799 resultados para Radiography, Bitewing


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Scatter in medical imaging is typically cast off as image-related noise that detracts from meaningful diagnosis. It is therefore typically rejected or removed from medical images. However, it has been found that every material, including cancerous tissue, has a unique X-ray coherent scatter signature that can be used to identify the material or tissue. Such scatter-based tissue-identification provides the advantage of locating and identifying particular materials over conventional anatomical imaging through X-ray radiography. A coded aperture X-ray coherent scatter spectral imaging system has been developed in our group to classify different tissue types based on their unique scatter signatures. Previous experiments using our prototype have demonstrated that the depth-resolved coherent scatter spectral imaging system (CACSSI) can discriminate healthy and cancerous tissue present in the path of a non-destructive x-ray beam. A key to the successful optimization of CACSSI as a clinical imaging method is to obtain anatomically accurate phantoms of the human body. This thesis describes the development and fabrication of 3D printed anatomical scatter phantoms of the breast and lung.

The purpose of this work is to accurately model different breast geometries using a tissue equivalent phantom, and to classify these tissues in a coherent x-ray scatter imaging system. Tissue-equivalent anatomical phantoms were designed to assess the capability of the CACSSI system to classify different types of breast tissue (adipose, fibroglandular, malignant). These phantoms were 3D printed based on DICOM data obtained from CT scans of prone breasts. The phantoms were tested through comparison of measured scatter signatures with those of adipose and fibroglandular tissue from literature. Tumors in the phantom were modeled using a variety of biological tissue including actual surgically excised benign and malignant tissue specimens. Lung based phantoms have also been printed for future testing. Our imaging system has been able to define the location and composition of the various materials in the phantom. These phantoms were used to characterize the CACSSI system in terms of beam width and imaging technique. The result of this work showed accurate modeling and characterization of the phantoms through comparison of the tissue-equivalent form factors to those from literature. The physical construction of the phantoms, based on actual patient anatomy, was validated using mammography and computed tomography to visually compare the clinical images to those of actual patient anatomy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Human cadavers have long been used to teach human anatomy and are increasingly used in other disciplines. Different embalming techniques have been reported in the literature; however there is no clear consensus on the opinion of anatomists on the utility of embalmed cadavers for the teaching of anatomy. To this end, we aimed to survey British and Irish anatomy teachers to report their opinions on different preservation methods for the teaching of anatomy. In this project eight human cadavers were embalmed using formalin, Genelyn, Thiel and Imperial College London- Soft Preserving (ICL-SP) techniques to compare different characteristics of these four techniques. The results of this thesis show that anatomy teachers consider hard-fixed cadavers not to be the most accurate teaching model in comparison to the human body, although it still serves as a useful teaching method (Chapter 2). In addition, our findings confirm that joints of cadavers embalmed using ICL-SP solution faithfully mimics joints of an unembalmed cadaver compared to the other techniques (Chapter 3). Embalming a human body prevents the deterioration in the quality of images and our findings highlight that the influence of the embalming solutions varied with the radiological modality used (Chapter 4). The method developed as part of this thesis enables anatomists and forensic scientists to quantify the decomposition rate of an embalmed human cadaver (Chapter 5). Formalin embalming solution showed the strongest antimicrobial abilities followed by Thiel, Genelyn and finally by ICL-SP (Chapter 6). The overarching viewpoint of this set of studies show that it is inaccurate to state that one embalming technique is ultimately the best. The value of each technique differs based on the requirement of the particular education or research area. Hence we highlight how different embalming techniques may be better suited to certain fields of study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The lamination and burrowing patterns in 17 box cores were analyzed with the aid of X-ray photographs and thin sections. A standardized method of log plotting made statistical analysis of the data possible. Several 'structure types' were established, although it was realized that the boundaries are purely arbitrary divisions in what can sometimes be a continuous sequence. In the transition zone between marginal sand facies and fine-grained basin facies, muddy sediment is found which contains particularly well differentiated, alternating laminae. This zone is also characterized by layers rich in plant remains. The alternation of laminae shows a high degree of statistical scattering. Even though a small degree of cyclic periodicity could be defined, it was impossible to correlate individual layers from core to core across the bay. However, through a statistical handling of the plots, zones could be separated on the basis of the number of sand layers they contained. These more or minder sandy zones clarified the bottom reflections seen in the records of the echograph from the area. The manner of facies change across the bay, suggests that no strong bottom currents are effective in the Eckernförde Bay. The marked asymmetry between the north and south flanks of the