950 resultados para Pulmonary function test
Resumo:
PURPOSE: To correlate damage to the retinal pigment epithelium (RPE) with decreased visual function after the systemic administration of sodium iodate (NaIO(3)). METHODS: Damage was produced in mice by injection of 15, 25, or 35 mg/kg NaIO(3). Visual function was assessed with the cued water maze (WM) behavioral test and the optokinetic reflex (OKR) measurement at different times after injection. Autofluorescence in whole eye flatmounts was quantified, and hematoxylin and eosin staining of paraffin sections was performed to assess changes in the outer retina. RESULTS: After 15 mg/kg NaIO(3), cued WM test results were normal, whereas OKR measurements were significantly decreased at all times. Focal RPE loss began on day 21, but no significant damage to the outer nuclear layer was observed. After 25 mg/kg NaIO(3), the cued WM test was transitionally reduced and the OKR measurement again decreased at all times. Large areas of RPE loss occurred on day 14 with a reduced outer nuclear layer on the same day. With 35 mg/kg NaIO(3), the cued WM test was reduced beginning on day 14 with complete obliteration of the OKR beginning on day 3, large areas of RPE loss on the same day, and a reduced outer nuclear layer on day 7. CONCLUSIONS: Stable, patchy RPE loss was observed with a low concentration of NaIO(3). The OKR measurement showed changes in visual function earlier than the cued WM test and before histologic findings were observed.
Resumo:
OBJECTIVE: Treatment of central and paracentral pulmonary embolism in patients with hemodynamic compromise remains a subject of debate, and no consensus exists regarding the best method: thrombolytic agents, catheter-based thrombus aspiration or fragmentation, or surgical embolectomy. We reviewed our experience with emergency surgical pulmonary embolectomy. METHODS: Between January of 2000 and March of 2007, 25 patients (17 male, mean age 60 years) underwent emergency open embolectomy for central and paracentral pulmonary embolism. Eighteen patients presented in cardiogenic shock, 8 of whom had cardiac arrest and required cardiopulmonary resuscitation. All patients underwent operation with mild hypothermic cardiopulmonary bypass. Concomitant procedures were performed in 8 patients (3 coronary artery bypass grafts, 2 patent foramen ovale closures, 4 ligations of the left atrial appendage, 3 removals of a right atrial thrombus). Follow-up is 96% complete with a median of 2 years (range, 2 months to 6 years). RESULTS: All patients survived the procedure, but 2 patients died in the hospital on postoperative days 1 (intracerebral bleeding) and 11 (multiorgan failure), accounting for a 30-day mortality of 8% (95% confidence interval: 0.98-0.26). Four patients died later because of their underlying disease. Pre- and postoperative echocardiographic pressure measurements demonstrated the reduction of the pulmonary hypertension to half of the systemic pressure values or less. CONCLUSION: Surgical pulmonary embolectomy is an excellent option for patients with major pulmonary embolism and can be performed with minimal mortality and morbidity. Even patients who present with cardiac arrest and require preoperative cardiopulmonary resuscitation show satisfying results. Immediate surgical desobstruction favorably influences the pulmonary pressure and the recovery of right ventricular function, and remains the treatment of choice for patients with massive central and paracentral embolism with hemodynamic and respiratory compromise.
Resumo:
Real time battery impedance spectrum is acquired using one time record, Compensated Synchronous Detection (CSD). This parallel method enables battery diagnostics. The excitation current to a test battery is a sum of equal amplitude sin waves of a few frequencies spread over range of interest. The time profile of this signal has duration that is a few periods of the lowest frequency. The voltage response of the battery, average deleted, is the impedance of the battery in the time domain. Since the excitation frequencies are known, synchronous detection processes the time record and each component, both magnitude and phase, is obtained. For compensation, the components, except the one of interest, are reassembled in the time domain. The resulting signal is subtracted from the original signal and the component of interest is synchronously detected. This process is repeated for each component.
