979 resultados para Repeated Load Triaxial (RLT) test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compared the indirect immunofluorescence assay (IFA) with Western blot (Wb) as a confirmatory method to detect antibodies anti retrovirus (HIV-1 and HTLV-I/II). Positive and negative HIV-1 and HTLV-I/II serum samples from different risk populations were studied. Sensitivity, specificity, positive, negative predictive and kappa index values were assayed, to assess the IFA efficiency versus Wb. The following cell lines were used as a source of viral antigens: H9 ( HTLV-III b); MT-2 and MT-4 (persistently infected with HTLV-I) and MO-T (persistently infected with HTLV-II). Sensitivity and specificity rates for HIV-1 were 96.80% and 98.60% respectively, while predictive positive and negative values were 99.50% and 92.00% respectively. No differences were found in HIV IFA performance between the various populations studied. As for IFA HTLV system, the sensitivity and specificity values were 97.91% and 100% respectively with positive and negative predictive values of 100% and 97.92%. Moreover, the sensitivity of the IFA for HTLV-I/II proved to be higher when the samples were tested simultaneously against both antigens (HTLV-I-MT-2 and HTLV-II-MO-T). The overall IFA efficiency for HIV-1 and HTLV-I/II-MT-2 antibody detection probed to be very satisfactory with an excellent correlation with Wb (Kappa indexes 0.93 and 0.98 respectively). These results confirmed that the IFA is a sensitive and specific alternative method for the confirmatory diagnosis of HIV-1 and HTLV-I/II infection in populations at different levels of risk to acquire the infection and suggest that IFA could be included in the serologic diagnostic algorithm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A aplicação do material compósito é neste momento bastante vasta, graças à combinação das suas características específicas, tais como, maior resistência específica e módulos específicos e melhor resistência à fadiga, quando comparados com os metais convencionais. Tais características, quando requeridas, tornam este material ideal para aplicações estruturais. Esta caminhada de sucesso iniciou desde muito cedo, quando o material compósito já era utilizado para fabrico de armas pelos mongóis e na construção civil pelos hebreus e egípcios, contudo, só a partir dos meados do século XX é que despertou interesses para aplicações mais modernas. Atualmente os materiais compósitos são utilizados em equipamentos domésticos, componentes elétricos e eletrónicos, passando por materiais desportivos, pela indústria automóvel e construção civil, até indústrias de grande exigência e visibilidade tecnológica como a aeronáutica, espacial e de defesa. Apesar das boas características apresentadas pelos materiais compósitos, no entanto, estes materiais têm tendência a perderem as suas propriedades quando submetidas a algumas operações de acabamento como a furação. A furação surge da necessidade de ligação de peças de um mesmo mecanismo. Os furos obtidos por este processo devem ser precisos e sem danos para garantir ligações de alta resistência e também precisas. A furação nos materiais compósitos é bastante complexa devido à sua heterogeneidade, anisotropia, sensibilidade ao calor e pelo facto de os reforços serem extremamente abrasivos. A operação de furação pode causar grandes danos na peça, como a delaminação a entrada, defeitos de circularidade do furo, danos de origem térmica e a delaminação à saída que se apresenta como o mais frequente e indesejável. Com base nesses pressupostos é que este trabalho foi desenvolvido de forma a tentar obter processos simples para determinação e previsão de danos em polímeros reforçados com fibras (de carbono neste caso) de forma a precavê-los. De forma a conseguir estes objetivos, foram realizados ensaios de início de delaminação segundo a proposta de Lachaud et al. e ensaios de pin-bearing segundo a proposta de Khashaba et al. Foram também examinadas extensões de danos de acordo com o modelo de Fator de delaminação ajustado apresentado por Davim et al. A partir dos ensaios, de pin-bearing, realizados foram analisadas influências do material e geometria da broca, do avanço utilizado na furação e de diferentes orientações de empilhamentos de placas na delaminação de laminados compósitos e ainda a influências dessas variáveis na força de rutura por pin-bearing. As principais conclusões tiradas daqui são que a delaminação aumenta com o aumento do avanço, o que já era esperado, as brocas em carboneto de tungsténio são as mais recomendas para a furação do material em causa e que a delaminação é superior para a placa cross-ply quando comparada com placas unidirecionais. Para a situação de ensaios de início de delaminação foram analisadas as influências da variação da espessura não cortada por baixo da broca/punção, de diferentes geometrias de brocas, da alteração de velocidade de ensaio e diferentes orientações de empilhamentos de placas na força de início de delaminação. Deste ensaio as principais conclusões são que a força de início de delaminação aumenta com o aumenta da espessura não cortada e a influência da velocidade de ensaio altera com a variação das orientações de empilhamento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study ELISA was standardized for the diagnosis of swine cysticercosis based on necropsy parameters and confirmed positive and negative control sera. Serum samples from pigs with other infections were also assayed to determine