profile can be attributed to the stronger action of waves on the more exposed areas. Grain size analyses were made from the more homogeneous units found in a core from the transition-facies zone. The results indicate that the most pronounced differences between layers appear in the silt range, and although the differences are slight, they are statistically significant. Layers rich in plant remains were wet-sieved in order to separate the plant detritus. This was than analyzed in a sediment settling balance and found to be hydrodynamically equivalent to a well-sorted, finegrained sand. A special, rhythmic cross-bedding type with dimensions in the millimeter range, has been named 'Crypto-cross-lamination' and is thought to represent rapid sedimentation in an area where only very weak bottom currents are present. It is found only in the deepest part of the basin. Relatively large sand grains, scattered within layers of clayey-silty matrix, seem to be transported by flotation. Thin section examination showed that the inner part of Eckernförder Bay carbonate grains (e. g. Foraminifera shells) were preserved throughout the cores, while in the outer part of the bay they were not present. Well defined tracks and burrows are relatively rare in all of the facies in comparision to the generally strongly developed deformation burrowing. The application of special measures for the deformation burrowing allowed to plot their intensity in profile for each core. A degree of regularity could be found in these burrowing intensity plots, with higher values appearing in the sandy facies, but with no clear differences between sand and silt layers in the transition facies. Small sections in the profiles of the deepest part of the bay show no bioturbation at all.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As part of the ultrafast charge dynamics initiated by high intensity laser irradiations of solid targets,high amplitude EM pulses propagate away from the interaction point and are transported along anystalks and wires attached to the target. The propagation of these high amplitude pulses along a thinwire connected to a laser irradiated target was diagnosed via the proton radiography technique,measuring a pulse duration of 20 ps and a pulse velocity close to the speed of light. The strongelectric field associated with the EM pulse can be exploited for controlling dynamically the protonbeams produced from a laser-driven source. Chromatic divergence control of broadband laser drivenprotons (upto 75% reduction in divergence of >5 MeV protons) was obtained by winding the supportingwire around the proton beam axis to create a helical coil structure. In addition to providingfocussing and energy selection, the technique has the potential to post-accelerate the transiting protonsby the longitudinal component of the curved electric field lines produced by the helical coil lens.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A small scale sample nuclear waste package, consisting of a 28 mm diameter uranium penny encased in grout, was imaged by absorption contrast radiography using a single pulse exposure from an X-ray source driven by a high-power laser. The Vulcan laser was used to deliver a focused pulse of photons to a tantalum foil, in order to generate a bright burst of highly penetrating X-rays (with energy >500 keV), with a source size of <0.5 mm. BAS-TR and BAS-SR image plates were used for image capture, alongside a newly developed Thalium doped Caesium Iodide scintillator-based detector coupled to CCD chips. The uranium penny was clearly resolved to sub-mm accuracy over a 30 cm2 scan area from a single shot acquisition. In addition, neutron generation was demonstrated in situ with the X-ray beam, with a single shot, thus demonstrating the potential for multi-modal criticality testing of waste materials. This feasibility study successfully demonstrated non-destructive radiography of encapsulated, high density, nuclear material. With recent developments of high-power laser systems, to 10 Hz operation, a laser-driven multi-modal beamline for waste monitoring applications is envisioned.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Atresia coli is a congenital defect with disruption of the intestinal flow. Its etiopathogenesis is still unknown and the prognosis is reserved. This paper describes the case of a one week old Holstein Friesian calf that was referred to the HCVC, and was diagnosed with atresia coli. This confirmation was made by contrast radiography and the lesion was detected in dorsal portion of the spiral colon. A cecostomy was performed followed by a marsupialization of the intestinal cecum to the abdominal wall. After 36 hours of surgery, calf’s state worsens dramatically and for reasons of welfare, it was proceeded to sacrifice. The post-operative recovery is possible, even though the mortality rate is high. As in this case, this mortality rate increases when early diagnosis of atresia coli does not take place and there is peritonitis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The education of the radiography profession is based within higher education establishments, yet a critical part of all radiography programmes is the clinical component where students learn the practical skills of the profession. Assessments therefore not only have to assess a student’s knowledge, but also their clinical competence and core skills in line with both Health and Care Professions Council and the Society and College of Radiographers requirements. This timely thesis examines the possibility of using the Virtual Environment for RadioTherapy (VERT) as an assessment tool to evaluate a student’s competence so giving the advantage of a standard assessment and relieving time pressures in the clinical department. A mixed methods approach was taken which can be described as a Quantitative Qualitative design with the emphasis being on the Quantitative element; a so called QUAN  qual design. The quantitative