto educativo, dacomunidade escolar, do seu contexto sociocultural e da classe de saxofone. Será apresentada também uma caraterização dos alunos, segundo vários parâmetros. Posteriormente, serão descritas algumas das práticas educativas desenvolvidas, com os alunos, em contexto de estágio. Para tal, serão utilizados como instrumentos, não só a experiência ativa do docente/estagiário, mas também todas as gravações, planos de aulas e planificações anuais, realizados em contexto de estágio do ensino especializado. Por fim, será realizada uma reflexão crítica do desempenho como docente de saxofone no âmbito do estágio e uma conclusão de toda a seção da prática pedagógica.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Amulti-residue methodology based on a solid phase extraction followed by gas chromatography–tandem mass spectrometry was developed for trace analysis of 32 compounds in water matrices, including estrogens and several pesticides from different chemical families, some of them with endocrine disrupting properties. Matrix standard calibration solutions were prepared by adding known amounts of the analytes to a residue-free sample to compensate matrix-induced chromatographic response enhancement observed for certain pesticides. Validation was done mainly according to the International Conference on Harmonisation recommendations, as well as some European and American validation guidelines with specifications for pesticides analysis and/or GC–MS methodology. As the assumption of homoscedasticity was not met for analytical data, weighted least squares linear regression procedure was applied as a simple and effective way to counteract the greater influence of the greater concentrations on the fitted regression line, improving accuracy at the lower end of the calibration curve. The method was considered validated for 31 compounds after consistent evaluation of the key analytical parameters: specificity, linearity, limit of detection and quantification, range, precision, accuracy, extraction efficiency, stability and robustness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Paracetamol is among the most worldwide consumed pharmaceuticals. Although its occurrence in the environment is well documented, data about the presence of its metabolites and transformation products is very scarce. The present work describes the development of an analytical method for the simultaneous determination of paracetamol, its principal metabolite (paracetamol-glucuronide) and its main transformation product (p-aminophenol) based on solid phase extraction (SPE) and high performance liquid chromatography coupled to diode array detection (HPLC-DAD). The method was applied to analysis of river waters, showing to be suitable to be used in routine analysis. Different SPE sorbents were compared and the use of two Oasis WAX cartridges in tandem proved to be the most adequate approach for sample clean up and pre-concentration. Under optimized conditions, limits of detection in the range 40–67 ng/L were obtained, as well as mean recoveries between 60 and 110% with relative standard deviations (RSD) below 6%. Finally, the developed SPE-HPLC/DAD method was successfully applied to the analysis of the selected compounds in samples from seven rivers located in the north of Portugal. Nevertheless all the compounds were detected, it was the first time that paracetamol-glucuronide was found in river water at concentrations up to 3.57 μg/L.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The National Cancer Institute (NCI) method allows the distributions of usual intake of nutrients and foods to be estimated. This method can be used in complex surveys. However, the user must perform additional calculations, such as balanced repeated replication (BRR), in order to obtain standard errors and confidence intervals for the percentiles and mean from the distribution of usual intake. The objective is to highlight adaptations of the NCI method using data from the National Dietary Survey. The application of the NCI method was exemplified analyzing the total energy (kcal) and fruit (g) intake, comparing estimations of mean and standard deviation that were based on the complex design of the Brazilian survey with those assuming simple random sample. Although means point estimates were similar, estimates of standard error using the complex design increased by up to 60% compared to simple random sample. Thus, for valid estimates of food and energy intake for the population, all of the sampling characteristics of the surveys should be taken into account because when these characteristics are neglected, statistical analysis may produce underestimated standard errors that would compromise the results and the conclusions of the survey.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Interest in polyethylene and polypropylene bonding has increased in the last years. However, adhesive joints with adherends which are of low surface energy and which are chemically inert present several difficulties. Generally, their high degree of chemical resistance to solvents and dissimilar solubility parameters limit the usefulness of solvent bonding as a viable assembly technique. One successful approach to adhesive bonding of these materials involves proper selection of surface pre-treatment prior to bonding. With the correct pre-treatment it is possible to glue these materials with one or more of several adhesives required by the applications involved. A second approach is the use of adhesives without surface pre-treatment, such as hot melts, high tack pressure-sensitive adhesives, solvent-based specialty adhesives and, more recently, structural acrylic adhesives as such 3M DP-8005® and Loctite 3030®. In this paper, the shear strengths of two acrylic adhesives were evaluated using the lap shear test method ASTM D3163 and the block shear test method ASTM D4501. Two different industrial polyolefins (polyethylene and polypropylene) were used for adherends. However, the focus of this study was to measure the shear strength of polyethylene joints with acrylic adhesives. The effect of abrasion was also studied. Some test specimens were manually abraded using 180 and 320 grade abrasive paper. An additional goal of this work was to examine the effect of temperature and moisture on mechanical strength of adhesive joints.