Resumo:
BACKGROUND: Complete investigation of thrombophilic or hemorrhagic clinical presentations is a time-, apparatus-, and cost-intensive process. Sensitive screening tests for characterizing the overall function of the hemostatic system, or defined parts of it, would be very useful. For this purpose, we are developing an electrochemical biosensor system that allows measurement of thrombin generation in whole blood as well as in plasma. METHODS: The measuring system consists of a single-use electrochemical sensor in the shape of a strip and a measuring unit connected to a personal computer, recording the electrical signal. Blood is added to a specific reagent mixture immobilized in dry form on the strip, including a coagulation activator (e.g., tissue factor or silica) and an electrogenic substrate specific to thrombin. RESULTS: Increasing thrombin concentrations gave standard curves with progressively increasing maximal current and decreasing time to reach the peak. Because the measurement was unaffected by color or turbidity, any type of blood sample could be analyzed: platelet-poor plasma, platelet-rich plasma, and whole blood. The test strips with the predried reagents were stable when stored for several months before testing. Analysis of the combined results obtained with different activators allowed discrimination between defects of the extrinsic, intrinsic, and common coagulation pathways. Activated protein C (APC) predried on the strips allowed identification of APC-resistance in plasma and whole blood samples. CONCLUSIONS: The biosensor system provides a new method for assessing thrombin generation in plasma or whole blood samples as small as 10 microL. The assay is easy to use, thus allowing it to be performed in a point-of-care setting.
Resumo:
OBJECTIVES: Pulmonary valve insufficiency remains a leading cause for reoperations in congenital cardiac surgery. The current percutaneous approach is limited by the size of the access vessel and variable right ventricular outflow tract morphology. This study assesses the feasibility of transapical pulmonary valve replacement based on a new valved stent construction concept. METHODS: A new valved stent design was implanted off-pump under continuous intracardiac echocardiographic and fluoroscopic guidance into the native right ventricular outflow tract in 8 pigs (48.5 +/- 6.0 kg) through the right ventricular apex, and device function was studied by using invasive and noninvasive measures. RESULTS: Procedural success was 100% at the first attempt. Procedural time was 75 +/- 15 minutes. All devices were delivered at the target site with good acute valve function. No valved stents dislodged. No animal had significant regurgitation or paravalvular leaking on intracardiac echocardiographic analysis. All animals had a competent tricuspid valve and no signs of right ventricular dysfunction. The planimetric valve orifice was 2.85 +/- 0.32 cm(2). No damage to the pulmonary artery or structural defect of the valved stents was found at necropsy. CONCLUSIONS: This study confirms the feasibility of direct access valve replacement through the transapical procedure for replacement of the pulmonary valve, as well as validity of the new valved stent design concept. The transapical procedure is targeting a broader patient pool, including the very young and the adult patient. The device design might not be restricted to failing conduits only and could allow for implantation in a larger patient population, including those with native right ventricular outflow tract configurations.
Resumo:
OBJECTIVE: To determine if neurally adjusted ventilatory assist (NAVA) that delivers pressure in proportion to diaphragm electrical activity is as protective to acutely injured lungs (ALI) and non-pulmonary organs as volume controlled (VC), low tidal volume (Vt), high positive end-expiratory pressure (PEEP) ventilation. DESIGN: Prospective, randomized, laboratory animal study. SUBJECTS: Twenty-seven male New Zealand white rabbits. INTERVENTIONS: Anesthetized rabbits with hydrochloric acid-induced ALI were randomized (n = 9 per group) to 5.5 h NAVA (non-paralyzed), VC (paralyzed; Vt 6-ml/kg), or VC (paralyzed; Vt 15-ml/kg). PEEP was adjusted to hemodynamic goals in NAVA and VC6-ml/kg, and was 1 cmH2O in VC15-ml/kg. MEASUREMENTS AND MAIN RESULTS: PaO2/FiO2; lung wet-to-dry ratio; lung histology; interleukin-8 (IL-8) concentrations in broncho-alveolar-lavage (BAL) fluid, plasma, and non-pulmonary organs; plasminogen activator inhibitor type-1 and tissue factor in BAL fluid and plasma; non-pulmonary organ apoptosis rate; creatinine clearance; echocardiography. PEEP was similar in NAVA and VC6-ml/kg. During NAVA, Vt was lower (3.1 +/- 0.9 ml/kg), whereas PaO2/ FiO2, respiratory rate, and PaCO2 were higher compared to VC6-ml/kg (p<0.05 for all). Variables assessing ventilator-induced lung injury (VILI), IL-8 levels, non-pulmonary organ apoptosis rate, and kidney as well as cardiac performance were similar in NAVA compared to VC6-ml/kg. VILI and non-pulmonary organ dysfunction was attenuated in both groups compared to VC15-ml/kg. CONCLUSIONS: In anesthetized rabbits with early experimental ALI, NAVA is as effective as VC6-ml/kg in preventing VILI, in attenuating excessive systemic and remote organ inflammation, and in preserving cardiac and kidney function.