possible cross-reactions. Four antigens were assayed: from Taenia crassiceps vesicular fluid (VF-Tcra) and crude larvae extract (T-Tcra), and from Taenia solium extracts of scolex (S-Ts) and of larvae (T-Ts). A checkerboard evaluation of antigen, serum and conjugate dilutions, as well as the use of Tween-20 and skim cow milk in wash and blocking solution had a marked effect on improving ELISA performance. All the antigens showed a good performance, but VF-Tcra was the best, with 96.0% and 80.0% sensitivities for cut-offs respectively at 2sd and 3sd, and corresponding specificities of 97.5% and 100.0%. Cross-reactivity was observed only with hydatidosis and ascaridiosis. In view of the high performance observed, the ELISA test should be recommended for the diagnosis of cysticercosis in suspected swine in slaughterhouses and for the screening of cysticercosis in swine production. These results will support integrated measures of cysticercosis control throughout the chain of swine production, effectively contributing to public health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An epizootic outbreak of rabies occurred in 1995 in Ribeirão Preto, SP, with 58 cases of animal rabies (54 dogs, 3 cats and 1 bat) confirmed by the Pasteur Institute of São Paulo, and one human death. The need to provide care to a large number of people for the application of equine rabies immune globulin (ERIG) prevented the execution of the skin sensitivity test (SST) and often also the execution of desensitization, procedures routinely used up to that time at the Emergency Unit of the University Hospital of the Faculty of Medicine of Ribeirão Preto, University of São Paulo (EU-UHFMRP-USP), a reference hospital for the application of heterologous sera. In view of our positive experience of several years with the abolition of SST and of the use of premedication before the application of antivenom sera, we used a similar schedule for ERIG application. Of the 1489 victims of animal bites, 1054 (71%) received ERIG; no patient was submitted to SST and all received intravenously anti-histamines (anti-H1 + anti-H2) and corticosteroids before the procedure. The patients were kept under observation for 60 to 180 minutes and no adverse reaction was observed. On the basis of these results, since December 1995 ERIG application has been decentralized in Ribeirão Preto and has become the responsibility of the Emergency Unit of the University Hospital and the Central Basic Health Unit, where the same routine is used. Since then, 4216 patients have received ERIG (1818 at the Basic Health Unit and 2398 at the EU-UHFMRP), with no problems. The ideal would be the routine use of human rabies immune globulin (HRIG) in public health programs, but this is problematic, because of their high cost. However, while this does not occur, the use of SST is no longer justified at the time of application of ERIG, in view of the clinical evidence of low predictive value and low sensitivity of SST involving the application of heterologous sera. It is very important to point out that a negative SST result may lead the health team to a feeling of false safety that no adverse reaction will occur, but this is not true for the anaphylactoid reactions. The decision to use premedication, which is based on knowledge about anaphylaxis and on the pharmacology of the medication used, is left to the judgment of health professionals, who should always be prepared for eventual untoward events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A engenharia civil, rege-se pela garantia de segurança e de funcionalidade das obras que projeta e executa. Para cumprir tais requisitos, é necessário durante a sua vida útil, no final da construção, reforço ou reabilitação, proceder à avaliação da conformidade entre o comportamento real da estrutura e os pressupostos subjacentes ao projeto. Esta dissertação tem como objetivo a compreensão e análise do comportamento estrutural da Ponte sobre o Rio Sorraia, através da realização de ensaios de carga apoiados pela conceção de um modelo numérico devidamente calibrado, capaz de simular a resposta da estrutura, o mais próximo possível do observável na realidade. Para alcançar o objetivo pré definido elencam-se as metodologias relevantes, descrevem-se os tipos de ensaios de carga realizados em pontes/viadutos e faz-se referência aos aparelhos de medição que estão na base da instrumentação aplicada em obras. Esta introdução foca-se ainda na modelação numérica, permitindo o conhecimento básico necessário para a criação e atualização de modelos numéricos de pontes. Relativamente ao caso de estudo expõe-se a realização do ensaio de carga, descrevendo todo o processo, bem como os resultados obtidos ao nível das grandezas de medição estudadas. Aqui é concebido um modelo numérico base da ponte, alvo de discussão ao nível do comportamento estrutural, baseada na validação dos resultados obtidos por via experimental, através da comparação com os obtidos por via numérica. Por fim, o estudo e seleção de diversos parâmetros da modelação, facultando a calibração do modelo numérico da ponte. Os resultados obtidos neste modelo comprovam o seu elevado potencial, no apoio à observação e compreensão do comportamento de estruturas através da realização de ensaios de carga. O sucesso da realização de uma análise do comportamento de estruturas, através de ensaios de carga, depende assim fundamentalmente, da correta execução do ensaio, da correta conceção e atualização do modelo numérico e da