evaluation compared two simulations, one in the virtual reality environment and another in the department using a real treatment machine. Students were asked to perform two electron setups in each simulation; the order being randomly decided and so the study would be described as a randomised cross-over design. Following this, qualitative data was collected in student focus groups to explore student perspectives in more depth. Findings indicated that the performance between the two simulators was significantly different, p < 0∙001; the virtual simulation scoring significantly lower than the hospital based simulation overall and in virtually all parameters being assessed. Thematic analysis of the qualitative data supported this finding and identified 4 main themes; equipment use, a lack of reality, learning opportunities and assessment of competence. One other sub-theme identified for reality was that of the environment and senses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-08

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate if physical measures of noise predict image quality at high and low noise levels. Method: Twenty-four images were acquired on a DR system using a Pehamed DIGRAD phantom at three kVp settings (60, 70 and 81) across a range of mAs values. The image acquisition setup consisted of 14 cm of PMMA slabs with the phantom placed in the middle at 120 cm SID. Signal-to-noise ratio (SNR) and Contrast-tonoise ratio (CNR) were calculated for each of the images using ImageJ software and 14 observers performed image scoring. Images were scored according to the observer`s evaluation of objects visualized within the phantom. Results: The R2 values of the non-linear relationship between objective visibility score and CNR (60kVp R2 = 0.902; 70Kvp R2 = 0.913; 80kVp R2 = 0.757) demonstrate a better fit for all 3 kVp settings than the linear R2 values. As CNR increases for all kVp settings the Object Visibility also increases. The largest increase for SNR at low exposure values (up to 2 mGy) is observed at 60kVp, when compared with 70 or 81kVp.CNR response to exposure is similar. Pearson r was calculated to assess the correlation between Score, OV, SNR and CNR. None of the correlations reached a level of statistical significance (p>0.01). Conclusion: For object visibility and SNR, tube potential variations may play a role in object visibility. Higher energy X-ray beam settings give lower SNR but higher object visibility. Object visibility and CNR at all three tube potentials are similar, resulting in a strong positive relationship between CNR and object visibility score. At low doses the impact of radiographic noise does not have a strong influence on object visibility scores because in noisy images objects could still be identified.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A radiação-x foi descoberta há mais de uma centena de anos e com o avanço tecnológico diversas formas de aplicação têm vindo a ser descobertas. A utilização constante, devido à ajuda preciosa que estes dispositivos fornecem aos clínicos de Medicina Dentária, faz com que o paciente venha, de forma crescente, a ser exposto a este tipo de radiação. Este trabalho de revisão descritiva tem como principal propósito analisar os riscos, as formas de avaliação e de proteção da radiação-x, no âmbito do seu uso em Medicina Dentária. Para o efeito, realizou-se uma revisão da literatura, tendo-se recorrido ao motor de busca EBSCO host©, utilizando as frases boleanas: (X-ray risk OR Radiography risk OR Dental x-ray risk) AND (Dental Medicine OR Oral), foi substituída a palavra risk por “evaluation” e por “protection”. Desta pesquisa resultaram 82 documentos como referências bibliográficas. Esta revisão de literatura permitiu compreender a diferença entre radiação ionizante e não ionizante, quais os dispositivos utlizados na Medicina Dentária e o seu funcionamento geral, quais as unidades de medida da radiação, quais os riscos iminentes à exposição cumulativa e quais as suas consequências biológicas, perceber de que forma a legislação Portuguesa tem evoluído em matéria de radiação ionizante, quais as diversas formas de redução da dose absorvida pelo paciente e quais as medidas de proteção para os profissionais de saúde expostos à radiação ionizante.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose - In this study we aim to validate a method to assess the impact of reduced visual function and observer performance concurrently with a nodule detection task. Materials and methods - Three consultant radiologists completed a nodule detection task under three conditions: without visual defocus (0.00 Dioptres; D), and with two different magnitudes of visual defocus (−1.00 D and −2.00 D). Defocus was applied with lenses and visual function was assessed prior to each image evaluation. Observers evaluated the same cases on each occasion; this comprised of 50 abnormal cases containing 1–4 simulated nodules (5, 8, 10 and 12 mm spherical diameter, 100 HU) placed within a phantom, and 25 normal cases (images containing no nodules). Data was collected under the free-response paradigm and analysed using Rjafroc. A difference in nodule detection performance would be considered significant at p < 0.05. Results - All observers had acceptable visual function prior to beginning the nodule detection task. Visual acuity was reduced to an unacceptable level for two observers when defocussed to −1.00 D and for one observer when defocussed to −2.00 D. Stereoacuity was unacceptable for one observer when defocussed to −2.00 D. Despite unsatisfactory visual function in the presence of defocus we were unable to find a statistically significant difference in nodule detection performance (F(2,4) = 3.55, p = 0.130). Conclusion - A method to assess visual function and observer performance is proposed. In this pilot evaluation we were unable to detect any difference in nodule detection performance when using lenses to reduce visual function.