Resumo:
The aim of the present study was to investigate prefrontal brain function and cognitive response control in patients with personality disorders who either suffered or did not suffer from psychopathology related to attention deficit hyperactivity disorder (ADHD) during childhood. For this purpose, 36 psychiatric out-patients with personality disorders--24 of whom showed ADHD-related psychopathology during childhood assessed by the German short form of the Wender Utah Rating Scale--and 24 healthy controls were investigated electrophysiologically by means of a cued Go-NoGo task (Continuous Performance Test). Topographical analyses were conducted to individually quantify the NoGo anteriorisation (NGA), a neurophysiological correlate of prefrontal response control that has been suggested to reflect activation of the anterior cingulate cortex. ADHD patients exhibited a significantly reduced mean NGA and diminished amplitudes of the Global Field Power, as well as a reduced increase of fronto-central P300 amplitudes, in NoGo-trials compared with the healthy controls, whereas patients with personality disorders alone did not differ from the control group in any of the electrophysiological parameters. The results indicate that ADHD-related psychopathology is associated with prefrontal brain dysfunction, probably related to processes of response inhibition and/or cognitive response control.
Resumo:
BACKGROUND Little is known about the vasomotor function of human coronary collateral vessels. The purpose of this study was to examine collateral flow under a strong sympathetic stimulus (cold pressor test, CPT). METHODS In 30 patients (62 +/- 12 years) with coronary artery disease, two subsequent coronary artery occlusions were performed with random CPT during one of them. Two minutes before and during the 1 minute-occlusion, the patient's hand was immerged in ice water. For the calculation of a perfusion pressure-independent collateral flow index (CFI), the aortic (Pao), the central venous (CVP) and the coronary wedge pressure (Poccl) were measured: CFI = (Poccl - CVP)/(Pao - CVP). RESULTS CPT lead to an increase in Pao from 98 +/- 14 to 105 +/- 15 mm Hg (p = 0.002). Without and with CPT, CFI increased during occlusion from 14% +/- 10% to 16% +/- 10% (p = 0.03) and from 17% +/- 9% to 19% +/- 9% (p = 0.006), respectively, relative to normal flow. During CPT, CFI was significantly higher at the beginning as well as at the end of the occlusion compared to identical instants without CPT. CFI at the end of the control occlusion did not differ significantly from the CFI at the beginning of occlusion with CPT. CONCLUSIONS During balloon occlusion, collateral flow increased due to collateral recruitment independent of external sympathetic stimulation. Sympathetic stimulation using CPT additionally augmented collateral flow. The collateral-flow-increasing effect of CPT is comparable to the recruitment effect of the occlusion itself. This may reflect a coronary collateral vasodilation mediated by the sympathetic nervous system.
Resumo:
OBJECTIVE To determine the pulmonary venous flow velocity (PVFV) values in a large normal population. DESIGN Prospective study in consecutive individuals. SETTING University hospital. METHODS Among 404 normal individuals, the flow velocity pattern in the right upper pulmonary vein was recorded in 315 subjects using transthoracic echocardiography, and in both upper pulmonary veins in 100 subjects using transoesophageal echocardiography. Subjects were divided into five age groups. The PVFV values were compared between transthoracic and transoesophageal echocardiography within the age groups, and intraindividually between the right and left upper pulmonary veins in transoesophageal echocardiography. RESULTS Normal PVFV values for the right upper pulmonary vein in transthoracic and transoesophageal echocardiography are presented. The duration of flow reversal at atrial contraction was overestimated using transthoracic echocardiography (mean (SD): 96 (21) ms in transoesophageal echocardiography, 120 (28) ms in transthoracic echocardiography, p < 0.0001). Systolic to diastolic peak flow velocity ratio (S:D) increased earlier with advancing age with transoesophageal echocardiography than with transthoracic echocardiography. Similar results were found for the corresponding time-velocity integrals. Data from the left and right upper pulmonary veins differed with respect to onset and deceleration of flow velocities, but not for flow durations or peak velocities. CONCLUSIONS Normal PVFV values generally show a wide range. The data presented will be of value in assessing left ventricular diastolic function and mitral regurgitation using the PVFV pattern.
