873 resultados para Reinforced concrete construction


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Supuestos prácticos de autoevaluación de la asignatura "Estructuras de Hormigón Armado y Pretensado".

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The mechanical behaviour of transventilated façades performed by natural stone is necessarily based on the correct execution of both anchoring elements on the stone cladding as in the ones corresponding to the enclosure support, either with brick masonry walls or reinforced concrete walls. In the case studied in the present work, the origin of the damages suffered on the façade of a building located in Alcoy has been analyzed, where the detachment of part of the outer enclosure occurred. This enclosure is a transventilated façade formed by Bateig Blue stone tiles. To this end, “in situ” tests of the anchoring systems employed have been performed, as well as laboratory tests of mechanical characterization of the material and of different types of anchor, comparing these results with those obtained in both the simplified analytical models of continuum mechanics as developed by the Finite Element Method (FEM).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study is in the frame of the cooperative line that several Spanish Universities and other foreign partners started with the Haitian government in 2010. According to our studies (Benito et al. in An evaluation of seismic hazard in La Hispaniola, after the 2010 Haiti earthquake, 33rd General Assembly of the European Seismological Commission, Moscow, Russia, 2012) and recent scientific literature, the earthquake hazard in Haiti remains high (Calais et al. in Nat Geosci 3:794–799, 2010). In view of this, we wonder whether the country is currently ready to face another earthquake. In this sense, we estimated several damage scenarios in Port-au-Prince and Cap-Haitien associated to realistic possible major earthquakes. Our findings show that almost 50 % of the building stock of both cities would result uninhabitable due to structural damage. Around 80 % of the buildings in both cities have reinforced concrete structure with concrete block infill; however, the presence of masonry buildings becomes significant (between 25 and 45 % of the reinforced concrete buildings) in rural areas and informal settlements on the outskirts, where the estimated damage is higher. The influence of the soil effect on the damage spatial distribution is evident in both cities. We have found that the percentage of uninhabitable buildings in soft soil areas may be double the percentage obtained in nearby districts located in hard soil. These results reveal that a new seismic catastrophe of similar or even greater consequences than the 2010 Haiti earthquake might happen if the earthquake resilience is not improved in the country. Nowadays, the design of prevention actions and mitigation policies is the best instrument the society has to face seismic risk. In this sense, the results of this research might contribute to define measures oriented to earthquake risk reduction in Haiti, which should be a real priority for national and international institutions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O recurso a sistemas de fachadas prefabricadas no ramo da Construção Civil tem-se revelado uma opção eficaz, apresentando-se como uma solução de vanguarda no sentido de garantir vantagens ao nível da qualidade e da produtividade. A introdução de painéis de GRC (Glassfibre Reinforced Concrete) no mercado da construção trouxe vantagens ao sector uma vez que compatibiliza as vantagens da prefabricação leve, elevados níveis de desempenho e uma grande latitude em termos de formas e acabamentos. Este compósito é formado por uma matriz de argamassa reforçada com fibra de vidro. A incorporação das fibras permite melhorar as propriedades mecânicas da argamassa, principalmente ao nível da resistência de tração e flexão, fazendo com que os elementos possam ter menores espessuras e consequentemente menor peso, comparativamente com peças de betão armado. No mercado são comercializados três tipos de painéis de GRC, os do tipo nervurado, os do tipo stud frame e os do tipo sanduiche. Estes vários tipos de painéis tem as suas particularidades e a seleção depende das exigências e das características da obra. O estudo teve como alvo diferentes formas e dimensões de painéis de fachada em GRC do tipo nervurado. No presente trabalho faz-se um estudo comparativo da aplicação de dois métodos de dimensionamento. Comparam-se os resultados obtidos pela teoria clássica da flexão (TCF) e pelo método dos elementos finitos (MEF) e confrontam-se estes valores com os resultados obtidos em ensaios. Com o estudo efetuado conclui-se pela validade e utilidade da análise através da TCF, cujos resultados se aproximam bastante da análise pelo MEF. Sugerem-se coeficientes de ajustamento no sentido de adaptar a pratica de projeto em conformidade com os resultados verificados.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

"May 1997."

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Project pre-SCHOONER.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Description based on: Volume 12, no. 1 (Jan. 1911); title from cover.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Some issues have double volume numbering: vol. 26 (1930)-v. 57 (1960) of the Proceedings appear in vol. 2 (1930)-v. 32 (1960) of the Journal of the American Concrete Institute.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Vols. for 1905-12 issued by the institute under its earlier name: National Association of Cement Users.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

"Verzeichnis von Abhandlung über Eisenbeton-Balkenbrücken in verschiedenen Fachzeitschriften," vol.1, p.185-187; "Verzeichnis von neueren Abhandlungen über Eisenbeton-Wölbbrücken in verschiedenen Fachzeitschriften," vol.2, p.195-198.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Includes: Indicateur du congres.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Shear strengthening is required when an RC beam is found deficient in shear, or when its shear capacity falls below its flexural capacity after flexural strengthening. A recent technique for the shear strengthening of RC beams is to provide additional FRP web reinforcement, commonly in the form of bonded external FRP strips/sheets. Over the last few years, several experimental studies have been conducted on this new strengthening technique, which has established its effectiveness. While experimental methods of investigation are extremely useful in obtaining information about the composite behaviour of FRP and reinforced concrete, the use of numerical models such as the one presented in this paper helps in developing a good understanding of the behaviour at lower costs. In the study presented in this paper, ANSYS finite element program is used to examine the response of beams strengthened in shear by FRPs. The FE model is calibrated against test results performed at the University of Kentucky. Once validated, the model is used to examine the influence of fibre orientation, compressive strength of concrete, area of tensile and compressive reinforcements, and amount and distance between stirrups on the strength and ductility of FRP strengthened beam.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this Thesis, details of a proposed method for the elastic-plastic failure load analysis of complete building structures are given. In order to handle the problem, a computer programme in Atlas Autocode is produced. The structures consist of a number of parallel shear walls and intermediate frames connected by floor slabs. The results of an experimental investigation are given to verify the theoretical results and to demonstrate various factors that may influence the behaviour of these structures. Large full scale practical structures are also analysed by the proposed method and suggestions are made for achieving design economy as well as for extending research in various aspects of this field. The existing programme for elastic-plastic analysis of large frames is modified to allow for the effect of composite action of structural members, i.e. reinforced concrete floor slabs and the supporting steel beams. This modified programme is used to analyse some framed type structures with composite action as well as those which incorporate plates and shear walls. The results obtained are studied to ascertain the influence of composite action and other factors on the load carrying capacity of both bare frames and complete building structures. The theoretical failure load presented in this thesis does not predict the overall failure load of the structure nor does it predict the partial failure load of the shear walls and slabs but it merely predicts the partial failure load of a single frame and assumes that the loss of stiffess of such a frame renders the overall structure unusable. For most structures the analysis proposed in this thesis is likely to break down prematurely due to the failure of the slab and shear wall system and this factor must be taken into account in any future work on such structures. The experimental work reported in this thesis is acknowledged to be unsatisfactory as a verification of the limited theory proposed. In particular perspex was not found to be a suitable material for testing at high loads, micro-concrete may be more suitable.