interligação entre os resultados experimentais e numéricos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In occupational accidents involving health professionals handling potentially contaminated material, the decision to start or to continue prophylactic medication against infection by Human Immunodeficiency Virus (HIV) has been based on the ELISA test applied to a blood sample from the source patient. In order to rationalize the prophylactic use of antiretroviral agents, a rapid serologic diagnostic test of HIV infection was tested by the enzymatic immunoabsorption method (SUDS HIV 1+2, MUREX®) and compared to conventional ELISA (Abbott HIV-1/ HIV-2 3rd Generation plus EIA®). A total of 592 cases of occupational accidents were recorded at the University Hospital of Ribeirão Preto from July 1998 to April 1999. Of these, 109 were simultaneously evaluated by the rapid test and by ELISA HIV. The rapid test was positive in three cases and was confirmed by ELISA and in one the result was inconclusive and later found to be negative by ELISA. In the 106 accidents in which the rapid test was negative no prophylactic medication was instituted, with an estimated reduction in costs of US$ 2,889.35. In addition to this advantage, the good correlation of the rapid test with ELISA, the shorter duration of stress and the absence of exposure of the health worker to the adverse effects of antiretroviral agents suggest the adoption of this test in Programs of Attention to Accidents with Potentially Contaminated Material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simple and rapid latex-based diagnostic tests have been used for detecting specific antigens or antibodies in several diseases. In this article, we present the preliminary results obtained with a latex agglutination test (LAT) for diagnosing neurocysticercosis by detection of antibodies in CSF. A total of 43 CSF samples were assayed by the LAT: 19 CSF samples from patients with neurocysticercosis and 24 CSF samples from patients with other neurologic disorders (neurosyphilis, n = 8; neurotoxoplasmosis, n = 3; viral meningitis, n = 4, chronic headache, n = 9). The LAT exhibited 89.5% sensitivity and 75% specificity. The use of LAT seems to be an additional approach for the screening of neurocysticercosis with advantage of simplicity and rapidity. Further studies could be performed using purified antigens and serum samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analysis of 58 patients with chronic hepatitis C without cirrhosis and treated with interferon-alpha demonstrated that hepatitis C viral (HCV) load does not correlate with the histological evolution of the disease (p = 0.6559 for architectural alterations and p = 0.6271 for the histological activity index). Therefore, the use of viral RNA quantification as an evolutive predictor or determinant of the severity of hepatitis C is incorrect and of relative value. A review of the literature provided fundamental and interdependent HCV (genotype, heterogeneity and mutants, specific proteins), host (sex, age, weight, etc) and treatment variables (dosage, time of treatment, type of interferon) within the broader context of viral kinetics, interferon-mediated immunological response (in addition to natural immunity against HCV) and the role of interferon as a modulator of fibrogenesis. Therefore, viral load implies much more than numbers and the correct interpretation of these data should consider a broader context depending on multiple factors that are more complex than the simple value obtained upon quantification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study was carried out to evaluate the Malar-CheckTM Pf test, an immunochromatographic assay that detects Plasmodium falciparum Histidine Rich Protein II, does not require equipment, and is easy and rapid to perform. In dilution assays performed to test sensitivity against known parasite density, Malar-CheckTMwere compared with thick blood smear (TBS), the gold standard for diagnosis. Palo Alto isolate or P. falciparum blood from patients with different parasitemias was used. The average cut-off points for each technique in three independent experiments were 12 and 71 parasites/mm³ (TBS and Malar-CheckTM, respectively). In the field assays, samples were collected from patients with fever who visited endemic regions. Compared to TBS, Malar-CheckTMyielded true-positive results in 38 patients, false-positive results in 3, true-negative results in 23, and false-negative result in 1. Malar-CheckTMperformed with samples from falciparum-infected patients after treatment showed persistence of antigen up to 30 days. Malar-CheckTM should aid the diagnosis of P. falciparum in remote areas and improve routine diagnosis even when microscopy is available. Previous P. falciparum infection, which can determine a false-positive test in cured individuals, should be considered. The prompt results obtained with the Malar-CheckTM for early diagnosis could avoid disease evolution to severe cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ergonomic interventions such as increased scheduled breaks or job rotation have been proposed to reduce upper limb muscle fatigue in repetitive low-load work. This review was performed to summarize and analyze the studies investigating the effect of job rotation and work-rest schemes, as well as, work pace, cycle time and duty cycle, on upper limb muscle fatigue. The effects of these work organization factors on subjective fatigue or discomfort were also analyzed. This review was based on relevant articles published in PubMed, Scopus and Web of Science. The studies included in this review were performed in humans and assessed muscle fatigue in upper limbs. 