Resumo:
OBJECTIVES The aim of this study was to evaluate right ventricular (RV) and left ventricular function and pulmonary circulation in chronic mountain sickness (CMS) patients with rest and stress echocardiography compared with healthy high-altitude (HA) dwellers. BACKGROUND CMS or Monge's disease is defined by excessive erythrocytosis (hemoglobin >21 g/dl in males, 19 g/dl in females) and severe hypoxemia. In some cases, a moderate or severe increase in pulmonary pressure is present, suggesting a similar pathogenesis of pulmonary hypertension. METHODS In La Paz (Bolivia, 3,600 m sea level), 46 CMS patients and 40 HA dwellers of similar age were evaluated at rest and during semisupine bicycle exercise. Pulmonary artery pressure (PAP), pulmonary vascular resistance, and cardiac function were estimated by Doppler echocardiography. RESULTS Compared with HA dwellers, CMS patients showed RV dilation at rest (RV mid diameter: 36 ± 5 mm vs. 32 ± 4 mm, CMS vs. HA, p = 0.001) and reduced RV fractional area change both at rest (35 ± 9% vs. 43 ± 9%, p = 0.002) and during exercise (36 ± 9% vs. 43 ± 8%, CMS vs. HA, p = 0.005). The RV systolic longitudinal function (RV-S') decreased in CMS patients, whereas it increased in the control patients (p < 0.0001) at peak stress. The RV end-systolic pressure-area relationship, a load independent surrogate of RV contractility, was similar in CMS patients and HA dwellers with a significant increase in systolic PAP and pulmonary vascular resistance in CMS patients (systolic PAP: 50 ± 12 mm Hg vs. 38 ± 8 mm Hg, CMS vs. HA, p < 0.0001; pulmonary vascular resistance: 2.9 ± 1 mm Hg/min/l vs. 2.2 ± 1 mm Hg/min/l, p = 0.03). Both groups showed comparable systolic and diastolic left ventricular function both at rest and during stress. CONCLUSIONS Comparable RV contractile reserve in CMS and HA suggests that the lower resting values of RV function in CMS may represent a physiological adaptation to chronic hypoxic conditions rather than impaired RV function. (Chronic Mountain Sickness, Systemic Vascular Function [CMS]; NCT01182792).
Resumo:
BACKGROUND The issue of phrenic nerve preservation during pneumonectomy is still an unanswered question. So far, its direct effect on immediate postoperative pulmonary lung function has never been evaluated in a prospective trial. METHODS We conducted a prospective crossover study including 10 patients undergoing pneumonectomy for lung cancer between July 2011 and July 2012. After written informed consent, all consecutive patients who agreed to take part in the study and in whom preservation of the phrenic nerve during operation was possible, were included in the study. Upon completion of lung resection, a catheter was placed in the proximal paraphrenic tissue on the pericardial surface. After an initial phase of recovery of 5 days all patients underwent ultrasonographic assessment of diaphragmatic motion followed by lung function testing with and without induced phrenic nerve palsy. The controlled, temporary paralysis of the ipsilateral hemidiaphragm was achieved by local administration of lidocaine 1% at a rate of 3 mL/h (30 mg/h) via the above-mentioned catheter. RESULTS Temporary phrenic nerve palsy was accomplished in all but 1 patient with suspected catheter dislocation. Spirometry showed a significant decrease in dynamic lung volumes (forced expiratory volume in 1 second and forced vital capacity; p < 0.05) with the paralyzed hemidiaphragm. Blood oxygen saturation levels did not change significantly. CONCLUSIONS Our results show that phrenic nerve palsy causes a significant impairment of dynamic lung volumes during the early postoperative period after pneumonectomy. Therefore, in these already compromised patients, intraoperative phrenic nerve injury should be avoided whenever possible.
Resumo:
We present a novel approach to the inference of spectral functions from Euclidean time correlator data that makes close contact with modern Bayesian concepts. Our method differs significantly from the maximum entropy method (MEM). A new set of axioms is postulated for the prior probability, leading to an improved expression, which is devoid of the asymptotically flat directions present in the Shanon-Jaynes entropy. Hyperparameters are integrated out explicitly, liberating us from the Gaussian approximations underlying the evidence approach of the maximum entropy method. We present a realistic test of our method in the context of the nonperturbative extraction of the heavy quark potential. Based on hard-thermal-loop correlator mock data, we establish firm requirements in the number of data points and their accuracy for a successful extraction of the potential from lattice QCD. Finally we reinvestigate quenched lattice QCD correlators from a previous study and provide an improved potential estimation at T2.33TC.