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT OBJECTIVE To describe the prevalence of asthma and physician-diagnosed asthma in Brazilian adolescents. METHODS Cross-sectional, national, school-based study with adolescents from 12 to 17 years old, participants in the Study of Cardiovascular Risks in Adolescents (ERICA). The study stratified the sample by region and grouped according to schools and classes with representativeness to the set of cities with more than 100,000 inhabitants of the Country, macro-regions, capitals, and Federal District. A questionnaire collected data through a self-filled in method. We calculated the prevalences and their confidence intervals of 95% (95%CI) according to sex, age group, type of school and skin color. RESULTS Between 2013 and 2014, 74,589 adolescents were evaluated, 55.3% of the female sex. The total prevalence of active asthma was of 13.1% (95%CI 12.1-13.9), being higher in girls (14.8%; 95%CI 13.7-16.0) when compared to boys (11.2%; 95%CI 10.3-12.2) in all geographical strata examined. It was also higher between students of private schools (15.9%; 95%CI 14.2-17.7) when compared to public ones (12.4%; 95%CI 11.4-13.4). It was higher in the Southeast region (14.5%; 95%CI 12.9-16.1), and in the city of Sao Paulo (16.7%; 95%CI 14.7-18.7). The lowest prevalence was observed in North region (9.7%; 95%CI 9.7-10.5), and in Teresina (6.3%; 95%CI 4.9-7.7). The prevalence of physician-diagnosed asthma was of 8.7% (95%CI 8.2-9.1); higher in the North region (13.5%; 95%CI 12.7-14.2), and in Porto Alegre (19.8%; 95%CI 17.5-22.3). It was lower in the Midwest (6.9%; 95%CI 6.0-7.8), and in Cuiaba (4.8%; 95%CI 3.8-5.9). We found no significant difference in the expression of this rate between the sexes, as well as in other variables evaluated by the study. CONCLUSIONS The prevalence of asthma in Brazilian adolescents is high. Rates of active asthma and physician-diagnosed asthma vary widely in different regions and capitals evaluated by the ERICA. These results may assist in the preparation of preventive programs and policies on health and a better understanding of the factors associated with asthma in this age group.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We propose a blind method to detect interference in GNSS signals whereby the algorithms do not require knowledge of the interference or channel noise features. A sample covariance matrix is constructed from the received signal and its eigenvalues are computed. The generalized likelihood ratio test (GLRT) and the condition number test (CNT) are developed and compared in the detection of sinusoidal and chirp jamming signals. A computationally-efficient decision threshold was proposed for the CNT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O trabalho apresentado centra-se na determinação dos custos de construção de condutas de pequenos e médios diâmetros em Polietileno de Alta Densidade (PEAD) para saneamento básico, tendo como base a metodologia descrita no livro Custos de Construção e Exploração – Volume 9 da série Gestão de Sistemas de Saneamento Básico, de Lencastre et al. (1994). Esta metodologia descrita no livro já referenciado, nos procedimentos de gestão de obra, e para tal foram estimados custos unitários de diversos conjuntos de trabalhos. Conforme Lencastre et al (1994), “esses conjuntos são referentes a movimentos de terras, tubagens, acessórios e respetivos órgãos de manobra, pavimentações e estaleiro, estando englobado na parte do estaleiro trabalhos acessórios correspondentes à obra.” Os custos foram obtidos analisando vários orçamentos de obras de saneamento, resultantes de concursos públicos de empreitadas recentemente realizados. Com vista a tornar a utilização desta metodologia numa ferramenta eficaz, foram organizadas folhas de cálculo que possibilitam obter estimativas realistas dos custos de execução de determinada obra em fases anteriores ao desenvolvimento do projeto, designadamente numa fase de preparação do plano diretor de um sistema ou numa fase de elaboração de estudos de viabilidade económico-financeiros, isto é, mesmo antes de existir qualquer pré-dimensionamento dos elementos do sistema. Outra técnica implementada para avaliar os dados de entrada foi a “Análise Robusta de Dados”, Pestana (1992). Esta metodologia permitiu analisar os dados mais detalhadamente antes de se formularem hipóteses para desenvolverem a análise de risco. A ideia principal é o exame bastante flexível dos dados, frequentemente antes mesmo de os comparar a um modelo probabilístico. Assim, e para um largo conjunto de dados, esta técnica possibilitou analisar a disparidade dos valores encontrados para os diversos trabalhos referenciados anteriormente. Com os dados recolhidos, e após o seu tratamento, passou-se à aplicação de uma metodologia de Análise de Risco, através da Simulação de Monte Carlo. Esta análise de risco é feita com recurso a uma ferramenta informática da Palisade, o @Risk, disponível no Departamento de Engenharia Civil. Esta técnica de análise quantitativa de risco permite traduzir a incerteza dos dados de entrada, representada através de distribuições probabilísticas que o software disponibiliza. Assim, para por em prática esta metodologia, recorreu-se às folhas de cálculo que foram realizadas seguindo a abordagem proposta em Lencastre et al (1994). A elaboração e a análise dessas estimativas poderão conduzir à tomada de decisões sobre a viabilidade da ou das obras a realizar, nomeadamente no que diz respeito aos aspetos económicos, permitindo uma análise de decisão fundamentada quanto à realização dos investimentos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The most common techniques for stress analysis/strength prediction of adhesive joints involve analytical or numerical methods such as the Finite Element Method (FEM). However, the Boundary Element Method (BEM) is an alternative numerical technique that has been successfully applied for the solution of a wide variety of engineering problems. This work evaluates the applicability of the boundary elem ent code BEASY as a design tool to analyze adhesive joints. The linearity of peak shear and peel stresses with the applied displacement is studied and compared between BEASY and the analytical model of Frostig et al., considering a bonded single-lap joint under tensile loading. The BEM results are also compared with FEM in terms of stress distributions. To evaluate the mesh convergence of BEASY, the influence of the mesh refinement on peak shear and peel stress distributions is assessed. Joint stress predictions are carried out numerically in BEASY and ABAQUS®, and analytically by the models of Volkersen, Goland, and Reissner and Frostig et al. The failure loads for each model are compared with experimental results. The preparation, processing, and mesh creation times are compared for all models. BEASY results presented a good agreement with the conventional methods.