14 articles were included in the systematic review. Few studies were performed in a real work environment and the most common methods used to assess muscle fatigue were surface electromyography (EMG). No consistent results were found related to the effects of job rotation on muscle activity and subjective measurements of fatigue. Rest breaks had some positive effects, particularly in perceived discomfort. The increase in work pace reveals a higher muscular load in specific muscles. The duration of experiments and characteristics of participants appear to be the factors that most have influenced the results. Future research should be focused on the improvement of the experimental protocols and instrumentation, in order to the outcomes represent adequately the actual working conditions. Relevance to industry: Introducing more physical workload variation in low-load repetitive work is considered an effective ergonomic intervention against muscle fatigue and musculoskeletal disorders in industry. Results will be useful to identify the need of future research, which will eventually lead to the adoption of best industrial work practices according to the workers capabilities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the whole blood immunochromatographic card test (ICT card test) in a survey performed in Northeastern Brazil. 625 people were examined by the thick blood film (TBF) and ICT card test. Residents of a non-endemic area were also tested by the whole blood card test and Og4C3. The sensitivity of the ICT card test was 94.7% overall, but lower in females than males, based on the reasonable assumption that TBF is 100% specific. However, since TBF and other methods have unknown sensitivity, the true specificity of the card test is unknown. Nevertheless, it is possible to estimate upper and lower limits for the specificity, and relate it to the prevalence of the disease. In the endemic area, the possible range of the specificity was from 72.4% to 100%. 29.6% of the card tests performed in the non-endemic area exhibited faint lines that were interpreted as positives. Characteristics of the method including high sensitivity, promptness and simplicity justify its use for screening of filariasis. However, detailed information about the correct interpretation in case of extremely faint lines is essential. Further studies designed to consider problems arising from imperfect standards are necessary, as is a sounder diagnostic definition for the card test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The wide use of antibiotics in aquaculture has led to the emergence of resistant microbial species. It should be avoided/minimized by controlling the amount of drug employed in fish farming. For this purpose, the present work proposes test-strip papers aiming at the detection/semi-quantitative determination of organic drugs by visual comparison of color changes, in a similar analytical procedure to that of pH monitoring by universal pH paper. This is done by establishing suitable chemical changes upon cellulose, attributing the paper the ability to react with the organic drug and to produce a color change. Quantitative data is also enabled by taking a picture and applying a suitable mathematical treatment to the color coordinates given by the HSL system used by windows. As proof of concept, this approach was applied to oxytetracycline (OXY), one of the antibiotics frequently used in aquaculture. A bottom-up modification of paper was established, starting by the reaction of the glucose moieties on the paper with 3-triethoxysilylpropylamine (APTES). The so-formed amine layer allowed binding to a metal ion by coordination chemistry, while the metal ion reacted after with the drug to produce a colored compound. The most suitable metals to carry out such modification were selected by bulk studies, and the several stages of the paper modification were optimized to produce an intense color change against the concentration of the drug. The paper strips were applied to the analysis of spiked environmental water, allowing a quantitative determination for OXY concentrations as low as 30 ng/mL. In general, this work provided a simple, method to screen and discriminate tetracycline drugs, in aquaculture, being a promising tool for local, quick and cheap monitoring of drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid test based on an immunochromatography assay - Determine™ Syphilis TP (Abbott Lab.) for detecting specific antibodies to Treponema pallidum was evaluated against serum samples from patients with clinical, epidemiological and serological diagnosis of syphilis, patients with sexually transmitted disease other than syphilis, and individuals with negative serology for syphilis. The Determine™ test presented the sensitivity of 93.6%, specificity of 92.5%, and positive predictive value and negative predictive value of 95.2% and 93.7%, respectively. One serum sample from patient with recent latent syphilis showed a prozone reaction. Determine™ is a rapid assay, highly specific and easy to perform. This technique obviates the need of equipment and its diagnostic features demonstrate that it may be applicable as an alternative assay for syphilis screening under some emergency conditions or for patients living in remote localities.