Resumo:
BACKGROUND Small airways disease is a hallmark in adults with persistent asthma, but little is known about small airways function in children with mild asthma and normal spirometry. We assessed ventilation heterogeneity, a marker of small airways function, with an easy tidal breath single-breath washout (SBW) technique in school-aged children with mild asthma and normal FEV1 and healthy age-matched control subjects. METHODS The primary outcome was the double-tracer gas phase III slope (SDTG), an index of ventilation heterogeneity in acinar airways derived from the tidal double-tracer gas SBW test. The second outcome was the nitrogen phase III slope (SN2), an index of global ventilation heterogeneity derived from the tidal nitrogen SBW test using pure oxygen. Triplicate SBW and spirometry tests were performed in healthy children (n = 35) and children with asthma (n = 31) at baseline and in children with asthma after bronchodilation. RESULTS Acinar (SDTG) but not global (SN2) ventilation heterogeneity was significantly increased in asthma despite normal FEV1. Of the 31 children with asthma, abnormal results were found for SDTG (≤ -2 z scores) in 11; forced expiratory flow, midexpiratory phase (FEF25%-75%) in three; and FEV1 in zero. After bronchodilation, SDTG, SN2, FEF25%-75%, and FEV1 significantly changed (mean [95% CI] change from baseline, 36% [15%-56%], 38% [18%-58%], 17% [9-25%], and 6% [3%-9%], respectively). CONCLUSIONS Abnormal acinar ventilation heterogeneity in one-third of the children suggests that small airways disease may be present despite rare and mild asthma symptoms and normal spirometry. The easy tidal SBW technique has considerable potential as a clinical and research outcome in children with asthma.
Resumo:
BACKGROUND Assessment of pre-test probability of pulmonary embolism (PE) and prognostic stratification are two widely recommended steps in the management of patients with suspected PE. Some items of the Geneva prediction rule may have a prognostic value. We analyzed whether the initial probability assessed by the Geneva rule was associated with the outcome of patients with PE. METHODS In a post-hoc analysis of a multicenter trial including 1,693 patients with suspected PE, the all-cause death or readmission rates during the 3-month follow-up of patients with confirmed PE were analyzed. PE probability group was prospectively assessed by the revised Geneva score (RGS). Similar analyses were made with the a posteriori-calculated simplified Geneva score (SGS). RESULTS PE was confirmed in 357 patients and 21 (5.9%) died during the 3-month follow-up. The mortality rate differed significantly with the initial RGS group, as with the SGS group. For the RGS, the mortality increased from 0% (95% Confidence Interval: [0-5.4%]) in the low-probability group to 14.3% (95% CI: [6.3-28.2%]) in the high-probability group, and for the SGS, from 0% (95% CI: [0-5.4%] to 17.9% (95% CI: [7.4-36%]). Readmission occurred in 58 out of the 352 patients with complete information on readmission (16.5%). No significant change of readmission rate was found among the RGS or SGS groups. CONCLUSIONS Returning to the initial PE probability evaluation may help clinicians predict 3-month mortality in patients with confirmed PE. (ClinicalTrials.gov: NCT00117169).
Resumo:
Colostrum (COL) contains cytokines and growth factors that may enhance intestinal development in neonates. The hypothesis of this study was that besides providing immunoglobulins, COL is important for intestinal function and meconium release in foals. Newborn foals were either fed COL (n = 5) or an equal amount of milk replacer (MR, n = 7) during the first 24 hours of life. To ensure passive immunity, all foals received 1 L plasma. Postnatal development, meconium release, intestinal motility, white blood cell count, insulin-like growth factor 1, and intestinal absorptive function (xylose absorption test) were evaluated. Clinical findings and meconium release were not affected by feeding of COL or MR. Ultrasonography revealed a slightly larger jejunum and stomach in group COL versus MR (P < 0.05). The percentage of polymorphonuclear leucocytes was higher in foals of group MR versus group COL (P < 0.05) and the percentage of lymphocytes was lower in MR compared with COL foals (P < 0.05). Plasma insulin-like growth factor 1 concentration increased during the first 14 days after birth in both groups. A xylose absorption test on Day 5 revealed similar increases in plasma xylose concentrations after oral intake. In conclusion, feeding of COL versus MR was without effect on meconium release and intestinal absorptive function. Differences between foals fed COL and MR with regard to intestinal function are apparently without clinical relevance. In foals that have not received maternal COL, there is no major risk of intestinal problems if they are fed MR and provided with immunoglobulins by transfusion of plasma.